Search NASA⌕ Search

SEARCH · Search NASA

Results for “aberration-corrected TEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Phase evolution and structural modulation during in situ lithiation of MoS 2 , WS 2 and graphite in TEM

Li-ion batteries function by Li intercalating into and through the layered electrode materials. Intercalation is a solid-state interaction resulting in the formation of new phases. The new observations presented here reveal that at the nanoscale the intercalation mechanism is fundamentally different from the existing models and is actually driven by nonuniform phase distributions rather than the localized Li concentration: the lithiation process is a ‘distribution-dependent’ phenomena. Direct structure imaging of 2H and 1T dual-phase microstructures in lithiated MoS 2 and WS 2 along with the localized chemical segregation has been demonstrated in the current study. Li, a perennial challenge for the TEM, is detected and imaged using a low-dose, direct-electron detection camera on an aberration-corrected TEM and confirmed by image simulation. This study shows the presence of fully lithiated nanoscale domains of 2D host matrix in the vicinity of Li-lean regions. This confirms the nanoscale phase formation followed by Oswald ripening, where the less-stable smaller domains dissolves at the expense of the larger and more stable phases.

25 ENERGY STORAGE↗

4D-STEM of Beam-Sensitive Materials

We report that a scanning electron nanobeam diffraction, or 4D-STEM (four-dimensional scanning transmission electron microscopy), is a flexible and powerful approach to elucidate structure from "soft" materials that are challenging to image in the transmission electron microscope because their structure is easily damaged by the electron beam. In a 4D-STEM experiment, a converged electron beam is scanned across the sample, and a pixelated camera records a diffraction pattern at each scan position. This four-dimensional data set can be mined for various analyses, producing maps of local crystal orientation, structural distortions, crystallinity, or different structural classes. Holding the sample at cryogenic temperatures minimizes diffusion of radicals and the resulting damage and disorder caused by the electron beam. The total fluence of incident electrons can easily be controlled during 4D-STEM experiments by careful use of the beam blanker, steering of the localized electron dose, and by minimizing the fluence in the convergent beam thus minimizing beam damage. This technique can be applied to both organic and inorganic materials that are known to be beam-sensitive; they can be highly crystalline, semicrystalline, mixed phase, or amorphous. One common example is the case for many organic materials that have a π-π stacking of polymer chains or rings on the order of 3.4-4.2 Å separation. If these chains or rings are aligned in some regions, they will produce distinct diffraction spots (as would other crystalline spacings in this range), though they may be weak or diffuse for disordered or weakly scattering materials. We can reconstruct the orientation of the π-π stacking, the degree of π-π stacking in the sample, and the domain size of the aligned regions. This Account summarizes illumination conditions and experimental parameters for 4D-STEM experiments with the goal of producing images of structural features for materials that are beam-sensitive. We will discuss experimental parameters including sample cooling, probe size and shape, fluence, and cameras. 4D-STEM has been applied to a variety of materials, not only as an advanced technique for model systems, but as a technique for the beginning microscopist to answer materials science questions. It is noteworthy that the experimental data acquisition does not require an aberration-corrected TEM but can be produced on a variety of instruments with the right attention to experimental parameters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct Mapping of Fluorine in Cation Disordered Rocksalt Cathodes

Cation-disordered rocksalt (DRX) oxides are promising candidates as next-generation cathodes for lithium-ion batteries. Partial fluorination of the DRX oxides enhances their cyclability. However, the lattice position, concentration, and spatial distribution of fluorine within DRX lattices remain elusive. Here, in this work, we use atom location by channeling-enhanced microanalysis, energy-dispersive X-ray spectroscopy, electron energy loss spectroscopy, and integrated differential phase contrast imaging in a scanning transmission electron microscope to gain atomic-level insights into DRX with nominal composition of Li 1.2 Mn 0.7 Ti 0.1 O 1.7 F 0.3 and Li 1.15 Ni 0.45 Ti 0.3 Mo 0.1 O 1.85 F 0.15 . We reveal that fluorine substitutes oxygen in the DRX lattices. The O/F ratio in terms of O+F = 2 is in the range from 1.92:0.08 to 1.82:0.18. Spatially, fluorine is distributed in the proximity of the Li-rich regions but distinct from lithium fluoride. Additionally, we observe that incorporation of fluorine in the DRX lattice induces a larger variation in cation–anion separation. These observations provide insight into the guided design of oxyfluoride DRX cathodes for high-performance batteries.

(S)TEM↗

In situ TEM study of crystallization and chemical changes in an oxidized uncapped Ge 2 Sb 2 Te 5 film

Ge 2 Sb 2 Te 5 (GST-225) has been the most used active material in nonvolatile phase-change memory devices. Understanding the kinetics and dynamics involved in crystallization is critical for the optimization of materials and devices. A GST-225 thin film of 20 nm thickness was prepared by sputtering directly onto a Protochip and left uncapped and exposed to atmosphere for approximately 1 year. Here, early stages of crystallization and growth of the film have been studied inside the TEM from room temperature to 140 °C. The morphological and structural transformations have been studied by a C s -corrected environmental TEM, and images have been recorded using a high-speed low electron dose camera (Gatan K3 IS). The amorphous to crystalline transformation has been observed at ~35 °C. From the large field, high-resolution images obtained using the Gatan K3 IS camera early crystallization can be detected and nucleation rates and growth velocities can be obtained.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanocompression of 20 nm Silver Nanoparticles: In situ Aberration‐Corrected TEM and Atomistic Simulations

Single‐crystalline nanoparticles play an increasingly important role in a wide variety of fields including pharmaceuticals, advanced materials, catalysts for fuel cells, energy materials, as well as environmental detection and monitoring. Yet, the deformation mechanisms of very small nanoparticles are still poorly understood, in particular the role played by single dislocations and their interaction with surfaces. Here, in this work, silver nanoparticles with particularly small dimensions (≈20 nanometers in diameter) are compressed in situ in an aberration‐corrected transmission electron microscopy (TEM) and molecular dynamics (MD) simulations. During compression, the emergence of both dislocations and nanotwins are observed. However, these defects prove to be unstable and disappear upon removal of the indenter. Atomistic simulations confirm the role played by image stresses associated with the nearby surfaces and the reduction in dislocation line length as it approaches the free surface, thereby supporting the experimental observations. These results provide justification for the frequent observation of the absence of dislocations in nanoparticles of a few nanometers in size during in situ experiments, even after significant deformation. This phenomenon contributes to the self‐healing of samples through dislocation ejection toward the surfaces.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Possibility of an integrated transmission electron microscope: enabling complex in-situ experiments

Abstract Multimodal in-situ experiments are the wave of the future, as this approach will permit multispectral data collection and analysis during real-time nanoscale observation. In contrast, the evolution of technique development in the electron microscopy field has generally trended toward specialization and subsequent bifurcation into more and more niche instruments, creating a challenge for reintegration and backward compatibility for in-situ experiments on state-of-the-art microscopes. We do not believe this to be a requirement in the field; therefore, we propose an adaptive instrument that is designed to allow nearly simultaneous collection of data from aberration-corrected transmission electron microscopy (TEM), probe-corrected scanning transmission electron microscopy, ultrafast TEM, and dynamic TEM with a flexible in-situ testing chamber, where the entire instrument can be modified as future technologies are developed. The value would be to obtain a holistic understanding of the underlying physics and chemistry of the process-structure–property relationships in materials exposed to controlled extreme environments. Such a tool would permit the ability to explore, in-situ, the active reaction mechanisms in a controlled manner emulating those of real-world applications with nanometer and nanosecond resolution. If such a powerful tool is developed, it has the potential to revolutionize our materials understanding of nanoscale mechanisms and transients. Graphical Abstract

36 MATERIALS SCIENCE↗

The performance evaluation of direct detection electron energy-loss spectroscopy at 200 kV and 80 kV accelerating voltages

Direct electron detectors (DeDs) have been widely used for imaging studies because of their higher beam sensitivity, lower noise, improved pixel resolution, etc. However, there have been limited studies related to the performance in spectroscopic applications for the direct electron detection. Hereby, taking the advantage of the DeD installed on a high-performance electron energy-loss spectrometer, we systematically studied the performance of a DeD (Gatan's K2 IS) fitted on an aberration-corrected transmission electron microscope (TEM) equipped with an electron monochromator. Using SrTiO3 as the model system, the point spread function in the zero-loss region of the spectrum and the performance for core loss spectroscopy have been investigated under both 200 kV and 80 kV operating conditions. We demonstrate that the K2 detector can achieve an overall better performance at 200 kV than a charge coupled device (CCD) detector. At 80 kV, the K2 DeD is still better than a CCD, except for the relative broad tails of the zero-loss peak. The signal-to-noise ratio is very close for DeD and CCD under 80 kV. Based on our data obtained at different operating voltages, it is clear that DeD will benefit the microscopy community and boost the development of cutting-edge materials science studies by pushing the frontiers in electron energy-loss spectroscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Probing Electronic and Structural Transformations during Thermal Reduction of the Promising Water Splitting Perovskite BaCe 0.25 Mn 0.75 O 3

Here, in this report, we investigate the thermal reduction of the octahedral perovskite BaCe 0.25 Mn 0.75 O 3 (BCM) using in situ electron energy loss spectroscopy (EELS) in an aberration-corrected transmission electron microscope (TEM). The 12R-polytype of BCM is known to demonstrate high solar thermochemical hydrogen production capacity. In situ EELS measurements show that Mn is the active redox cation in BCM, undergoing thermal reduction from Mn 4+ to Mn 3+ during heating to 700 °C inside the TEM under a high vacuum. The progressive reduction of Mn 4+ during oxygen vacancy (O v ) formation was monitored as a function of temperature. Additionally, atomic-resolution scanning transmission electron microscopy identified two different types of twin boundaries present in the oxidized and reduced form of 12R-BCM, respectively. These two types of twin boundaries were shown, via computational modeling, to modulate the site-specific O v formation energies in 12R-BCM. It is concluded that these types of atomic defects provide sites more energetically favorable for O v formation during thermal reduction.

36 MATERIALS SCIENCE↗

Double-Bilayer polar nanoregions and Mn antisites in (Ca, Sr)3Mn2O7

Abstract The layered perovskite Ca 3 Mn 2 O 7 (CMO) is a hybrid improper ferroelectric candidate proposed for room temperature multiferroicity, which also displays negative thermal expansion behavior due to a competition between coexisting polar and nonpolar phases. However, little is known about the atomic-scale structure of the polar/nonpolar phase coexistence or the underlying physics of its formation and transition. In this work, we report the direct observation of double bilayer polar nanoregions (db-PNRs) in Ca 2.9 Sr 0.1 Mn 2 O 7 using aberration-corrected scanning transmission electron microscopy (S/TEM). In-situ TEM heating experiments show that the db-PNRs can exist up to 650 °C. Electron energy loss spectroscopy (EELS) studies coupled with first-principles calculations demonstrate that the stabilization mechanism of the db-PNRs is directly related to an Mn oxidation state change (from 4+ to 2+), which is linked to the presence of Mn antisite defects. These findings open the door to manipulating phase coexistence and achieving exotic properties in hybrid improper ferroelectric.

36 MATERIALS SCIENCE↗

Site-specific plan-view (S)TEM sample preparation from thin films using a dual-beam FIB-SEM

To fully evaluate the atomic structure, and associated properties of materials using transmission electron microscopy, examination of samples from three non-collinear orientations is needed. This is particularly challenging for thin films and nanoscale devices built on substrates due to limitations with plan-view sample preparation. In this work, a new method for preparation of high-quality, site-specific, plan-view TEM samples from thin-films grown on substrates, is presented and discussed. Here, it is based on using a dual-beam focused ion beam scanning electron microscope (FIB-SEM) system. To demonstrate the method, the samples were prepared from thin films of perovskite oxide BaSnO 3 grown on a SrTiO 3 substrate and metal oxide IrO 2 on a TiO 2 substrate, ranging from 20–80 nm in thicknesses using molecular beam epitaxy. While the method is optimized for the thin films, it can be extended to other site-specific plan-view samples and devices build on wafers. Aberration-corrected STEM was used to evaluate the quality of the samples and their applicability for atomic-resolution imaging and analysis.

BaSnO3↗

Structure of the (110) Ln ScO 3 ( Ln =Gd,Tb,Dy) surfaces

The surface reconstruction on the (110) surface of LnScO 3 (Ln=Gd,Tb,Dy) has been investigated using x-ray photoelectron spectroscopy, atomic force microscopy, and transmission electron diffraction coupled with higher-level density-functional theory methods. The experimental techniques generate constraints on the surface chemistry and structure that are used to inform the theoretical comparison of a number of potential surface structures. The resulting structure is then compared to experimental aberration-corrected transmission electron microscopy results using multislice simulation. The surfaces of both single-crystalline substrates and hydrosauna synthesized nanoparticles exhibit a Sc-rich double layer with a Sc 3 O 4 termination.

36 MATERIALS SCIENCE↗

Ultracold cryogenic TEM with liquid helium and high stability

Cryogenic transmission electron microscopy has revolutionized structural biology and materials science. To image below liquid nitrogen temperatures, various liquid helium stages have been constructed but have proven to be complex and unstable, making high-resolution imaging challenging. This problem is even more pronounced in side-entry specimen holders common on modern transmission electron microscopes. Here, we introduce an ultracold liquid helium transmission electron microscope side-entry specimen holder, featuring continuous cryogen flow and vibration decoupling. This instrument is compatible with modern aberration-corrected microscopes and achieves sub-25 K base temperature, ±2 mK thermal stability over many hours, and atomic resolution—setting the stage for a new era of cryogenic electron microscopy.

42 ENGINEERING↗

The ABCs of phase retrieval: Connecting the acronyms of scanning transmission electron microscopy

High-resolution scanning transmission electron microscopy (S/TEM) is an indispensable tool for characterizing the structure and properties of materials down to the atomic scale. Conventional S/TEM imaging, however, is limited by the phase problem, whereby the phase of the electron exit wave is lost upon detection. Recent advances in diffractive imaging and 4D-STEM have enabled a range of phase-retrieval techniques that computationally reconstruct the missing information encoded in the phase of the transmission function. These approaches offer improved dose efficiency and enhanced sensitivity to weakly scattering signals, extending quantitative imaging to beam-sensitive materials composed of light elements. In this work, we introduce the phase problem in electron microscopy and survey the diverse landscape of phase-retrieval techniques used in the field. Despite their many acronyms and algorithmic variations, these techniques share a common physical and mathematical foundation. We present a unified framework that connects these seemingly distinct methods, from parallax imaging and tilt-corrected bright-field (tcBF-STEM), to aberration-corrected bright-field (acBF-STEM), optimum bright-field (OBF-STEM) and single-sideband (SSB) ptychography, as well as first-moment integrated center of mass techniques (iCOM) and iterative ptychographic algorithms. Based on these insights, we discuss the opportunities and practical limitations of applying these methods across different materials systems, detector designs, and microscope configurations.Graphical abstractRepresentative electron microscopy configurations used for phase retrieval and diffractive imaging in S/TEM: (a) Zernike phase-contrast transmission electron microscopy (TEM), (b) small-convergence-angle four-dimensional scanning transmission electron microscopy (4D-STEM) for nanobeam-based phase reconstruction methods, and (c) large-convergence-angle 4D-STEM for ptychographic and related diffractive imaging techniques reviewed in this work.

36 MATERIALS SCIENCE↗

Molecular-Resolution Electron Imaging of Defects and Dynamics at the Ice-Water Interface

Water crystallization into hexagonal ice (type I h ) is one of the most critical processes relevant to the Earth’s environment and human activities. However, despite recent breakthroughs in imaging non-equilibrium condensed ice structures, the ice-water interface has never been imaged at a molecular resolution. This is primarily due to the low stability of the hydrogen bonds in ice under high-resolution microscopy conditions and a lack of methods to prepare compatible samples. Here, this presentation describes the first molecular-resolution imaging of ice crystallized from liquid water and the ice-water interface using high-resolution transmission electron microscopy (HRTEM). By encapsulating deionized (DI) water between two amorphous carbon (a-C) TEM grids and subsequently freezing it with liquid N 2 on a cryo sample stage, we generated two types of ice: non-equilibrium, condensed ice from the atmosphere and encapsulated ice from the DI water (Fig. 1A). Condensed ice usually shows irregular, spherulitic shapes (Fig. 1B). Selected area electron diffraction (SAED) shows that they are a mixture of cubic and hexagonal crystals (Fig. 1C). On the contrary, encapsulated ice forms thin films that contain large-area single-crystalline regions of hexagonal ice oriented along the [0001] zone axis (Fig. 1D). Differential electron energy-loss spectroscopy (EELS) confirmed the high purity of the encapsulated ice free from organic contaminations that are common in other encapsulation methods for HRTEM such as graphene liquid cells. These single-crystalline areas are robust under the electron beam up to ~100 e/Å 2 s. Aberration-corrected HRTEM imaging in these areas achieved a line resolution of ~1.3 Å (Fig. 1E and F). This platform allows us to study near-equilibrium ice structures and dynamics at an unprecedented spatial resolution (Fig. 2). For example, we discovered subdomain-rich regions near the defective crystal edges despite the structure appearing single-crystalline according to diffraction criteria. These subdomains connect via low-angle grain boundaries with flat energy landscapes as a function of tilt angles (according to simulations), showing the high tolerance of ice to defect structures. When we tuned the sample temperature and electron flux rate, we observed radiolysis-controlled bubble generation and dissolution in ice single crystals near a steady state of bubble dynamics. Furthermore, rich beam-induced melting and recrystallization dynamics were observed at the ice-water interface with lattice resolution. These data represent the first observation of the ice-water phase transformation at the sub-nanometer level. In summary, the methods developed in this work enabled molecular-resolution observations of ice and the ice-water interface and shed light on the microstructures and phase transformation pathways. Finer control on the temperature, electron irradiation profile, and imaging detector could eventually lead to real-time observation of ice nucleation in water and address long-standing questions in the nucleation pathways.

74 ATOMIC AND MOLECULAR PHYSICS↗

Antiphase-Boundary-Engineered Domain Switching in a (110)-Oriented BiFeO 3 Film

A ferroelectric domain wall memory device exploits the presence (or absence) of domain walls as the basis for information storage. Although structural defects strongly influence ferroelectric domain wall nucleation and growth, this correlation is far from being fully understood. For example, a single defect can play opposing roles: it can act as a nucleation site to initiate domain switching or, conversely, serve as a pinning center inhibiting domain wall motion. This is particularly the case for antiphase boundaries (APBs), whose influence on switching remains relatively unexplored despite being ubiquitous in oxide perovskite ferroelectrics. Here, we use aberration-corrected scanning transmission microscopy and in situ transmission electron microscopy under an applied bias to extensively characterize the influence of an APB on the switching behavior in a (110)-oriented BiFeO 3 thin film. We demonstrate that deterministic nucleation occurs in the proximity of a vertically oriented APB, following which domain growth occurs laterally in a symmetric fashion. Atomic-scale structural analysis reveals that the shear operation vector for the APB is 1/2[110]; this half-unit-cell shift extends over a few nanometers, implying that the APB plane is inclined toward the imaging direction. The symmetric switching observation is attributed to local inhomogeneous lattice strain and a reduction of polarization caused by the APB. These results demonstrate that an extended structural defect can be used as an active switching element rather than a stumbling block in reprogrammable domain-wall-based devices. Ultimately, this will expand the capabilities of ferroelectric thin films for future electronic devices based on ferroelectric domain walls.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electrochemical Evolution of Fuel Cell Platinum Nanocatalysts on Carbon Nanotubes at the Atomic Scale

The evolution of Pt nanoparticles supported on carbon nanotubes is analyzed before and after electrochemical potential cycling, using identical location aberration-corrected transmission electron microscopy, for applications in proton exchange membrane fuel cells. The work is focused on the half-cell accelerated stress test protocol of potential cycles ranging between 1.0 and 1.5 V RHE to represent the start-up/shutdown settings of a fuel cell vehicle. The research work reveals that particle migration and coalescence are key mechanisms for a reduction in the Pt nanoparticle surface area at the early stages of potential cycling. Further, the mechanism for particle movement and coalescence is attributed to carbon corrosion, catalyzed either by Pt or by bulk corrosion of the carbon nanotubes. Carbon corrosion results in the appearance of carbon vacancies at the carbon nanotube/Pt nanoparticle interface during cycling, as well as the formation of edge and surface defects. During cycling, the concentration of the dissoluble Pt increases. As soon as a significant amount is reached, subnanometer/atomic clusters emerge on the carbon nanotube support, which can move and coalesce, or redeposit on the surface of larger particles through Ostwald ripening.

25 ENERGY STORAGE↗