Search NASA⌕ Search

SEARCH · Search NASA

Results for “adsorptive reactor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Field-Scale Testing of a High-Efficiency Membrane Reactor (MR)—Adsorptive Reactor (AR) Process for H2 Generation and Pre-Combustion CO2 Capture

The study objective was to field-validate the technical feasibility of a membrane- and adsorption-enhanced water gas shift reaction process employing a carbon molecular sieve membrane (CMSM)-based membrane reactor (MR) followed by an adsorptive reactor (AR) for pre-combustion CO2 capture. The project was carried out in two different phases. In Phase I, the field-scale experimental MR-AR system was designed and constructed, the membranes, and adsorbents were prepared, and the unit was tested with simulated syngas to validate functionality. In Phase II, the unit was installed at the test site, field-tested using real syngas, and a technoeconomic analysis (TEA) of the technology was completed. All project milestones were met. Specifically, (i) high-performance CMSMs were prepared meeting the target H2 permeance (>1 m3/(m2.hbar) and H2/CO selectivity of >80 at temperatures of up to 300 °C and pressures of up to 25 bar with a <10% performance decline over the testing period; (ii) pelletized adsorbents were prepared for use in relevant conditions (250 °C < T < 450 °C, pressures up to 25 bar) with a working capacity of >2.5 wt.% and an attrition rate of <0.2; (iii) TEA showed that the MR-AR technology met the CO2 capture goals of 95% CO2 purity at a cost of electricity (COE) 30% less than baseline approaches.

42 ENGINEERING↗

On multidomain multiscale modeling and simulation of a novel partial pressure and temperature swing adsorptive reactor ($\mathrm{PPTSAR}$) with application to the water gas shift reaction

Here in this work, a dynamic, multidomain, multiscale model of a novel Partial Pressure and Temperature Swing Adsorptive Reactor (PPTSAR) Process is developed and simulated for a Water Gas Shift Reaction (WGSR) application. The proposed model couples the reactor wall, catalyst/adsorbent pellet, and fluid mixture domains at their respective scales to comprehensively model mass, momentum, and energy transport phenomena occurring within each domain. The resulting model elucidates the PPTSAR’s start-up, transient, and long-term, periodic, dynamic behavior, during both adsorption/reaction and desorption operating modes. In the WGSR application considered, the use of two PPTSARs is shown to allow continuous operation that delivers CO conversion greater than 95% with simultaneous complete CO 2 capture.

42 ENGINEERING↗

A carbon molecular sieve membrane-based reactive separation process for pre-combustion CO 2 capture

In this study, we discuss a hybrid system combining a membrane reactor (MR) and an adsorptive reactor (AR), with the MR's reject stream serving as the AR's feed. We apply this system for the water gas shift (WGS) reaction for H 2 generation and simultaneous CO 2 capture in the context of the Integrated Gas Combined Cycle (IGCC) process for power generation from coal and biomass. This MR-AR system attains a high conversion exceeding equilibrium, produces a pure H 2 product for power generation, and delivers a high-pressure CO 2 stream ready for sequestration. Specifically, in our study we use carbon molecular sieve membranes (CMSMs) and a commercial sour-shift WGS catalyst. Lab experiments were carried-out to determine the membrane characteristics, and the MR performance under IGCC-relevant conditions, i.e., for temperatures up to 250 °C and pressures up to 25 bar, employing a model coal gasifier syngas. The CMSM and the catalyst have displayed robust and stable performance during a long-term run (~750 h of syngas exposure). We evaluated the MR-AR system in multi-cycle runs and it has demonstrated superior performance to that of a conventional packed-bed reactor, producing a high-purity H 2 product directly useable in a turbine for power generation. We conclude from the study, that the CMSM-based MR-AR system is a good candidate technology for environmentally-benign power generation. We are currently constructing a pilot-scale system for field demonstration of the technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A reactive separation process for pre-combustion CO 2 capture employing oxygen-blown coal gasifier off-gas

In this paper, we present an experimental study of a reactive separation system, consisting of a membrane reactor (MR) and an adsorptive reactor (AR) operating in tandem, with the MR’s reject stream serving as the AR’s feed. We investigates the feasibility of applying this MR-AR system for high-purity H 2 production and simultaneous CO 2 capture via the water gas shift (WGS) reaction in the context of Integrated Gas Combined Cycle (IGCC) power generation employing oxygen-blown gasifier syngas from biomass and coal. We previously studied this MR-AR system for the IGCC process employing air-blown gasifier syngas, for which it demonstrated good performance, attaining high conversion exceeding equilibrium, producing ultra-pure H 2 for power generation, and a CO 2 stream ready for sequestration. In this study, we focus on oxygen-blown gasifier off-gas that contains no N 2 , with composition distinctly different from the air-blown gasifier syngas which has a large N 2 content. We employ a carbon molecular sieve membrane (CMSM), a commercial sour-shift WGS catalyst, and a hydrotalcite (HTC) adsorbent. We carried out experiments to determine membrane performance and to identify promising operating conditions in an IGCC-relevant environment. The CMSM proved robust during a long-term (~344 hr run) experimental run under high temperature and pressure maintaining a high He/N 2 selectivity (~170). Multi-cycle runs were carried out during which the MR-AR system displayed superior performance to that of a PBR, by producing a high purity H 2 product directly usable in power generation. Therefore, the findings from this study demonstrate the ability of the MR-AR system to operate stably for a broad range of gasifier off-gas compositions, and indicate its potential for integration into IGCC plants for power generation with CO 2 capture.

01 COAL, LIGNITE, AND PEAT↗

Bench-Scale Testing of a High Efficiency, Ultra-Compact Process for Pre-Combustion CO 2 Capture (Final Report)

The overarching objective of this bench-scale study is to field-validate the technical feasibility of a membrane- and adsorption-enhanced water gas shift (WGS) reaction process that employs a carbon molecular sieve (CMS) membrane reactor (MR) followed by an adsorption reactor (AR) for pre-combustion CO 2 capture while demonstrating progress towards achievement of the overall performance goals of CO 2 capture with 95% CO 2 purity at a cost of electricity (COE) of 30% less than the baseline capture approaches. The main goal of this bench-scale project is to advance the proposed MR-AR transformative CO 2 capture technology to a sufficient maturity level so that our present industrial partners (M&PT and Worley) can potentially adapt the technology for further small pilot-scale testing. The project began at TRL 4, as the system prototype had already been validated in the laboratory on simulated syngas (as part of project DE-FE0026423). The project ended at TRL 5, via scaling-up of the prototype system and testing it on actual syngas at a host site (CAER at the University of Kentucky (UKy)). The project was carried-out in two different phases: In Phase I (during BP1 of the project), the team designed, constructed, and assembled the bench-scale experimental MR-AR system, prepared the membranes, adsorbents, and catalysts, tested the bench-scale unit with simulated syngas to validate functionality, and prepared a preliminary TEA of the technology. In Phase II (during BP2 of the project), the team installed the unit at the test site at the UKy site and completed all utility connections and hookups, field-tested the novel MR-AR process in the bench-scale system using real syngas, collected and analyzed experimental data, and completed a detailed TEA of the technology. A key aim of the project was to identify and address the technical and process risks and to generate information to advance the technology to the next stage of development. All project milestones and success criteria were met. Specifically, the team: (i) designed, constructed and assembled a bench scale system that handled 1 – 5 scfm syngas and tested its functionality with simulated syngas; (ii) prepared high performance CMS membrane tubes (ID: 3.5 mm, OD: 5.7 mm, 30” long) that meet the target H 2 permeance ( > 1 m 3 /(m 2 .hr.bar) or (> 370.3 GPU)) and a target H 2 /CO selectivity >80 at the relevant temperature (up to 300oC) and pressure conditions (up to 25 bar) with a <10% decline in performance over each 250 hr. testing period (iii) procured commercial sour-shift catalyst in sufficient quantity and prepared up to 10 kg of pelletized adsorbent for use at relevant conditions (250oC 2.5wt.% and target sorbent attrition rate < 0.2; (iv) installed the bench-scale unit at the test site (UKy) and tested the MR-AR technology using real syngas for over 250 hr. for both static and flow experiments; (v) updated the TEA analysis based on bench-scale data and met CO 2 capture goals of 95% CO 2 purity at a cost of electricity 30% less than baseline capture approaches. The CMS membranes, HTC adsorbents and catalysts employed all exhibited very robust and stable performance during the long-term run (over a >250 hr live syngas run). Furthermore, the proposed MR-AR IGCC system achieved a LCOE with a N 2 sale price of $\$$ 30/ton, with N 2 compression (no N 2 compression) of 101.2 $\$$/MWh (95.3 $\$$/MWh), which represents a 29.8% (33.9%) LCOE reduction in the baseline IGCC with carbon capture of 144.2 $\$$/MWh. The proposed MR-AR IGCC delivers a CO 2 capture cost of 44.8 $\$$/tonne (39.9 $\$$/tonne) vs 98.1 $\$$/tonne of the baseline capture case and a net power production of 586 MWe (623 MWe) vs 556 MWe of the baseline capture case.

01 COAL, LIGNITE, AND PEAT↗

Fermi-Based Kinetic Model for the Sabatier Reaction: Sabatier Principle and Beyond It

The CO 2 methanation reaction (aka the Sabatier reaction) is one of the important carbon utilization technologies to reduce atmospheric greenhouse gases. In this study, kinetic modeling of the Sabatier reaction proceeding via the CO route has been presented by considering weak and strong chemisorption concepts rooted in electronic theory. Based on the single-route mechanism of the Sabatier reaction, the dependence of the reaction rate on the position of the catalyst Fermi level with respect to the antibonding states of the reagent (CO 2 ) and the product (CH 4 ), is demonstrated with the classic Sabatier volcano-shape. Furthermore, the model was applied to explain experimental results of reaction rates for Ni- and Ru-based catalytic systems and to understand origin of enhancement of turnover frequencies established for dynamic catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reactor wall effects in Si–Cl 2 –Ar atomic layer etching

This work complements our previous manuscript [J. Vac. Sci. Technol. A41, 062602 (2023)] where predictions from molecular dynamics (MD) simulations of silicon–chlorine–argon (Si–Cl 2 –Ar) atomic layer etching (ALE) are compared to experiments. When etch product distributions for atomic chlorine (Cl) and silicon chlorides were initially compared to optical emission spectroscopy (OES) signals, it appeared that there was a discrepancy between the MD predictions and experimental results at higher ion fluences. Experiments showed a relatively long period of nearly constant Cl-containing etch products released from the ion-bombarded surface (referred to as the “plateau”) but this effect was not observed in MD simulations. In this report, we demonstrate that the “plateau” observed in the OES signals is most likely due to the desorption of Cl-containing etch products from the walls of the reactor and subsequent adsorption on the Si substrate. Experiments varying the gas residence time in the chamber while keeping incoming gas concentrations and pressure constant support this interpretation. We also conducted experiments with an additional Ar-only flow in the chamber to reduce the concentration of Cl-containing species on the chamber walls. For both sets of flow modification experiments, we observe results consistent with the hypothesis that Cl-containing species desorbing from chamber walls are a significant cause of the observed discrepancy between MD predictions and experimental observations. If the measured OES signals are corrected for this “additional” source of Cl-containing species at the surface, the MD predictions and measured OES signals are in excellent agreement. This further supports the predictive capability of MD simulations to accurately capture the relevant physical and chemical processes in plasma-assisted ALE processes. We provide an order of magnitude estimate of the required density of Cl-containing species that would account for the additional etch products observed. Finally, we discuss the implications of this effect on ALE in plasma nanofabrication.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of NO adsorption and desorption phenomena on a Pd/ZSM-5 passive NO x adsorber

Pd-based zeolite materials have gained significant attention as passive NO x adsorbers (PNAs) for diesel-engine cold-start NO x mitigation due to their ability to store NO x at low temperatures. Pd/ZSM-5 is a promising PNA candidate, however, the NO adsorption mechanism over this material is not well understood. This study combines flow reactor experiments and surface spectroscopy to investigate NO adsorption under a variety of conditions. Furthermore, the state of hydration of the Pd cations played an important role in determining the impact of H 2 O and CO concentration on the PNA performance. Below 150 °C, the inhibition effect of H 2 O on NO adsorption was mitigated by CO. Due to dehydration, neither H 2 O nor CO had an impact on NO uptake at 150 °C, where maximum NO storage capacity of the PNA was also observed. The observed gas composition and temperature effects on NO adsorption and formation of surface intermediates ultimately inform a proposed mechanism.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

First-Principles Studies of Tritium Species Dissociability & Diffusivity Across the Interface of Nickel-Plated Zircaloy-4

Zirconium (Zr) and its alloys (Zircaloy-4) are widely used in nuclear reactors due to their low neutron adsorption cross-section and excellent corrosion resistance. In tritium-producing burnable absorber rods (TPBARs), the metal getter tube located between the cladding and the γ-LiAlO 2 pellets is composed of nickel (Ni)-plated Zircaloy-4, which is used to capture tritium ( 3 H) species (mainly 3 H 2 and 3 H 2 O) generated from γ-LiAlO 2 pellets during irradiation. The 3 H-related products transfer to the surface of metal Ni upon adsorption and dissociation to form new 3 H species and diffuse into the Zircaloy-4 getters to form metal hydrides (Zr 3 H x ). Therefore, exploring 3 H species ( 3 H 2 , 3 H 2 O) dissociation on the surface of Ni and diffusion across the interface of Ni-plated Zircaloy-4 getters can provide a better understanding of 3H species formation and transport from pellets into the getters.

36 MATERIALS SCIENCE↗

Machine Learning-Assisted Recovery of Delicate Kinetic Information from Transient Reactor Experiments

Identifying active sites and their roles in chemical reaction steps remains a vital challenge in heterogeneous catalysis. Transient experiments offer a unique way to probe active sites and distinguish subtle kinetic features. Although physics-based analysis methods may be well-developed, they can be highly susceptible to experimental noise, and smoothing methods may erase or even distort important features; a smooth curve is not always the best curve. We demonstrate a new workflow for the direct interpretation of intrinsic kinetic information from exit flux curves measured in transient reactor experiments. This workflow contains three artificial neural networks (ANNs), including a noise reducer, a concentration predictor, and a rate predictor to analyze experimental data, followed by the virtual TAP (VTAP) physics-based reactor model and density functional theory (DFT) calculations of adsorption energies on specific sites. We use this workflow to analyze the data from experiments titrating Pt/Al 2 O 3 and Pt/SiO 2 catalysts with carbon monoxide (CO) in the temporal analysis of products (TAP) reactor. Our workflow separates the time-evolving chemical reaction and mass transfer information contained in the TAP pulse response. The existence of strong- and weak-binding sites on the Pt/Al 2 O 3 catalyst is observed in the catalyst titration experiment in the transient reactor. The structures of the strong- and weak-binding sites are then identified by using DFT calculations. We find that the Pt/SiO 2 catalyst has only strong-binding sites, which aligns with the inactive support effect of SiO 2 . We demonstrate how machine learning methods provide unique insights with high-resolution data analysis that cannot be achieved by using state-of-the-art physics-based methods.

Adsorption↗

Pilot Testing of a Highly Efficient Pre-combustion Sorbent-based Carbon Capture System

TDA developed and demonstrated a highly efficient pre-combustion carbon capture system. The overall objective of this work was to develop a new sorbent-based pre-combustion carbon capture technology for Integrated Gasification Combined Cycle (IGCC) power plants. In this project our goal was to demonstrate the techno-economic viability of the new technology by 1) demonstrating it in large-scale slipstream tests, and 2) carrying out a high fidelity engineering and cost analysis. TDA’s process used an advanced physical adsorbent that selectively removes CO 2 from coal-derived synthesis gas above the dew point of the gas at temperatures as high as 300°C. The sorbent consists of a mesoporous carbon whose surface was grafted with functional groups that remove CO 2 via a well-known acid-base interaction. As documented in bench-scale experiments and field tests with actual coal gas, the sorbent achieved a very high capacity for CO 2 at temperatures as high as 300°C. The sorbent bound CO 2 more strongly than common physical adsorbents, providing the chemical potential needed for the high temperature operation. However, because CO 2 does not form a true covalent bond with the surface sites (as is the case with chemical absorbents), the sorbent regeneration could be carried out with only a very small energy input. The heat input to regenerate our sorbent was only 4.9 kcal per mol of CO 2 , which is much lower than that for chemical absorbents (e.g., 29.9 kcal/mol CO 2 for sodium carbonate) and was similar to the requirements of physical solvents (e.g., 4 kcal/mol CO 2 for Selexol TM ). Because the sorbent operates above the dew point of the synthesis gas (unlike the Selexol TM process), a higher power cycle efficiency can be achieved. With previous DOE/NETL funding (Contract No. DE-FE-0000469), we demonstrated the techno-economic viability of the technology in bench-scale tests and slipstream demonstrations at the National Carbon Capture Center (NCCC), Wilsonville, Alabama and Wabash River IGCC plant in Terra Haute, Indiana. We demonstrated a stable working CO 2 capacity for over 11,650 cycles with simulated synthesis gas. We also evaluated its performance with actual synthesis gas in two test campaigns at the Wabash River IGCC Plant, Terre Haute, IN and the National Carbon Capture Center (NCCC), Wilsonville, AL. The slipstream tests clearly showed that the actual coal gas constituents and potential contaminants (e.g. trace metals, halides, tars) had no effect on the sorbent’s ability to remove CO 2 (the same sorbent beds were used in both field tests with no sign of deactivation for 2,000 cycles with over 26,750 SCF of gas treated). As expected, due to the high temperature CO 2 removal capability and low energy needed to regenerate the sorbent, the power cycle efficiency with our process was greater than 34% on a higher heating value (HHV) basis; in comparison, the same IGCC plant equipped with the Selexol TM solvent for carbon capture can only achieve 31.4% HHV efficiency. The capital cost for an IGCC system with TDA’s process is estimated as $2,417/kW e , which is 12% lower than that of the IGCC/ Selexol TM process. The levelized cost for electricity including the transport, storage and monitoring (TS&M) cost for CO 2 was calculated as $\$ $92.9/MWh (lowest reported to our knowledge), which is much better than the $105.2/MWh estimated for the IGCC/ Selexol TM process. In this project (DE-FE0013105), TDA Research, in collaboration with our partners Gas Technology Institute (GTI), Illinois Clean Coal Institute (ICCI), University of California, Irvine (UCI), University of Alberta (UOA), Siemens, NCCC and Sinopec advanced the technical maturity of the technology; scaling it up by a factor of 100. We optimized the reactor design using computational fluid dynamics (CFD); using adsorption modeling we improved the pressure swing adsorption (PSA) cycle sequence. We carried out two field test campaigns with a fully-equipped 0.1 MW e prototype unit (for a total of 844 hours) using actual synthesis gas to prove the viability of the new technology. A successful 30 day (707 hrs) evaluation was completed at NCCC under air blown gasification conditions. We demonstrated 97.3% carbon capture at 1,500 SLPM, 93% carbon capture at 1,800 SLPM, and 90% carbon capture at 2,100 SLPM in the NCCC tests. We also demonstrated the system for 137 hours at a Sinopec petrochemical plant under oxygen blown gasification, demonstrating 86% carbon capture at 2,660 SLPM. In collaboration with University of California, Irvine (UCI), we completed a techno-economic analysis (TEA) for TDA’s warm gas cleanup technology integrated to IGCC power plant. The net plant efficiencies (on a coal HHV basis) for the warm gas cleanup cases were estimated to be 34.0% for E-GasTM gasifier, 34.4% for GE gasifier, 33.4 for the Shell gasifier and 34.2 for the TRIG TM gasifier (Cases 2, 4, 6 and 8 in this study) with a catalytic combustor for CO 2 purification, which are significantly higher than those for the Cold Gas Case, or an increase of as much as 12% in the heat rate for Case 2, 6% for Case 4, 9% for Case 6, and 9% for Case 8. The 1st year cost of electricity with the transport, storage and monitoring (TS&M) costs for the CO 2 included was $\$ $129.2/MWh for the E-GasTM gasifier Warm Gas Cleanup Case, $\$ $131.9/MWh for the GE gasifier Warm Gas Cleanup Case, $\$ $146.8/MWh for the Shell Gasifier Warm Gas Cleanup Case, and $\$ $129.9/MWh for the TRIG TM gasifier Warm Gas Cleanup Case. For comparison, the costs for the baseline Cold Gas CO 2 removal with Selexol for the different gasifiers were: $\$ $146.6/MWh for the E-Gas TM gasifier, $\$ $142.2/MWh for the GE gasifier, $\$ $159.0/MWh for the Shell gasifier and $\$ $144.3/MWh for the TRIG TM gasifier. In summary, the costs for our system were 7 to 12% lower than the corresponding Cold Gas Cleanup cases. The results of this techno-economic analysis suggested that TDA’s high temperature PSA-based Warm Gas Clean-up Technology can make a substantial improvement in the IGCC plant thermal performance for achieving near zero CO 2 emissions for E-Gas TM , GE, Shell and TRIG TM gasifier based IGCC power plants. The capital expenses were estimated to be lower than that of Selexol’s™. Taken together, the higher net plant efficiency and lower capital and operating costs resulted in substantial reduction in the cost of carbon capture for the IGCC plant equipped with TDA’s high temperature PSA-based carbon capture system. Finally, in collaboration with Gas Technology Institute (GTI) we completed the environmental health and safety assessment for TDA’s warm gas carbon capture technology.

01 COAL, LIGNITE, AND PEAT↗