Search NASA⌕ Search

SEARCH · Search NASA

Results for “acceptance angle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Sheath effects on current collection by particle detectors with narrow acceptance angles

Restriction of the aperture acceptance angle of an ion or electron trap on an attracting spacecraft significantly alters the volt-ampere characteristics of the instrument in a low Mach number plasma. It is shown when the angular acceptance of the aperture is restricted the current to the collector tends to be independent of the Debye length. Expressions for the RPA characteristics for both a thin sheath and a thick sheath are derived; and it is shown that as the aperture is narrowed the curves tend toward equivalence.

Singh, N.↗

The role of acceptance angle in measurements with ion energy analyzers: Study by numerical simulations

The importance of an acceptance angle in the plasma diagnostics with ion energy analyzers is investigated by means of numerical simulations. It is shown that wide acceptance angles result in low energy tails in measured ion distribution functions (IDF{sub x}). For flowing plasmas or plasmas with beams, the orientation of the analyzer's orifice gives different results due to bending of ion trajectories in the vicinity of the analyzer. It is demonstrated that the maximum in the IDF{sub x} is at energies lower than the plasma potential. Simulations are done with DIP3D, a three-dimensional particle-in-cell code.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Wide acceptance angle, high concentration ratio, optical collector

The invention is directed to an optical collector requiring a wide acceptance angle, and a high concentration ratio. The invention is particularly adapted for use in solar collectors of cassegrain design. The optical collector system includes a parabolic circular concave primary mirror and a hyperbolic circular convex secondary mirror. The primary mirror includes a circular hole located at its center wherein a solar collector is located. The mirrored surface of the secondary mirror has three distinct zones: a center circle, an on-axis annulus, and an off-axis section. The parabolic shape of the primary mirror is chosen so that the primary mirror reflects light entering the system on-axis onto the on-axis annulus. A substantial amount of light entering the system off-axis is reflected by the primary mirror onto either the off-axis section or onto the center circle. Subsequently, the off-axis sections reflect the off-axis light toward the solar collector. Thus, off-axis light is captured which would otherwise be lost to the system. The novelty of the system appears to lie in the configuration of the primary mirror which focuses off-axis light onto an annular portion of the secondary mirror to enable capture thereof. This feature results in wide acceptance angle and a high concentration ratio, and also compensates for the effects of non-specular reflection, and enables a cassegrain configuration to be used where such characteristics are required.

Kruer, Mark Arthur↗

All-Glass Metasurfaces for Ultra-Broadband and Large Acceptance Angle Antireflectivity: from Ultraviolet to Mid-Infrared

For many optics technologies, such as display screens, solar cells, laser systems, and eyeglasses, antireflective (AR) coatings are well integrated; these applications frequently benefit from the ability to function as broadband AR. Here, in this work, all-glass metasurfaces are reported on, exhibiting a measured reflectance of 0.18% ± 0.23% per interface, averaged across wavelengths spanning from 350 nm (ultraviolet) to 2350 nm (mid-infrared); to the best of knowledge, this is the first-ever demonstration of an AR layer capable of this. Furthermore, acceptance angles up to 100° (angle of incidence = ±50°) results in % R < 0.6% per interface over the band 350–1300 nm for P-polarization and S-polarization, with wavelength averaged reflectance values 0.04% ± 0.05% and 0.11% ± 0.15%, respectively – another technological first. The process advancements presented here allow for reflectance suppression over a broad range of wavelengths, angles, and polarizations.

36 MATERIALS SCIENCE↗

Wide acceptance angle, high concentration ratio, optical collector

A cassegrain optical system provides improved collection of off-axis light yet is still characterized by a high concentration ratio. The optical system includes a primary mirror for collecting incoming light and reflecting the light to a secondary mirror which, in turn, reflects the light to a solar cell or other radiation collection device. The primary mirror reflects incoming on-axis light onto an annular section of the secondary mirror and results in the reflection of a substantial amount of incoming off-axis light onto the remainder of the secondary mirror. Thus light which would otherwise be lost to the system will be captured by the collector. Furthermore, the off-axis sections of the secondary mirror may be of a different geometrical shape than the on-axis annular section so as to optimize the amount of off-axis light collected.

Kruer, Mark A.↗

Electron Emission From Slightly Oxidized Delta-stabilized Plutonium Generated by its Radioactivity, and Radiation Induced Ionization and Dissociation of Hydrogen at its Surface

Energy dependent electron emission between zero and 1.4 keV generated by the natural reactivity of plutonium was measured by an electrostatic spectrometer with known acceptance angle and acceptance area. The electron spectral intensity decreases continuously except for a distinctive feature of unknown origin at approximately 180eV. The spectrum was converted to energy dependent electron flux (e/cm 2 } s) using the assumption that the emission has a cosine angular distribution. The energy dependent electron mean free path in gases and literature cross sections for electron induced reactions were used to determine the number of ionization and dissociation reactions per cm 2 second, found to be about 8*10 8 /cm 2 s and 1.5*10 8 /cm 2 s, respectively, for hydrogen. These results are to be used with caution until complementary measurements can be made, e.g. independent measurement of the total emitted electron current, since the results here are based on the assumption that the electron emission has a cosine angular distribution. That is unlikely to be correct.

08 HYDROGEN↗

Electron Emission from Slightly Oxidized Depleted Uranium Generated by its Own Radioactivity Measured by Electron Spectroscopy, and Electron-Induced Dissociation and Ionization of Hydrogen Near its Surface.

Energy dependent electron emission (counts per second) between zero and 1.4 keV generated by the natural reactivity of uranium was measured by an electrostatic spectrometer with known acceptance angle and acceptance area. The electron intensity decreases continuously with energy, but at different rates in different energy regimes, suggesting that a variety of processes may be involved in producing the observed electron emission. The spectrum was converted to energy dependent electron flux (e-/cm 2 s) using the assumption that the emission has a cosine angular distribution. The flux decreased rapidly from ~10 6 /cm 2 s to ~10 5 /cm 2 s in the energy range from zero to 200 eV, and then more slowly from ~10 5 /cm 2 s to ~3*10 4 /cm 2 s in the range from 200 to 1400 eV. The energy dependent electron mean free path in gases together with literature cross sections for electron induced reactions were used to determine the number of ionization and dissociation reactions per cm 2 s within the inelastic mean free path of electrons, and found to be about 1.3*10 8 /cm 2 s and 1.5*10 7 /cm 2 s, respectively, for hydrogen. An estimate of the number of ionization and dissociation reactions occurring within the total range, rather than the mean free path of electrons in gases resulted in 6.2*10 9 /cm 2 s and 1.3*10 9 /cm 2 s, respectively. The total energy flux carried by electrons from the surface is suspiciously close to the total possible energy generated by one gram of uranium. A likely source of error is the assumption that the electron emission has a cosine distribution. Angular distribution measurements of the electron emission would check that assumption, and actual measurement of the total current emanating from the surface are needed to confirm the value of the current calculated in section II. These results must therefore be used with caution - until they are confirmed by other measurements.

08 HYDROGEN↗

Engine spectrometer probe and method of use

The engine spectrometer probe and method of using the same of the present invention provides a simple engine spectrometer probe which is both lightweight and rugged, allowing an exhaust plume monitoring system to be attached to a vehicle, such as the space shuttle. The engine spectrometer probe can be mounted to limit exposure to the heat and debris of the exhaust plume. The spectrometer probe 50 comprises a housing 52 having an aperture 55 and a fiber optic cable 60 having a fiber optic tip 65. The fiber optic tip 65 has an acceptance angle 87 and is coupled to the aperture 55 so that the acceptance angle 87 intersects the exhaust plume 30. The spectrometer probe can generate a spectrum signal from light in the acceptance angle 506 and the spectrum signal can be provided to a spectrometer 508.

Barkhoudarian, Sarkis↗

Using Rose’s metal alloy as a pinhole collimator material in preclinical small-animal imaging: A Monte Carlo evaluation

Purpose: Pinhole collimation is the most common method of high-resolution preclinical single photon emission computed tomography imaging. The collimators are usually constructed from dense materials with high atomic numbers, such as gold and platinum, which are expensive and not always flexible in the fabrication step. In this work, the authors have investigated the properties of a fusible alloy called Rose’s metal and its potential in pinhole preclinical imaging. When compared to current standard pinhole materials such as gold and platinum, Rose’s metal has a lower density and a relatively low effective atomic number. However, it is inexpensive, has a low melting point, and does not contract when solidifying. Once cast, the piece can be machined with high precision. The aim of this study was to evaluate the imaging properties for Rose’s metal and compare them with those of standard materials. Methods: After validating their Monte Carlo code by comparing its results with published data and the results from analytical calculations, they investigated different pinhole geometries by varying the collimator material, acceptance angle, aperture diameter, and photon incident angle. The penetration-to-scatter and penetration-to-total component ratios, sensitivity, and the spatial resolution were determined for gold, tungsten, and Rose’s metal for two radionuclides, {sup 99}Tc{sup m} and {sup 125}I. Results: The Rose’s metal pinhole-imaging simulations show higher penetration/total and scatter/total ratios. For example, the penetration/total is 50% for gold and 75% for Rose’s metal when simulating {sup 99}Tc{sup m} with a 0.3 mm aperture diameter and a 60° acceptance angle. However, the degradation in spatial resolution remained below 10% relative to the spatial resolution for gold for acceptance angles below 40° and aperture diameters larger than 0.5 mm. Conclusions: Extra penetration and scatter associated with Rose’s metal contribute to degradation in the spatial resolution, but this degradation is not always substantial. The most important factor besides the collimator material was the acceptance angle. This should be kept to a minimum to prevent unnecessary scatter and penetration. For {sup 125}I, the difference in spatial resolution between gold and Rose’s metal is very small, 2.2% in the worst-case scenario. Based on these results, the authors conclude that Rose’s metal is an alternative to standard materials not only for low-energy photon imaging but also for medium-energy applications that require low-cost, flexible pinhole configurations and designs, and that can tolerate a degraded spatial resolution.

07 ISOTOPE AND RADIATION SOURCES↗

Characterization of Pinhole Collimators for High-Resolution Gamma Imaging of Irradiated Fuel

Post-irradiation examination (PIE) of nuclear fuels requires imaging tools capable of resolving isotopic and spatial features with high throughput. This project contributes to a proof-of-concept effort aimed at advancing gamma emission tomography (GET) by evaluating novel fine-aperture pinhole collimators. Two Rose’s metal collimators, 100 µm (20° acceptance angle) and 350 µm (30° acceptance angle), were prototyped and characterized for their effectiveness in transporting gamma rays through the pinhole aperture. To support data collection, a Python-based data acquisition system was developed to coordinate a rotation stage, linear stage, and CZT detector, reducing latency in high-rate gamma event logging to one second per acquisition. Queue-based file writing enabled seamless real-time data capture for count rates up to 35,000 counts per second (cps). List-mode parsing algorithms were implemented to differentiate single and simultaneous gamma interactions for future tomographic reconstruction. Detector response was evaluated in both spectroscopy and list mode acquisition methods across varying source distances to confirm absolute and collimator efficiencies. Preliminary efficiency figures suggest effective collimation of gamma-rays with energies below 700 keV, with ~4% residual intensity through the aperture for Cs-137. The impact of collimator geometry on image quality is currently being evaluated. This groundwork supports the ongoing development of a sub mm resolution cone-beam CT system for imaging fuel phantoms, an essential step toward improving GET efficiency and accelerating nuclear fuel qualification efforts.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Experimental and raytrace results for throat-to-throat compound parabolic concentrators

Compound parabolic concentrators are nonimaging cone-shaped optics with useful angular transmission characteristics. Two cones used throat-to-throat accept radiant flux within one well-defined acceptance angle and redistribute it into another. If the entrance cone is fed with Lambertian flux, the exit cone produces a beam whose half-angle is the exit cone's acceptance angle and whose cross section shows uniform irradiance from near the exit mouth to infinity. (The pair is a beam angle transformer). The design of one pair of cones is discussed, also an experiment to map the irradiance of the emergent beam, and a raytracing program which models the cones fed by Lambertian flux. Experimental results compare favorably with raytrace results.

Leviton, D. B.↗

Sky input horn for a far-infrared interferometer

A unique design has been developed whereby a compound parabolic concentrator (CPC) and a compound elliptical concentrator (CEC) are joined at their throats. The CPC serves as the field-defining optics, in that it accepts up to a certain maximum acceptance angle and then concentrates this accepted energy at its throat. Energy incident from angles greater than the acceptance angle is rejected. The CEC takes the energy concentrated at the CPC throat and then redirects this energy into a finite-sized pupil a given distance away. The considered design will be used as the sky input horn for a cryogenic far-infrared polarizing interferometer to be flown on NASA's Cosmic Background Explorer satellite. The interferometer will operate at 2 K and measure the 3-K cosmic background radiation of the universe in the 100-micrometer-1-cm spectral range.

Miller, M. S.↗

Note: A new angle-resolved proton energy spectrometer

In typical laser-driven proton acceleration experiments Thomson parabola proton spectrometers are used to measure the proton spectra with very small acceptance angle in specific directions. Stacks composed of CR-39 nuclear track detectors, imaging plates, or radiochromic films are used to measure the angular distributions of the proton beams, respectively. In this paper, a new proton spectrometer, which can measure the spectra and angular distributions simultaneously, has been designed. Proton acceleration experiments performed on the Xtreme light III laser system demonstrates that the spectrometer can give angle-resolved spectra with a large acceptance angle. This will be conductive to revealing the acceleration mechanisms, optimization, and applications of laser-driven proton beams.

43 PARTICLE ACCELERATORS↗

Generation of tunable mid-IR radiation by second harmonic in a CdGeAs{sub 2} crystal

Tunable mid-IR radiation is obtained during second harmonic generation of tunable CO{sub 2}-laser radiation using a CdGeAs{sub 2} crystal. Its angular tuning characteristics at the CO{sub 2}- laser wavelength, angular acceptance angle and spectral acceptance are measured. For second harmonic generation at 10.6 {mu}m, the conversion efficiency in the CdGeAs{sub 2} crystal is 90 times higher than that in the ZnGeP{sub 2} crystal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗