Modeling betatron radiation using particle-in-cell codes for plasma wakefield accelerator diagnostics
The analysis of plasma wakefield acceleration experimental measurements, particularly in the characterization of photons emitted through the betatron radiation mechanism, requires the development of accurate numerical models. These computational models are crucial for supporting modern instrumentation designed to measure the single-shot, double-differential angular-energy radiation spectra resulting from interactions between beams and plasmas. Motivated by the needs of such applications, this paper presents detailed numerical models of betatron radiation generated in beam-plasma acceleration experiments. These models are based on the integration of the Liénard-Wiechert (LW) potentials, applied to computed particle trajectories. The particle trajectories are generated using three distinct methods: first, by tracking particles through idealized fields in the blowout regime of PWFA; second, by obtaining trajectories using the fast quasistatic particle-in-cell (PIC) code quickpic; and third, obtaining trajectories from the fully self-consistent PIC code osiris. To ensure the accuracy and reliability of these models, the paper includes various benchmark tests using analytical expressions, as well as employing the PIC code epoch, which takes an alternative approach by using a Monte Carlo quantum electrodynamics (QED)-based radiation model. Additionally, the paper presents simulations of the expected experimental betatron radiation spectra, taking into account parameters relevant to PWFA and plasma photocathode experiments at the SLAC FACET-II facility.
First results from a high-frame-rate, multi-GHz ionizing particle detection system geared toward accelerator diagnostic applications
An integrated detection system, consists of a thin diamond sensor incorporated into a compact signal loop, coupled in turn to an application-specific integrated circuit readout chip, has been tested for the first time, using ps-duration electron pulses from the Next Linear Collider Test Accelerator at the SLAC National Accelerator Laboratory. For readout frame rates as high as 120 kHz, the detection system is shown to achieve a linear dynamic range of 10 3 and a bandwidth of 4–5 GHz, with no ringing seen on the tail of the output pulse. These results represent the best-performing multi-GHz ionizing particle detection system achieved to date.
Additively Manufactured Z-channel Detectors for Heavy Ion Accelerator Diagnostics
Explore the source record for details and available documents.
Accelerator Diagnostic Techniques Using Time-Domain Data from a Bunch-by-bunch Longitudinal Feedback System
Explore the source record for details and available documents.
Diagnostic measurements in an alkali plasma Hall accelerator.
Diagnostic measurements in alkali plasma Hall accelerator /alpha/ including azimuth and axial velocity components, energy flux, total beam power, etc
Diagnostics of accelerating plasma Semiannual progress report, 1 Sep. 1968 - 28 Feb. 1969
Accelerating plasma diagnostics - validity of local thermal equilibrium assumption in electromagnetic shock tubes, and current-sheet velocity in coaxial plasma accelerator
Conditional guided generative diffusion for particle accelerator beam diagnostics
Abstract Advanced accelerator-based light sources such as free electron lasers (FEL) accelerate highly relativistic electron beams to generate incredibly short (10s of femtoseconds) coherent flashes of light for dynamic imaging, whose brightness exceeds that of traditional synchrotron-based light sources by orders of magnitude. FEL operation requires precise control of the shape and energy of the extremely short electron bunches whose characteristics directly translate into the properties of the produced light. Control of short intense beams is difficult due to beam characteristics drifting with time and complex collective effects such as space charge and coherent synchrotron radiation. Detailed diagnostics of beam properties are therefore essential for precise beam control. Such measurements typically rely on a destructive approach based on a combination of a transverse deflecting resonant cavity followed by a dipole magnet in order to measure a beam’s 2D time vs energy longitudinal phase-space distribution. In this paper, we develop a non-invasive virtual diagnostic of an electron beam’s longitudinal phase space at megapixel resolution (1024 × 1024) based on a generative conditional diffusion model. We demonstrate the model’s generative ability on experimental data from the European X-ray FEL.
Scorpius Accelerator Emittance Diagnostic Design
The 14th International Particle Accelerator Conference (IPAC’23) will be held in Venice, Italy from 7 to 12 May 2023 at the Venice Convention Centre. Website: https://www.ipac23.org/ Presenter: Mark Raphaelian Dear Mark, we acknowledge reception of your abstract #1268 for IPAC'23 - 14th International Particle Accelerator Conference. Here follow the details: Title: The Design of the Emittance Diagnostic for the Scorpius Accelerator Classification: MC6.T03: Beam Diagnostics and Instrumentation Type of presentation: Poster Presentation Submitter: Mark Raphaelian Authors: Mark Raphaelian Co-Authors: Daniel Dzenitis, Franz Weber, Nathaniel Pogue, Sean Littleton, Steven Falabella, Patrick Duffy, William Stem
An in situ accelerator-based diagnostic for plasma-material interactions science on magnetic fusion devices
This paper presents a novel particle accelerator-based diagnostic that nondestructively measures the evolution of material surface compositions inside magnetic fusion devices. The diagnostic's purpose is to contribute to an integrated understanding of plasma-material interactions in magnetic fusion, which is severely hindered by a dearth of in situ material surface diagnosis. The diagnostic aims to remotely generate isotopic concentration maps on a plasma shot-to-shot timescale that cover a large fraction of the plasma-facing surface inside of a magnetic fusion device without the need for vacuum breaks or physical access to the material surfaces. Our instrument uses a compact (∼1 m), high-current (∼1 milliamp) radio-frequency quadrupole accelerator to inject 0.9 MeV deuterons into the Alcator C-Mod tokamak at MIT. We control the tokamak magnetic fields – in between plasma shots – to steer the deuterons to material surfaces where the deuterons cause high-Q nuclear reactions with low-Z isotopes ∼5 μm into the material. The induced neutrons and gamma rays are measured with scintillation detectors; energy spectra analysis provides quantitative reconstruction of surface compositions. An overview of the diagnostic technique, known as accelerator-based in situ materials surveillance (AIMS), and the first AIMS diagnostic on the Alcator C-Mod tokamak is given. Experimental validation is shown to demonstrate that an optimized deuteron beam is injected into the tokamak, that low-Z isotopes such as deuterium and boron can be quantified on the material surfaces, and that magnetic steering provides access to different measurement locations. The first AIMS analysis, which measures the relative change in deuterium at a single surface location at the end of the Alcator C-Mod FY2012 plasma campaign, is also presented.
Diagnostics of accelerating plasma Semiannual progress report, 1 Mar. - 31 Aug. 1968
Plasma diagnostics in electromagnetically driven shock tubes using laser scattering methods as compared to spectroscopic techniques
Development of an accelerator-based diagnostic for plasma-facing surfaces in magnetic confinement devices
The focus of this work was the development of the Accelerator-based In-situ Material Surveillance (AIMS) diagnostic. The understanding of plasma-material interaction processes in fusion devices has been greatly hampered by the lack of ability to measure the surface ~micron layers of solid surfaces that are in contact with and greatly modified by the boundary fusion plasma. AIMS was the first diagnostic developed and deployed that allowed non-destructive surface measurements with adequate spatial and time resolution. The deployment was primarily carried out on the Alcator C-Mod tokamak. AIMS diagnostic goal is to remotely generate isotopic concentration maps on a plasma shot-to-shot timescale that cover a large fraction of the plasma-facing surface inside of a magnetic fusion device without the need for vacuum breaks or physical access to the material surfaces. The diagnostic used a compact (~ 1 m), high-current (~ 1 milliamp) radio-frequency quadrupole accelerator to inject 0.9 MeV deuterons into the Alcator C-Mod tokamak. The tokamak magnetic fields were controlled – in between plasma shots – to steer the deuterons to material surfaces where the deuterons cause high-Q nuclear reactions with low-Z isotopes up to 5 microns into the material. The induced neutrons and gamma rays are measured with scintillation detectors; energy spectra analysis provides quantitative reconstruction of surface compositions. Experimental validation showed that low-Z isotopes such as deuterium and boron can be quantified on the material surfaces, and that magnetic steering provides access to different measurement locations. AIMS measurements of D retention on inner wall PFCs were acquired during diverted and limited plasma operations and during wall conditioning experiments om Alcator C-Mod. Intershot measurements demonstrate the local erosion and co-deposition of boron films on PFC surfaces with a constant D-B ratio. This is consistent with previous results suggesting that D co-=deposition with boron is insufficient to account for the net retention observed in Alcator C-Mod. Changes in deuterium concentration during boronization, electron cyclotron and glow cleanings were also measured. These initial results were limited to studying low-Z surface properties, because the Coulomb barrier precludes nuclear reactions between high-Z elements and the ~1 MeV AIMS deuteron beam. In order to measure the high-Z erosion of interest in Alcator C-Mod and future fusion devices, a new technique using deuteron-induced gamma emission and a low-Z depth marker was developed using implanted depth markers as a method of measuring bulk erosion and redeposition. This method is dubbed DEA: Depth marker Erosion with AIMS. DEA simulations and experiments were used to validate this technique, both in the laboratory and via experiments in the EAST tokamak. Based on these results, the DEA technique, using ion beam implanted depth markers as a reference to the surface in order to monitor surfaces for erosion and redeposition, is a viable option as a diagnostic, both in and ex situ. These markers show stability to temperature, the tokamak environment, and multiple probing beams. The ex-situ (eDEA) method, which uses resonances in the cross sections of gamma producing reactions to track the surface, was used to successfully measure erosion in samples that were exposed in the EAST tokamak. The in-situ (iDEA) method, which uses the gamma yield ratio to monitor changes to the surface, was used to differentiate between markers implanted to different depths. Both techniques were successfully simulated, and both presented unique challenges experimentally and in data analysis. In particular, the eDEA probing beam was found to have energy variations leading to initial experimental uncertainty, and the iDEA gamma spectra had conflicting gamma peaks which make data analysis difficult. However, the end result is a promising framework for a diagnostic technique that supplements the abilities of AIMS and expands the possibilities of surface diagnostics in fusion devices. While the results of this work are overwhelmingly encouraging for further development of AIMS in general, and the DEA technique specifically, several areas require significant development before this diagnostic is as robust and widely applicable as a surface diagnostic ought to be. Recommended future work includes the development of a cross section/yield measurement database, erosion tests with secondary verification of results using a fiducial mark from a focused ion beam, and acquiring a new accelerator with a more reliable high energy proton and deuterium beam The project resulted in 14 publications, including the PhD theses of three MIT graduate students, cited in the included bibliography.
The EMMA Accelerator, a Diagnostic Systems Overview
The 'EMMA' Non-Scaling Fixed Field Alternating Gradient (ns-FFAG) international project is currently being commissioned at Daresbury Laboratory, UK. This accelerator has been equipped with a number of diagnostic systems to facilitate this. These systems include a novel time-domain-multiplexing BPM system, moveable screen systems, a time-of-flight instrument, Faraday cups, and injection/extraction tomography sections to analyze the single bunch beams. An upgrade still to implement includes the installation of wall current monitors. This paper gives an overview of these systems and shows some data and results from the diagnostics that have contributed to the successful demonstration of a serpentine acceleration by this novel accelerator.
Model-driven prediction for accelerator magnet diagnostics to improve operation reliability
Reliability is one of the most critical metrics for accelerator operation, especially in user facilities. To reduce costly facility downtime and provide an operational environment where system performance can be reliably predicted in support of scientific studies, we are developing a model-driven approach for prediction and anomaly detection. Here, in this study, we present the application of a model-driven method that employs a linear regression model to predict the future temperature, in real time, of accelerator magnets at the NSLS-II light source. This approach enables proactive identification of magnet-heating issues, facilitating magnet flushing prior to the occurrence of permanent damage without interrupting machine operation. The implementation of this method in the NSLS-II control room is described and the analysis of the online results is presented. The results demonstrate the model’s effectiveness in providing early alerts to engineers and improving the reliability of accelerator operations.
Rapid Acceleration of Diagnostics: RADx (Tech + ATP)
This virtual symposium was held to highlight the impact the U.S. Department of Energy’s (DOE) National Virtual Biotechnology Laboratory (NVBL) has had utilizing the unique capabilities of the DOE to tackle the science and technology challenges associated with COVID-19, and to discuss areas in which the NVBL can have impact in the future. With perspectives from Chris Fall, Director, Office of Science, DOE, and William A. Bookless, Principal Deputy Administrator of the National Nuclear Security Administration, the event featured Presentations from lead investigators reporting progress in: Epidemiological modeling, Therapeutics, Testing, Understanding transport of the virus, and Solving issues around supply chain challenges. In addition, keynote speakers from outside the NVBL discussed the upcoming science and technology needs in computing, testing and surveillance, and vaccines. The event was aimed at the S&T community, media, and general public.
Diagnostics of accelerating plasma Semiannual progress report, 1 Sep. 1966 - 28 Feb. 1967
Electron temperatures, density distributions, and shape of current sheets determined in coaxial plasma accelerators
Diagnostics of accelerating plasma Semiannual progress report, 1 Mar. - 31 Aug. 1967
Electric polarity effect in coaxial plasma accelerators - possible mechanism for behavior of current sheet