Search NASA⌕ Search

SEARCH · Search NASA

Results for “ZVS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Modeling and ZVS Operation of the Isolated Modular Multilevel DC–DC Converter With a Unified Trapezoidal Wave Modulation

Here, this article introduces a unified trapezoidal wave (UTW) modulation scheme for the isolated modular multilevel dc–dc (IM2dc) converter, which consolidates multiple existing modulation strategies for the IM2dc converter, including the quasi-square wave (QSW) modulation, trapezoidal wave modulation, and sinusoidal wave modulation, into a unified framework. Furthermore, this article introduces the harmonic state-space (HSS) equations to model the IM2dc converter based on the UTW modulation method. The HSS model operates in the frequency domain, enabling it to circumvent the complexities associated with time-domain analysis and seamlessly integrate with the UTW modulation. This article proceeds to analyze the real and reactive power transfer characteristics of the IM2dc converter, as well as the power factor, considering the influence of multiple modulation parameters. Subsequently, it delves into the examination of zero voltage switching (ZVS) conditions for the IM2dc converter based on the UTW modulation and the HSS model. The complete ZVS boundaries of the IM2dc converter, taking various voltage ratios into account, are derived. This article also illustrates the effects of including harmonic orders in the modeling process, modulation parameters, and internal harmonic ripples on the ZVS boundaries. Finally, experimental validation of the analyses is conducted on a down-scaled prototype.

42 ENGINEERING↗

Constant Frequency ZVS PWM Converter

In this paper, a simple yet novel buck or boost adaptive zero-voltage switching (ZVS) converter topology is proposed for soft switching pulse-width modulation (PWM) dc / dc converters. The converter is designed for the high switching frequency that can achieve high efficiency by reducing switching losses for the entire load range at low and high power. Besides, the output at the load terminals is maintained by a PWM signal at a fixed switching frequency, a phase shift signal between converter ports (legs) controls the system circulating current in order to provide the ZVS condition in all load conditions. With the proposed controller, the converter, thus, is suitable for high switching frequency and high-power applications with the small volume. The proposed dc / dc converter operation is analyzed, designed, and confirmed by simulation results for 240 V input, 400 V / 5 A output, and 200 kHz operating frequency at full load.

Asa, Erdem↗

1 kV 150 A Bidirectional Isolated DC/DC Converter With Full Range ZVS For Charger Application

This paper focusses on the development of a bidirectional DC/DC converter based on dual active bridge (DAB) converter for 1 kV class fast charger applications. A novel modulation technique is proposed to achieve zero voltage switching across the entire operating range of a vehicle battery system. The topology includes a tap changer to support multiple class of vehicles. The full range ZVS operation will allow high efficiency operation even at light load, reduced dv/dt to improve transformer insulation lifetime and mitigate EMI impact. A 1 kV class, 150 A prototype was developed to validate the proposed concepts.

Kandula, Prasad↗

Design of a ZVS PWM inverter for a brushless DC motor in an EMA application

The Component Development Division of the Propulsion Laboratory at Marshall Space Flight Center (MSFC) is currently investigating the use of electromechanical actuators for use in space transportation applications such as Thrust Vector Control (TVC). These high power servomechanisms will require rugged, reliable, and compact power electronic modules capable of modulating several hundred amperes of current at up to 270 Vdc. This paper will discuss the design and implementation of a zero-voltage-switched PWM (Pulse Width Modulation) inverter which operates from a 270 Vdc source at currents up to 100 A.

Bell, J. Brett↗

1 kV, 10-kW SiC-Based Quadruple Active Bridge DCX Stage in a DC to Three-Phase AC Module for Medium-Voltage Grid Integration

Interfacing low voltage dc to medium voltage three-phase ac grid is often based on series-stackable modular converter architectures. To minimize energy storage requirements, it is advantageous to employ a quadruple active bridge (QAB) stage operating as a "dc transformer" in each stackable module. The QAB stage offers three isolated dc link voltages, which then allow for flexible stacking of three single-phase dc-to-ac inverter stages. Each of the module phases processes a pulsating power having a component at twice the line frequency. This presents a challenge in maintaining zero voltage switching (ZVS) on the secondary sides of the QAB during low-power portions of the line cycle. This article is focused on the design of the QAB stage. A detailed analysis of ZVS switching waveforms is presented, including effects of nonlinear device capacitances. It is shown how ZVS can be achieved at all times using a relatively small circulating current provided by the magnetizing inductance of the high-frequency transformer. Analytical expressions are given for the optimal values of the magnetizing inductance and the dead times of the QAB primary and secondary bridges. This approach is verified by experimental results on a 1 kV, 10-kW SiC-based prototype, demonstrating a relatively flat efficiency curve with a peak efficiency of 97.1% at 75% load.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Radiation Effects on DC-DC Converters

In this work, several DC-DC converters were designed and built. The converters are Buck Buck-Boost, Cuk, Flyback, and full-bridge zero-voltage switched. The total ionizing dose radiation and single event effects on the converters were investigated. The experimental results for the TID effects tests show that the voltages of the Buck Buck-Boost, Cuk, and Flyback converters increase as total dose increased when using power MOSFET IRF250 as a switching transistor. The change in output voltage with total dose is highest for the Buck converter and the lowest for Flyback converter. The trend of increase in output voltages with total dose in the present work agrees with those of the literature. The trends of the experimental results also agree with those obtained from PSPICE simulation. For the full-bridge zero-voltage switch converter, it was observed that the dc-dc converter with IRF250 power MOSFET did not show a significant change of output voltage with total dose. In addition, for the dc-dc converter with FSF254R4 radiation-hardened power MOSFET, the output voltage did not change significantly with total dose. The experimental results were confirmed by PSPICE simulation that showed that FB-ZVS converter with IRF250 power MOSFET's was not affected with the increase in total ionizing dose. Single Event Effects (SEE) radiation tests were performed on FB-ZVS converters. It was observed that the FB-ZVS converter with the IRF250 power MOSFET, when the device was irradiated with Krypton ion with ion-energy of 150 MeV and LET of 41.3 MeV-square cm/mg, the output voltage increased with the increase in fluence. However, for Krypton with ion-energy of 600 MeV and LET of 33.65 MeV-square cm/mg, and two out of four transistors of the converter were permanently damaged. The dc-dc converter with FSF254R4 radiation hardened power MOSFET's did not show significant change at the output voltage with fluence while being irradiated by Krypton with ion energy of 1.20 GeV and LET of 25.97 MeV-square cm/mg. This might be due to fact that the device is radiation hardened.

Zhang, De-Xin↗

Novel Quadratic High Gain Boost Converter With Adaptive Soft-Switching Scheme and Reduced Conduction Loss

In this article, an improved soft-switching quadratic boost converter is proposed. Instead of inserting an additional active clamp or auxiliary zero-voltage transition circuit at the switching node, the proposed topology connects the high-voltage switching node to the input diode node by replacing one of the input diodes with a low-rated switch. The proposed topology can attain soft-switching condition for all the switches and input diode turns- off under zero-current switching (ZCS). The operation of input-side switch not only aids zero-voltage switching (ZVS) turn- on for the main switch but also helps in reducing the conduction loss. Also, the input-side switch operates under ZCS turn- on and ZVS turn- off , making it a loss economical solution. An adaptive timing scheme for driving the input switch is proposed, which can ensure soft-switching condition under varying gain and load range. The detailed operational modes, analysis, and design considerations of the proposed topology are presented. A 250 W hardware prototype is built to validate the performance of the proposed converter operating at 100 kHz switching frequency. Results with adaptive soft-switching scheme shows that the converter is modulated to achieve its best efficiency condition under various system conditions. Furthermore, a peak efficiency of 96.1% at 155 W and efficiencies above 95.75% over a wide load range are achieved using all Si devices.

14 SOLAR ENERGY↗

Three-Phase LCC-LCC Compensated 50-kW Wireless Charging System with Non-Zero Interphase Coupling

In this paper, an LCC-LCC compensated 50 kW 3phase (3φ) wireless charging system with nonzero interphase mutual inductance is demonstrated. The 3φ-LCC compensation is designed considering a nonzero mutual-inductance among the phase-coils to meet resonance criteria, balance voltages and currents of the resonant tank components, achieve desired voltage gain, and ensure the zero-voltage switching (ZVS) operation. An experimental prototype of the 3φ-LCC-LCC compensation circuit is built for a 50 kW bipolar coil-based 3φ wireless charging system. The prototype system was tested at rated 50 kW power for evaluating the efficiency, ZVS operation, electric and magnetic field emissions, and thermal characteristics. The experimental results show 94.3% dc-to-dc efficiency and only 4.4 μT rms magnetic field emission at the rated 50 kW output power.

Mohammad, Mostak↗

A Dual-Active-Bridge Converter Employing a Variable Inductor Without an Auxiliary Circuit

This paper proposes a dual active bridge (DAB) converter employing a variable inductor (VI) without an auxiliary circuit. Unlike conventional VI-based designs that require an external DC bias circuit, the proposed DAB utilizes the input DC current itself as the bias source, enabling automatic inductance variation with load conditions. The inductance naturally increases at low power and decreases at high power, effectively extending the zero voltage switching (ZVS) range and reducing circulating current, respectively. The VI was experimentally implemented and characterized to obtain its inductance-current profile, which was then integrated into a PLECS model of the DAB converter for circuit and thermal simulations. Simulation results confirm that the proposed auxiliary-free VI-DAB converter achieves a wider ZVS range and lower circulating current compared with a conventional fixed-inductor DAB converter. By realizing a variable inductor without any auxiliary bias circuitry, the proposed approach maintains soft switching and reduces reactive current losses across a wide load range, leading to improved efficiency and simplified implementation.

Jo, Cheolhui [ORNL] (ORCID:0000000322692434)↗

Current-Source Solid-State DC Transformer Integrating LVDC Microgrid, Energy Storage, and Renewable Energy Into MVDC Grid

Solid-state DC transformer to integrate low-voltage DC (LVDC) microgrid, wind turbine (WT) generator, photovoltaic (PV), and energy storage (ES) into medium-voltage (MV) direct-current (MVDC) distribution grids is attractive. This paper proposes current-source DC solid-state transformer (SST) for MVDC collection system in WT, PV, and ES farms or as an interface between the MVDC grid and the LVDC microgrid. Compared to conventional current-source converter (CSC) based SSTs, a switch reduction scheme on reverse-blocking device bridges is proposed to reduce device count and the number of devices on the DC-link current path. Importantly, the proposed switch reduction scheme is generic and can be applied to the DC ports of DC-AC, AC-DC, or DC-DC hard-switching or soft-switching CSC-based SSTs. Based on this scheme, the proposed current-source DC SSTs are derived, which have reduced electrolytic-capacitor-less DC-link. The proposed DC SSTs also achieve single-stage isolated DC-DC or DC-AC conversion, full-range zero-voltage switching (ZVS) for main switches, zero-current switching (ZCS) for resonant switches, and controlled dv/dt. The proposed DC SSTs, operating principles, predictive control method, the ZVS, and the controlled dv/dt under voltage buck-boost ranges are verified with MV simulations and an experimental prototype based on SiC MOSFETs, diodes, and a nanocrystalline transformer.

14 SOLAR ENERGY↗

New Modulation and Impact of Transformer Leakage Inductance on Current-Source Solid-State Transformer

This article presents a novel modulation scheme for device voltage stress mitigation and comprehensive analysis of the impact of transformer leakage inductance in a current-source solid-state transformer (SST). Different from dual active bridge (DAB) SST, the operation of the current-source SST is similar to that of a flyback converter. The device bridge on only one side of the transformer is active to store energy into or release energy from the magnetizing inductance which acts as a current-source dc link. Such flyback operation with reverse-blocking switches can lead to additional device voltage stress and incomplete zero-voltage switching (ZVS) on the current-source soft-switching solid-state transformer (S4T) under conventional modulation. A new modulation scheme is proposed to address this issue. Moreover, different from the DAB, the leakage inductance of the medium-frequency transformer (MFT) in the S4T is a parasitic element similar to that in a matrix SST and can cause additional device voltage stress. Though the resonant capacitors, originally added to achieve ZVS, can absorb and recycle the leakage energy in the S4T, these capacitors need to be increased with larger leakage inductances to limit the voltage stress. However, large resonant capacitors can result in more lost duty cycles and reduced efficiency. The impact of such leakage inductance on device voltage stress is analyzed comprehensively, which is critical to guide future research and design of the S4T. Experimental results from S4T prototypes for DC-DC, multiport AC-DC, and AC-AC conversion with 1:1 and 4:1 MFT comprehensively verify the proposed concepts. Lastly, a case study of a three-phase AC-AC S4T over a power range from 1 kVA to 100 kVA each module reveals that the MFT leakage inductance should be less than 1% of the magnetizing inductance for safe operation.

14 SOLAR ENERGY↗

Design of power electronics for TVC and EMA systems

The EMA systems proposed for future space transportation applications are high power systems operating at voltages up to 270 Vdc and at current levels on the order of hundreds of amperes. The position of the actuator is controlled by modulating the flow of energy from the source to an electric motor with an inverter. Hard-switching of the semiconductor devices in the inverter results in considerable device switching stresses and losses and in the generation of substantial amounts of EMI. Both of these can be reduced by employing zero-voltage-switching (ZVS) techniques in the inverter. This project has focused on the development of a ZVS inverter for the Marshall Space Center EMA prototypes, which utilize brushless dc motors to convert electrical energy to mechanical energy. An inverter which permitted zero-voltage switching and a quasi-PWM operation was selected for study and implementation. A waveshaping circuit is added to the front of a standard three-phase inverter to achieve the desired switching properties. This circuit causes the input voltage of the three-phase inverter to ring to zero where it is clamped for a short period of time. During this zero-voltage period, any of the semiconductor switches in the three-phase inverter are switched on or off at zero voltage resulting in a reduction in switching losses and EMI. The operation of this waveshaping circuit and its interaction with the three-phase inverter are described. The different circuit modes were analyzed using equivalent circuits. Based on this analysis, design relationships were developed for calculating component values for the circuit elements in the waveshaping circuit. Waveforms of various voltages and currents in the waveshaping circuit were plotted and used to determine the ratings of the semiconductors in the waveshaping circuit. The implementation of this inverter are described. Block diagrams for the overall control system and the waveshaping circuit control are presented and discussed. The current control scheme employed in the controller is also described.

Nelms, R. Mark↗