Search NASA⌕ Search

SEARCH · Search NASA

Results for “Zero Power Physics Reactor (ZPPR) plates”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Rossi-α Measurements on a System Consisting of Weapons Grade Plutonium Moderated by Polyethylene [Poster]

A series of experiments nicknamed "TEX," standing for Thermal-Epithermal eXperiments, were performed at the National Criticality Experiments Research Center (NCERC) on the Planet critical assembly. The TEX experiment campaigns are a collaboration between Los Alamos National Laboratory (LANL) and Lawrence Livermore National Laboratory (LLNL) and funded by the Nuclear Criticality Safety Program (NCSP). The TEX experiment consists of several campaigns; this work specifically discusses measurements made on one series of TEX experiments designed to examine the thermal scattering law (TSL) for polyethylene. This series consisted of two different critical configurations which contain plutonium fuel. The plutonium plates are 2 in. by 3 in. by 0.125 in. Zero Power Physics Reactor (ZPPR) plates and are placed in a tray in an array of 6 plates by 4 plates wide creating a 12 in. by 12 in. square. These trays of plutonium are interleaved between polyethylene plates. These measurements differ from previous TEX experiments in that they examine a more thermal neutron spectrum than previously examined by interleaving much thicker interstitial moderating plates than the previous measurements. The two configurations differ in the thickness of polyethylene between the fissile material. While the experiment was designed to examine the TSL, this work only examines the results of Rossi-α measurements on the two different configurations. For both configurations, Rossi-α measurements were performed to experimentally validate the neutron spectrum.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Benchmark of the Chlorine Worth Study Experiments in Support of Chlorine Nuclear Data Validation for Nuclear Criticality Safety

The Chlorine Worth Study (CWS) was a critical experiment to address an urgent need for thermal chlorine nuclear data validation in plutonium systems. This urgent need is tied directly to plutonium recycle and recovery operations in the plutonium facility at Los Alamos National Laboratory, where exceptionally conservative criticality safety limits are used because no credit is taken for the neutron capture by chlorine. The experiment used weapons-grade plutonium metal plates clad in stainless steel, known as the PANN (plutonium aluminum no nickel) ZPPR (zero power physics reactor) plates. The plutonium was reflected and moderated by high-density polyethylene and included combinations of polyvinyl chloride (PVC) and chlorinated polyvinyl chloride (CPVC) as absorbers. The experiment and benchmark included three configurations mimicking 30 g 239 Pu/L plutonium, 300 g 239 Pu/L plutonium, and 600 g 239 Pu/L plutonium in an aqueous chloride solution. Uncertainties in the benchmark included five broad categories: (1) criticality measurement, (2) mass and density, (3) dimensions, (4) material compositions, and (5) positioning. The largest contribution to the overall uncertainties for all three cases came from the material compositions, in particular the PVC and CPVC absorber compositions. A detailed model was created to be a near match (that is within expectations of transport code users) and a simplified model was created to minimize offset dimensions and expedite modeling for code validation. Sample calculations were completed in MCNP6.3 with ENDF/B-VIII.0 and ENDF/B-VII.1 nuclear data. For the detailed and simplified models, the average difference between the computed and experimental k eff was 951 pcm. CWS will serve as the key validation experiment for nuclear criticality safety in support of aqueous chloride operations. The sensitivity to the chlorine capture cross section is orders of magnitude greater than other existing benchmarks. The current limits, as defined by nuclear criticality safety, are 520 g Pu per batch, i.e. the minimum critical mass of the Pu solution infinitely reflected by water [Criticality Handbook: Volume II, (1969)]. This extremely conservative critical mass limit does not credit any neutron capture by chlorine (in particular neutron capture by 35 Cl) and greatly impedes the throughput required for current and future operations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Final design for thermal epithermal experiments (TEX) with ZPPR plutonium/aluminium plates with polyethylene and tantalum - 13592

Lawrence Livermore National Laboratory has completed the final design for the first phase of the Thermal Epithermal experiments (TEX), which focused on critical configurations composed of plutonium/aluminum Zero Power Physics Reactor (ZPPR) plates moderated by polyethylene with and without a tantalum diluent. {sup 239}Pu and {sup 240}Pu were identified as being the number one and two nuclear data need by the nuclear criticality safety and nuclear data communities, with special emphasis placed on performance issues of the Pu cross sections in the intermediate energy region. Preliminary TEX design recommended tantalum as the first diluent to pursue for final design, as it represented a high priority data need, showed the highest sensitivity and largest contribution to uncertainty with the Pu ZPPR system, and a large number of high quality Ta plates from the ZPPR inventory in Idaho was readily available. The goals of the new critical experiments are 1) to create assemblies that span a wide range of fission energy spectra, from thermal (below 0.625 eV), through the intermediate (0.65 eV to 100 keV), and to fast energies (above 100 keV), and 2) to easily modify the assemblies to include high priority materials like tantalum. A total of ten critical configurations were designed as part of CED-2. Five TEX experiments (Experiments 1-5) were designed to establish baseline configurations with the Pu ZPPR plates covering the thermal, intermediate, and fast fission energy regimes. For all five experiments, the ZPPR plates will be arranged in layers of 24 plates (6 plates by 4 plates), resulting in approximately a 12 inch by 12 inch footprint. Multiple layers will be stacked together with varying thicknesses of interspersed polyethylene placed between the layers to fine tune the neutron spectrum of the assembly. The other five experiments (Experiments 6-10) will be similar to the five baseline experiments, except that a tantalum layer will be placed next to each plutonium plate layer, thus diluting the stack and allowing for tests of the neutron cross section for tantalum. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Developing a New Criticality Safety Hands-On Training Utilizing ZPPR Plates

Nuclear criticality safety is an extremely important part of the work at Los Alamos National Laboratory (LANL). As part of the work LANL performs to continue to keep criticality safety a top priority, LANL has developed and regularly teaches nuclear criticality safety training classes for both the United States Department of Energy Nuclear Criticality Safety Program as well as internal trainings for LANL employees. A portion of the training classes is comprised of hands-on demonstrations, where students get the opportunity to handle special nuclear material at the National Criticality Experiments Research Center (NCERC). One hands-on demonstration uses the “Class foils,” thin HEU foils which are stacked with lucite moderator plates. A hand-stack is performed until the multiplication reaches the “three-quarters rule,” where the demonstration is continued remotely on a vertical lift assembly up until the system is critical. This hands-on demonstration eventually achieves a critical configuration and follows the ANS-1 guidelines on an approach to critical. Another hands-on demonstration involves handling clad plutonium and neptunium spheres, and follows procedures using criticality safety evaluations to ensure that the hands-on demonstrations remain subcritical.This hands-on demonstration also involves the use of polyethylene shells around the plutonium sphere to demonstrate how additional reflector increases the criticality of a system. This paper is focused on developing a new hands-on demonstration using Zero Power Physics Reactor (ZPPR) plates. This new hands-on demonstration will follow the ANS-8 standards as it is not desired to achieve criticality with the ZPPR plates during the hands-on demonstration. A hands-on demonstration using multiple plutonium parts will likely be more applicable to personnel who handle plutonium on a daily basis, such as LANL glovebox operators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data Testing of Polyethylene Thermal Scattering Law with New Thermal Epithermal eXperiments (TEX) Plutonium Baseline Benchmark, PU-MET-MIXED-002

Five plutonium baseline experiments completed in September of 2018 from the Thermal Epithermal eXperiments (TEX) program have been accepted by the International Criticality Safety Benchmark Evaluation Project as PU-MET-MIXED-002 and will be included in the 2020 version of the handbook. The experiments were made up of stacked layers of plutonium Zero Power Physics Reactor (ZPPR) plates moderated by polyethylene (PE, chemical formula C2H4) to varying degrees to create configurations with five different neutron spectra, including one fast configuration, one thermal configuration, and three mixed configurations. Calculations of the benchmark show overprediction of k eff when using the most recent release of the Evaluated Nuclear Data File Version B (ENDF/B) library release (VIII.0) cross sections, particularly when compared to the previous ENDF/B-VII.1 results. One potential source of overprediction was hypothesized to be the new Molecular Dynamics (MD) generated PE Thermal Scattering Law (TSL). The overprediction was shown via calculation to not be caused by the new ENDF/B-VIII.0 thermal scattering law, and in fact the overprediction was mitigated by the new PE TSL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Integral Experiment Execution of Thermal or Epithermal eXperiments using Plutonium with Polyethylene and Iron, IER 519, TEX-Hanford (-Iron), CED-3b

This report documents the execution of experiments and measurements for IER 519, Thermal/Epithermal eXperiments (TEX) for Hanford applications, using plutonium Zero Power Physics Reactor (ZPPR) plates moderated by interstitial polyethylene and iron (Fe) absorber plates. Initial hand stack, mass, and dimensional measurements were performed in July 2025. The experiments were completed over three weeks from December 2025 to January 2026 at the National Criticality Experiments Research Center (NCERC) at the Nevada National Security Sites (NNSS). All photos and critical data were provided by NCERC and experimenters in LANL’s NEN-2.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IER-297 CED-2: Final Design for Thermal/Epithermal eXperiments with Jemima Plates with Polyethylene and Hafnium

This report presents the final design (CED-2) for IER-297, and focuses on 15 critical configurations using highly enriched uranium (HEU) Jemima plates moderated by polyethylene with and without hafnium diluent. The goal of the U.S. Nuclear Criticality Safety Program’s Thermal/Epithermal eXperiments (TEX) is to design and conduct new critical experiments to address high priority nuclear data needs from the nuclear criticality safety and nuclear data communities, with special emphasis on intermediate energy (0.625 eV – 100 keV) assemblies that can be easily modified to include various high priority diluent materials. The TEX (IER 184) CED-1 Report [1], completed in 2012, demonstrated the feasibility of meeting the TEX goals with two existing NCSP fissile assets, plutonium Zero Power Physics Reactor (ZPPR) plates and highly enriched uranium (HEU) Jemima plates. The first set of TEX experiments will focus on using the plutonium ZPPR plates with polyethylene moderator and tantalum diluents.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Integral Experiment Final Design for Thermal/Epithermal eXperiments (TEX) using Highly Enriched Uranium with Polyethylene at Low Temperature (IER-479 CED-2 Report)

The goal of IER-479 is to design uranium critical experiments that can be used to validate low temperature cross sections and criticality safety analyses over multiple neutron energy regimes. Currently, there are no benchmarks in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) handbook at temperatures lower than room temperature (International Criticality Safety Benchmark Evaluation Project Handbook, 2019). However, there are many needs for validation of criticality safety analysis at lower temperatures, including meeting transportation requirements and operations conducted outside or in unheated facilities. Additionally, NCSP has funded North Carolina State (NCSU) to generate new thermal scattering laws, including at lower temperatures, and the lack of integral benchmarks impedes data testing of these new cross sections. To address these needs, this report will present a critical experiment design covering various fission energy regimes with a goal temperature of -40°C (-40°F), which is based on the lower bound of expected non-cryogenic operational temperatures. The goal of the U.S. Nuclear Criticality Safety Program’s (NCSP) Thermal/Epithermal eXperiments (TEX) is to design and conduct new critical experiments to address high priority nuclear data needs from the nuclear criticality safety and nuclear data communities. The TEX program includes two series of baseline experimental configurations, one based on plutonium fuel (plutonium-aluminum Zero Power Physics Reactor (ZPPR) plates) and the other based on uranium fuel (highly enriched uranium (HEU) plates), that are moderated with varying thickness of polyethylene to create assemblies which span the thermal, intermediate, and fast fission energy regimes. The configurations are designed to be easily modified (for example, to add diluent materials of interest) to allow for efficient generation of additional benchmark configurations and allow for added nuclear data testing utility when comparing modified configurations to baseline configurations. The goal of IER-479 is to use the TEX-HEU concept (stack of HEU plates and polyethylene moderators) to design a critical experiment that can be used to validate low temperature cross sections and criticality safety analyses.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Criticality Experiments to Reduce Compensating Errors in Plutonium Nuclear Data

Compensating errors between nuclear data observables in a library can adversely impact application simulations. The primary goal of the EUCLID project (Experiments Underpinned by Computational Learning for Improvements in Nuclear Data) is to reduce compensating errors in nuclear data. A new criticality experiment, described in this work, was designed with the specific target nuclear data of 239 Pu fission, inelastic scattering, elastic scattering, capture, nu-bar, and prompt fission neutron spectrum (PFNS). This work will focus on the design and execution of the EUCLID experiment, performed on the Planet vertical lift critical assembly machine at the National Criticality Experiments Research Center (NCERC). The criticality experiment includes two different configurations with very different geometries: one is cube-like to minimize neutron leakage while the other is slab-like to maximize leakage. Having these two widely varying configurations allows the scattering sensitivities of 239 Pu to the neutron multiplication factor to be greatly changed while minimally impacting the other cross section sensitivities. Both configurations utilize the Pu ZPPR (Zero Power Physics Reactor) plates as fuel. The experiments were designed using a D-Optimality criteria, which is an optimization method minimizing the log-determinant of the adjusted nuclear data covariance for the target reactions. These experiments include not only inference of k eff , as done in all critical benchmark experiments, but several other responses as well, such as neutron multiplication measurements and reaction rate ratios. After analysis of the measured data is complete, adjustment of nuclear data will be performed to assess whether the new experimental data successfully reduced compensating errors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Rossi-alpha Analysis of Thermal/Epithermal eXperiments Optimized for Polyethylene Thermal Neutron Scattering

Accurate nuclear data is the foundation for predictive simulations and design of new experimental in the nuclear community. The criticality safety community has particular interest in benchmarking assemblies with thermal neutron data. To address such needs the Nuclear Criticality Safety Program (NCSP) funded the Thermal/Epithermal eXperiments (TEX) campaigns that were to be completed between Lawrence Livermore National Laboratory (LLNL) and Los Alamos National Laboratory (LANL). Specifically, analysis of plutonium with a thermal neutron spectrum expands on previous work to help validate thermal scattering law data, which can have larger impacts in thermal applications. The first of these experiments were successfully conducted in 2018, but this paper will focus on the 2021 measurement focused on investigating the the thermal scattering law (TSL) for polyethylene. These experiments were successfully conducted at the National Criticality Experiments Research Center (NCERC) using the Planet vertical lift critical assembly machine. Polethylene plates were layered with trays of Zero Power Physics Reactor (ZPPR) 24 plates in a 12" by 12" square. The ZPPR plates were 2" by 3" by 0.125" bearing weapons grade plutonium. The polyethylene moderator was either 2" or 1.6875" thick. This work builds on the Rossi-alpha calculations done by McKenzie et al. for the same detector-assembly system and will only focus on the Rossi-alpha neutron noise method. This work will aim to further validate the results of the experiment through a novel neutron noise python package. Following similar methodology to the previous analysis, analysis of TEX evaluated the prompt neutron decay constant at delayed critical, $α_{DC}$ using Rossi-alpha for different polyethylene moderator thicknesses. These results will help improve understanding of TSL in critical experiments. Alpha (α), is the prompt neutron decay constant of the measured system and allows for the evaluation of a systems propensity to sustain fission chains via prompt neutrons. The single value description of the assemblies allow for comparison between experiments regardless of composition, geometry, and reflectors/moderators. Rossi-alpha measurements were performed on the polyethylene moderated TEX experiments to estimate $α_{DC}$.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Preliminary Chlorine Worth Study Benchmark Evaluation

The Chlorine Worth Studies (CWS) experiments with polyvinyl chloride (PVC with chemical formula (C 2 H 3 Cl) n ), chlorinated polyvinyl chloride (CPVC with chemical formula (C 9 H 11 Cl 7 ) n ), and high density polyethylene (HDPE with chemical formula (CH 2 ) n ) were a series of measurements performed at the National Criticality Experiments Research Center (NCERC). The purpose of the CWS experiments was to perform integral experiments that were highly sensitive to the thermal 35 Cl(n,γ) reaction and matched the sensitivities of aqueous chloride operations at the plutonium facility at Los Alamos National Laboratory (LANL). The CWS experiments were performed on the Planet critical assembly machine at NCERC and utilized weapons grade plutonium (WGPu) plates as fuel. The design process and design of the CWS experiment were discussed previously. This paper discusses the benchmark evaluation of the experiment, intended for the International Criticality Safety Benchmark Evaluation Project (ICSBEP). Criticality calculations were performed with MCNP version 6.3. Results presented here are preliminary, as the benchmark has not yet been submitted to the ICSBEP.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

IER 519 Experiment Execution Report: TEX Hanford

The TEX-Hanford experiments were performed at the National Criticality Experiments Research Center (NCERC) at the Device Assembly Facility (DAF) at the Nevada Nuclear Security Site (NNSS). Three configurations were measured, with the measurements occurring in December 2025 and January 2026. The Fe-14 configuration was executed in December 2025; the Fe-11 configuration began its handstack on the Planet critical assembly machine in December 2025, but was taken critical in January 2026; the Fe-16 configuration was executed entirely in January 2026. The TEX-Hanford experiments were performed on the Planet critical assembly machine utilizing using PANN (Plutonium Aluminum No Nickel) ZPPR (Zero Power Physics Reactor) plutonium plates as fuel. The configurations were moderated with varying thicknesses of HDPE and iron absorber. This document details the configurations that were measured, preliminary reactivity measurements of the measured configurations, data files from the neutron detection systems, and results from the coordinate-measuring machine (CMM) measurements of the final stack height measurements each configuration.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design Optimization for EUROPA Critical Experiment

The Experiment for Unresolved Region Of Plutonium Actinides (EUROPA) is an integral critical experiment currently being designed to target the intermediate energy region of plutonium. Intermediate energies, those between 0.625 eV - 100 keV, contain the end of resolved and beginning of the unresolved resonance region, making experiments in this energy range prudent for validating the representation of cross sections in this transition region. Below is the preliminary design of the experiment to be performed at the National Criticality Experiments Research Center (NCERC). Experiment optimization required an exhaustive down selection of several moderating, absorbing, and reflecting materials using Particle Swarm Optimization (PSO) in order to achieve maximum sensitivity to the intermediate energy region.

07 ISOTOPE AND RADIATION SOURCES↗

Systematic Measurements and Analyses for Lead Void Reactivity Worth in a Plutonium Core and Two Uranium Cores with Different Enrichments

To validate lead (Pb) nuclear cross sections, a series of integral experiments to measure lead void reactivity worth was conducted systematically in three fast neutron spectra with different fuel compositions on the Comet critical assembly of the National Criticality Experiments Research Center. Previous experiments in high-enriched uranium (HEU)/Pb and low-enriched uranium (LEU)/Pb systems had been performed in 2016 and 2017, respectively. A follow-on experiment in a plutonium (Pu)/Pb system has been completed. The Pu/Pb system was constructed using lead plates and weapons-grade Pu plates that had been used in the Zero Power Physics Reactor (ZPPR) of Argonne National Laboratory until the 1990s. Furthermore, the HEU/Pb system was reexamined on the Comet critical assembly with a newly installed device that can measure the compression of the stack, improving reproducibility. Using the lead void reactivity worth measured in these three cores with different fuel compositions, the latest nuclear data libraries, JENDL-4.0 and ENDF/B-VIII.0, were tested with the Monte Carlo calculation code MCNP® version 6.1. As a result, the calculations by ENDF/B-VIII.0 were confirmed to agree with lead void reactivity worth measured in all the cores. It was furthermore found that the calculations by JENDL-4.0 overestimate by more than 20% for the Pu/Pb core while being in good agreement for the HEU/Pb and LEU/Pb cores.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Radiography and Fission Mapping Measurements of Nuclear Materials with Varying Composition and Shielding

Neutron radiography and fission mapping measurements were performed on four measurement objects with varying composition and shielding arrangements at the Idaho National Laboratory's Zero Power Physics Reactor (ZPPR) facility. The measurement objects were assembled with ZPPR reactor plate materials comprising plutonium, natural uranium, or highly enriched uranium and were presented as unknowns for characterization. As a part of the characterization, neutron radiography was performed using a deuterium-tritium (D-T) neutron generator as a source of time and directionally tagged 14 MeV neutrons. The neutrons were detected by plastic scintillators placed on the opposite side of the object, using the time-correlation-based data acquisition of the Nuclear Materials Identification System developed at Oak Ridge National Laboratory. Each object was measured at several rotations with respect to the neutron source to obtain a tomographic reconstruction of the object and a limited identification of materials via measurement of the neutron attenuation. Large area liquid scintillators with pulse shape discrimination were used to detect the induced fission neutrons. A fission site map reconstruction was produced by time correlating the induced fission neutrons with each tagged neutron from the D-T neutron generator. This paper describes the experimental configuration, the ZPPR measurement objects used, and the neutron imaging and fission mapping results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

PU-MET-MIX-002, TEX Pu Baseline Assemblies

This report documents the plutonium baseline experimental critical configurations for the United States Nuclear Criticality Safety Program’s Thermal/Epithermal eXperiments (TEX) program. Five TEX experiments (Experiments 1-5) were designed to establish baseline configurations with plutonium/aluminum metal alloy Zero Power Physics Reactor (ZPPR) Plutonium-Aluminum No-Nickel (PANN) plates covering five different fission energy regimes, with varying fractions of thermal, intermediate, and fast fissions. All five experiments are acceptable as benchmarks. As the neutron spectra of the five experiments differed, Case 1 is cross listed as PU-MET-FAST-048 and Cases 4 and 5 are cross listed as PU-MET-THERM-002. For all five experiments, the ZPPR plates were arranged on trays in layers of 24 plates (6 plates by 4 plates), resulting in approximately a 30 cm by 30 cm footprint. Multiple layers were stacked together with varying thicknesses of interspersed polyethylene placed between the layers to tune the neutron spectrum of the assembly. The experiments were completed in multiple campaigns over 2017 and 2018 at the National Criticality Experiments Research Center (NCERC) at the Nevada National Security Site (NNSS).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Integral Experiment Final Design for Thermal/Epithermal eXperiments (TEX) Plutonium Additional Mixed Spectrum Configurations

This report presents the final design (CED-2) for three additional mixed-spectra configurations for plutonium Thermal/Epithermal eXperiments (TEX) to target the intermediate energy region (IER-553). The baseline cases of IER-184 (PU-MET-MIXED-002 [2]) spanned the entire fission energy spectrum. Case 3, which had a median fission energy (MFE) of approximately 6E-5 MeV and had a fission fraction of about 42% in the intermediate energy range, resulted in a $k_{eff}$ overestimation of 1.1%. Compared to 749 previous ICSBEP plutonium benchmarks, the baseline cases accurately predicted the experiments in the thermal and fast regions where the majority of benchmarks inhabit. The benchmarks in the intermediate energy region to date are sparse and overestimate $k_{eff}$ with an average C/E between 1.02 and 1.03. The additional proposed configurations span the whole of the intermediate energy region. The experimental design utilizes the plutonium/aluminum metal alloy Zero Power Physics Reactor (ZPPR) Plutonium-Aluminum No-Nickel (PANN) plates with varying polyethylene moderator thicknesses to span the intermediate fission energy region. Each of the cases have varying fractions of thermal, intermediate, and fast fissions. The designs were chosen to maximize the intermediate energy fraction. The experiment will take place on the universal critical assembly machine, Planet. The layers will be split as equally as possible between the lower platen and the upper stationary platform of Planet. The upper half of the experimental configuration will also have an upper reflector of polyethylene of specified thicknesses to achieve criticality when the lower platen is raised fully. The previous IER-184 configurations, specifically Case 3, were used to determine the configurations for the additional experiments and neutronics calculations were used to fine-tune the configurations to ensure criticality. The quadrature sum uncertainty in Δ$k_{eff}$ for Case 3 in PU-MET-MIXED-002 was found to be 0.00219. Section 3.8 gives a detailed description of the uncertainties calculated. The additional configurations, which are based directly on Case 3, are expected to have similar uncertainties. However, it is possible to reduce the overall uncertainty of Δ$k_{eff}$ for the additional configurations using the knowledge obtained from the calculations in the benchmark.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pulsed, Photonuclear-induced, Neutron Measurements of Nuclear Materials with Composite Shielding

Active measurements were performed using a 10-MeV electron accelerator with inspection objects containing various nuclear and nonnuclear materials available at the Idaho National Laboratory’s Zero Power Physics Reactor (ZPPR) facility. The inspection objects were assembled from ZPPR reactor plate materials to evaluate the measurement technologies for the characterization of plutonium, depleted uranium or highly enriched uranium shielded by both nuclear and non-nuclear materials. A series of pulsed photonuclear, time-correlated measurements were performed with unshielded calibration materials and then compared with the more complex composite shield configurations. The measurements used multiple 3He detectors that are designed to detect fission neutrons between pulses of an electron linear accelerator. The accelerator produced 10-MeV bremsstrahlung X-rays at a repetition rate of 125 Hz (8 ms between pulses) with a 4-us pulse width. All inspected objects were positioned on beam centerline and 100 cm from the X-ray source. The time-correlated data was collected in parallel using both a Los Alamos National Laboratory-designed list-mode acquisition system and a commercial multichannel scaler analyzer. A combination of different measurement configurations and data analysis methods enabled the identification of each object. This paper describes the experimental configuration, the ZPPR inspection objects used, and the various measurement and analysis results for each inspected object.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗