Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerated lifetime testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Long-Term Reliability of SiGe/Si HBTs From Accelerated Lifetime Testing

Accelerated lifetime tests were performed on double-mesa structure Si(0.7)Ge(0.3)/Si npn heterojunction bipolar transistors, grown by molecular beam epitaxy, in the temperature range of 175 C-275 C. The transistors (with 5x20 sq micron emitter area) have DC current gains approx. 40-50 and f(sub T) and f(sub max) of up to 22 GHz and 25 GHz, respectively. It is found that a gradual degradation in these devices is caused by the recombination enhanced impurity diffusion (REID) of boron atoms from the p-type base region and the associated formation of parasitic energy barriers to electron transport from the emitter to collector layers. This REED has been quantitatively modeled and explained, to the first order of approximation, and the agreement with the measured data is good. The mean time to failure (MTTF) of these devices at room temperature under 1.35 x 10(exp 4) A/sq cm current density operation is estimated from the extrapolation of the Arrhenius plots of device lifetime versus reciprocal temperature. The results of the reliability tests offer valuable feedback for SiGe heterostructure design in order to improve the long-term reliability of the devices and circuits made with them. Hot electron induced degradation of the base-emitter junction was also observed during the accelerated lifetime testing. In order to improve the HBT reliability endangered by the hot electrons, deuterium sintered techniques have been proposed. The preliminary results from this study show that a deuterium-sintered HBT is, indeed, more resistant to hot-electron induced base-emitter junction degradation.

Bhattacharya, Pallab↗

Accelerated Lifetime Testing of Main Shaft Seals for Tidal Turbine Rotors

This document will briefly discuss the observations and results from an NREL conducted accelerated lifetime testing of the main shaft seal for the Verdant Power fifth generation Gen5 underwater Tidal Energy Converter (TEC) turbine, which successfully performed at the RITE project in 2020-2021. In order to evaluate a 5-year Service Interval ( SI) for this component, testing at NREL operated the main shaft seal nearly continuously for over 135 (text says 130 days on page 5 and 125 days on page 7 and 137 days on page 11) days at a rotational velocity of 160 rpm while the test stand recorded water pressure, barrier fluid pressure, temperature, and number of cycles., representing ~ 40% of the SI. An additional separate test was conducted to measure the aging behavior of the rubber drive rings. The water pressure reservoir was held constant as 29 psi. Barrier fluid pressure remained relatively constant throughout the duration of the test but was seen to sink to as low as 10.1 psi. No barrier fluid leakage was observed throughout the test. A sudden failure occurred within the seal after the power to test machine was interrupted for a scheduled building maintenance procedure. Upon restarting, the main shaft seal lost all ability to prevent water ingress. The exact cause is not known but is believed to be either a seal assembly issue or a change in the alignment of the seal components during or following the power outage. Following seal disassembly, significant wear was seen on one of the graphite sealing rings. Based on these results it is recommended that a follow-on TEAMER be conducted to rectify protocol and assembly issues to further evaluate SI of this component. The support and participation of Verdant Power Inc, Dovetail Solutions LLC and Garlock Manufacturing Inc were instrumental in understanding the results. NREL thanks them for their significant effort.

13 HYDRO ENERGY↗

Accelerated Lifetime Test of the SRF Dressed Cavity/Tuner System for LCLS II HE Project

The off-frequency detune method is being considered for application in the LCLS-II-HE superconducting linac to produce multi-energy electron beams for supporting multiple undulator lines simultaneously [1]. Design of the tuner has been changed to deliver roughly 3 times larger frequency tuning range. Working requirements for off-frequency operation (OFO) state that cavities be tuned at least twice a month. This specification requires the in-crease of the tuner longevity by 20 times compared with LCLS-II demands. Accelerated longevity tests of the LCLS-II HE dressed cavity with tuner were conducted at FNAL's HTS. Detail analysis of wearing and impacts on performances of the tuner's piezo and stepper motor actuators will be presented. Additionally, results of longevity testing of the dressed cavity bellow, when cooled down to 2 K and compressed by 2.6 mm for roughly 2000 cycles, will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analytical and experimental investigation of the feasibility of accelerated lifetime testing of materials exposed to an atomic oxygen beam

The interaction of atomic particles with surfaces is of both scientific and technological interest. Past work emphasizes the measurement of high-energy sputtering yields. Very little work utilized low-energy beams for which chemical and electronic effects can be important. Even less work has been carried out using well-defined low-energy projectiles. The use of low-energy, reactive projectiles permits one to investigate surface processes that have not been well characterized. As the energy of the projectile decreases, the collisional cascades and spikes, that are common for high-energy projectiles, become less important, and chemical and electronic effects can play a significant role. Aspects of particle-surface interactions are of concern in several areas of technology. For example, the erosion, desorption, and glow of surfaces of spacecraft in orbit are important in the arena of space technology. The materials studied under this contract are of possible use on the exterior portions of the power generation system of Space Station Freedom. Under the original designs, Space Station Freedom's power generation system would generate potential differences on the surface as high as 200 volts. Ions in the plasma that often surround orbiting vehicles would be accelerated by these potentials leading to bombardment and erosion of the exposed surfaces. The major constituent of the atmosphere, approximately 90 percent, in the low earth orbit region is atomic oxygen. Since atomic oxygen is extremely reactive with most materials, chemical effects can arise in addition to the physical sputtering caused by the acceleration of the oxygen ions. Furthermore, the incident oxygen ions can remain embedded in the exposed surfaces, altering the chemical composition of the surfaces. Since the effective binding energy of a chemically altered surface can be quite different from that of the pure substrate, the sputtering yield of a chemically altered surface is usually different also. The low-energy O+ sputtering yield measurements, reported here, will help quantify the erosion rates for materials exposed to the low-earth orbit environment. These measurements are of technological importance in another respect. In most surface analysis techniques, a surface is bombarded with ions, electrons or photons. Information concerning the structure of the surface and near-surface bulk, abundance of impurities and defects, as well as other surface properties are obtained either from the desorbed species or from the scattered projectiles. Because of their low penetration depth, low-energy ions provide an advantage over other techniques because they provide information that is more indicative of conditions on the surface rather than integrated effects arising from deeper in the bulk. A better understanding of the microscopic processes involved in these interactions is not only of basic scientific interest, but will also aid the scientific community by increasing the accuracy and usefulness of these surface analysis techniques.

Albridge, Royal↗

Long-Term Reliability of High Speed SiGe/Si Heterojunction Bipolar Transistors

Accelerated lifetime tests were performed on double-mesa structure Si/Si0.7Ge0.3/Si npn heterojunction bipolar transistors, grown by molecular beam epitaxy, in the temperature range of 175C-275C. Both single- and multiple finger transistors were tested. The single-finger transistors (with 5x20 micron sq m emitter area) have DC current gains approximately 40-50 and f(sub T) and f(sub MAX) of up to 22 GHz and 25 GHz, respectively. The multiple finger transistors (1.4 micron finger width, 9 emitter fingers with total emitter area of 403 micron sq m) have similar DC current gain but f(sub T) of 50 GHz. It is found that a gradual degradation in these devices is caused by the recombination enhanced impurity diffusion (REID) of boron atoms from the p-type base region and the associated formation of parasitic energy barriers to electron transport from the emitter to collector layers. This REID has been quantitatively modeled and explained, to the first order of approximation, and the agreement with the measured data is good. The mean time to failure (MTTF) of the devices at room temperature is estimated from the extrapolation of the Arrhenius plots of device lifetime versus reciprocal temperature. The results of the reliability tests offer valuable feedback for SiGe heterostructure design in order to improve the long-term reliability of the devices and circuits made with them. Hot electron induced degradation of the base-emitter junction was also observed during the accelerated lifetime testing. In order to improve the HBT reliability endangered by the hot electrons, deuterium sintered techniques have been proposed. The preliminary results from this study show that a deuterium-sintered HBT is, indeed, more resistant to hot-electron induced base-emitter junction degradation. SiGe/Si based amplifier circuits were also subjected to lifetime testing and we extrapolate MTTF is approximately 1.1_10(exp 6) hours at 125iC junction temperature from the circuit lifetime data.

Ponchak, George E.↗

MODELING AND METHOD FOR OPTICAL PERFORMANCE OF A RECEIVER COATING AND ITS DEGRADATION DUE TO OPERATION

The optical properties of the coating used on a concentrated solar power (CSP)’s receiver directly impact the performance of the power plant. Receiver coatings are designed to absorb as much heat as possible and transfer it to the circulating fluid. Over time, the absorptivity of the receiver coating degrades due to environmental and operational conditions. This project aims to (1) create a test apparatus that allows coatings to undergo accelerated lifetime testing under conditions that mimic what the coating will experience on-tower; and (2) develop a mathematical model that based on the test data predicts absorptivity over time. To create the mathematical model, samples of BrightSource Energy’s Gen1 and Gen2 coatings were tested first looking at individual failure modes (such as high temperature cycling) and then for combined failure modes in the newly developed apparatus. In addition to taking optical measurements, the samples were destroyed to allow for metalogical evaluation to understand what was happening on a microscopic level. Pre-existing models from the literature that describe accelerated testing as well as individual phenomena observed in the coating were then combined to create the model. Additionally, the Gen2 and Gen3 coatings are being testing at the Plataforma Solar de Almería (PSA) facility in Almeria, Spain to confirm that the apparatus test results are similar to those received on-sun. (PSA’s facility closely mimics on-tower conditions). The goal is to enable industry players to test coatings using the new apparatus, gather absorptivity measurements (without needing to destroy samples), and input the information into the model to determine how the coating will perform over time, thus allowing the optical performance of coatings to be compared even before they are used on-tower. The model will be publicly available by the end of the project (currently projected as December 2024).

14 SOLAR ENERGY↗

Long life communication satellites: Electric power supply during the eclipse period

The electric batteries, essentially nickel-cadmium for French satellites such as D1 A, D1 C, D1 D, D2 B, D5 A, D5 B, etc. and the batteries for such satellites as Symphonie, ANS, INTASAT, ESRO 4, and COS-B are discussed. The experience obtained led to the development of long lifetime batteries for communication satellites. Real simulation tests showed a lifetime of four years and accelerated lifetime tests of twelve years. These batteries will be applied in OTS, METEOSAT, and Marots. At the same time, new batteries are being developed, based on nickel-hydrogen or on silver-hydrogen, which should provide longer lifetime and better reliability.

Font, S.↗

Prototype SSR2 Tuner Procurement and Testing at IJCLab for PIP-II Project

IJCLab is involved in the PIP-II project on the design and development of accelerator components for the SSR2 (Single Spoke Resonator type 2) section of the superconducting linac. Five prototype tuners have been built and are being tested at IJCLab. After a short description of the tuner, this paper reports on the procurement strategy and the performance observed at both room and low temperatures in vertical cryostat test with SSR2 prototype cavities. This paper will also share results on accelerated lifetime tests performed in a dedicated nitrogen-cooled cryostat.

43 PARTICLE ACCELERATORS↗

Multiparameter laser performance characterization of liquid crystals for polarization control devices in the nanosecond regime

Abstract Interactions of liquid crystals (LC’s) with polarized light have been studied widely and have spawned numerous device applications, including the fabrication of optical elements for high-power and large-aperture laser systems. Currently, little is known about both the effect of incident polarization state on laser-induced–damage threshold (LIDT) and laser-induced functional threshold (LIFT) behavior at sub-LIDT fluences under multipulse irradiation conditions. This work reports on the first study of the nanosecond-pulsed LIDT’s dependence on incident polarization for several optical devices employing oriented nematic and chiral-nematic LC’s oriented by surface alignment layers. Accelerated lifetime testing was also performed to characterize the ability of these devices to maintain their functional performance under multipulse irradiation as a function of the laser fluence at both 1053 nm and 351 nm. Results show that the LIDT varies as a function of input polarization by 30–80% within the same device, while the multipulse LIFT (which can differ from the nominal LIDT) depends on irradiation conditions such as laser fluence and wavelength.

47 OTHER INSTRUMENTATION↗

Increasing Multilayer Ceramic Capacitor Lifetime With Bipolar Voltage Cycling

Enhancing the lifetime of multilayer ceramic capacitors (MLCCs) is critical in many aerospace, naval, or electrical grid applications, where device failure could lead to catastrophic consequences. The migration of oxygen vacancies from the ceramic to the electrode interface under constant bias is known to reduce the lifetime of oxide-based MLCCs. Bias cycling presents an opportunity to enhance MLCC lifetime by reducing oxygen vacancy migration. The ideal frequency range is expected to lie between frequencies low enough to avoid self-heating but high enough to avoid interfacial defect formation. However, the impact of low-frequency bipolar voltage cycling (BVC) on MLCC degradation mechanisms has not been well studied. This work investigates the impact of periodic BVC on the degradation of MLCCs through highly accelerated lifetime testing (HALT) on X7R capacitors. HALT tests were conducted at 255 °C and 60 V using different switching frequencies: 0 (dc), 0.1, 2.5, and 10 Hz. BVC was found to improve the lifetime of MLCCs compared to dc test conditions. MLCCs tested at 10-Hz BVC showed a 311% increase in average time to failure compared to the dc case. Impedance spectroscopy shows that BVC decreases the rate of resistance degradation within MLCCs, indicating that oxygen vacancy migration to the electrodes is mitigated. The impedance spectra taken on BVC samples highlight how grain boundaries play a vital role in trapping oxygen vacancies. Periodic cycling causes oxygen vacancies to become trapped at grain boundaries, resulting in oxygen vacancies taking longer to reach the electrode interface and thus increasing MLCC lifetime. This work highlights not only how BVC can be used to increase MLCC lifetime but also how periodically cycling MLCCs could increase lifetime in extreme environments, such as at elevated temperatures and electric fields.

Chuong, Kayla Y.↗

Dispenser Reliability: Materials R&D. A Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) Report

Dispensers are the top cause of maintenance events and down-time at hydrogen fueling stations. In an effort to help characterize and enable improvements in dispenser reliability, an extensive accelerated lifetime testing set-up was designed and built at NREL involving components typically part of dispensing operations at fueling stations. Device Under Test (DUTs) included different components such as normally open valves, normally closed valves, fueling nozzles, breakaways devices and filters. Conditions of testing included pressures, and flow rates similar to light duty fuel cell electric vehicles fueling at -40°C, and -20°C for thousands of cycles in hydrogen. Tested components (failed and non-failed) were disassembled at SNL and polymeric O-rings were carefully retrieved and cataloged for chemical and physical characterization. Data collected was compared to similar O-rings from unexposed or non-tested components for hydrogen effects, and failure modes. Degradation analyses, based on select polymer chemistries common across all component types, their location within components, visual assessment of damage coupled with strong hydrogen effects from chemical characterization, was completed and presented to NREL and DOE. Overall, the failure rate amongst the components was not as high as expected for the test conditions. Among the component types tested, breakaways were the most susceptible to damage under these test conditions, with fueling nozzles a close second. The proper combination of selection of the right polymer and optimum component design was found to make a strong difference in component reliability under severe dispenser operating conditions. Physical degradation of polymers, rather than chemical changes due to low temperature hydrogen exposure, is more prevalent as failure mode for these test conditions. The nature and the extent of the degradation was much less at -20°C as compared to -40°C. The damage and failure rates were higher at lower temperatures than at higher test temperatures. As expected, increasing the number of cycles at the lowest test temperature (-40°C) increased damage. This indicates that cycling at the low temperature of -40°C required by SAE J2601 can reduce component life in fuel dispensing operations

08 HYDROGEN↗

Machine-Learning-Assisted Enhancement of Perovskite Stability and Photovoltaic Performance

Lab scale perovskite solar cells (PSCs) have reached power conversion efficiencies on par with silicon solar cells. Their potential for low-cost manufacturing combined with high performance make them attractive for commercialization. The major challenge impeding widespread development of PSCs is their stability. Halide perovskites are vulnerable to decomposition in the presence of moisture, oxygen, light, and heat. Furthermore, the chemical differences between halide perovskites and conventional semiconductors used in photovoltaics (e.g., silicon, chalcogenides, and III-V compounds) may render established accelerated lifetime testing protocols inaccurate.

14 SOLAR ENERGY↗

Ultra-High Efficiency and Stable All-Perovskite Tandem Solar Cells

In the project period, the research team has fabricated more than 6,000 single-junction wide-bandgap (wide-E g ) and low-bandgap (low-E g ) perovskite solar cells (PSCs) and more than 2,000 all-perovskite tandem solar cells (APTSCs). The best-performing wide-E g and low-E g PSCs and APTSCs showed PCEs greater than 19%, 23%, and 30%, respectively. The average PCEs for wide-E g and low-E g PSCs and APTSCs fabricated by the benchmark processes are (18.5 ± 0.4)%, (21.9 ± 0.8)%, and (26.8 ± 2.1)%, respectively. We have demonstrated APTSCs with T 80 lifetime of more than 1,000 h, which were measured by maximum power point tracking (MPPT) under one sun operation in the air. The team has also utilized various advanced characterization techniques to study the optical and electrical properties of wide-E g and low-E g perovskite materials and devices, developing a better understanding of the unique working principle and degradation mechanism of APTSCs. The team has met most GNG decision criteria except for the stability goal of APTSCs under 85 °C/85 RH accelerated lifetime test (ALT). The shortfall of the device ALT stability is mainly limited by the intrinsic instability of Sn-Pb perovskites under illumination at elevated temperatures. The team discussed with stakeholders in the PV academic and industry about these durability concerns and concluded that this is the major technical barrier preventing the market entry of APTSCs. Future fundamental study and R&D work are needed to advance this promising technology.

14 SOLAR ENERGY↗

Experience of developing highly reliable Tuner components (piezo actuators and cold stepper motor actuators) for SRF Linac

The resonance control team at FNAL has led the design of the LCLS-II SRF Linac SRF cavity tuner subsystem. The Linac is expected to operate for over 30 years, and the longevity of the tuner is crucial to the overall reliability of the Linac. When the tuner's design was started, there were no active actuators (stepper and piezo) that could meet the longevity requirements of the Linac. The FNAL resonance control team, in collaboration with industrial partners (Phytron and PI), has developed actuators that have been shown to withstand a cryogenic and insulating vacuum environment for over 100 years in accelerated lifetime tests. Details of actuators design and longevity testing will be presented. Now, practically all (small and large) SRF systems that are under construction around the world are using actuators developed at FNAL. A review of possible actuators improvement will be presented.

Pischalnikov, Yuriy [Fermilab]↗

Characterization of Fine-Pitch Interconnects for Long-Lifetime HI Applications

This conference talk discusses optimizing gold-gold and gold-ENIG fine-pitch interconnections for Heterogeneous Integration applications, with a focus on longevity. We first look at electrical data from gold-gold bumps subjected to highly accelerated lifetime testing. Then, we discuss using chemical and physical data as a predictor for ENIG bump flip-chip success.

Humphrey, Nicholas James [Sandia National Laborato↗