Search NASA⌕ Search

SEARCH · Search NASA

Results for “active current limiting control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Active Fault Current Limiting Control for Half-Bridge MMC in HVDC Systems

DC faults of MMC can result in a significantly large fault current due to the discharge of submodule capacitors. The fault current not only risks damaging the MMC but also demands a considerable breaking capacity from the dc circuit breaker (DCCBs). This paper introduces two novel active fault current limiting methods (AFCLs), namely virtual impedance-based and energy control-based AFCL. The first method utilizes circulating current feedforward, which introduces a virtual arm impedance to suppress the rate of rise of the fault current. Meanwhile, the second method relies on the control of the internally stored energy of the MMC to automatically minimize the number of submodules that discharge during a dc-side fault. Therefore, both the dc-side current and the MMC arm current can be effectively suppressed after the occurrence of the fault. The proposed methods do not require fault detection and their response is proportional to the rate of rise in the fault current. Simulation case studies are presented to demonstrate the proposed methods.

active current limiting control↗

A Two-Stage Current Limiting Control Strategy for Direct-Droop-Controlled Grid-Forming Inverters

This paper presents a two-stage current limiting control strategy with fault ride-through capability for the direct-droop-controlled grid-forming (GFM) inverters. The proposed approach comprises Stage 1 and Stage 2 current limiting controls. During faults, Stage 1 current limiting control instantly clamps the inverter output current magnitude to its maximum transient limit by blocking the switching pulses to the insulated-gate bipolar transistors (IGBTs) with the help of a hysteresis loop control, and Stage 2 current limiting control limits the inverter output current magnitude to its steady-state limit by regulating the amplitude and frequency of the modulating waveform utilizing the active and reactive current limiting control loops. By implementing the current limiting actions in two stages, this approach can effectively limit the over-current within a few cycles after the fault occurrence and ensure synchronism to the grid after long-term fault events. The efficacy of the proposed control approach is validated through electromagnetic transient (EMT) simulation results conducted on a single GFM inverter-based test system and the IEEE 39-bus test system with multiple GFM inverters in the PSCAD platform.

Mohiuddin, Sheik Mohammad↗

Positive-Sequence Modeling of Droop-Controlled Grid-Forming Inverters for Transient Stability Simulation of Transmission Systems

Here, this paper describes a positive-sequence model to represent two widely reported droop-controlled grid-forming inverters for bulk power systems simulation study. Methods of how to develop the equivalent voltage source behind impedance to represent inverters with and without inner control loops, modeling of P-f and Q-V droop controls, active and reactive power limiting modeling, and modeling of fault current limiting controls are described in detail. The model is implemented in commercially available positive-sequence simulation tools and compared with detailed electromagnetic transient models in both a single-grid-forming-inverter infinite-bus system and a modified IEEE 39-bus system. Finally, the model is tested on the full US Western Electricity Coordinating Council (WECC) system. Study results show that the model has a good level of accuracy compared to the detailed EMT models, and at the same time also achieves a high computational efficiency, which is suitable for the bulk power system simulation study.

42 ENGINEERING↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems: Preprint

For the development of multi-terminal high voltage DC (MTDC) transmission, it is critical to design the protection system that can selectively isolate the faulty area from the healthy part of the dc grid using DC circuit breakers (DCCBs) while ensuring continuous operation of converter stations in the healthy part. However, because of the lack of fault current blocking capability in half-bridge (HB) modular multilevel converters (MMCs), when a dc fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of MMCs in the healthy part. Large DC reactors are often considered in series with DCCBs to reduce the rate of rise of fault currents and prevent blocking of MMCs in the healthy part of the grid. However, large DC reactors can prohibitively increase the cost of the system, particularly when they are considered in an offshore environment, for instance in offshore wind projects. Large dc reactors can also introduce stability issues and create post-fault oscillations. This paper presents an adaptive fault current limiting control method for MMCs to avoid their blocking and enable continuous operation of MTDC systems. It contains two parts: The first part is based on circulating current feedforward control that emulates virtual reactors in each arm of an MMC, which is immediately activated when the fault current starts to increase, to reduce the rate of rise of the fault current; the second part is triggered when the fault current exceeds a preset threshold by temporarily bypassing the SMs, serving as a complement to the fault current limiting effect of the first part. Both parts do not require fault detection signal and they are activated automatically during faults. Simulation case studies of a four-terminal bipolar MMC-HVDC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems

A crucial requirement of the protection system for multi-terminal high-voltage DC (MTDC) transmission is that it is capable of selectively isolating the faulty area from the healthy part of the network using DC circuit breakers (DCCBs), while ensuring continuous operation of converter stations in the healthy part of the network. But in the half-bridge modular multilevel converters (HB-MMCs) based MTDC system, since HB-MMCs do not have fault current absorption capability, when a DC fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of the MMCs in the healthy part. To facilitate fault-ride-through capability of MTDC system, large DC reactors are often considered in series with DCCBs to reduce the rate of rise of the fault current and prevent blocking the MMCs in the healthy part of the DC networks; however, large DC reactors prohibitively increase the cost of the system, introduce stability issues and can create post-fault oscillations. This paper presents an adaptive fault current-limiting control method for MMCs to avoid their blocking and enable the continuous operation of the healthy part of MTDC systems. The method contains two parts: The first part is based on circulating current feedforward control, which emulates virtual reactors in each arm of an MMC, and is immediately activated when the fault current starts to increase to reduce the rate of rise of the fault current. The second part temporarily bypasses all the submodules when the fault current exceeds a preset threshold, complementing the fault current-limiting effect of the first part. Neither part requires fault detection signals, and they are automatically activated during faults. Simulation case studies of a four-terminal bipolar MMC-based high-voltage DC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

A Novel Two Stage Collimation Unit for Fermilab Booster

A new two-stage collimation unit (2SC) for Fermilab Booster will be installed during 2024 summer shutdown. It is a supplementary collimator for existing single stage Booster collimators. Design details of this 2SC adapted to Booster conditions are described. Results of beam dynamics simulations on collimation efficiency and evaluation of collimator shielding with MARS code on this new system are presented. The analysis on beam dynamics shows that the system will help to collimate up to about 1% of the beam in a confined way and, prompt and residual activation meet Fermilab Radiological Control limits in current as well as during PIP-II era high intensity operation of the Booster.

43 PARTICLE ACCELERATORS↗

DC Circuit Breakers: A Technology Development Status Survey

DC circuit breakers (DCCBs) play a significant role in obtaining the reliability and stability of DC power systems. Selective and fast isolating of faults minimizes the power supply outages to end electricity users and protects the power converters implemented in the DC system. During the last decades, DCCBs have been deeply investigated in industry and academia. There has been impressive progress in terms of efficiency, response time, power-density, lifetime, and electrical operating ratings. Introducing wide bandgap (WBG) devices further has motivated researchers to propose more efficient and novel topologies. This paper provides a point of reference and a background review for DCCBs from novel aspects, fulfilling absent parts in the literature. The elaborated subjects include current commutation circuitry, DCCBs trip-curves developments, newly added functions to DCCBs, as well as marketing analysis. The advancements of DCCBs are surveyed and development needs are recognized. This paper aims to identify the future research needs of DCCBs for emerging DC power systems.

42 ENGINEERING↗

Grid Forming Control of PMSG-based Wind Turbines under Fault Conditions

Grid-forming control is widely envisioned as core technology ensuring stable operation of future power systems with increasing deployment of converter-interfaced renewable generation. However, research on grid forming control of wind turbines, especially under faults, is still in its early stages. In this context, this paper augments dual-port grid-forming control for type IV wind turbines with auxiliary controls to enable reliable fault ride through capabilities. In particular, the proposed control does not require a dc chopper or mode switching to grid-following control. Instead, energy-balancing dual-port GFM control is augmented with active rotor speed damping control and threshold virtual impedance for current limiting during faults. Different operating conditions of wind turbines are considered in a detailed electromagnetic transient simulation study to validate the effectiveness of the proposed control.

Lyu, Xue↗

Enhanced Large-Signal Stability Method for Grid-Forming Inverters During Current Limiting: Preprint

Grid-forming (GFM) inverters are a promising technology for the widespread integration of renewable energy sources in future power systems. As a key element of GFM inverter control, the primary controller governs the internal reference voltage and angle. During contingencies in the grid---such as faults, voltage drops, or frequency and phase jumps---an inverter can be forced into a current-limiting mode of operation modulating inverter dynamics, and, as a result, it is prone to losing synchronism with the grid. In this paper, we propose a novel GFM primary control method with an additional synchronization term that naturally activates during contingencies to improve the dynamic response. The method allows the inverter to remain synchronized with the grid, which improves the inverter's dynamic behavior both during and after current-limiting grid conditions and enhances grid support, including voltage support using full current capacity. The method is demonstrated for voltage, frequency, and phase jumps both in a single-machine-to-infinite-bus and a network-wide electromagnetic transient simulation of the IEEE 14-bus system with 5 GFM inverters. The simulations provide insights into the proposed synchronization method and confirm the high potential of the method, which robustly secures synchronism under severe contingencies.

current limiting↗

Transport Processes in a Li-ion Cell during an Internal Short-Circuit

Internal short-circuit in a lithium-ion cell causes an abrupt increase in cell temperature and triggers subsequent thermal runaway. In this work, we present a detailed electrochemical-thermal model to investigate the physical behavior during an internal short-circuit. Simulations at wide range of heat transfer coefficients and short-circuit resistances are conducted to illustrate electrochemical and thermal behavior under a wide range of conditions. The Joule heating at the shorted region promotes electrochemical reactions nearby, causing in-plane non-uniformity of electrolyte and active material transport. Furthermore, it is found that diffusion in solid active materials plays a significant role at very high shorting currents (~20 C), as electrochemical reactions rate are being controlled progressively more by availability of Li + at the interface, due to limitations in diffusion through the active material with increasing discharge rates. This diffusion limitation causes a drop in available energy, and subsequently a decrease in cell equilibrium potential and the heat generation rate at the location of the short. On the other hand, rapid depletion of lithium concentration in the electrolyte and accumulation on the electrode surface results in highly non-uniform transport properties resulting in higher heat generation rates. Hence, the heating regime shifts from "local heating" to "global heating". Based on the findings, important design parameters for battery safety are discussed.

25 ENERGY STORAGE↗

Quench protection for high-temperature superconductor cables using active control of current distribution

Superconducting magnets of future fusion reactors are expected to rely on composite high-temperature superconductor (HTS) cable conductors. In presently used HTS cables, current sharing between components is limited due to poorly defined contact resistances between superconducting tapes or by design. The interplay between contact and termination resistances is the defining factor for power dissipation in these cables and ultimately defines their safe operational margins. However, the current distribution between components along the composite conductor and inside its terminations is a priori unknown, and presently, no means are available to actively tune current flow distribution in real-time to improve margins of quench protection. Also, the lack of ability to electrically probe individual components makes it impossible to identify conductor damage locations within the cable. In this work, we address both problems by introducing active current control of current distribution between components using cryogenically operated metal-oxide-semiconductor-field-effect transistors (MOSFETs). We demonstrate through simulation and experiments how real-time current controls can help to drastically reduce heat dissipation in a developing hot spot in a two-conductor model system and help identify critical current degradation of individual cable components. Finally, prospects of other potential uses of MOSFET devices for improved voltage detection, AC loss-driven active quench protection, and remnant magnetization reduction in HTS magnets are also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Enabling Grid-Forming Control with Fault Ride-Through in Unbalanced Distribution Networks

Distribution networks are often unbalanced, causing oscillatory responses in inverter control designed for balanced conditions. Here, to address this problem, this paper proposes a novel time-domain transformation appropriate for inverter control and enables the decomposition of three-phase unbalanced signals into constant positive and negative components. Relations useful for calculating unbalanced active and reactive power are derived from first principle, providing insight into vector products of unbalanced three-phase signals. Furthermore, a grid-forming control effective under unbalanced conditions is developed, which delivers superior performance while meeting UNIFI1 specifications for grid-forming control under unbalanced conditions. specifications applicable to category 4 inverter-based resource, like setting and regulating frequency/voltage, providing voltage support, sharing active power, injecting negative sequence current, and riding through faults. A current limiter is proposed for safe fault ride-through and integrates with the grid-forming control featuring frequency/voltage droop controllers and current and voltage control loops. The transformation of interconnected inverters is formulated and stability of the proposed control analyzed to support robust parameter selections. The effectiveness of the proposed transformation and grid-forming control is demonstrated through analytical results and real-time simulation of a IEEE 123 distribution network on the Real-Time Digital Simulator. Comparison with existing methods shows that the proposed strategy satisfies the UNIFI specifications with a much better performance.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Modeling active control of resistive wall mode with power saturation and sensor noise on HL-2M

The resistive wall mode (RWM) control on the HL-2M tokamak is simulated with the MARS-F code (Liu et al 2000 Phys. Plasmas 7 3681), aiming at quantifying control current and voltage requirements when more realistic issues are taken into account, i.e. the control power saturation and the sensor signal noise. The fluid model predicts a narrow stability region for the n = 1 RWM without magnetic feedback, in the 2D parameter space of the plasma pressure versus the toroidal flow speed. Magnetic feedback can fully stabilize the RWM on HL-2M. Without considering the voltage limitation and the sensor signal noise, it is found that plasma flow helps active control of the mode, by reducing the required critical feedback gain for both flux-to-current and flux-to-voltage control schemes. In the absence of the sensor signal noise, the lowest control voltage saturation level, below which the RWM control is lost, is found to roughly satisfy a linear relation to the plasma flow frequency, indicating that subsonic plasma flow is effective in relaxing the control power requirement for the RWM feedback stabilization. The presence of the sensor signal noise substantially modifies the feedback results. A statistical study finds that the sensor signal noise, with the standard deviation of 0.1 G on HL-2M, roughly doubles the required control voltage for successful mode control. The synergistic stabilization effect due to plasma flow is somewhat weakened by the presence of the sensor signal noise. At a given rotation, the tolerable voltage limit generally increases with increasing feedback gain due to the sensor signal noise.

Physics↗

Atomic-scale Imaging of PGM-free Catalyst Active Sites by 30 keV 4D-STEM

Platinum group metal (PGM)-free catalysts have attracted a large amount of attention due to their potential for enabling low-cost, commercially viable hydrogen fuel cells and electrolyzers [1]. Degradation of cell performance remains a significant challenge, however, currently limiting implementation of devices that utilize PGM-free materials [2]. Controlling degradation in these materials requires a better understanding of the atomic structure of active sites, thought to be FeN4 structures within a graphitic carbon lattice, which would enable more accurate prediction of the associated degradation pathways. The exact structural arrangement of active sites in these materials is still debated since a range of structures have been computationally predicted and methods to directly validate these models are still needed [1,3-5].While scanning transmission electron microscopy (STEM) has provided initial glimpses into the nature of the proposed active sites, detailed evaluation of the structure of these sites is challenging since they involve defects, edges, and nitrogen dopants in the graphitic lattice, which are susceptible to beam damage [6,7]. Conventional STEM imaging and spectroscopy methods exacerbate this problem with dose-inefficiency or nonideal contrast characteristics for imaging light and heavy elements simultaneously. A method that minimizes damage while generating dose-efficient, easily-interpretable contrast for both light and heavy elements is therefore needed to facilitate imaging of sensitive active site atomic structure.Here, we demonstrate direct atomic-scale imaging of PGM-free catalyst active sites by low-voltage four-dimensional (4D)-STEM. To accomplish this, we pair a 30 keV aberration-corrected probe, which minimizes knock-on damage, with a fast pixelated detector that has optimal performance at low beam energies [8]. We show how this setup enables relatively simple center-of-mass (CoM) techniques [9,10] to produce images with an increased signal-to-noise ratio (SNR) and light-element contrast over conventional imaging modes, allowing the entire active site structure to be imaged at the atomic scale. Moreover, we show how electron ptychography [11,12] enables images with further improved characteristics to be obtained, for example by minimizing residual aberrations, which provides a more accurate structural representation. The increased understanding that these low-voltage 4D-STEM techniques will provide about the atomic structure of PGM-free active sites and their associated degradation pathways will facilitate rational design of next-generation materials, promoting development of low-cost hydrogen fuel cells, electrolyzers, and other energy conversion devices [13]. References:[1] U Martinez et al., Adv. Mater. 31 (2019), p. 1806545.[2] Y Shao et al., Adv. Mater. 31 (2019), p. 1807615.[3] J Kneebone et al., J. Phys. Chem. C 121, (2017), p.16283.[4] T Mineva et al., ACS Catal. 9 (2019), p. 9359.[5] J Li et al., Nat. Catal. 4 (2021), p. 10.[6] T Susi et al., ACS Nano 6 (2012), p. 8837.[7] P Zelenay and DJ Myers, US Department of Energy Hydrogen and Fuel Cells Program 2017 Annual Merit Review and Peer Evaluation Meeting, Washington, DC (2017).[8] H Ryll et al., J. Inst. 11 (2016), p. P04006.[9] K Müller et al., Nat. Commun. 5 (2014), p. 5653.[10] I Lazic et al., Ultramicroscopy 160 (2016), p. 265.[11] H Yang et al., Nat. Commun. 7 (2016), p. 12532.[12] Y Jiang et al., Nature 559 (2018), p. 343. [13] Research sponsored by the Hydrogen and Fuel Cell Technologies Office, Office of Energy Efficiency and Renewable Energy, US Department of Energy (DOE). Research was conducted at the Center for Nanophase Materials Sciences, which is a DOE Office of Science User Facility.

Zachman, Michael↗

T-Type Modular DC Circuit Breaker (T-Breaker) for Future DC Networks

The developed T-Type Modular DC Circuit Breaker (T-Breaker) technology offers an all-in-one solution to challenges in DC networks. This includes swift fault detection and protection, power transient stability, and power quality improvement, achieved through the utilization of wide bandgap (WBG) power semiconductors and energy storage devices. The T-Breaker not only facilitates rapid fault current detection and interruption but also implements fault current limiting through active insertion of storage devices or by operating WBG devices in the saturation region. Additionally, with the assistance of energy storage devices, potential overvoltage issues on power devices induced by control signal misalignment can be mitigated. The T-Breaker can be regulated to perform shunt current injection/absorption using the vertical arm and series voltage insertion via the horizontal arm, thereby enhancing DC system stability during voltage or load power fluctuation transients. The OSU team and Raytheon team actively worked together on designing, fabricating, assembling, and testing of two T-Breaker prototypes. The first prototype is rated at 1 kV, 500 A with half-bridge (unipolar) structure to validate the T-Breaker concept. The second prototype is rated at 20 kV, 50 A with full-bridge (bipolar) topology which can reach an efficiency of 99.977%, realize a power density of 60.2 MW/m3, and eliminate the 500-A fault current with a fault response time of around 20 µs. The prototypes show great feasibility of adopting this technology in multiple applications including electrified aircraft, super charging stations, data centers, etc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Duty-Cycle Predictive Control of Quasi-Z-Source Modular Cascaded Converter Based Photovoltaic Power System

A duty-cycle predictive control is proposed for dc grid integration of front-end isolated quasi-Z-source modular cascaded converter (qZS-MCC) photovoltaic (PV) power system. The post-stage qZS half-bridge dc-dc converter deals with PV maximum power point tracking, dc grid integration, and dc-link voltage balance; whereas, the front-end isolation converters operate at a constant duty cycle of 50%. Thus, it saves control hardware resources while overcoming challenges from PV-panel voltage variations and dc-bus voltage limit. The proposed control uses the derived circuit model to predict the global active-state duty cycle for grid-connected current control and predict the shoot-through duty cycles for dc-link voltage balance, achieving a fast and accurate tracking target. The proposed control method has advantages of: i) eliminating weighting factors that exist in conventional model predictive control (MPC), ii) no sophisticated loop parameters design that exists in proportional-integral (PI) control, iii) operating at constant switching frequency that is different from the conventional MPC with variable switching frequency. Simulation and experimental tests are carried out to verify the effectiveness of the proposed control method and compare with the PI-based control system.

42 ENGINEERING↗

Triggering the stringent response enhances synthetic methanol utilization in Escherichia coli

Synthetic methylotrophy aims to engineer methane and methanol utilization pathways in platform hosts like Escherichia coli for industrial bioprocessing of natural gas and biogas. While recent attempts to engineer synthetic methylotrophs have proved successful, autonomous methylotrophy, i.e. the ability to utilize methane or methanol as sole carbon and energy substrates, has not yet been realized. Here in this paper, we address an important limitation of autonomous methylotrophy in E. coli: the inability of the organism to synthesize several amino acids when grown on methanol. By activating the stringent/stress response via ppGpp overproduction, or DksA and RpoS overexpression, we demonstrate improved biosynthesis of proteinogenic amino acids via endogenous upregulation of amino acid synthesis pathway genes. Thus, we were able to achieve biosynthesis of several limiting amino acids from methanol-derived carbon, in contrast to the control methylotrophic E. coli strain. This study addresses a key limitation currently preventing autonomous methylotrophy in E. coli and possibly other synthetic methylotrophs and provides insight as to how this limitation can be alleviated via stringent/stress response activation.

60 APPLIED LIFE SCIENCES↗