Search NASA⌕ Search

SEARCH · Search NASA

Results for “active bath”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Pathogenesis of sudden death following water immersion (immersion syndrome)

Sympathetic activity under cold stress is investigated. Predominantly vagal cardio-depressive reflexes are discussed besides currently known mechanisms of sudden death after water immersion. Pronounced circulatory centralization in diving animals as well as following exposure in cold water indicates additional sympathetic activity. In cold water baths of 15 C, measurements indicate an increase in plasma catecholamine levels by more than 300 percent. This may lead to cardiac arrhythmias by the following mechanisms: cold water essentially induces sinus bradycardia; brady-and tachycardiarrhythmias may supervene as secondary complications; sinusbradycardia may be enhanced by sympathetic hypertonus. Furthermore, ectopic dysrhythmias are liable to be induced by the strictly sympathetic innervation of the ventricle. Myocardial ischemia following a rise in peripheral blood pressure constitutes another arrhythmogenic factor. Some of these reactions are enhanced by alcohol intoxication.

Buhring, M.↗

Cavitation effects in ultrasonic cleaning baths

In this project, the effect of cavitation from aqueous ultrasonic cleaning on the surfaces of metal and non-metal sample coupons was studied. After twenty cleaning cycles, the mass loss from the aluminum coupons averaged 0.22 mg/sq cm surface area and 0.014 mg/sq cm for both stainless steel and titanium. The aluminum coupons showed visual evidence of minor cavitation erosion in regions of previously existing surface irregularities. The non-metal samples showed some periods of mass gain. These effects are believed to have minor impact on hardware being cleaned, but should be evaluated in the context of specific hardware requirements. Also the ultrasonic activity in the large cleaning baths was found to be unevenly distributed as measured by damage to sheets of aluminum foil. It is therefore recommended that items being cleaned in an ultrasonic bath be moved or conveyed during the cleaning to more evenly distribute the cavitation action provide more uniform cleaning.

Glasscock, Barbara H.↗

Living in Space

In this educational video from the 'Liftoff to Learning' series, astronauts from the STS-56 Mission (Ken Cockrell, Mike Foale, Ellen Ochoa, Steve Oswald, and Ken Cameron) explain and show through demonstrations how microgravity affects the way astronauts live onboard the Space Shuttle, and how these same daily habits or processes differ on Earth. A tour of the Space Shuttle is given, including the sleeping compartments, the kitchen area, the storage compartments, and the Waste Collection System (or WCS, as they call it). Daily habits (brushing teeth, shampooing hair and bathing, eating,...) are explained and actively illustrated, along with reasons of how these applications differ from their employment on Earth.

Ray Brown↗

Using Isothermal Microcalorimetry to Determine Compatibility of Structural Materials with High-Test Hydrogen Peroxide (HTP) Propellant

High-Test Hydrogen Peroxide (HTP) propellant (equal to or greater than 70%) offers many advantages in space launch applications. However, materials used in construction of propulsion systems must be shown to be compatible with HTP. Isothermal Microcalorimetry (IMC) was used to determine the compatibility of several metallic and non-metallic materials with 90% HTP. The results of these experiments agreed with those from immersion bath tests when the values were converted to % Active Oxygen Loss per week (%AOL/wk).

Gostowski, Rudy↗

Using Isothermal Microcalorimetry to Determine Compatibility of Structural Materials with High Test Hydrogen Peroxide (HTP) Propellant

High-Test Hydrogen Peroxide (HTP) propellant (greater than or equal to 70%) offers many advantages in space launch applications; however, materials used in construction of propulsion systems must be shown to be compatible with HTP. Isothermal Microcalorimetry (IMC) was used to determine the compatibility of several metallic and non-metallic materials with 90% HTP. The results of these experiments agreed with those from immersion bath tests when the values were converted to %Active Oxygen Loss per week (%AOL/wk).

Gostowski, Rudy↗

Testing Protocol Proposal to Identify and Evaluate Candidate Materials to Substitute for Silverized Teflon in Thermal Control Applications

Electrostatic discharge (ESD) has been shown to be the primary cause of several glitches in spacecraft operations. It appears that charged particles encountered in the natural environment in certain orbits can collect on the outer surfaces of a spacecraft, building up a charge of several thousand volts. If the potential exceeds the breakdown voltage of the charged material, then an ESD will occur. ESD events involving relatively low voltages, on the order of 100 V, have been shown to damage electronic components. When ESD occurs, electronic and electrical components can be damaged, computer instructions can be garbled, and ablation of material from the spacecraft may occur; degrading both the performance of the thermal control blankets, and the cleanliness of any surfaces on which the detritus becomes deposited. There appear to be six ways to prevent or mitigate the effects of ESD: (1) Choose an orbit where charging is not a problem; (2) Carry extra electromagnetic shielding; (3) Provide redundancy in components and programming; (4) Provide for active dissipation of the charge, by generating a plasma with which to bathe susceptible surfaces; (5) Provide for passive dissipation from a plasma contactors on the susceptible surfaces; and (6) Provide thermal control blankets that do not hold a charge, i.e., that are conductive enough to bleed a charge off harmlessly. These six options are discussed in detail in Losure (1996). Of these six options, number 1 is not always practical, given other requirements of the mission; 2, 3, 4 and 5 will require that extra mass in the form of shielding, etc., be carried by the spacecraft. The most attractive option from a mass and energy point of view seems to be that of finding a material which matches the other performance characteristics of the current thermal control blankets without their tendency to build up an electrostatic charge. The goal of this paper is to describe and justify a testing program which will lead to the approval of materials of this kind.

Losure, Nancy S.↗

Superfluid helium 2 liquid-vapor phase separation: Technology assessment

A literature survey of helium 2 liquid vapor phase separation is presented. Currently, two types of He 2 phase separators are being investigated: porous, sintered metal plugs and the active phase separator. The permeability K(P) shows consistency in porous plug geometric characterization. Both the heat and mass fluxes increase with K(P). Downstream pressure regulation to adjust for varying heat loads and both temperatures is possible. For large dynamic heat loads, the active phase separator shows a maximum heat rejection rate of up to 2 W and bath temperature stability of 0.1 mK. Porous plug phase separation performance should be investigated for application to SIRTF and, in particular, that plugs of from 10 to the minus ninth square centimeters to 10 to the minus eighth square centimeters in conjunction with downstream pressure regulation be studied.

Lee, J. M.↗

Thermal dependence of neural activity in the hamster hippocampal slice preparation

1. Neural activity was recorded in an in vitro hamster hippocampal slice preparation while the temperature of the Ringer's solution bathing in the slice was controlled at selected levels. 2. The amplitude of the population spike (action potentials from a group of pyramidal cells) was measured as bath temperature was lowered from 35 degrees C to temperatures where a response could not be evoked. 3. Plots of population spike amplitude versus temperature have bell-shaped curves. The population spikes increased in amplitude as temperature was lowered from 35 degrees C, reached a peak amplitude between 25 and 20 degrees C, and then decreased until a response could not be evoked when temperature was further lowered. 4. These in vitro results obtained in the slice preparation are related to in vivo hippocampal studies. Results are interpreted as consistent with the proposal reviewed here that neural activity in the hippocampus plays a role at specific stages of entrance into and arousal from hibernation.

Non-NASA Center↗

Cleaning and activation of beryllium-copper electron multiplier dynodes.

Description of a cleaning and activation procedure followed in preparing beryllium-copper dynodes for electron multipliers used in sounding-rocket experiments to detect auroral electrons. The initial degreasing step involved a 5-min bath in trichloroethylene in an ultrasonic cleaner. This was followed by an ultrasonic rinse in methanol and by a two-step acid pickling treatment to remove the oxides. Additional rinsing in water and methanol was followed by activation in a stainless-steel RF induction oven.

Pongratz, M. B.↗

The chemical/physical and microbiological characteristics of typical bath and laundry waste waters

Chemical/physical and microbiological characteristics are studied of typical bath and laundry waters collected during a 12 day test in which the untreated waste waters were reused for toilet flush. Most significant changes were found for ammonia, color, methylene blue active substances, phosphates, sodium, sulfates, total organic carbon, total solids, and turbidity in comparison with tap water baseline. The mean total number of microorganisms detected in the waste waters ranged from 1 million to 10 to the 7th power cells/m1 and the mean number of possible coliforms ranged from 10 to the 5th power to 1 million. An accumulation of particulates and an objectible odor were detected in the tankage used during the 12 day reuse of the untreated waste waters. The combined bath and laundry waste waters from a family of four provided 91 percent of the toilet flush water for the same family.

Hypes, W. D.↗

Evidence that simulated microgravity may alter the vascular nonreceptor tyrosine kinase second messenger pathway

Simulated microgravity (hind limb unweighting; HU) reduces maximal contractile capacity to norepinephrine (NE) but not 5-hydroxytryptamine (5-HT) in the rat abdominal aorta of male Wistar rats. Our earlier study showed that voltage-operated calcium channels, the MAPK pathway [1], and vasoconstrictive prostaglandins contribute to the NE-induced contraction of control (C) but not HU, aorta rings. Genistein, a general tyrosine kinase inhibitor, caused a significant reduction in vascular contractility in C but not HU arteries. The present study explored the role of protein kinase C (PKC) and extracellular receptor-activated kinase 1 and 2 (ERK1/2) in the HU-induced vascular hyporesponsiveness to NE. Microgravity was simulated in Wistar rats by 20 day HU. The abdominal aorta was removed from control and HU rats, cut into 3 mm rings, and mounted in tissue baths to measure isometric contraction. Protein levels were determined using Western blot analysis. PD98059, a selective MAPKK inhibitor, caused a marked inhibition of NE-induced contraction in both C and HU arteries. Calphostin C, a PKC inhibitor, completely abolished the contractile response to NE in both C and HU tissues. Phosphorylated (activated) ERK1/2 protein mass was greater in C, compared to HU, aortas, and was reduced by genistein only in C tissues. MAPK total protein levels in the rat aorta were increased in the HU-treated, compared to C, animals. These results indicate that PKC represents an early transduction step in the contractile response to NE in the rat abdominal aorta. That inhibition of the step immediately before activation of MAPK reduced contraction in both C and HU tissues, while general tyrosine kinase inhibition with genistein blocked only the control responses, suggests that a nonreceptor tyrosine kinase may be involved in HU-induced vascular hyporesponsiveness to NE.

Non-NASA Center↗

Temperature effects on evoked potentials of hippocampal slices from euthermic chipmunks, hamsters and rats

1. Neural activity was recorded in hippocampal slices from euthermic chipmunks, hamsters and rats. 2. While recording the evoked potentials, the temperature of the Ringer's solution bathing the slice was varied by controlling the temperature of an outer chamber jacketing the recording chamber. 3. The temperature just below that at which a population spike could be evoked, Tt, was 10.4 +/- 0.3 degrees C (mean +/- SEM) for chipmunk slices, 14.1 +/- 0.4 degrees C for rat slices and 14.8 +/- 0.4 degrees C for hamster slices. Tt was significantly lower in the chipmunk slices (P<0.01) than in the rat and hamster slices. 4. Data were interpreted as consistent with the hypothesis that chipmunk hippocampal neurons are intrinsically cold resistant.

NASA Discipline Number 40-30↗

Cationic influences upon synaptic transmission at the hair cell-afferent fiber synapse of the frog

The concentrations of inorganic cations (K+, Na+, and Ca2+) bathing the isolated frog labyrinth were varied in order to assess their role in influencing and mediating synaptic transmission at the hair cell-afferent fiber synapse. Experiments employed intracellular recordings of synaptic activity from VIIIth nerve afferents. Recordings were digitized continuously at 50 kHz, and excitatory postsynaptic potentials were detected and parameters quantified by computer algorithms. Particular attention was focused on cationic effects upon excitatory postsynaptic potential frequency of occurrence and excitatory postsynaptic potential amplitude, in order to discriminate between pre- and postsynaptic actions. Because the small size of afferents preclude long term stable recordings, alterations in cationic concentrations were applied transiently and their peak effects on synaptic activity were assessed. Increases in extracellular K+ concentration of a few millimolar produced a large increase in the frequency of occurrence of excitatory postsynaptic potentials with little change in amplitude, indicating that release of transmitter from the hair cell is tightly coupled to its membrane potential. Increasing extracellular Na+ concentration resulted in an increase in excitatory postsynaptic potential amplitude with no significant change in excitatory postsynaptic potential frequency of occurrence, suggesting that the transmitter-gated subsynaptic channel conducts Na+ ions. Decreases in extracellular Ca2+ concentration had little effect upon excitatory postsynaptic potential frequency, but increased excitatory postsynaptic potential frequency and amplitude. These findings suggest that at higher concentrations Ca2+ act presynaptically to prevent transmitter release and postsynaptically to prevent Na+ influx during the generation of the excitatory postsynaptic potential. The influences of these ions on synaptic activity at this synapse are remarkably similar to those reported at the vertebrate neuromuscular junction. The major differences between these two synapses are the neurotransmitters and the higher resting release rate and higher sensitivity of release to increased K+ concentrations of the hair cells over that of motor nerve terminals. These differences reflect the functional roles of the two synapses: the motor nerve terminal response in an all-or-nothing signal consequent from action potential invasion, while the hair cell releases transmitter in a graded fashion, proportionate to the extent of stereocilial deflection. Despite these differences between the two junctions, the similar actions of these elemental cations upon synaptic function at each implies that these ions may participate similarly in the operations of other synapses, independent of the neurotransmitter type.(ABSTRACT TRUNCATED AT 400 WORDS).

NASA Discipline Neuroscience↗

Labor Contractions Enhance Oxygenation and Behavioral Activity of Newborn Rat Pups

Labor contractions help instigate behavioral responses at birth (viz., breathing and suckling) that are vital for the newborn's adaptation to the extrauterine world (Ronca et al., 1996). In the present study, we analyzed the role of labor contractions in postpartum oxygenation and behavioral activity of newborn rat pups. Newborns were observed following either vaginal (V) or cesarean delivery. For cesarean delivery, day 21 pregnant dams' were administered a spinal transaction to eliminate lower body sensation, a laparotomy was performed and the uterus was maintained in a heated (37.5 C) bath. Four rat fetuses in one of the dams' paired uterine horn were compressed (C) to Simulate labor contractions (20 sec/min for 10 min) while four fetuses in the opposite horn were not compressed (NC). Fetuses were surgically removed from the uterus, stroked with a soft brush to mimic postnatal licking by the dam, the umbilical cord occluded. Pups were exposed to room temperature (22 C) for one hr, then nest temperature (33 C) for one hr. PO2, CO2, and O2, saturation were determined at 0, 30, 60, or 120 min post delivery using a blood gas analyzer. V and C delivered neonates showed comparable rates of PO2, CO2 and O2 saturation whereas NC neonates showed depressed levels at all time points (p<0.05). Respiratory rates of V, C and NC neonates increased significantly (p<0.05) over the first two postpartum hrs and did not differ across groups. Postpartum behavioral activity was significantly greater in V and C conditions and positively correlated with postnatal oxygenation. These findings provide further evidence for importance of labor contractions in early postpartum adaptation.

Mills, N. A.↗

Simulated microgravity upregulates an endothelial vasoconstrictor prostaglandin

Endothelial nitric oxide contributes to the vascular hyporesponsiveness to norepinephrine (NE) observed in carotid arteries from rats exposed to simulated microgravity. The goal of the present study was to determine whether a cyclooxygenase product of arachidonic acid also influences vascular responsiveness in this setting. Microgravity was simulated in rats by hindlimb unweighting (HU). After 20 days of HU, carotid arteries were isolated from control and HU-treated rats, and vascular rings were mounted in tissue baths for the measurement of isometric contraction. Two cyclooxygenase inhibitors, indomethacin and ibuprofen, and the selective thromboxane A(2) prostanoid-receptor antagonist, SQ-29548, had no effect on the contraction to NE in control vessels but markedly reduced contraction to NE in HU vessels. When the endothelium was removed, indomethacin no longer had any effect on the NE-induced contraction in HU vessels. In endothelium-intact vessels in the presence of indomethacin, the addition of the nitric oxide synthase inhibitor, N(G)-L-nitro-arginine methyl ester, to the medium bathing HU vessels increased the contraction to NE to the level of that of the control vessels. These results indicate that HU treatment induced two endothelial changes in carotid artery that opposed each other. Nitric oxide activity was increased and was responsible for the vascular hyporesponsiveness to NE. The activity of a vasoconstrictor prostaglandin was also increased, and attenuated the vasodilating effect of nitric oxide.

Non-NASA Center↗

Multichannel electrochemical microbial detection unit

The paper describes the design and capabilities of a compact multichannel electrochemical unit devised to detect and automatically indicate detection time length of bacteria. By connecting this unit to a strip-chart recorder, a permanent record is obtained of the end points and growth curves for each of eight channels. The experimental setup utilizing the multichannel unit consists of a test tube (25 by 150 mm) containing a combination redox electrode plus 18 ml of lauryl tryptose broth and positioned in a 35-C water bath. Leads from the electrodes are connected to the multichannel unit, which in turn is connected to a strip-chart recorder. After addition of 2.0 ml of inoculum to the test tubes, depression of the push-button starter activates the electronics, timer, and indicator light for each channel. The multichannel unit is employed to test tenfold dilutions of various members of the Enterobacteriaceae group, and a typical dose-response curve is presented.

Wilkins, J. R.↗

An Overview of Nuclear Thermal Rocket Element Environmental Simulator (NTREES) Capabilities, Upgrades, and Overlaps in Advanced Material Testing Areas

The Nuclear Thermal Rocket Element Environmental Simulator (NTREES) was designed to perform non-nuclear testing of nuclear thermal rocket (NTR) fuel elements and materials. NTREES can simulate the thermal hydraulic environment within the reactor of an NTR and has been leveraged to provide data on the thermochemical, thermomechanical and thermohydraulic performance of components and materials. Active upgrades to the NTREES facility include installing a DC power supply for DC powered joule heating, a supply gas chiller for a cryogenically cool gas supply, gas pre-heaters with sample holders for testing samples too small to be inductively heated by bathing them in hot gas, and a high temperature digital image correlation (DIC) capability for measuring high temperature strains real time. In addition to NTR testing, given the commonality of high enthalpy flow environments between the reactor of an NTP engine and the aerothermal heating of high-speed flight, the unique capabilities of NTREES to provide high temperature gas flows at high pressure without combustion or electrode spallation byproducts may lend itself to additional usage of the facility beyond the original intent.

Michael P Schoenfeld↗

Linear Actuator Has Long Stroke and High Resolution

The term precision linear actuator, direct drive ( PLADD ) refers to a robust linear actuator designed to be capable of repeatedly performing, over a lifetime of the order of 5 to 10 years, positioning maneuvers that include, variously, submicron increments or slews of the order of a centimeter. The PLADD is capable of both long stroke (120 mm) and high resolution (repeatable increments of 20 nm). Unlike precise linear actuators of prior design, the PLADD contains no gears, levers, or hydraulic converters. The PLADD, now at the prototype stage of development, is intended for original use as a coarse-positioning actuator in a spaceborne interferometer. The PLADD could also be adapted to terrestrial applications in which there are requirements for long stroke and high resolution: potential applications include medical imaging and fabrication of semiconductor devices. The PLADD (see figure) includes a commercially available ball-screw actuator driven directly by a commercially available three-phase brushless DC motor. The ball-screw actuator comprises a spring-preloaded ball nut on a ball screw that is restrained against rotation as described below. The motor is coupled directly (that is, without an intervening gear train) to a drive link that, in turn, is coupled to the ball nut. By eliminating the gear train, the direct-drive design eliminates the complexity, backlash, and potential for misalignment associated with a gear train. To prevent inadvertent movement, there is a brake that includes flexured levers compressed against the drive link by preload springs. This is a power-off brake: There are also piezoelectric stacks that can be activated to oppose the springs and push the levers away from the drive link. Hence, power must be applied to the piezoelectric stacks to release the drive link from braking. To help ensure long operational life, all of the mechanical drive components are immersed in an oil bath within hermetically sealed bellows. The outer end of the bellows holds the outer end of the ball screw, thereby preventing rotation of the ball screw. Positioning is controlled by an electronic control system that includes digital and analog subsystems that interact with the motor and brake and with two sensor/encoder units: a Hall-effect-sensor rotation encoder and a linear glass-scale encoder. This system implements a proportional + integral + derivative control algorithm that results in variation of voltage commands to each of the three pairs of windings of the brushless DC motor. In one of two alternative control modes, the voltages are applied to the windings in a trapezoidal commutation scheme on the basis of timing signals obtained from the Hall-effect sensors; this scheme yields relatively coarse positioning - 24 steps per motor revolution. The second control mode involves a sinusoidal commutation scheme in which the output of the linear glass-scale encoder is transposed to rotational increments to yield much finer position feedback - more than 400,000 steps per revolution.

Cook, Brant T.↗