Search NASA⌕ Search

SEARCH · Search NASA

Results for “activation temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Alumina Encapsulated Strain Gage Not Mechanically Attached To The Substrate, Used to Temperature Compensate an Active High Temperature Gage In A Half-Bridge Configuration

A temperature compensation element for a high-temperature strain gage and the method of fabricating the same. Preferably, the element is a "dummy" strain gage not mechanically attached to the substrate. The element is encapsulated in an insulative material and used to compensate an active high-temperature strain gage and wired in a half-bridge configuration. The temperature compensation element and high-temperature strain gage are fabricated using the method of the present invention. This method includes temporarily adhering the element to a heat sink, encapsulated in an insulative material and then removed from the heat sink. Next, the element is either stacked or placed near the active gage. Ideally, the element and the active gage have substantially similar heat transfer and electrical properties.

Anthony Piazza↗

Daily rhythms of activity and temperature of Macaca nemestrina

The activity and temperature rhythms of pig-tailed macaques (Macaca nemestrina) maintained in LD 16:8 at 25 C in specially designed restraint chairs have been examined. Activity was monitored via a sensor that was attached to the restraint chair. Temperature was monitored at the axilla, ankle and ear. All variables showed prominent day-night variations, and except for ankle temperature, had highest values during the daytime. These results show that the regulation of the daily rhythm of body temperature involves anatomical sites that are utilized in a temporally distinct fashion.

Sulzman, F. M.↗

Glucose Infusion into Exercising Dogs after Confinement: Rectal and Active Muscle Temperatures

Intravenous glucose infusion into ambulatory dogs results in attenuation of exercise-induced increase of both rectal and thigh muscle temperatures. That glucose (Glu) infusion attenuates excessive increase in body temperature from restricted activity during confinement deconditioning. Intravenous glucose infusion attenuates the rise in exercise core temperature in deconditioned dogs by a yet undefined mechanism.

Greenleaf, J. E.↗

Miniature High-Force, Long-Stroke SMA Linear Actuators

Improved long-stroke shape-memory-alloy (SMA) linear actuators are being developed to exert significantly higher forces and operate at higher activation temperatures than do prior SMA actuators. In these actuators, long linear strokes are achieved through the principle of displacement multiplication, according to which there are multiple stages, each intermediate stage being connected by straight SMA wire segments to the next stage so that relative motions of stages are additive toward the final stage, which is the output stage. Prior SMA actuators typically include polymer housings or shells, steel or aluminum stages, and polymer pads between successive stages of displacement-multiplication assemblies. Typical output forces of prior SMA actuators range from 10 to 20 N, and typical strokes range from 0.5 to 1.5 cm. An important disadvantage of prior SMA wire actuators is relatively low cycle speed, which is related to actuation temperature as follows: The SMA wires in prior SMA actuators are typically made of a durable nickel/titanium alloy that has a shape-memory activation temperature of 80 C. An SMA wire can be heated quickly from below to above its activation temperature to obtain a stroke in one direction, but must then be allowed to cool to somewhat below its activation temperature (typically, less than or equal to 60 C in the case of an activation temperature of 80 C) to obtain a stroke in the opposite direction (return stroke). At typical ambient temperatures, cooling times are of the order of several seconds. Cooling times thus limit cycle speeds. Wires made of SMA alloys having significantly higher activation temperatures [denoted ultra-high-temperature (UHT) SMA alloys] cool to the required lower return-stroke temperatures more rapidly, making it possible to increase cycle speeds. The present development is motivated by a need, in some applications (especially aeronautical and space-flight applications) for SMA actuators that exert higher forces, operate at greater cycle speeds, and have stronger housings that can withstand greater externally applied forces and impacts. The main novel features of the improved SMA actuators are the following: 1) The ends of the wires are anchored in compact crimps made from short steel tubes. Each wire end is inserted in a tube, the tube is flattened between planar jaws to make the tube grip the wire, the tube is compressed to a slight U-cross-section deformation to strengthen the grip, then the crimp is welded onto one of the actuator stages. The pull strength of a typical crimp is about 125 N -- comparable to the strength of the SMA wire and greater than the typical pull strengths of wire-end anchors in prior SMA actuators. Greater pull strength is one of the keys to achievement of higher actuation force; 2) For greater strength and resistance to impacts, housings are milled from aluminum instead of being made from polymers. Each housing is made from two pieces in a clamshell configuration. The pieces are anodized to reduce sliding friction; 3) Stages are made stronger (to bear greater compression loads without excessive flexing) by making them from steel sheets thicker than those used in prior SMA actuators. The stages contain recessed pockets to accommodate the crimps. Recessing the pockets helps to keep overall dimensions as small as possible; and, 4) UHT SMA wires are used to satisfy the higher-speed/higher-temperature requirement.

Cummin, Mark A.↗

Circadian rhythms of temperature and activity in obese and lean Zucker rats

The circadian timing system is important in the regulation of feeding and metabolism, both of which are aberrant in the obese Zucker rat. This study tested the hypothesis that these abnormalities involve a deficit in circadian regulation by examining the circadian rhythms of body temperature and activity in lean and obese Zucker rats exposed to normal light-dark cycles, constant light, and constant dark. Significant deficits in both daily mean and circadian amplitude of temperature and activity were found in obese Zucker female rats relative to lean controls in all lighting conditions. However, the circadian period of obese Zucker rats did not exhibit differences relative to lean controls in either of the constant lighting conditions. These results indicate that although the circadian regulation of temperature and activity in obese Zucker female rats is in fact depressed, obese rats do exhibit normal entrainment and pacemaker functions in the circadian timing system. The results suggest a deficit in the process that generates the amplitude of the circadian rhythm.

Non-NASA Center↗

Temperature structure of active regions deduced from helium-like sulphur lines

Solar active-region temperatures have been determined from the full-Sun spectra of helium-like sulfur (S XV) observed by the Bragg Crystal Spectrometer on Board the Yohkoh satellite. The average temperature deduced from S XV is demonstrated to vary with the solar activity level: A temperature of 2.5 x 10(exp 6) K is derived from the spectra taken during low solar activity, similar to the general corona, while 4 x 10(exp 6) K is obtained during a higher activity phase. For the latter, the high- temperature tail of the differential emission measure of active regions is found most likely due to the superposition of numerous flare-like events (micro/nano-flares).

Watanabe, Tetsuya↗

Individual variation in circadian rhythms of sleep, EEG, temperature, and activity among monkeys - Implications for regulatory mechanisms.

Investigation of circadian rhythms in a number of variables related to sleep, EEG, temperature, and motor activity in rhesus monkeys on an LD 12:12 schedule. Circadian rhythms were found to appear in each of 15 variables investigated. Statistical procedures assessed the variables for evidence of common regulation in these aspects of their circadian rhythms: acrophase (timing), amplitude (extent of change), and level (24-hr mean value). Patterns appearing in the data suggested that the circadian rhythms of certain variables are regulated in common. The circadian modulation of activity in the beta and sigma frequency bands of the EEG was correlated with statistical significance in acrophase, level, and amplitude. The delta frequency band appeared to be under circadian rhythm regulation distinct from that of the other bands. The circadian rhythm of REM stage sleep was like that of beta activity in level and amplitude. The data indicate that REM stage may share some common regulation of circadian timing with both stage 3-4 sleep and with temperature. Generally, however, the circadian rhythm of temperature appeared to bear little relation to the circadian rhythms of motor activity, EEG, or sleep.

Crowley, T. J.↗

Stress versus temperature dependent activation energies in creep

The activation energy for creep at low stresses and elevated temperatures is lattice diffusion, where the rate controlling mechanism for deformation is dislocation climb. At higher stresses and intermediate temperatures, the rate controlling mechanism changes from that of dislocation climb to one of obstacle-controlled dislocation glide. Along with this change, there occurs a change in the activation energy. It is shown that a temperature-dependent Gibbs free energy does a good job of correlating steady-state creep data, while a stress-dependent Gibbs free energy does a less desirable job of correlating the same data. Applications are made to copper and a LiF-22 mol. percent CaF2 hypereutectic salt.

Freed, A. D.↗

High-temperature optically activated GaAs power switching for aircraft digital electronic control

Gallium arsenide high-temperature devices were fabricated and assembled into an optically activated pulse-width-modulated power control for a torque motor typical of the kinds used in jet engine actuators. A bipolar heterojunction phototransistor with gallium aluminum arsenide emitter/window, a gallium arsenide junction field-effect power transistor and a gallium arsenide transient protection diode were designed and fabricated. A high-temperature fiber optic/phototransistor coupling scheme was implemented. The devices assembled into the demonstrator were successfully tested at 250 C, proving the feasibility of actuator-located switching of control power using optical signals transmitted by fibers. Assessments of the efficiency and technical merits were made for extension of this high-temperature technology to local conversion of optical power to electrical power and its control at levels useful for driving actuators. Optical power sources included in the comparisons were an infrared light-emitting diode, an injection laser diode, tungsten-halogen lamps and arc lamps. Optical-to-electrical power conversion was limited to photovoltaics located at the actuator. Impedance matching of the photovoltaic array to the load was considered over the full temperature range, -55 C to 260 C. Loss of photovoltaic efficiency at higher temperatures was taken into account. Serious losses in efficiency are: (1) in the optical source and the cooling which they may require in the assumed 125 C ambient, (2) in the decreased conversion efficiency of the gallium arsenide photovoltaic at 260 C, and (3) in impedance matching. Practical systems require improvements in these areas.

Berak, J. M.↗

A model for gas phase chemistry in interstellar clouds. II - Nonequilibrium effects and effects of temperature and activation energies

The chemical evolution of diffuse and dense interstellar clouds is examined via the time-dependent model outlined by Prasad and Huntress (1980). This paper presents specific results for CH, CO, CH4, O2, CH2O, CN, C2, C2H, HC3N, and NH3. Comparison with observations and predictions of other contemporary models show that cloud temperature plays a very important role through the inverse temperature dependence of radiative association reactions and through activation energies in neutral reactions and selected ion-molecule reactions. The observed fractional abundance of CN with respect to H2 and more accurate recent laboratory data on CN + O and CN + O2 reactions suggest that there is an unidentified, yet efficient, mechanism for conversion of O and O2 into polyatomic species. C2H and HC3N are synthesized early in the history of dense clouds. The value of the fractional abundance of C2H remains high, because as the cloud cools down the activation energy in the C2H + O reaction closes down this most important loss channel. A rapidly decreasing fractional abundance of O with time can also accomplish the same result. The value of the fractional abundance of HC3N remains high because it is an unreactive molecule and probably does not condense readily onto grains.

Prasad, S. S.↗

Thermal and electrical interaction of tantalum with a low temperature chemically active plasma flow

The paper deals with an experimental study of radiative heat transfer and charge transfer processes from the surface of tantalum plates under conditions of unsteady high-temperature heating and oxidation. It is shown that at plate temperatures of 1800 K, the heat flux may be as high as 400 kW/sq m. Heating is shown to stimulate the emissivity of tantalum and the temperature of the free electrons which surface, through a gas boundary layer, from the plasma onto the metal.

Zake, M. V.↗

Active Wireless Temperature Sensors for Aerospace Thermal Protection Systems

Health diagnostics is an area where major improvements have been identified for potential implementation into the design of new reusable launch vehicles in order to reduce life-cycle costs, to increase safety margins, and to improve mission reliability. NASA Ames is leading the effort to advance inspection and health management technologies for thermal protection systems. This paper summarizes a joint project between NASA Ames and Korteks to develop active wireless sensors that can be embedded in the thermal protection system to monitor sub-surface temperature histories. These devices are thermocouples integrated with radio-frequency identification circuitry to enable acquisition and non-contact communication of temperature data through aerospace thermal protection materials. Two generations of prototype sensors are discussed. The advanced prototype collects data from three type-k thermocouples attached to a 2.54-cm square integrated circuit.

Milos, Frank S.↗

How the Emitted Size Distribution and Mixing State of Feldspar Affect Ice Nucleating Particles in a Global Model

The effect of aerosol particles on ice nucleation and, in turn, the formation of ice and mixed phase clouds is recognized as one of the largest sources of uncertainty in climate prediction. We apply an improved dust mineral specific aerosol module in the NASA GISS Earth System ModelE, which takes into account soil aggregates and their fragmentation at emission as well as the emission of large particles. We calculate ice nucleating particle concentrations from K-feldspar abundance for an active site parameterization for a range of activation temperatures and external and internal mixing assumption. We find that the globally averaged INP concentration is reduced by a factor of two to three, compared to a simple assumption on the size distribution of emitted dust minerals. The decrease can amount to a factor of five in some geographical regions. The results vary little between external and internal mixing and different activation temperatures, except for the coldest temperatures. In the sectional size distribution, the size range 24 micrometer contributes the largest INP number.

Perlwitz, Jan P.↗

Mechanical properties testing and results for thermal barrier coatings

Thermal Barrier Coatings (TBC's) provide a significant challenge in the evaluation of their mechanical properties in ways that provide data that is not specimen dependent. The paper reviews various developments of the principal author over the past several years for both plasma sprayed and physical vapor deposited (PVD) materials, as well as new data on the fatigue behavior of one material system. The test methods that have been employed address tensile and compressive modulus and ultimate strength, tensile and compressive fatigue strength, and interfacial strength. This testing is now underway. Property testing is especially difficult for TBC's owing to the limitation on fabrication thickness of the coating. Bending tests are not used as these tests do not provide sufficiently uniform states of strain for property evaluations. Test specimens with uniform states of axial stress have been devised for each material system. The results show that the material property results between various experimenters and experimental methods are not yet consistent. However, the results provide critical design data at a suitable level of accuracy for life prediction. The paper will review both tensile and compressive mechanical testing of uniaxial specimens showing property dependencies on material density and temperatures for both material systems. Successful test results for both tensile and compressive fatigue loadings will be given. The test data shows that the fatigue strength of the TBC's is highly stress dependent in both loading conditions and is likely to depend on stress range and not mean stress. The fatigue strength of the plasma sprayed TBC's appears to increase with elevated temperatures in a range of temperatures below the creep activation temperature for the materials. The plasma sprayed TBC materials have been confirmed to have cyclic hysteresis at all temperature levels down to room temperature. Limited failure analysis data for various specimens suggest that the failure modes are driven by normal geometric discontinuities in the TBC's.

Cruse, T. A.↗

Capillary Limit of a Miniature Loop Heat Pipe with Multiple Evaporators and Multiple Condensers

An experimental investigation of a miniature loop heat pipe with multiple evaporators and multiple condensers were conducted in order to evaluate its capillary limit. The experimental tests were conducted by varying heat load to one or both evaporators, with and without active temperature control of compensation chamber (CC) using the thermoelectric devices, and variable tilts between the evaporators and the CCs. The physical process of the loop and thermal conductance of the heat leak from evaporator to (CC) were discussed based on the test results. The difference of the temperature profiles between with and without active control of CC temperature was evaluated. The effect of the gravity on capillary limit and CC temperature was also evaluated by comparing the test result in horizontal position with that in vertical position. The loop recovery after capillary limit was exceeded was also described.

Ku, Jentung↗

An inductively powered telemetry system for temperature, EKG, and activity monitoring

An implant telemetry system for the simultaneous monitoring of temperature, activity, and EKG from small animals, such as rats, was designed with the feature that instead of a battery the system is energized by an inductive field. A 250 kHz resonant coil surrounds the cage (30 x 30 x 20 cm) and provides the approximately 100 microns of power required to operate the implant transmitter while allowing the animal unrestrained movement in the cage. The implant can also be battery operated if desired. RF transmission is in the 8-10 MHz band, which allows the use of a simple, essentially single IC chip, receiver.

Fryer, T. B.↗