Search NASA⌕ Search

SEARCH · Search NASA

Results for “absorption spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evidence of excited-state lifetime enhancement in dimyristoyl-phosphocholine nanodiscs by ultraviolet absorption spectroscopy

Ultraviolet absorption spectroscopy is an analytical tool that is commonly utilized to determine protein concentrations, primarily due to characteristic absorption of tryptophan and tyrosine at 280 nm. Accurate concentration determination is essential to the accuracy of many biophysical techniques, and ultraviolet absorption provides a convenient and rapid method to assess protein concentration. However, the widespread usage of this method assumes that ultraviolet absorption is the same for individual amino acids in aqueous solution (where the molar extinction coefficient was measured) as for the amino acid in the conformational environment of the protein of interest. We demonstrate that additional considerations may be necessary for the membrane scaffold protein in dimyristoyl-phosphocholine nanodiscs through ultraviolet absorption spectroscopy of nanodiscs, liposomes, the membrane scaffold protein, and a mixture of liposomes and the non-nanodisc-associated protein. The aromatic amino acids of the membrane scaffold protein absorb significantly less light at 280 nm when associated with lipids in a lipoprotein assembly, which we plausibly attribute to an enhancement of chromophore excited-state lifetimes due to reduced intramolecular motion in the nanodisc. We caution that using the molar absorptivity of the membrane scaffold protein alone to determine nanodisc concentrations may not yield accurate results. Instead, the molar absorptivity of each nanodisc formulation should be explored independently to account for the unique conformational environment of each nanodisc.

59 BASIC BIOLOGICAL SCIENCES↗

Exploring the impact of ions on oxygen K-edge X-ray absorption spectroscopy in NaCl solution using the GW-Bethe-Salpeter-equation approach

X-ray absorption spectroscopy (XAS) is a powerful experimental tool to probe the local structure in materials with the core hole excitations. Here, the oxygen K-edge XAS spectra of the NaCl solution and pure water are computed by using a recently developed GW-Bethe-Salpeter equation approach, based on configurations modeled by path-integral molecular dynamics with the deep-learning technique. The neural network is trained on ab initio data obtained with strongly constrained and appropriately normed density functional theory. The observed changes in the XAS features of the NaCl solution, compared to those of pure water, are in good agreement between experimental and theoretical results. We provided detailed explanations for these spectral changes that occur when NaCl is solvated in pure water. Specifically, the presence of solvating ion pairs leads to localization of electron-hole excitons. As a result, our theoretical XAS results support the theory that the effects of the solvating ions on the H-bond network are mainly confined within the first hydration shell of ions, however beyond the shell the arrangement of water molecules remains to be comparable to that observed in pure water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A guide to transient absorption spectroscopy for porous crystalline materials in photocatalysis

Transient absorption spectroscopy has become an increasingly accessible method for probing the fundamental mechanisms of photocatalytic reaction and has provided important mechanistic insights across a wide range of systems. However, recent studies on metal-organic framework and covalent-organic framework based photocatalysts employ transient absorption primarily as a supplementary characterization technique rather than as a tool for gaining mechanistic insight. This perspective identifies recurring limitations in current practices and outlines strategies for more deliberate application of transient absorption spectroscopy in photocatalysis. By emphasizing clarity in data presentation and interpretation, we aim to elevate transient absorption spectroscopy from a routine characterization tool to a powerful approach for elucidating mechanistic photophysics of framework materials that govern their photocatalytic performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-resolution spectroscopy of uranium laser-produced plasma using saturated absorption spectroscopy

High-resolution spectroscopy of laser ablation plumes or laser-produced plasmas (LPPs) is valuable for various applications, including measuring crowded spectral features, determining spectroscopic constants, characterizing plasmas, and performing isotopic analysis. However, various line broadening mechanisms in plasmas limit its use for several applications. Here, in this study, we present the use of saturated absorption spectroscopy (SAS) for Doppler-free linewidth analysis in a uranium LPP. We demonstrate that SAS is effective in obtaining Doppler-free Lamb dip profiles with linewidths on the order of ≤ 20 MHz. The effects of saturation on the Doppler-broadened absorption and Lamb dip profiles at different pressures and probe intensities are quantified, and their impact on measurements of plasma properties is discussed. Finally, we show that the linewidths of the Lamb dips can be used for quantitative estimates of pressure and natural broadening in the plasma.

Absorption spectroscopy↗

Comparison of excitation and kinetic temperatures in a laser-produced plasma using absorption spectroscopy

High-resolution tunable laser absorption spectroscopy is used to measure time-resolved absorption spectra for six neutral uranium transitions in a laser-produced plasma. Here analysis of the spectra shows that kinetic temperatures are similar for all six transitions, but excitation temperatures are higher than kinetic temperatures from 10–100 μs, indicating departures from local thermodynamic equilibrium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Polarization-resolved core exciton dynamics in LiF using attosecond transient absorption spectroscopy

The ability to control absorption by modifying the polarization of light presents an exciting opportunity to experimentally determine the orbital alignment of absorption features. Here, attosecond extreme ultraviolet (XUV) transient absorption spectroscopy is used to investigate the polarization dependence of core exciton dynamics in LiF thin films at the Li + K edge. XUV pulses excite electrons from the Li 1s core level into the conduction band, allowing for the formation of a p-orbital-like core exciton, aligned along the XUV light polarization axis. A sub-5 fs near-infrared (NIR) probe pulse then arrives at variable time delays, perturbing the XUV-excited states and allowing the coherence decay of the core exciton to be mapped. The coherence lifetimes are found to be ≈ 2.4 ± 0.4 fs, which is attributed to a phonon-mediated dephasing mechanism as in previous core exciton studies. The differential absorption features are also shown to be sensitive to the relative polarization of the XUV and NIR fields. The parallel NIR probe induces couplings between the initial XUV-excited p-like bright exciton and s-like dark excitons. When crossed pump and probe polarizations are used, the coupling between the bright and dark states is no longer dipole-allowed, and the transient absorption signal associated with the coupling is suppressed by approximately 90%. This interpretation is supported by simulations of a few-level model system, as well as analysis of the calculated band structure. Here, the results indicate that laser polarization can serve as a powerful experimental tool for exploring the orbital alignment of core excitonic states in solid-state materials.

Attosecond laser spectroscopy↗

In situ monitoring of lanthanide reactions with oxide species via combined absorption spectroscopy and electrochemical methods

Molten salts for engineering scale applications of spent nuclear fuel pyrochemical processing will inevitably have some level of oxygen impurities which can form various insoluble oxide and oxychloride species with uranium and fission products. This work demonstrates real-time concentration monitoring of two trivalent lanthanide (Ln3+) fission products, Nd3+ and Pr3+, and their reactions with oxygen (O2-) impurities to form insoluble products in LiCl-NaCl-KCl eutectic salt. A combination of high-temperature absorption spectroscopy and electrochemical testing were used to track lanthanide concentrations. O2- impurity levels were controlled in the range of 0.001 M to 0.5 M by adding Li2O to lanthanide-salt solutions. After the introduction of O2- impurities, Ln3+ concentrations were monitored via time-resolved absorption spectroscopy. Concentrations of both Ln3+ species in solution decreased with time as insoluble products formed. The initial impurity concentration controlled whether insoluble products were predominantly oxychlorides (LnOCl) or mixtures of oxychlorides and oxides (Ln2O3). However, absorption spectroscopy is limited for weakly absorbing species, such as Pr3+, and under conditions of high impurity concentrations where solutions can be turbid. To circumvent this limitation, the concentrations of Pr3+ were monitored with square wave voltammetry (SWV). Estimated reaction rates and extent of Pr3+ removal from solution as monitored by SWV agreed to within ~10% of the results found from absorption spectroscopy monitoring. This demonstrates that simultaneous electrochemical testing complements and expands the capabilities of absorption spectroscopy to monitor reactions of fission products in molten salts.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In situ Monitoring of Lanthanide Reactions with Oxide Species via Combined Absorption Spectroscopy and Electrochemical Methods

Molten salts for engineering scale applications of spent nuclear fuel pyrochemical processing will inevitably have some level of oxygen impurities which can form insoluble oxide and oxychloride species with fission products. This work demonstrates real-time concentration monitoring of two lanthanide (Ln3+) fission products, Nd3+ and Pr3+, and their reactions with oxygen (O2-) impurities to form insoluble products in LiCl-NaCl-KCl eutectic salt. Combined absorption spectroscopy and electrochemical testing were used to track lanthanide concentrations. O2- impurity levels were controlled by adding Li2O to lanthanide-salt solutions. After the introduction of O2- impurities, Ln3+ concentrations were monitored via time-resolved absorption spectroscopy. Concentrations of both Ln3+ species in solution decreased with time as insoluble products formed. The initial impurity concentration controlled whether insoluble products were predominantly oxychlorides or mixtures of oxychlorides and oxides. However, absorption spectroscopy is limited for weakly absorbing species, such as Pr3+, and under conditions of high impurity concentrations where solutions can be turbid. To circumvent this limitation, the concentrations of Pr3+ were monitored with square wave voltammetry (SWV). Reaction rates and extent of Pr3+ removal from solution as monitored by SWV agreed closely with results found from spectroscopic monitoring. This demonstrates that simultaneous electrochemical testing complements the capabilities of absorption spectroscopy to monitor reactions of fission products in molten salts.

absorption spectroscopy↗

In situ monitoring of lanthanide reactions with oxide species via combined absorption spectroscopy and electrochemical methods

Molten salts for engineering scale applications of spent nuclear fuel pyrochemical processing will inevitably have some level of oxygen impurities which can form insoluble oxide and oxychloride species with fission products. This work demonstrates real-time concentration monitoring of two lanthanide (Ln3+) fission products, Nd3+ and Pr3+, and their reactions with oxygen (O2-) impurities to form insoluble products in LiCl-NaCl-KCl eutectic salt. Combined absorption spectroscopy and electrochemical testing were used to track lanthanide concentrations. O2- impurity levels were controlled by adding Li2O to lanthanide-salt solutions. After the introduction of O2- impurities, Ln3+ concentrations were monitored via time-resolved absorption spectroscopy. Concentrations of both Ln3+ species in solution decreased with time as insoluble products formed. The initial impurity concentration controlled whether insoluble products were predominantly oxychlorides or mixtures of oxychlorides and oxides. However, absorption spectroscopy is limited for weakly absorbing species, such as Pr3+, and under conditions of high impurity concentrations where solutions can be turbid. To circumvent this limitation, the concentrations of Pr3+ were monitored with cyclic voltammetry (CV). Reaction rates and extent of Pr3+ removal from solution as monitored by CV agreed closely with results found from spectroscopic monitoring. This demonstrates that simultaneous electrochemical testing complements the capabilities of absorption spectroscopy to monitor reactions of fission products in molten salts.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The electrode–electrolyte interface of Cu via modulation excitation X-ray absorption spectroscopy

The development and application of modulation excitation X-ray absorption spectroscopy with sub-second resolution and better than 0.02% detection sensitivity unveils the kinetics of the anodic oxidation of Cu in bicarbonate electrolytes. Accessing the electrode–electrolyte interface under operating conditions and capturing time-resolved kinetics remain challenging in electrochemical studies. Copper's interfacial oxidation dynamics remain unclear despite extensive research. Modulation excitation X-ray absorption spectroscopy (ME-XAS) was used to probe Cu in 100 mM KHCO 3 with sub-second sensitivity, revealing that hydroxide forms 30 ± 10 ms before the appearance of Cu 2 O at positive potentials (0 to 0.5 V vs. RHE) near open-circuit conditions. From −0.4 to 0.8 V vs. RHE, hydroxide coverage reaches 49%, accompanied by a balanced presence of Cu( i ) and Cu( ii ) oxides. These insights into Cu interfacial redox behavior under intermittent renewable energy operation—relevant to CO 2 electrolyzer durability—enhance our fundamental understanding of electrochemical interfaces.

Garcia-Esparza, Angel T↗

Comparison of excitation temperature of a laser-produced plasma by combining emission and absorption spectroscopy

Measurement of the temporal evolution of laser-produced plasma temperature is very important for many of its applications, and several plasma diagnostic tools are routinely used by researchers. However, it is very challenging to measure the properties of the plasma at the early and late times of its evolution using a single diagnostic tool. In this study, we combined emission and laser absorption spectroscopy to compare the excitation temperatures of a laser-produced uranium plasma system. Several U I transitions in the near-infrared spectral range (775–800 nm) were considered, and the Boltzmann plot method was used to measure the excitation temperatures using both emission and absorption spectroscopy. Emission spectroscopy provided early-time temperature measurements of the plasma up to times 2–20 µs, while absorption spectroscopy provided temperature measurements at late times of plasma evolution (for times 5–80 µs). The emission and absorbance of U I transitions were found to follow the Boltzmann distribution, indicating the plasma is likely in the state of local thermodynamic equilibrium even at late times of its lifetime. The emission and absorption-based time-resolved excitation temperatures demonstrated good agreement at earlier times (≤15 µs) in the overlapped temporal region, while a deviation in the measured values was seen at times (≥15 µs), and potential reasons for such a disagreement are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Kramers–Kronig relation in attosecond transient absorption spectroscopy

The Kramers–Kronig relation (KKR) has a wide range of applications in extreme ultraviolet (XUV) and x-ray spectroscopy. However, the validity of KKR for many of these applications has not been systematically studied, while it is known to require careful attention in nonlinear and pump–probe experiments in optical domain spectroscopy. Here, we study the validity of KKR in XUV attosecond transient absorption spectroscopy pump–probe measurements both experimentally and theoretically using argon Fano resonances as a case study. Experiments are enabled by a phase-resolved method dubbed Complex Attosecond Transient-absorption Spectroscopy (CATS). Although the estimations based on the rotating-wave approximation suggest that KKR violation could be expected in the studied case, our results validate KKR and provide a solid basis for its application in a broad range of attosecond spectroscopy experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray absorption spectroscopy measurements of radiatively ionized argon gas

X-ray absorption spectroscopy is a diagnostic tool that can characterize the temperature and ionization state of a plasma. This technique requires experiments to characterize the platform, careful data calibration, and comparison with atomic models to understand the plasma parameters. We performed ionizing radiation wave experiments at the OMEGA Laser Facility that used an ∼ 80 eV X-ray source to heat an Argon (Ar) gas cell at fill pressures of 3 atm. To diagnose the Ar plasma, we used a capsule backlighter offset 10 mm from the gas cell, to produce X-rays that were absorbed by the ionized Ar gas. The absorption analysis was calibrated using the significant line structure in the backlighter spectrum, which served as independent energy fiducials enabling definitive measurements of a 50-eV shift in the energy of the Ar K-edge due to ionization. We compare the measured absorption spectra to two independent atomic models, PrismSPECT and SCRAM, and show that the observed K-edge shift in the heated gas is consistent with ionization up to Ar 4+ and temperatures of 10 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Open-source electrochemical cell for in situ X-ray absorption spectroscopy in transmission and fluorescence modes

X-ray spectroscopy is a valuable technique for the study of many materials systems. Characterizing reactions in situ and operando can reveal complex reaction kinetics, which is crucial to understanding active site composition and reaction mechanisms. In this project, the design, fabrication and testing of an open-source and easy-to-fabricate electrochemical cell for in situ electrochemistry compatible with X-ray absorption spectroscopy in both transmission and fluorescence modes are accomplished via windows with large opening angles on both the upstream and downstream sides of the cell. Using a hobbyist computer numerical control machine and free 3D CAD software, anyone can make a reliable electrochemical cell using this design. Onion-like carbon nanoparticles, with a 1:3 iron-to-cobalt ratio, were drop-coated onto carbon paper for testing in situ X-ray absorption spectroscopy. Cyclic voltammetry of the carbon paper showed the expected behavior, with no increased ohmic drop, even in sandwiched cells. Chronoamperometry was used to apply 0.4 V versus reversible hydrogen electrode, with and without 15 min of oxygen purging to ensure that the electrochemical cell does not provide any artefacts due to gas purging. The XANES and EXAFS spectra showed no differences with and without oxygen, as expected at 0.4 V, without any artefacts due to gas purging. The development of this open-source electrochemical cell design allows for improved collection of in situ X-ray absorption spectroscopy data and enables researchers to perform both transmission and fluorescence simultaneously. It additionally addresses key practical considerations including gas purging, reduced ionic resistance and leak prevention.

08 HYDROGEN↗

Recommendations to standardize reporting, execution, and interpretation of X-ray Absorption Spectroscopy measurements

In July of 2022, a National Science Foundation (NSF)- and US Department of Energy (DOE)-sponsored workshop was held on the topic of rigor and reproducibility (R&R) in thermal, heterogeneous catalysis. As a result of the workshop, a report has been published entitled "Addressing Rigor and Reproducibility in Thermal, Heterogeneous Catalysis"[1]. This manuscript summarizes one section of the report: "Recommendations for catalyst characterization by X-ray absorption spectroscopy". Here, the section focuses exclusively on X-ray absorption spectroscopy (XAS) and is narrowly focused on recommendations for the collection and interpretation of XAS data for routine experiments. Therefore, one should not expect a detailed guide for each different experiment that one may perform nor are the recommendations designed to be overly prescriptive. However, the report is designed to draw attention to key pitfalls and common problems in the collection, reporting, analysis and interpretation of XAS studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Flat Analyzer Polycapillary Spectrometer for X-ray Absorption Spectroscopy of Dilute Transition Metals at X-ray-Free Electron Lasers

X-ray absorption spectroscopy (XAS) coupled with highly intense pulses from an X-ray-free electron laser (XFEL) can be used to track ultrafast chemical dynamics. Nonetheless, measurements for dilute samples (≤1 mM) have been exceptionally challenging, as scattering background signals dominate over the sample’s X-ray fluorescence. We show that femtosecond time-resolved XAS measurements of sub-millimolar transition metal solutions are now possible at the Linac Coherent Light Source (LCLS) using a high-throughput polycapillary XAS spectrometer, designed, developed, and commissioned at LCLS and the Stanford Synchrotron Radiation Lightsource (SSRL). The instrument integrates three polycapillary optics that collect and collimate X-ray fluorescence emitted from the interaction point with a high solid angle. X-ray collimated fluorescence is then selectively diffracted by coupled graphite analyzer crystals. As a result, the contribution of scattered photons is suppressed. Experiments at the Pt L 3 -edge on 0.1 mM aqueous K 2 PtCl 6 (delivered via a 100 μm liquid jet) were successfully performed in the laser pump X-ray probe configuration at the LCLS XCS and XPP instruments. We report the transient spectra of hexachloroplatinate within the first 10 ps after a 266 nm photoexcitation. We observed a short-lived reduced intermediate (≈2 ps). The polycapillary X-ray spectrometer at LCLS now enables the efficient study of the dynamics of ultradilute transition metals in solution. This capability opens the door to investigating plasmonic systems, photocatalysts, enzymes, and other scarce and dilute samples.

LCLS↗

Detection limits for laser absorption spectroscopy of Li in laser ablation plumes

A high-sensitivity laser absorption spectroscopy (LAS) method is demonstrated for rapid and non-contact analysis of Li in solids. Glass samples with Li concentrations ranging from 1-500 ppm by mass are ablated in 5 Torr air, and time-resolved Li atomic absorption is measured using a tunable laser near 671 nm. Significant improvements in analytical performance over prior laser-induced breakdown techniques are demonstrated. Here, a single-shot limit of detection (LOD) of 180 ppb is shown for fixed wavelength operation, improving to 6 ppb with averaging over 1000 ablation shots (100 s acquisition time). Isotope-resolved Li absorption spectra are measured with a 17 ppb LOD in 40 s. Methods for optimizing LOD based on noise/averaging properties of LAS experiments in LA plumes are discussed.

(020.3260) Isotope shifts↗

Asynchronous x-ray multiprobe data acquisition for x-ray transient absorption spectroscopy

Laser pump X-ray Transient Absorption (XTA) spectroscopy offers unique insights into photochemical and photophysical phenomena. X-ray Multiprobe data acquisition (XMP DAQ) is a technique that acquires XTA spectra at thousands of pump-probe time delays in a single measurement, producing highly self-consistent XTA spectral dynamics. In this work, we report two new XTA data acquisition techniques that leverage the high performance of XMP DAQ in combination with High Repetition Rate (HRR) laser excitation: HRR-XMP and Asynchronous X-ray Multiprobe (AXMP). HRR-XMP uses a laser repetition rate up to 200 times higher than previous implementations of XMP DAQ and proportionally increases the data collection efficiency at each time delay. This allows HRR-XMP to acquire more high-quality XTA data in less time. AXMP uses a frequency mismatch between the laser and x-ray pulses to acquire XTA data at a flexibly defined set of pump-probe time delays with a spacing down to a few picoseconds. AXMP introduces a novel pump-probe synchronization concept that acquires data in clusters of time delays. Further, the temporally inhomogeneous distribution of acquired data improves the attainable signal statistics at early times, making the AXMP synchronization concept useful for measuring sub-nanosecond dynamics with photon-starved techniques like XTA. In this paper, we demonstrate HRR-XMP and AXMP by measuring the laser-induced spectral dynamics of dilute aqueous solutions of Fe(CN) 6 4₋ and [Fe II (bpy) 3 ] 2+ (bpy: 2,2'-bipyridine), respectively.

47 OTHER INSTRUMENTATION↗