Search NASA⌕ Search

SEARCH · Search NASA

Results for “activity measurement system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Secure State Estimation with Asynchronous Measurements for Coordinated Cyber Attack Detection in Active Distribution Systems

Coordinated cyber attacks tamper with measurement data to disrupt the situational awareness of active distribution systems. Various sensors report measurements asynchronously at different rates, which introduces challenges during state estimation. In addition, this forces cyber intruders to exert greater effort to compromise multiple communication channels and launch coordinated attacks. Therefore, multi-channel and asynchronous measurements could be harnessed to develop more secure cyber defense strategies. In this paper, a prediction-correction-based multi-rate observer is designed to exploit the value of asynchronous measurements for the detection of coordinated false data injection (FDI) attacks. First, a time-function-dependent prediction-correction strategy is proposed to adjust the sampling interval for each sensor’s measurement. Then, an observer is designed based on the trade-off between estimation error and the optimal period of the most recent sampling instant, with the convergence of estimation error with the maximum permitted sampling interval. Moreover, the conditions for exponential stability are developed using the Lyapunov–Krasovskii functional technique. Next, a coordinated FDI attack detection strategy is developed based on the dual nonlinear minimization problem. The proposed attack detection and secure state estimation strategies are tested on the IEEE 13-node system. Simulation results show that these schemes are effective in enhancing attack detection based on asynchronous measurements or compromised data.

asynchronous measurements↗

A Graph Convolutional Network for Active Distribution System Anomaly Detection Considering Measurement Spatial-Temporal Correlations

The accuracy of distribution system state estimation may be significantly impacted by the existence of bad measure-ments and unexpected topology errors. This paper proposes a data-driven Graph Convolutional Network (GCN) for anomaly detection, including bad measurements and topology change events. Compared to many existing machine learning approaches, the proposed approach embeds both spatial-temporal measure-ment correlations, which allows us to detect and distinguish different anomalies. Numerical results carried out on the IEEE 37-node system demonstrate that the proposed-based method can obtain high accuracy in detecting bad data and topology changes as compared to other approaches, even in the presence of high PV penetrations.

active distribution system↗

Utilizing Advanced Statistics to Determine Anomalistic Conditions in Pebble-Bed Reactors

Pebble-bed reactors (PBRs) utilize hundreds of thousands of fuel pebbles, which continuously circulate through the core, in lieu of traditional fuel assemblies to generate fissions and produce power. The use of unmarked fuel pebbles presents a challenge for international safeguards verification that nuclear material is not being diverted. To ensure pebble diversion is not taking place, new methods for accounting for and monitoring the pebbles should be examined to determine an appropriate methodology for performing bulk accountancy with pebbles. Here, this work examines the use of statistical methods for determining if the reactor is within a declared range of operation by examining the statistical distribution of pebble burnup as they are discharged from the core. Using this methodology, we created a model that detects diversion over 95% of the time, over multiple diversion pathways, if the reactor core maintains a constant power density during the diversion process and only falsely labels a diversion case nominal 2% of the time. For a diversion scenario where the reactor is maintained at a constant power, the statistical analysis can correctly identify if diversion is occurring over 80% of the time; however, nearly 20% of specific diversion pathways are mislabeled nominal. These results provide a basis and framework for exploring the further use of statistical methods to determine where these methods could be most useful and where additional methods, such as machine learning, could be used to capture if diversion is occurring in pebble-bed reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Online Alpha Monitoring of High Cs-137 Hanford and SRS High Level Waste with Tensioned Metastable Fluid Detectors

The Department of Energy’s Hanford and Savannah River Sites maintain millions of gallons of caustic supernate and salt high activity waste in their high-level waste (HLW) tank farm inventories. The Savannah River Site is currently treating this waste with a calixarene-based solvent extraction of Cs-137 to reduce these inventories. Hanford is employing an at-tank crystalline silico titanate (CST) based solid phase extraction methodology to reduce their liquid HLW inventories. Due to the high solubility of Cs-137 and the relative insolubility of the actinides in these caustic waste forms, the beta to alpha radioactivity ratio can often exceed six orders of magnitude in the feed solutions to these treatment processes. This unique characteristic leads to significant technical challenges in making rapid gross alpha measurements in the presence of the overwhelming beta, gamma, as well as dissolved sodium salt in these HLW matrices. Conventional radioanalytical techniques, such as liquid scintillation analysis or gas flow proportional counting require significant radiochemistry preparation prior to the radiometric measurements for gross alpha activity. These required pretreatments render these technologies untenable for rapid quantification of gross alpha activity that could be required to support on or at-line measurements ensuring a waste stream will meet regulatory requirements. The radiation measurement properties of Tensioned Metastable Fluid Detectors (TMFDs) have been studied by Purdue University’s Taleyarkhan research group for well over a decade. Fluids tensioned to the appropriate degree will rupture when struck by radiation, resulting in a measurable cavitation event. The negative pressure generating this tension can be adjusted by centrifugal rotation or by acoustic means in such a way that these cavitation events can be generated from alpha radiation but will not be generated by beta or gamma radiation. Purdue University and the Savannah River National Laboratory are currently collaborating to develop a gamma/beta blind, spectroscopic alpha measurement system based on the Tensioned Metastable Fluid Detector technology to provide a potential solution for performing rapid gross alpha measurements on these high gamma/beta sample matrices. Measurements using the Indirect Drive Acoustically Tensioned Metastable Fluid Detectors developed as part of this collaboration were performed with an alpha emitting radionuclide. Successful determination of gross alpha activity was observed, indicating a potential pathway for rapid gross alpha measurements in remote-handled shielded cells or in process situations requiring online alpha monitoring. Measurements using this system have been conducted on high beta activity solutions, demonstrating the beta blind capability of this system. Measurements are currently underway to test the system’s capability to measure gross alpha activity on Savannah River Site high level waste high Cs-137 samples that have been measured by the SRNL radiochemistry team. This work was supported by the DOE EM Technology Development program.

DiPrete, David [Savannah River National Laboratory↗

Advanced Measurements for Resilient Integration of Inverter-Based Resources: PROGRESS MATRIX Final Report

As nearly every aspect of the electric power grid undergoes rapid change, measurement technologies that support grid operation and planning must evolve as well. The rapid large-scale deployment of inverter-based resources (IBRs) vital to achieving the nation’s clean energy goals has in some cases led to negative impacts on the reliability and security of the bulk power system (BPS). Advanced power system measurements, including synchronized phasor and waveform measurements, are key to making IBR integration secure and reliable. To this end, the Department of Energy (DOE) initiated the PROGRESS MATRIX project to develop advanced measurement capabilities and analytics that will accelerate adoption of IBRs while improving the reliability and resilience of the BPS. This report discusses the outcomes of the project, which was a joint effort between the Pacific Northwest National Laboratory (PNNL), Oak Ridge National Laboratory (ORNL), the National Renewable Energy Laboratory (NREL), and Lawrence Berkeley National Laboratory (LBNL). In the project’s first year, PNNL, NREL, and ORNL partnered with the Bonneville Power Administration (BPA), the Western Area Power Administration (WAPA), and Kauai Island Utility Cooperative (KIUC) to understand their existing measurement capabilities and the gaps limiting deployment of IBR-focused measurement systems and analytics. The other primary activity in the first year was deployment of GridSweep instruments, which provide unprecedented precision in waveform measurement while probing distribution systems. The instruments were deployed at Dominion Energy and the University of California, Riverside. In the project’s second year, the input from partner utilities and collected measurements were used to advance measurement capabilities. Twelve analytical methods spanning disturbance analysis, power plant evaluation, feeder evaluation, and modeling were developed. Two software tools were developed, one to analyze GridSweep measurements and another to automatically evaluate the control performance of power plants connected to the BPS. Testbeds at ORNL and NREL were augmented to better enable studies of IBR integration. The project culminated in demonstrations of these analytical methods, software tools, and testbeds, both in the field and in the laboratory. This report discusses these various accomplishments and documents the significant progress in developing advanced measurement capabilities to support the secure, reliable, and accelerated adoption of IBRs in the BPS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Membrane Composition Influences Expression Yield of Plant Cytochrome P450s in E. coli Lysate-Based Cell-Free Systems

Plant cytochrome P450 enzymes are central to natural product biosynthesis, but remain difficult to express in microbial hosts due to their transmembrane nature. Lysate-based, cell-free expression systems allow supplementation with artificial membranes to support the expression and translocation of transmembrane proteins. We developed a framework to systematically test liposomal membrane compositions to enhance the plant P450 expression yield. Adjustments to common phospholipid ratios or the addition of plant galactolipids had minimal impact on expression. In contrast, blended liposomes containing Egg PC, sterol-conjugated phospholipids, and PEGylated lipids produced concentration-dependent increases in expression. Expression of an Escherichia coli mechanosensitive channel and three plant P450s improved more than 2-fold, with some P450s showing up to 14-fold enhancement. Furthermore, these findings highlight membrane composition as a key determinant of the P450 expression yield in cell-free expression systems. While P450 activity was not measured, these findings provide a framework for future workflows toward achieving functional plant transmembrane enzymes for the bioproduction of natural products.

TXTL↗

FY25 Mid-Year Report: FNCL Enhancements Implementation

During the first half of FY25 the FNCL team has made consistent progress toward the completion of our project goals. The FNCL prototype panel design has been successfully applied to a fully instrumented 3-panel system which is actively under construction. The FNCL Demonstrator System contains solid scintillators instrumented with SiPMs, which operate on an updated CAEN digitizer, requires no high-voltage, and has a smaller overall footprint. The onboard software will include the LLNL-developed GMM-PSD signal processing. Later this year the system will be experimentally tested alongside the baseline FNCL instrument at LLNLs ISSA facility. In addition to a full systems test, the performance of a DD generator for active interrogation measurements compared to the standard AmLi source will be established for both systems. The data collected at the ISSA facility will be used to experimentally validate the FNCL-Fast Isotopic Fuel Assay’s (FIFA) capability to measure U-235 loading and to predict gadolinium poison content with passive interrogation. The FNCL-FIFA modal was benchmarked with simulation-based data and a user-friendly GUI was added earlier this year. Three separate codes have been submitted to the LLNL ESW system for review prior to their transfers. These include the Predictive Modeling Response toolkit, GMM-PSD firmware beta version, and the FNCL-FIFA analysis package with GUI and user documentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of 127 Xe tracer measurements using a net counts method

A suite of measurement systems were deployed as part of the Physical Experiment 1 series of experiments, which involved detonating chemical explosives along with radionuclide tracers in an underground cavity, at the Nevada National Security Site (NNSS) in the United States. One of the radionuclide tracers, 127 Xe was released from the containment following the explosion and detected on a SAUNA Q B sampler situated approximately 3.5 km away. The system uses a beta-gamma coincidence detector system to measure fission product radioisotopes of xenon relevant to nuclear explosion monitoring. In this work we use the coincidence measurement data to analyse and interpret the results from the SAUNA Q B system, to calculate the measured 127 Xe activity concentration(s).

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

133Xe Noble Gas Mass Spectrometry Measurement for High Purity Germanium Detector Performance Verification

Idaho National Laboratory produces quality control standards for laboratories that operate xenon radionuclide monitoring systems. Activities reported with each quality control standard are quantified using high purity germanium detectors. A collection of measurement capabilities are being set up at Idaho National Laboratory to establish an in-house high purity germanium detector performance verification system, with noble gas mass spectrometry being one of these measurement capabilities. The first noble gas mass spectrometry and high purity germanium measurement comparison is presented here. A Xe-133 gas sample was prepared and the activity was quantified with high purity germanium detectors. The Xe-133 sample was diluted with a known quantity of isotopically enriched Xe-126 gas; the resulting Xe-133 : Xe-126 atom ratio was calculated to be 1.15x10-4 +/- 2% at reference time t. An aliquot of this gas sample containing approximately 10 million Xe-133 atoms was introduced into a ThermoFisher Scientific Helix MC Plus noble gas mass spectrometer for analysis. The measured Xe-133 : Xe-126 atom ratio was determined to be 1.10x10-4 +/- 2% (1-sigma uncertainty) at reference time t, about 4.3% lower than the atom ratio determined with the measured high purity germanium activity.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Characterization Techniques Investigated for Characterization of Anomalous Materials in Plutonium Oxide – 25666

The DOE has adopted a Dilute and Dispose approach for processing surplus plutonium which consists of blending plutonium oxide with adulterants and packaging it in a form which is acceptable for disposal at the Waste Isolation Pilot Plant. The feed material for the downblend process is intended to be pure plutonium oxide powder, however other objects are occasionally encountered within the oxide, particularly with legacy material. Potential technologies which could assist in the resolution of incidents where such anomalies are encountered have been investigated. Resolution of these incidents requires characterization of the anomalous object so that plutonium oxide processing can resume and so that a disposition pathway can be determined for the anomalous material. Technologies including gamma ray spectroscopy, alpha-gamma coincidence, LiDAR volumetric measurements, and surface conductivity measurements were investigated for this purpose, with a focus on systems which can be easily introduced into the processing environment when an anomaly is encountered, then removed from the environment after resolution to avoid impeding normal processing activities. This places an emphasis on small and portable measurement systems and systems that can operate in a high-background, oxide-processing environment. Gamma ray systems investigated include the GR1™a CZT detector and the MicroGe™a germanium detector, with a focus on detecting characteristic gamma rays from Pu-239 and other actinides. A gamma ray and alpha particle coincidence method was investigated with the goal of identifying actinides in the presence of a gamma ray background produced by adjacent plutonium oxide material. Leica™b BLK360 G1 and Keyence™c LJ-X8300 LiDAR systems were investigated for use in conjunction with mass measurements to gain accurate material density values, and a Foerster Sigmatest™d 2.070 was tested to determine surface conductivity. The combination of these properties would allow improved identification and characterization of a wide variety of potential anomalous material.

Munson, Justin M.↗

Field Measurement and Analysis of Frequency and RoCoF for Low-Inertia Power Systems

The frequency measurement and rate of change of frequency (RoCoF) calculations are important for active power, frequency control, and frequency-related protection in power system operations. With the rapid decrease in inertia under modern power systems, however, multiple power variations introduced by variable renewable energy bring large RoCoF and introduce oscillations in frequency measurements. To shed light on this issue, this article proposes a frequency measurement and RoCoF analysis technology, as well as the sensitivity analysis for the real low-inertia power grid. First, a real-world event in an island power grid is analyzed as an example, and an event numerical model is estimated considering four uncertainties, including event RoCoF, oscillation magnitude, oscillation frequency, and underfrequency load-shedding threshold. Then, a sensitivity analysis is performed using the Sobol indices method and quasi-Monte Carlo simulations to identify the dominant uncertainties based on the event model. Here, the dominant uncertainties are compared to provide a guideline for the frequency estimation algorithm selection under different event cases. This algorithm is compared with an enhanced zero-crossing algorithm and gives a 3.41% better RoCoF error rate. Finally, an experiment is conducted using universal grid analyzers to validate the simulation results and the theoretical analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Short-Lived Isotope Counting System (SLICS) to measure reaction cross sections producing light, beta-decaying nuclei on OMEGA

A new activation detector optimized for short-lived isotopes was designed, installed, and tested on OMEGA. The Short-Lived Isotope Counting System (SLICS) can be positioned as close as 35 cm from the OMEGA target chamber center in a ten-inch-manipulator. Stable target samples can be mounted on the front end of the detector assembly to undergo triton-, deuteron-, or neutron-induced reactions that produce short-lived reaction products that beta decay. The emitted betas are detected in a phoswich configuration to eliminate the gamma background. The detector is optimized for isotopes with half-lives from 150 ms to 20 s, filling a gap in OMEGA’s current activation detectors for isotopes with half-lives >5 min. In a pilot study, SLICS achieved an efficiency of 24.5% ± 2.0% for counting 8Li, with a total of 505.8 ± 4.4 qualifying events. Using the existing triton laser-ion acceleration platform on OMEGA, this detector can be used to measure rarely studied tritium-induced reactions on light nuclei with an estimated uncertainty of 12%. As a result, the design of the detector and its performance during a first experiment employing deuterium as a surrogate will be discussed.

Beta spectrometry↗

Assessment of Flow-Enhanced Electrochemical Sensor Testing and Deployments

The goal of our activities in FY24 was to enable advanced materials accountancy for molten salt reactors (MSRs) through the development and optimization of robust flow-enhanced electrochemical sensors (FEES) using a safeguards-focused sensor testing platform called the modular flow instrumentation testbed (MFIT). Flow-enhanced electrochemical sensors are a type of electroanalytical sensor that have been developed at Argonne National Laboratory to be installed directly into MSR flow conduits to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. Previous work has focused on testing of the FEES in flowing conditions provided by the MFIT to assess the accuracy and precision of the sensor measurements. This year, the FEES technical readiness was increased by (1) demonstrating the use of optimized sensor techniques to achieve measurements in very high-concentration MSR-relevant salts, (2) leveraging new multimodal sensors and automation approaches to reduce measurement uncertainties, and (3) fabricating and deploying sensors to industrial partners to improve their ability to make measurements in challenging environments. Additionally, we also ran the sensors during complex system operations involving combined flow and purification activities to demonstrate safeguards-relevant measurements during online processing for MSRs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessment of Thin Plastic Scintillation Detectors for Beta-Particle Measurements at the Advanced Test Reactor Critical Facility

The Fission Wire Measurement System is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical facility. The Advanced Test Reactor Critical facility is an open-pool, low-power test reactor used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in the Advanced Test Reactor. Power distribution measurements in ATR-C use uranium-aluminum wires that are distributed throughout the core to validate simulation and modeling results. These measurements require from 340 to 1500 wires to be irradiated and measured within a 12-hour window. The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. The gas flow detectors are of a custom design for this detector system that use methane gas with a large anode wire compared to modern proportional counters. These detectors, which are nearly 60 years old are irreplaceable. The measurements from these gas detectors are affected by the gas flow rate, atmospheric and line pressure, and are very sensitive to the applied high voltage. Recent improvements have been made to the control and data acquisition system, but the detectors have remained the same. The nature of the measurement of the fission product decay activity is such that the energy spectrum of the signal is changing with time. Thin, 250-um thick, plastic scintillators were commercially obtained as a potential replacement for the gas flow detectors. The original calibration of the uranium-aluminum fission wires was conducted in 1965 using a series of irradiations of gold foils and the wires in a well-characterized thermal neutron field. These measurements provided a time-dependent fission rate conversion factor from the gold foil data to calibrate the fission wires based on the response from the 2-pi proportional gas detectors. Transitioning to the new detectors requires qualification and testing. The sensitivity of the scintillators to changes in the energy spectrum of the fission wires and translation of the calibration factor have been completed. These measurements indicated that the sensitivity of the scintillators over time changes at a different rate than the sensitivity of the gas flow detectors. However, the inverse activity of measurements of both detector types is linear with time. Initial results indicate that the scintillator detectors will be a sufficient replacement for the gas detectors with minor adjustments to the fission rate conversion factor. Replacement of the detectors will improve the fission wire measurements and provide a more stable and reliable measurement system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Active and passive cooling approaches for a Southern California residential community

This study assesses cooling strategies in a low-income community in Southern California that lacks air conditioning and struggles with heat and air pollution. We used an urban building energy model and an electric distribution system model to evaluate active and passive cooling measures. The most effective space cooling measures were high-performance air-source heat pumps, cool coatings, window films, and harnessing the space cooling effect from heat pump water heaters. The results show that combining heat pump water heaters with window films and cool coatings reduces heat index hazard hours within buildings by 95 % to 99 % but increases total energy costs (equipment costs plus changes in utility bills) by 20 % to 60 % where the higher end includes building electrical upgrades. These measures also led to increased space heater use during colder months to avoid overcooling. Replacing conventional heaters with air source heat pumps eliminated unsafe indoor temperatures and reduced total energy use, but increased cost by 125 % to 150 %. In total, using heat pumps for space and water heating could reduce primary energy use by up to 57 %. The higher cost of active and passive cooling measures can be mitigated by existing and emerging incentive programs, especially those that support heat pumps. Electric distribution upgrades to support community electrification are estimated to increase utility costs by $\$$25 to $\$$40 per ratepayer per year. The results underscore the potential and challenges of adapting building infrastructure in communities at risk from climate and environmental stressors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High throughput battery failure experimental platform

Addressing the need to increase the sample set to understand the causes of lithium battery thermal runaway, we conceived of an experimental platform with capability to increase the number of runaway experiments (currently 3-5 per week), while also collecting detailed electrochemical impedance spectroscopy measurements (EIS). Once expanded, the platform would enable data collection on 10s to 100s of cells that all experience runaway, thereby creating a statistical database necessary to identify early indication of risk. A primary containment unit to house cylindrical cells of variety NMC811 and of size 21700 (21 mm diameter by 70 mm length) was designed with features such as debris containment, preloaded cells in an exchangeable port, nitrogen ventilation, and exhaust containment. We performed the first overcharge abuse experiments of several 21700 cells, handpicked because of different initial EIS, and demonstrated that EIS changes dramatically during early stages of overcharge, but in a different manner than previous pouch cell experiments. The abuse experiments also revealed the discharge pattern and debris field created during runaway, as well as the cell temperature control and overheat, that must be considered in the primary containment apparatus. We designed and built a switching relay system to permit measurement of EIS without an active charging circuit, and created instrument control software for charging, EIS, and cell temperature control. The late-start funding was insufficient to fully construct the primary containment unit, but the foundational design and knowhow is available for any future work.

25 ENERGY STORAGE↗

Scaled melter testing of alternative reductants for Low-Activity Waste vitrification: Melter feed properties and processing behavior

This study examines the use of boron nitride (BN) and coke dust as alternative reductants for low-activity waste vitrification in scaled melter systems, intended to enhance operational flexibility at the Hanford Waste Treatment and Immobilization Plant. The baseline reductant, sucrose, while widely considered advantageous for glass production rates, produces challenging off gas emissions during processing. Early crucible-scale testing indicated that BN and coke effectively control foaming and glass redox, while significantly reducing acetonitrile emissions. Both real tank waste and simulant waste melter feeds were tested with BN and coke in this study. Rheological properties for melter feeds with both reductants were within operational limits, although the particle size of coke should be controlled and sufficient agitation is necessary to ensure smooth operations. While promising for handling and reduction of emissions, both simulant melter feeds demonstrated lower average glass production rates in the simulant melter system compared with sucrose. In the radioactive system, the rates were more comparable to previously measured low activity waste feeds on the order of 1285 kg m 2 day −1 for BN and 1671 kg m −2 day −1 for coke. Further scale-up testing is required to interpret the processing rates in the context of the full scale melter systems and evaluate the cost-benefit impact of these reductants on efficiency and sustainability.

Rigby, Jessica C. [Pacific Northwest National Labo↗