Zero Boil Off Cryogen Storage for Future Launchers

Zero boil off (ZBO) cryogen storage using both cryocoolers and passive insulation technologies will enable long-term exploration missions by allowing designers to optimize tankage without the need for excess cryogen storage to account for boil off. Studies of ZBO (zero boil off) have been on-going in the USA for several years. More recently, a review of the needs of advanced space propulsion took place in Europe. This showed the interest of the European community in cryogenic propulsion for planetary missions as well as the use of liquid hydrogen for large power electric propulsion (manned Mars missions). Although natural boiling could be acceptable for single leg missions, passive insulation techniques yield roughly a I% per month cryogen loss and this would not be cost effective for robotic planetary missions involving storage times greater than one year. To make economic sense, long-term exploration missions require lower tank capacity and longer storage times. Recent advances in cryocooler technology, resulting in vast improvements in both cooler efficiency and reliability, make ZBO is a clear choice for planetary exploration missions. Other, more near term applications of ZBO include boil-off reduction or elimination applied to first and upper stages of future earth-to-orbit (ETO) launchers. This would extend launch windows and reduce infrastructure costs. Successors to vehicles like Ariane 5 could greatly benefit by implementing ZBO. Zero Boil Off will only be successful in ETO launcher applications if it makes economic sense to implement. The energy cost is only a fraction of the total cost of buying liquid cryogen, the rest being transportation and other overhead. Because of this, higher boiling point cryogens will benefit more from on-board liquefaction, thus reducing the infrastructure costs. Since hydrogen requires a liquefier with at least a 17% efficiency just to break even from a cost standpoint, one approach for implementing ZBO in upper stages would be to actively cool the shield in the hydrogen tank to reduce the parasitic losses. This would allow the use of less expensive, presently available coolers (80 K vs. 20 K) and potentially simplify the system by requiring only a single compressor on the pad amd a single disconnect line. The compressor could be a hefty commercial unit, with only the cold head requiring expensive flight development and qualification. While this is actually a reduced boil off configuration rather than a zero-boil off case, if the cryogen loss could be cut significantly, the increase in hold time and reduced need for draining and refilling the propellant tanks could meet the vehicle operations needs in the majority of instances.Bearing in mind the potential benefits of ZBO, NASA AMES and SNECMA Moteurs decided to exchange their technical views on the subject. This paper will present a preliminary analysis for a multi-mission module using a fairly low thrust cryogenic engine and ZBO during cruise. Initial mass is 5.5. tons (in ETO). The cryogenic engine will be used near each periapsis in order to minimize the AV requirement. The payload obtained by this propulsion system is compared to a classical storable bipropellant propulsion system for several cases (e. g. Mars lander, Jupiter orbiter, Saturn orbiter). For the Jupiter and Saturn cases, the power source could be an RTG or a large parabolic mirror illuminating a solar panel. It is shown -that - due to its much larger specific impulse - the cryogenic ZBO solution provides much higher payloads, especially for exploration missions involving landing on planets, asteroids, comets, or other celestial bodies.

Valentian, D.↗

Modeling and Simulation of Tank Pressure Control using Zero-Boil Off Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

zero boil-off↗

Modeling and Simulation of Tank Pressure Control using Zero-Boil Off Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

zero boil-off↗

Modeling and Simulation of Tank Pressure Control using Zero-Boil Off Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

Cameron J. Hines↗

Effect of Residual Noncondensables on Pressurization and Pressure Control of a Zero-Boil-Off Tank in Microgravity

The Zero-Boil-Off Tank (ZBOT) Experiment is a small-scale experiment that uses a transparent ventless Dewar and a transparent simulant phase-change fluid to study sealed tank pressurization and pressure control with applications to on-surface and in-orbit storage of propellant cryogens. The experiment will be carried out under microgravity conditions aboard the International Space Station in the 2014 timeframe. This paper presents preliminary results from ZBOT's ground-based research that focuses on the effects of residual noncondensable gases in the ullage on both pressurization and pressure reduction trends in the sealed Dewar. Tank pressurization is accomplished through heating of the test cell wall in the wetted and un-wetted regions simultaneously or separately. Pressure control is established through mixing and destratification of the bulk liquid using a temperature controlled forced jet flow with different degrees of liquid jet subcooling. A Two-Dimensional axisymmetric two-phase CFD model for tank pressurization and pressure control is also presented. Numerical prediction of the model are compared to experimental 1g results to both validate the model and also indicate the effect of the noncondensable gas on evolution of pressure and temperature distributions in the ullage during pressurization and pressure control. Microgravity simulations case studies are also performed using the validated model to underscore and delineate the profound effect of the noncondensables on condensation rates and interfacial temperature distributions with serious implications for tank pressure control in reduced gravity.

Marangoni and Natural Convection↗

CFD Jet Mixing Model Validation Against Zero-Boil-Off Tank (ZBOT) Microgravity Experiment

The Zero-Boil-Off Tank (ZBOT) experiments are a series of small scale two-phase fluids physics experiments conducted aboard the International Space Station (ISS) in 2017. A goal of these experiments is to study various fundamental fluid flow, heat and mass transport, and phase change phenomena that control storage tank pressurization and pressure control in microgravity. In this paper, results of a state-of-the-art two-phase CFD (Computational Fluid Dynamics) storage tank model are presented and validated against jet mixing data provided by microgravity ZBOT experiments. Jet-ullage interaction was studied in the experiment for different jet speeds representing different flow regimes, and tank fill levels. Effects of various physical parameters, such as, jet angle, gravitational acceleration and surface tension value were investigated. Computational parameters, such as turbulence and surface tension models and interface capturing scheme, affecting jet-ullage interaction were also studied. Computational results were compared to experimental results for model validation.

Turbulence↗

CFD Jet Mixing Model Validation against Zero-Boil-Off Tank (ZBOT) Microgravity Experiment

The Zero-Boil-Off Tank (ZBOT) experiments are a series of small scale two-phase fluids physics experiments conducted aboard the International Space Station (ISS) in 2017. A goal of these experiments is to study various fundamental fluid flow, heat and mass transport, and phase change phenomena that control storage tank pressurization and pressure control in microgravity. In this paper, results of a state-of-the-art two-phase CFD storage tank model are presented and validated against jet mixing data provided by microgravity ZBOT experiments. Jet-ullage interaction was studied in the experiment for different jet speeds representing different flow regimes, and tank fill levels. Effects of various physical parameters, such as, jet angle, gravitational acceleration and surface tension value were investigated. Computational parameters, such as turbulence and surface tension models and interface capturing scheme, affecting jet-ullage interaction were also studied. Computational results were compared to experimental results for model validation.

Mixing↗

Thermal Model of a Zero Boil Off System for the Nuclear Thermal Propulsion System

NASA is currently developing an updated concept for a nuclear thermal propulsion (NTP) system. To enable this concept, efficient thermal insulation and cryocooler heat exchanger systems are required to eliminate boil-off of propellant. This paper presents the results of a thermal model used to assess the feasibility of using active cooling with a tube-on-tank heat exchanger configuration for the inline tank of the NTP system. Results show that: cryocooler working fluid temperature and mass flow rate can be adjusted to achieve zero boil off (ZBO) with broad area cooling, over-sizing the cryocooler lift directly translates into a reduction in tank pressure, and broad area cooling may still maintain ZBO despite the reduced heat transfer between tank wall and propellant that is expected in reduced gravity.

zero boil off↗

Thermal Modeling of Zero Boil Off Tank Experiment

Understanding fluid behavior in microgravity environments is essential to further development of cryogenic storage in space environments. The Zero Boil Off Tank (ZBOT) experiment was designed to investigate two-phase pressurization and depressurization of a tank in a microgravity environment. The test fluid was the refrigerant Perfluoro-normal-Pentane (PNP). Thermal modeling for the ZBOT model was conducted using Thermal Desktop and SINDA/FLUINT. The temperature distribution within the fluid of the tank is of particular interest. This particular work is centered on ascertaining the thermal behavior of the refrigerant in order to build more complete models of fluid in microgravity. Separate cases were run modeling experiments that were conducted both on the ground and on the International Space Station (ISS) to compare 1g and microgravity environments. The microgravity modeling cases consisted of a fluid lump representing the vapor ullage suspended in a solid to represent the liquid. Mass flow between the liquid and vapor was modeled using the Schrage equation for mass flow. Initial results indicate that the pressure rise and temperature increase within the fluid closely align with the experimental data by matching initial conditions of the experiment. This work is ongoing and will yield further insights into the thermal behavior of fluid mixing in microgravity.

low-gravity fluid modeling↗

Zero-Boil-Off Tank (ZBOT) Experiment: Ground-Based Validation of Self-Pressurization and Pressure Control Two-Phase CFD Model

Integral to all phases of NASA's projected space and planetary expeditions is affordable and reliable cryogenic fluid storage for use in propellant or life support systems. Cryogen vaporization due to heat leaks into the tank from its surroundings and support structure can cause self-pressurization relieved through venting. This has led to a desire to develop innovative pressure control designs based on mixing of the bulk tank fluid together with some form of active or passive cooling to allow storage of the cryogenic fluid with zero or reduced boil-off. The Zero-Boil-Off Tank (ZBOT) Experiments are a series of small scale tank pressurization and pressure control experiments aboard the International Space Station (ISS) that use a transparent volatile simulant fluid in a transparent sealed tank to delineate various fundamental fluid flow, heat and mass transport, and phase change phenomena that control storage tank pressurization and pressure control in microgravity. The hardware for ZBOT-1 flew to ISS on the OA-7 flight in April 2017 and operations are planned to begin in September 2017, encompassing more than 90 tests. This paper presents preliminary results from ZBOT's ground-based research delineating both pressurization and pressure reduction trends in the sealed test tank. Tank self-pressurization tests are conducted under three modes: VJ heating, strip heating and simultaneous VJ and strip heating in attempt to simulate heat leaks from the environment, the support structure and both. The jet mixing pressure control studies are performed either from an elevated uniform temperature condition or from thermally stratified conditions following a self-pressurization run. Jet flow rates are varied from 2-25 cm/s spanning a range of jet Re number in laminar, transitional, and turbulent regimes and a range of Weber numbers covering no ullage penetration, partial penetration and complete ullage penetration and break-up (only in microgravity). Numerical prediction of a two-phase CFD model are compared to experimental 1g results to both validate the model and also indicate the effect of the residual non-condensable gas on evolution of pressure and temperature distributions in the tank during pressurization and pressure control.

microgravity evaporation condensatio↗

The Zero-Boil-Off Tank Experiment: the Effects of Non-Condensable Gases on Pressurization and Pressure Control of Propellant Tanks in Microgravity

Introduction Integral to all phases of NASA’s projected planetary expeditions is affordable and reliable cryogenic fluid storage for use in propellant or life support systems. It is greatly advantageous to develop innovative vent-less pressure control designs based on cooling/mixing of the bulk tank fluid to allow storage of the cryogenic fluid with zero or reduced boil-off. The presence of noncondensable gases, can interfere with the condensation at the interface impacting tank pressure control during subcooled jet mixing especially in microgravity. The Zero-Boil-Off Tank (ZBOT) Experiments are a series of small-scale experiments aboard the International Space Station (ISS) that use a transparent volatile simulant fluid in a transparent sealed tank to delineate various fundamental fluid flow, heat and mass transport, and phase change phenomena associated with storage tank pressurization and pressure control in microgravity. The ZBOT-1 experiment was performed on the ISS 2017-2018 timeframe and collected data to validate a state-of-the-art CFD model for tank pressurization and pressure control for a pure system. The ZBOT-NC Experiment is the second experiment in the series to be performed on the International Space Station (ISS) in 2025. Its goal is to investigate the effects of noncondensable gases on interfacial evaporation and condensation during self -pressurization and jet-mixing pressure control in microgravity for a two-component system. Materials & Methods In this work, we will describe the detailed features of the ZBOT-NC experimental hardware and Diagnostics that includes nonintrusive Quantum Dot Thermometry (QDT) for whole field temperature measurement. All microgravity pressurization and pressure control tests will be performed for both the pure and the two-components systems with Xenon and Neon as the two noncondensable gases spanning small and large molecular weights and sizes. The two-phase CFD model that is developed as part of the project will be also presented and discussed. Results Ground-based pressurization and jet mixing experiments and CFD simulation results are compared to each other to validate both the fidelity of the CFD model predictions and the accuracy of the QDT measurement. Model simulations for noncondensable gas effects will also be compared against large Cryogenic LH2-GHe experiments to indicate the noncondensable gas effects on tank pressure control during jet mixing in 1G. Finally, CFD results will be presented to predict the effects of the noncondensable gas during subcooled jet mixing during the ZBOT-NC in advance of the microgravity experiment in 2015.

Evaporation Condensation↗

Potential Follow on Experiments for the Zero Boil Off Tank Experiment

Cryogenic Storage &Transfer are enabling propulsion technologies in the direct path of nearly all future human or robotic missions; It is identified by NASA as an area with greatest potential for cost saving; This proposal aims at resolving fundamental scientific issues behind the engineering development of the storage tanks; We propose to use the ISS lab to generate & collect archival scientific data:, raise our current state-of-the-art understanding of transport and phase change issues affecting the storage tank cryogenic fluid management (CFM), develop and validate state-of-the-art CFD models to innovate, optimize, and advance the future engineering designs

Thermodynamics↗

SINDA/FLUINT and Thermal Desktop Multi-Node Settled and Unsettled Propellant Tank Modeling of Zero Boil Off Test

Cryogenic propellant storage tank self-pressurization involves complex physical phenomena which are usually analytically modelled via complex multidimensional CFD (Computational Fluid Dynamics) codes. Unfortunately these codes, even when modelling axisymmetric domains, may take weeks or longer to obtain transient pressure and temperature information for relatively short periods of time (several seconds to several hours). Propellant tank storage end-to-end mission simulations can last a duration of days to weeks to months. Multi-node modelling of propellant tanks is a viable alternative to traditional CFD modelling and presents the advantage of greatly reduced run times on the order of hours and days compared to the weeks or longer for CFD codes. A multi-node model represents the fluid within the storage tank, as well as the storage tank itself, as a fluid-thermal network. This type of setup is not necessarily geometrically based. This can be accomplished using a commercial generalized fluid-thermal network code, such as SINDA/FLUINT (SF). The advantage of using a fluid-thermal network code like SF lies in its extensive ability to model the external environment of the storage tank through the graphical user interface, Thermal Desktop (TD). The total heat load into the tank may be a function of heaters and a complex radiative environment as well. Thermal Desktop may be used to address the detailed radiative environment of the tank as well as building a geometrically accurate depiction of the storage tank itself.

Thermal Desktop↗

SINDA/FLUINT and Thermal Desktop Multi-Node Settled and Unsettled Propellant Tank Modeling of Zero Boil Off Test

Cryogenic propellant storage tank self-pressurization involves complex physical phenomena which are usually analytically modelled via complex multidimensional CFD codes. Unfortunately these codes, even when modelling axisymmetric domains, may takes weeks or longer to obtain transient pressure and temperature information for relatively short periods of time (several seconds to several hours). Propellant tank storage end-to-end mission simulations can last a duration of days to weeks to months. Multi-node modelling of propellant tanks is a viable alternative to traditional CFD modelling and presents the advantage of greatly reduced run times on the order of hours and days compared to the weeks or longer for CFD codes. A multi-node model represents the fluid within the storage tank, as well as the storage tank itself, as a fluid-thermal network. This type of setup is not necessarily geometrically based. This can be accomplished using a commercial generalized fluid-thermal network code, such as SINDA/FLUINT (SF). The advantage of using a fluid-thermal network code like SF lies in its extensive ability to model the external environment of the storage tank through the graphical user interface, Thermal Desktop (TD). The total heat load into the tank may be a function of heaters and a complex radiative environment as well. Thermal Desktop may be used to address the detailed radiative environment of the tank as well as building a geometrically accurate depiction of the storage tank itself.

Sakowski, Barbara↗

Zero Boil-Off Tank (ZBOT) Experiment

The Zero-Boil-Off Tank (ZBOT) experiment has been developed as a small scale ISS experiment aimed at delineating important fluid flow, heat and mass transport, and phase change phenomena that affect cryogenic storage tank pressurization and pressure control in microgravity. The experiments use a simulant transparent low boiling point fluid (PnP) in a sealed transparent Dewar to study and quantify: (a) fluid flow and thermal stratification during pressurization; (b) mixing, thermal destratification, depressurization, and jet-ullage penetration during pressure control by jet mixing. The experiment will provide valuable microgravity empirical two-phase data associated with the above-mentioned physical phenomena through highly accurate local wall and fluid temperature and pressure measurements, full-field phase-distribution and flow visualization. Moreover, the experiments are performed under tightly controlled and definable heat transfer boundary conditions to provide reliable high-fidelity data and precise input as required for validation verification of state-of-the-art two-phase CFD models developed as part of this research and by other groups in the international scientific and cryogenic fluid management communities.

ISS↗

Terrestrial Applications of Zero Boil-Off Cryogen Storage

Storing cryogenic propellants with zero boil off (ZBO) using a combination of active (cryocoolers) and passive technologies has recently received a great deal of attention for applications such as future long-term space missions. This paper will examine a variety of potential near-term terrestrial applications for ZBO and, where appropriate, provide a rough order of magnitude cost benefit of implementing ZBO technology. NASA's Space Shuttle power system uses supercritical propellant tanks, which are filled several days before launch. If the launch does not occur within 48-96 hours, the tanks must be drained and refilled, further delaying the launch. By implementing ZBO, boil off could be eliminated and pad hold time extended. At the launch site, vented liquid hydrogen (LH2) storage dewars lose 1200-1600 gal/day through boiloff. Implementing ZBO would eliminate this, saving $300,000-$400,000 per year. Similarly, overland trucking of LH2 from the supplier to the launch site via roadable dewars results in a cryogen loss of ten percent per tanker (1500 gal/tanker). Providing a cryocooler on board the rig would prevent this loss. Previous work investigating variable density insulation found that a 50% reduction in evaporation from a 6000 gallon dewar would save $5000 per year. For a 20 year dewar lifetime, the payback period would be less than two years. Similar benefits could be realized at other storage facilities across the nation. Within the superconductivity community, there is skepticism about using coolers, based upon reliability concerns. By providing a cooler on the dewar, lifetime could be extended while retaining fail-safe capability. If the cooler failed, it would merely lower the storage life of the dewar.

Salerno, L. J.↗

Results of an Advanced Development Zero Boil-Off Cryogenic Propellant Storage Test

A zero boil-off (ZBO) cryogenic propellant storage concept was recently tested in a thermally relevant low-earth orbit environment, an important development in the effort to apply this concept to flight projects. Previous efforts documented the benefits of ZBO for launch vehicle upper stages in a low-earth orbit (LEO). Central to that analysis is a ZBO Cryogenic Analysis Tool that estimates the performance of each component and the ZBO system. This test is essential to the validation of that tool, and was the first flight representative configuration tested in a thermally representative environment. The test article was comprised of a spherical 1.4 m diameter insulated propellant tank, with a submerged mixer, a cryogenic heat pipe, flight design cryocooler, and a radiator. All were enclosed in a thermal shroud and inserted into and tested in a vacuum chamber that simulated an LEO thermal environment. Thermal and pressure control tests were performed at sub-critical LN2 temperatures and approximately 2 atmospheres pressure. The cold side of the ZBO system performed well. In particular, the heat pipe performed better than expected, which suggests that the cryocooler could be located further from the tank than anticipated, i.e. on a spacecraft bus, while maintaining the desired efficiency. Also, the mixer added less heat than expected. The tank heating rate through the insulation was higher than expected; also the temperatures on the cryocooler hot side were higher than planned. This precluded the cryocooler from eliminating the boil-off. The results show the cryocooler was successful at removing 6.8 W of heat at approximately 75 K and 150 W of input power, with a heat rejection temperature of 311 K. The data generated on the ZBO components is essential for the upgrade of the ZBO Cryogenic Analysis Tool to more accurately apply the concept to future missions.

Plachta, David↗