Search NASA⌕ Search

SEARCH · Search NASA

Results for “Zero valent iron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Removal of As(V) from wastewaters using magnetic iron oxides formed by zero-valent iron electrocoagulation

Electrocoagulation of zero-valent iron has been widely applied to the removal of dissolved arsenic, but the solid-liquid separation of arsenic-containing precipitates remains technically challenging. In this work, zero-valent iron was electrochemically oxidized to magnetic iron oxides for the removal of As(V) from simulated and actual mining wastewaters. The results indicated that lepidocrocite was formed when zero-valent iron was oxidized by dissolved oxygen, but ferrihydrite and green rust were first formed and then transformed to magnetic iron oxides (mainly magnetite and maghemite) in the electrochemical oxidation from 0 to 0.9 V (vs. SCE), which facilitates the adsorption of As(V) and subsequent solid-liquid separation under a magnetic field. In simulated As(V)-containing solution with initial pH 7.0, zero-valent iron was electrochemically oxidized to magnetite and maghemite at 0.6 V (vs. SCE) for 2 h. The As(V) concentration first decreased from 5127.5 to 26.8 μg L -1 with a removal ratio of 99.5%. In actual mining wastewaters, zero-valent iron was electrochemically oxidized to maghemite at 0.6 V (vs. SCE) for 24 h, and the As(V) concentration decreased from 5486.4 to 3.6 μg L -1 with a removal ratio of 99.9%. The removal ratio of As(V) increased slightly with increasing potential, and increased first and then decreased with increasing initial pH. Compared with that of SO 4 2- and NO 3 - , the presence of Cl - significantly enhanced the removal of As(V). This work provides a highly efficient, facile and low-cost technique for the treatment of arsenic-containing wastewaters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mechanistic insights into sulfate and phosphate-mediated hexavalent chromium removal by tea polyphenols wrapped nano-zero-valent iron

Nano zero-valent iron via green synthesis (g-nZVI) has great potential in removing toxic hexavalent Cr(VI) from industrial wastewater. Sulfate and phosphate in wastewater can influence Cr(VI) removal by g-nZVI. Here, in this study, the Cr(VI) removal kinetics by different g-nZVI materials were investigated with the existence of sulfate and/or phosphate, and the corresponding mechanisms were first revealed using multiple characterizations, including X-ray absorption near-edge spectra (XANES) and X-ray photoelectron spectroscopy (XPS). The results showed that Cr(OH) 3 was the dominant species initially formed on the surface of g-nZVI particles before transforming to Cr 2 O 3 during the reaction of g-nZVI with Cr(VI). Sulfate in wastewater can promote the reduction from Cr(VI) to Cr(OH) 3 by g-nZVI, because sulfate triggers the release of Fe(II) and tea polyphenols (from tea extracts) from the g-nZVI surface due to the corrosion of Fe 0 core, which is in line with an obvious increase in pseudo-second-order rate constant (k 2 ) and subtle change in Cr(VI) removal capacity (q e ). However, phosphate impedes the g-nZVI corrosion and inhibits q e because of the inner-sphere complexation of phosphate onto g-nZVI decreasing the released Fe(II) for Cr 2 O 3 production. When sulfate and phosphate coexisted in contaminated water, the inhibition effect of phosphate in Cr(VI) removal by g-nZVI was stronger than the promotion of sulfate. Accordingly, q e value of g-nZVI declined from 93.4 mg g –1 to 77.5 mg g –1 , while k 2 remained constant as the molar ratio of phosphate/sulfate increased from 0.1 to 10 in water. This study provides new insights into applying g-nZVI in efficient Cr(VI) removal from contaminated water with enrichment of sulphates and phosphates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High‐efficiency adsorption of various heavy metals by tea residue biochar loaded with nanoscale zero‐valent iron

Abstract Nanoscale zero‐valent iron (nZVI) loaded on tea residue biochar activated with phosphoric acid composites was synthesized. This adsorbent can efficiently adsorb multiple heavy metal ions such as Pb (II), Cr (III), Cu (II), and Ni (II) simultaneously. The adsorption process was found to follow the pseudo‐second‐order kinetic model. Equilibrium adsorption capacities reached 288.18, 162.34, 242.72, and 267.22 mg·g −1 for Pb(II), Cr(III), Cu(II), and Ni(II), respectively. The common interfering ions exhibited lower influence on its adsorption capacity. The adsorption mechanism includes reduction, ion exchange, surface complexation and precipitation. Furthermore, the waste adsorbent was converted into a catalyst in situ, which could catalyze the degradation of Congo red by establishing an electron transfer pathway. This research provides a new concept for the sustainable utilization of industrial tea residues and the harmless treatment of waste nZVI composite adsorbents.

Liu, Shuang↗

Impact of zero valent iron aging on reductive removal of technetium-99

Zero valent iron (ZVI) is a promising material for reductive removal of technetium from industrial waste streams. An example application of this method could be to treatment of low activity aqueous waste that is currently stored in tanks at the Hanford site. However, there is still a lack of understanding of the useful lifetime of ZVI for treatment and the changes in reductive removal of Tc over time. In this research, we studied the reductive removal of Tc from aqueous solutions by ZVI aged with up to 30 days by contact with 0.08 M NaCl solutions. These results show that ZVI could be used to remove Tc(VII) from aqueous solutions by its reduction to the less soluble and relatively immobile Tc(IV) with greater than 99% removal in three hours. Still, greater than 90% of Tc is removed with ZVI aging up to one week. However, after 10 days of aging of zero valent iron, a significant decrease in removal of Tc occurs (55% removal at three hours) followed by negligible removal after aging for two weeks or more which is consistent with formation of iron oxides on the surface. Further, these results correlate with XRD and FTIR analysis showing an increase in magnetite followed by maghemite and goethite with aging time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Zero-Valent Iron Permeable Reactive Barrier to Remediate Volatile Organic Compounds in Groundwater - 20209

The US DOE-SRS, the US EPA, and the South Carolina Department of Health and Environmental Control determined it was appropriate to perform a non-time critical removal action at the P-Area Groundwater Operable Unit at the SRS to reduce the mass and downgradient transport of trichloroethylene in the P-Area groundwater plume. Contaminated groundwater discharges to a nearby stream, Steel Creek, within the SRS boundaries, resulting in trichloroethylene concentrations above the maximum contaminant level. Impact to surface water is limited in areal extent and supported by recently collected characterization data. The P-Area Groundwater Operable Unit encompasses the groundwater beneath an industrial area within SRS, P Area, where the P-Reactor once operated. The boundaries of the P-Area Groundwater Operable Unit extend northwest to Steel Creek, northeast toward PAR Pond, and southeast to Meyers Branch. Groundwater in the Upper Three Runs Aquifer of the P-Area Groundwater Operable Unit has been impacted by reactor and facility operations between 1954 and 1991, including tritium and volatile organic compounds. The P-Area surface units contributing to groundwater contamination were remediated as part of the P-Area Operable Unit in 2011. The P-Reactor closure is one of the first of its kind in the DOE Complex and is one of only a few full-sized production reactors in the US to undergo completion of final closure activities. The nature and extent of groundwater contamination was determined using a variety of investigative approaches such as groundwater monitoring wells, direct-push technology, and surface water samples. Groundwater contamination associated with trichloroethylene is primarily exhibited in a narrow plume that extends from the source area at P-Reactor and west to Steel Creek. Maximum contaminant level exceedances in groundwater occur over an area of ∼6.9 hectares for trichloroethylene with concentrations as high as 7.7 milligrams per liter. To the west of the P-Area facility area, the trichloroethylene groundwater plume is controlled by a buried geologic feature, assumed to be an old stream bed, that further narrows the groundwater plume in what has been designated as the 'neck area.' This narrowing of the groundwater plume provides an ideal location for a treatment barrier. The non-time critical removal action alternative chosen is to install a zero-valent iron permeable reactive barrier within the neck area of the trichloroethylene groundwater plume, perpendicular to groundwater flow direction. This technology will provide a treatment barrier that will reduce trichloroethylene groundwater concentrations by 90% and has an anticipated useful life of at least 25 years. A pre-design investigation was performed in the neck area to confirm site lithology, hydrogeology, geochemistry, and extent of trichloroethylene contamination prior to a final design. A treatability study, conducted as part of the pre-design investigation, indicated that the subsurface and groundwater in the PArea Groundwater Operable Unit is compatible with the zero-valent iron and will not lead to excessive buildup from mineralization/precipitation or biofouling. Probabilistic modeling was conducted using field and laboratory data to determine the expected performance of the zero-valent iron permeable reactive barrier. The model simulations indicated that a 3.81-centimeter thick barrier would provide greater than 90% reduction of trichloroethylene groundwater concentration. The final design of the zero-valent iron permeable reactive barrier is a barrier that will extend 80.5 linear meters in a 'zigzag' orientation to best transect the trichloroethylene plume and account for varying groundwater flow. The barrier will be installed from 13.7 meters below ground surface to 41.1 meters below ground surface for 65.8 linear meters and from 13.7 meters below ground surface to 36.6 meters below ground surface for 14.6 linear meters, the base of which is 'keyed' into a low permeability zone. The barrier is designed to a thickness of 10.2 centimeters, which was determined to reduce the trichloroethylene groundwater concentrations by greater than 90% with a safety factor of 2.67. A total of approximately 689 metric tons of zero-valent iron will be injected through 22 injection wells spaced 3.66 meters apart, using guar to suspend the zero-valent iron. Zero-valent iron permeable reactive barrier construction will be monitored through 23 installed resistivity receivers offset 7.32 meters from the zerovalent iron permeable reactive barrier. The zero-valent iron will be energized with a low-voltage 100 Hertz signal during injection and will be monitored using the resistivity receivers to ensure complete coalescence of the zero-valent iron permeable reactive barrier. The zero-valent iron was sized to have a hydraulic conductivity greater than the natural subsurface, thus promoting groundwater flow through the barrier. As contaminated groundwater contacts the zero-valent iron, volatile organic compounds, including trichloroethylene, are immediately degraded to harmless compounds such as ethylene. The performance of the zero-valent iron permeable reactive barrier will be monitored using three upgradient monitoring well clusters, six downgradient monitoring well clusters, and four in-wall monitoring wells. The in-wall monitoring wells will indicate immediate reduction of trichloroethylene mass in the groundwater and allow analyses of the zero-valent iron permeable reactive barrier health. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mechanisms of phosphate removal by Micron-Scale Zero-Valent iron

Extensive studies have been carried out on phosphate removal by zero valent iron (ZVI). Different mechanisms of phosphate removal by ZVI such as phosphate adsorption and precipitation of ferric phosphate and vivianite (Fe 3 (PO 4 ) 2 ·8H 2 O) have been reported. In this study, attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR), X-ray powder diffraction (XRD), and X-ray absorption near edge spectroscopy (XANES) were used to elucidate the mechanisms of phosphate removal by micron-scale zero-valent (mZVI). Time-series ATR-FTIR analysis revealed that phosphate was removed by ZVI in two steps: a) adsorption of phosphate in the first 3 days, and b) slow conversion of the adsorbed phosphate into the precipitated form in 6 days. XRD and XANES analysis determined that iron oxides, ferric ion, and ZVI with oxide layer inhibited the formation of vivianite, resulting in the formation of phosphate precipitates, such as H 2 Fe(II)P 2 O 7 . The results suggested that phosphate is removed by ZVI mainly through precipitation under aerobic conditions. In conclusion, the knowledge gained in this study improves the fundamental understanding of the phosphate removal processes via ZVI.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mechanistic insights into Cr(VI) removal by a combination of zero-valent iron and pyrite

Recent studies have revealed that a combination of zero-valent iron (ZVI) and pyrite (FeS 2 ) can effectively remove (Cr(VI)) from water, but the reasons behind this synergistic effect are still unclear. Our batch experiments showed that dissolved oxygen (DO) is a critical factor in the improved removal of Cr(VI) by ZVI and pyrite. When 0.08 g/L pyrite was combined with 0.5 g/L ZVI in the presence of DO, total Cr was reduced from 10 mg/L to 0.02 mg/L within 6 h. Conversely, in the absence of DO, total Cr was only reduced to 5.6 mg/L. DO oxidation of pyrite produced protons that promote ZVI corrosion, and mixing pyrite with water creates dissolved sulfide, which also contributes to the improved removal of Cr(VI). Here, electron microscopy images and X-ray absorption near edge structure analyses revealed that the presence of dissolved sulfide led to the formation of ferrous sulfide precipitates on the ZVI surface, preventing the formation of a passivating layer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Field demonstration of DNAPL dehalogenation using emulsified zero-valent iron

This paper describes the results of the first field-scale demonstration conducted to evaluate the performance of nanoscale emulsified zero-valent iron (EZVI) injected into the saturated zone to enhance in situ dehalogenation of dense, nonaqueous phase liquids (DNAPLs) containing trichloroethene (TCE). EZVI is an innovative and emerging remediation technology. EZVI is a surfactant-stabilized, biodegradable emulsion that forms emulsion droplets consisting of an oil-liquid membrane surrounding zero-valent iron (ZVI) particles in water. EZVI was injected over a five day period into eight wells in a demonstration test area within a larger DNAPL source area at NASA's Launch Complex 34 (LC34) using a pressure pulse injection method. Soil and groundwater samples were collected before and after treatment and analyzed for volatile organic compounds (VOCs) to evaluate the changes in VOC mass, concentration and mass flux. Significant reductions in TCE soil concentrations (>80%) were observed at four of the six soil sampling locations within 90 days of EZVI injection. Somewhat lower reductions were observed at the other two soil sampling locations where visual observations suggest that most of the EZVI migrated up above the target treatment depth. Significant reductions in TCE groundwater concentrations (57 to 100%) were observed at all depths targeted with EZVI. Groundwater samples from the treatment area also showed significant increases in the concentrations of cis-1,2-dichloroethene (cDCE), vinyl chloride (VC) and ethene. The decrease in concentrations of TCE in soil and groundwater samples following treatment with EZVI is believed to be due to abiotic degradation associated with the ZVI as well as biodegradation enhanced by the presence of the oil and surfactant in the EZVI emulsion.

Water Pollutants/isolation & purification↗

Field Demonstration of DNAPL Dehalogenation Using Emulsified Zero-Valent Iron

This paper describes the results of the first field-scale demonstration conducted to evaluate the performance of nano-scale emulsified zero-valent iron (EZVI) injected into the saturated zone to enhance in situ dehalogenation of dense, non-aqueous phase liquids (DNAPLs) containing trichloroethene (TCE). EZVI is an innovative and emerging remediation technology. EZVI is a surfactant-stabilized, biodegradable emulsion that forms emulsion droplets consisting of an oil-liquid membrane surrounding zero-valent iron (ZVI) particles in water. EZVI was injected over a five day period into eight wells in a demonstration test area within a larger DNAPL source area at NASA's Launch Complex 34 (LC34) using a pressure pulse injection method. Soil and groundwater samples were collected before and after treatment and analyzed for volatile organic compounds (V005) to evaluate the changes in VOC mass, concentration and mass flux. Significant reductions in TCE soil concentrations (>80%) were observed at four of the six soil sampling locations within 90 days of EZVI injection. Somewhat lower reductions were observed at the other two soil sampling locations where visual observations suggest that most of the EZVI migrated up above the target treatment depth. Significant reductions in TCE groundwater concentrations (57 to 100%) were observed at all depths targeted with EZVI. Groundwater samples from the treatment area also showed significant increases in the concentrations of cis-1,2-dichloroethene (cDCE), vinyl chloride (VC) and ethene. The decrease in concentrations of TCE in soil and groundwater samples following treatment with EZVI is believed to be due to abiotic degradation associated with the ZVI as well as biodegradation enhanced by the presence of the oil and surfactant in the EZVI emulsion.

Quinn, Jacqueline↗

Application of Emulsified Zero-Valent Iron to Marine Environments

Contamination of marine waters and sediments with heavy metals and dense non-aqueous phase liquids (DNAPLs) including chlorinated solvents, pesticides and PCBs pose ecological and human health risks through the contaminant's potential bioaccumulation in fish, shellfish and avian populations. The contaminants enter marine environments through improper disposal techniques and storm water run-off. Current remediation technologies for application to marine environments include costly dredging and off-site treatment of the contaminated media. Emulsified zero-valent iron (EZVI) has been proven to effectively degrade dissolved-phase and DNAPL-phase contaminants in freshwater environments on both the laboratory and field-scale level. However, the application to marine environments is only just being explored. This paper discusses the potential use of EZVI in brackish and saltwater environments, with supporting laboratory data detailed. Laboratory studies were performed in 2005 to establish the effectiveness of EZVI to degrade trichloroethylene (TCE) in saltwater. Headspace vials were setup to determine the kinetic rate of TCE degradation using EZVI in seawater. The reaction vials were analyzed by Gas Chromatographic/Flame Ionization Detection (GC/FID) for ethene production after a 48 day period using a GC/FID Purge and Trap system. Analytical results showed that EZVI was very effective at degrading TCE. The reaction by-products (ethene, acetylene and ethane) were produced at 71% of the rate in seawater as in the fresh water controls. Additionally, iron within the EZVI particles was protected from oxidation of the corrosive seawater, allowing EZVI to perform in an environment where zero-valent iron alone could not compete. Laboratory studies were also performed to establish the effectiveness of emulsified zero-valent metal (EZVM) to remove dissolved-phase cadmium and lead found in seawater. EZVM is comprised of a combination of magnesium and iron metal surrounded by the same oil/surfactant membrane used in EZVI. The removal of cadmium and lead from a seawater matrix is a unique challenge. It requires a system that is resistant to the corrosive nature of seawater while removing specific ions that are in a relatively low concentration compared to naturally occurring seawater salts. Laboratory studies conducted show greater than 99% removal of lead and 96% removal of cadmium from a seawater solution spiked at 5 mg/L that was treated with an Emulsified Zero-Valent Metal (EZVM). The cadmium and lead are removed from the solution as they transport across the emulsion membrane and plate out onto the zero-valent metal surface.

Brooks, Kathleen B.↗

Nano zero valent iron electrodeposition at boron doped diamond electrodes

Here, in this study, we present an ecofriendly and simple electrochemical method for synthesizing nano zero-valent iron particles (nZVIs) directly on boron-doped diamond (BDD) electrode surfaces. A BDD electrode served as the substrate for electrodeposition using a 5 mM FeCl 3 /0.1 M KCl solution and chronoamperometry at an applied potential of −1.3 V versus Ag/AgCl (1 M KCl), as determined by cyclic voltammetry (CV) and supported by Pourbaix diagram analysis. The electrochemical behavior and surface modification were characterized using CV, electrochemical impedance spectroscopy (EIS), and surface analysis and microscopy techniques. The results confirm that BDD electrodes can serve as effective platforms for a controlled deposition of 56 nm nZVIs, offering a promising strategy for the development of advanced materials for environmental remediation, catalysis, and sensing applications.

36 MATERIALS SCIENCE↗

Reductive removal of pertechnetate and chromate by zero valent iron under variable ionic strength conditions

Radioactive technetium-99 (Tc) present in waste streams and subsurface plumes at legacy nuclear reprocessing sites worldwide poses potential risks to human health and the environment. This research comparatively evaluated efficiency of zero valent iron (ZVI) toward reductive removal of Tc(VII) in presence of Cr(VI) from NaCl and Na 2 SO 4 electrolyte solutions under aerobic conditions. In both electrolytes, anticorrosive Cr(VI) suppressed oxidation of ZVI at elevated concentrations resulting in the delay of initiation of Tc(VII) reduction to Tc(IV)). In the absence of Cr(VI), no such delay was observed in the analogous systems. At low ionic strength, retarded ZVI oxidation inhibited Tc(VII) reduction in part due to the competing thermodynamically more favorable reduction of Cr(VI) to Cr(III); this effect was particularly pronounced in the chloride medium at the ionic strength ? 0.1. Higher ionic strength favored reduction of both Tc(VII) and Cr(VI), which followed a second-order reaction rate in both electrolytes attributed to the more efficient iron oxidation as evident from x-ray diffraction and electron microscopy measurements. Magnetite was the primary iron oxide phase, and its higher fraction in the SO 4 2- solutions facilitated reductive removal of Tc(VII) and Cr(VI). In the Cl- matrix, Cr(VI) promoted further oxidation of magnetite as well as formation of chromite diminishing overall reductive capacity of this system and resulting in less effective removal of Tc(VII) compared to the SO 4 2- solutions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Zero Valent Iron for Reductive Removal of Technetium-99 from Aqueous Sulfate Solutions - 20347

This research investigates the reductive removal of technetium-99 ({sup 99}Tc) by zero valent iron (ZVI) from low activity waste (LAW) off-gas condensate simulant as a secondary treatment after recovery from vitrification planned at the Hanford Tank Waste Treatment and Immobilization Plant (WTP). Due to its high volatility, only a fraction of Tc{sup (VII)} will be incorporated into glass waste forms. Volatilized Tc will be captured by an off-gas treatment system with current plans to recycle off-gas condensate back to the vitrification facility. The scheme with off-gas recycling will increase Tc loading in the glass waste, but will also increase the concentrations of sulfate, halides, and other problematic constituents impeding overall LAW processing and increasing volume of the glass product. This study focuses on Tc{sup (VII)} removal by ZVI as a feasible pathway to minimize off-gas condensate recycling, which may result in a reduction in the volumes of LAW waste to be immobilized and subsequent cost savings. ZVI is an established treatment agent for redox-active contaminants such as trichloroethylene, nitrate, arsenic, chromium, phenol, and others. It is a commercially available and cost-effective material. Our previous experiments showed that ZVI is very efficient for the reductive removal of {sup 99}Tc. In this work we studied ZVI oxidation under aerobic conditions at pH 7 with 0.1 M Na{sub 2}SO{sub 4} solution (ionic strength, IS, 0.3 M) in the presence and absence of {sup 99}Tc. The concentration of {sup 99}Tc and the changes in pH, dissolved oxygen (DO), and oxidation-reduction potential (ORP) of the simulated solutions were monitored over 8 days. The formation of iron oxide phases was probed by X-ray diffraction (XRD). Obtained results suggest that ZVI contact time with {sup 99}Tc containing solutions for 6 hours resulted in nearly complete removal of {sup 99}Tc from the aqueous phase. XRD analysis showed that the oxidation of ZVI is rapid with formation of magnetite (Fe{sub 3}O{sub 4}) with minor percentage of goethite and maghemite. This work is a part of a larger set of studies investigating the feasibility of {sup 99}Tc reductive removal from the LAW off-gas condensate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application of Emulsified Zero-Valent Iron to Marine Environments

Contamination of marine waters and sediments with heavy metals and dense non-aqueous phase liquids (DNAPLs) including chlorinated solvents, pesticides and PCBs pose ecological and human health risks through the potential of the contaminant to bioaccumulate in fish, shellfish and avian populations. The contaminants enter marine environments through improper disposal techniques and storm water runoff. Current remediation technologies for application to marine environments include costly dredging and off-site treatment of the contaminated media. Emulsified zero-valent iron (EZVI) has been proven to effectively degrade dissolved-phase and DNAPL-phase contaminants in freshwater environments on both the laboratory and field-scale level. Emulsified Zero-Valent Metal (EZVM) using metals such as iron and/or magnesium have been shown in the laboratory and on the bench scale to be effective at removing metals contamination in freshwater environments. The application to marine environments, however, is only just being explored. This paper discusses. the potential use of EZVI or EZVM in brackish and saltwater environments, with supporting laboratory data detailing its effectiveness on trichloroethylene, lead, copper, nickel and cadmium.

Quinn, Jacqueline W.↗

Time dependent zero valent iron oxidation and the reductive removal of pertechnetate at variable pH

Elemental iron Fe 0 is a promising reductant for removal of radioactive technetium-99 (Tc) from complex aqueous waste streams that contain sulfate, halides, and other inorganic anions generated during processing of legacy radioactive waste. The impact of sulfate on the kinetics of oxidation and reduction capacity of Fe 0 in the presence of Tc has not been examined. We investigated the oxidative transformation of Fe 0 and reductive removal of TcO 4 - in 0.1 M Na 2 SO 4 as a function of initial pH (i.e., pH i 4, 7, and 10) under aerobic conditions up to 30 days. Tc reduction was the fastest at pH i 7 and slowest at pHi 10 (Tc reduction rate pHi 7 > 4 > 10). Aqueous fraction of Tc was measured at 0.4% at pH i 7 within 6 h, whereas ≥ 97% of Tc was removed from solutions at pH i of 4 and 10 within 24 h. Solid phase characterization showed that magnetite was the only oxidized crystalline phase for the first 6 h regardless of initial pH. Lepidocrocite was the most abundant oxidized product for pH i 10 after 5 days, but was not observed at pH of 4 or 7.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Soil Mixing with Steam and Zero Valent Iron Remediation Performance Monitoring Results at Wilson Corner, Kennedy Space Center, Florida

The National Aeronautics and Space Administration (NASA), Kennedy Space Center (KSC), Remediation Program implemented a groundwater interim measure between September 2014 and February 2015, to remediate a trichloroethene (TCE) groundwater source area at the Wilson Corners site. The groundwater plume is associated with the release of chlorinated solvents (specifically TCE) from historic precision cleaning and laboratory operations. A summary of the groundwater interim measure using soil mixing with steam and zero valent iron (also referred to as large diameter auger [LDA]) was presented at the 2015 Florida Remediation Conference. The objective of this presentation is to provide performance monitoring results.

Chrest, Anne M.↗

Formation of ferrihydrite and associated iron corrosion products in permeable reactive barriers of zero-valent iron

Ferrihydrite, which is known to form in the presence of oxygen and to be stabilized by the adsorption of Si, PO4 and SO4, is ubiquitous in the fine-grained fractions of permeable reactive barrier (PRB) samples from the U.S. Coast Guard Support Center (Elizabeth City, NC) and the Denver Federal Center (Lakewood, CO) studied by high-resolution transmission electron microscopy and selected area electron diffraction. The concurrent energy-dispersive X-ray data indicate a strong association between ferrihydrite and metals such as Si, Ca, and Cr. Magnetite, green rust 1, aragonite, calcite, mackinawite, greigite and lepidocrocite were also present, indicative of a geochemical environment that is temporally and spatially heterogeneous. Whereas magnetite, which is known to form due to anaerobic Fe0 corrosion, passivates the Fe0 surface, ferrihydrite precipitation occurs away from the immediate Fe0 surface, forming small (<0.1 microm) discrete clusters. Consequently, Fe0-PRBs may remain effective for a longer period of time in slightly oxidized groundwater systems where ferrihydrite formation occurs compared to oxygen-depleted systems where magnetite passivation occurs. The ubiquitous presence of ferrihydrite suggests that the use of Fe0-PRBs may be extended to applications that require contaminant adsorption rather than, or in addition to, redox-promoted contaminant degradation.

Metals/chemistry↗

Investigation into Reductive Separation of Tc-99 from Low Activity Waste Off-Gas Condensate by Zero Valent Iron Materials - 20311

This study is investigating the potential for reductive separation of technetium-99 (Tc) from off-gas condensate generated from vitrification of legacy tank waste at the Hanford Tank Waste Treatment and Immobilization Plant. Management of Tc is a high-priority activity for the U.S. Department of Energy (DOE) Office of Environmental Management (EM) complex, which must be addressed based on knowledge gaps and technology development needs outlined in the DOE-EM Technetium Management Program Plan [1]. Technetium is one of the main risk drivers in the permanent disposal of low activity waste (LAW) by vitrification at the Hanford Site due to its high volatility and only fractional incorporation into borosilicate glass. Volatilized Tc will be captured by an off-gas treatment system, and the current plan is to continuously recycle generated condensate back to the LAW glass melter feed. Off-gas recycling is effective at increasing Tc loading in the LAW glass, but it also disproportionately increases concentrations of sulfate, halides, and other volatile compounds impeding overall LAW processing leading to significantly greater waste glass volume requirements. Removal of Tc from secondary liquid waste offers an alternative disposal route to continuous off-gas recycling which may result in significant reduction of the volumes of LAW waste glass and substantial cost savings. The objective of this research funded by the DOE-EM Minority Serving Institutions Partnership Program (MSIPP) is to determine the suitability of zero valent iron (ZVI) as a separation technology to remove Tc from the off-gas condensate stream to minimize its recycle. While ZVI has been proposed for various remediation applications with Tc, it has not been studied for its suitability for removing Tc from the LAW off-gas condensate. The goal is to identify the optimal conditions for which Tc{sup (VII)} will be reduced to Tc{sup (IV)} species and incorporated into an iron matrix. This paper presents a programmatic overview of our evaluation of commercial ZVI materials for their efficiency towards Tc{sup (VII)} reductive removal from simplified off-gas simulant solutions under aerobic conditions. Tc concentrations in solutions were monitored for up to 30 days to determine efficiency and kinetics of reductive removal of Tc. The best performing candidate materials were selected for further experiments evaluating the effects of (1) variable ionic strength, (2) the presence of chromium and corrosive anions, and (3) ZVI aging on Tc{sup (VII)} reductive removal in batch experiments. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗