Search NASA⌕ Search

SEARCH · Search NASA

Results for “advanced grid-support functions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

IEEE 1547-2018 Based Interoperable PV Inverter with Advanced Grid-Support Functions

Grid integration of photovoltaic (PV) inverters has been increasing in the past decade. As a result of the uncertainties introduced with high penetrations of PV, better monitoring and control of the PV inverters becomes crucial for improving overall system stability. This paper focuses on the communications capability of the inverter controller and on enabling interoperability. Multiple standards are available to enable interoperability in PV inverters. In this paper, an interoperable controller, enabled by Distributed Network Protocol 3 (DNP3) communications protocols, is developed for a grid-connected, three-phase PV inverter. The DNP3 server for the PV inverter is programmed on the real-time layer of the field-programmable gate array (FPGA)-based inverter controller. Set points for advanced inverter control functions, such as volt/VAr curves, ride-through curves, are sent from a DNP3 client, a simulated distribution management system application, to the PV inverter through DNP3. This communications capability of the inverter controller is validated using a controller-hardware-in-the-loop experimental setup. The code developed to achieve the interoperability is available in the public domain through open-source software licensing. This interoperability will enable smoother grid integration of smart PV inverters with advanced grid-support functions as well as allow better monitoring and control of PV inverters for grid stability.

14 SOLAR ENERGY↗

Circulating Current Reduction of Back-to-Back MMC with Advanced Grid-Support Functionalities for Medium-Voltage Applications

A Lyapunov energy function based circulating current reduction scheme for a back to back modular multilevel converter based system for a microgrid application has been proposed in this digest. In order to ensure no circulating or zero sequence currents within the modules, the dynamics from one leg of the converter to the other are evaluated. A Lyapunov energy function is then developed and utilizing the circulating current dynamics of the converter the overall control law is implemented. In this digest a decentralized hierarchical control architecture has been implemented for the main current control; where the outer loop or the central controller implements the higher level grid interconnection functions as per IEEE 1547-2018 standards and the inner loop based on synchronous reference frame implements the current control architecture. The inner loops' outputs are the commanded converter voltages either on either side which are augmented by the Lyapunov energy function based circulating current suppression architecture. To evaluate the efficacy of the overall system, the overall system is modeled around a 300kVA back to back SiC multilevel modular converter used as a direct-connected medium voltage (MV) grid intertie based on MATLAB/Simulink domain. Several important case studies are presented in this paper to prove the effectiveness of the proposed architecture. case study results are presented.

circulating current↗

Controller-Hardware-in-the-Loop Test Bed for Fast-Switching SiC-Based 50-kW PV Inverter

The recent advent of wideband gap power semiconductor devices will lay the path to the future power converters. These devices provide the advantage of high switching speed and lower losses. The high cost and high switching speeds of these devices provide a challenge in the development and validation of the fast switching inverter controls with accuracy of that of a hardware setup. In this paper an FPGA real-time simulator-based controller-hardware-in-the-loop (CHIL) testbed is used to verify the low-level and advanced inverter controls fast switching wide bandgap-based string photovoltaic inverter. The paper also includes development of the CHIL testbed, which is run at a time-step of 500 ns in order to implement 20 kHz switching frequency. The developed CHIL testbed is validated through experimental results from a three-phase, 50 kW, 480 VLLrms SiC devices based inverter.

14 SOLAR ENERGY↗

Advanced Inverter Voltage Controls: Simulation and Field Pilot Findings

This report describes work performed by the Hawaiian Electric Companies and the National Renewable Energy Laboratory (NREL) to model and simulate advanced inverter grid-support functions and to validate and expand on those simulations through a field pilot study. This work builds on earlier research, referred to as the Voltage Regulation Operational Strategies study. The objective of both is to investigate functionalities available in most photovoltaic (PV) inverters to modulate active and reactive power autonomously based on local voltage measurements for the purpose of mitigating off-nominal grid voltage conditions. Specifically of interest are volt/volt-ampere reactive (VAR) control and volt/watt control, the effect of those functions on quasi-steady-state feeder voltages, and the impact of the functions on PV energy production. Because volt/VAR and volt/watt control autonomously adjust inverter output based on local conditions without requiring communication with any other devices, they are good candidates to increase PV hosting capacity when it is limited by voltage constraints in a feeder with very large numbers of PV systems.

14 SOLAR ENERGY↗

Evaluation of Adaptive Volt-VAR to Mitigate PV Impacts [Slides]

Distributed generation (DG) sources like photovoltaic (PV) systems with advanced inverters are able to perform grid-support functions, like autonomous Volt-VAR that attempts to mitigate voltage issues by injecting or consuming reactive power. However, the Volt-VAR function operates with VAR priority, meaning real power may be curtailed to provide additional reactive power support. Since some locations on the grid may be more prone to higher voltages than others, PV systems installed at those locations may be forced to curtail more power, adversely impacting the value of that PV system. Adaptive Volt-VAR (AVV) could be implemented as an alternative, whereby the Volt-VAR reference voltage changes over time, but this functionality has not been well-explored in the literature. In this work, the potential benefits and grid impacts of AVV were investigated using yearlong quasi-static time-series (QSTS) simulations. After testing a variety of allowable AVV settings, we found that even with aggressive settings AVV resulted in <0.01% real power curtailment and significantly reduced the reactive power support required from the PV inverter compared to conventional Volt-VAR but did not provide much mitigation for extreme voltage conditions. The reactive power support provided by AVV was injected to oppose large deviations in voltage (in either direction), indicating that it could be useful for other applications like reducing voltage flicker or minimizing interactions with other voltage regulating devices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Inverter Reliability Estimation for Advanced Inverter Functionality

In the near future, grid operators are expected to regularly use advanced distributed energy resource (DER) functions, defined in IEEE 1547-2018, to perform a range of grid-support operations. Many of these functions adjust the active and reactive power of the device through commanded or autonomous modes, which will produce new stresses on the grid-interfacing power electronics components, such as DC/AC inverters. In previous work, multiple DER devices were instrumented to evaluate additional component stress under multiple reactive power setpoints. We utilize quasi-static time-series simulations to determine voltage-reactive power mode (volt-var) mission profile of inverters in an active power system. Mission profiles and loss estimates are then combined to estimate the reduction of the useful life of inverters from different reactive power profiles. It was found that the average lifetime reduction was approximately 0.15% for an inverter between standard unity power factor operation and the IEEE 1547 default volt-var curve based on thermal damage due to switching in the power transistors. For an inverter with an expected 20-year lifetime, the 1547 volt-var curve would reduce the expected life of the device by 12 days. This framework for determining an inverter's useful life from experimental and modeling data can be applied to any failure mechanism and advanced inverter operation.

component degradation↗

Impacts of Voltage-Based Grid-Support Functions on Energy Production of PV Customers: Preprint

This paper presents the impact of grid-support utility-interactive inverter functions, such as volt/volt-ampere reactive and volt/watt controls, on quasi-steady-state feeder voltages and on photovoltaic (PV) customer energy production on a real distribution feeder in Oahu, Hawai'i. These autonomous inverter controls provide an effective means to modulate active and reactive power based on local voltage measurements and therefore serve as good candidates for non-wire alternatives to increase PV hosting capacity. However, because the activation of these functions can result in PV energy curtailment, this study addresses the concerns about the impact of these advanced inverter controls on curtailment through detailed quasi-static time series (QSTS) simulations. This study proposes four metrics-maximum and average grid-support function curtailments, average increased generation, and average net generation change-to assess the impact of a given control on PV systems located on customer sites. For representative scenarios modeled in detail, it was found that curtailment of PV production is negligible for customers where peak voltage is within ANSI C84.1 ranges. A reliable relationship between curtailment and peak customer voltage is demonstrated, allowing peak voltage to be used as an indicator of curtailment without the need to measure curtailment directly.

14 SOLAR ENERGY↗

Automating Component-Level Stress Measurements for Inverter Reliability Estimation

In the near future, grid operators are expected to regularly use advanced distributed energy resource (DER) functions, defined in IEEE 1547-2018, to perform a range of grid-support operations. Many of these functions adjust the active and reactive power of the device through commanded or autonomous operating modes which induce new stresses on the power electronics components. In this work, an experimental and theoretical framework is introduced which couples laboratory-measured component stress with advanced inverter functionality and derives a reduction in useful lifetime based on an applicable reliability model. Multiple DER devices were instrumented to calculate the additional component stress under multiple reactive power setpoints to estimate associated DER lifetime reductions. A clear increase in switch loss was demonstrated as a function of irradiance level and power factor. This is replicated in the system-level efficiency measurements, although magnitudes were different—suggesting other loss mechanisms exist. Using an approximate Arrhenius thermal model for the switches, the experimental data indicate a lifetime reduction of 1.5% when operating the inverter at 0.85 PF—compared to unity PF—assuming the DER failure mechanism thermally driven within the H-bridge. If other failure mechanisms are discovered for a set of power electronics devices, this testing and calculation framework can easily be tailored to those failure mechanisms.

Flicker, Jack (ORCID:0000000212232154)↗

Optimal Distribution System Voltage Regulation using State Estimation and DER Grid-Support Functions

Increasing solar energy penetrations may create challenges for distribution system operations because production variability can lead to large voltage deviations or protection system miscoordination. Instituting advanced management systems on distribution systems is one promising method for combating these challenges by intelligently controlling distribution assets to regulate voltage and ensure protection safety margins. While it is generally not the case today, greater deployment of power system sensors and interoperable distributed energy resources (DER)e.g., photovoltaic (PV) inverters, energy storage systems (ESS), electric vehicles (EVs)will enable situational awareness, control, and optimization of distribution systems. In this work, a control system was created which measures power system parameters to estimate the status of a feeder, forecasts the distribution state over a short-term horizon, and issues optimal set point commands to distribution-connected equipment to regulate voltage and protect the system. This two-year project integrated multiple research innovations into a management system designed to safely allow PV penetrations of 50% or greater. The integrated software was demonstrated through extensive real-time (RT) and power hardware-in-the-loop studies and a field demonstration on a live power system with a 684 kVA PV system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Clean Grid Vision: A U.S. Perspective - Chapter 3. Transmission Grid-Supporting Technologies

High renewable penetration will bring different challenges to power system reliability and stability. Reduction of inertia has been of concern for more wide-spread instable events; however, with the advanced control functionalities provided by power electronics interface and proper storage compensation, renewable generators are capable of providing wide-range of grid services that can maintain and improve grid reliability and stability matrices. Many studies and testing has demonstrated those functions and many pilot projects throughout the world had proved the concepts are working.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Field Validated Utility-Scale Battery Storage Control Models for Quasi-Static Analyses

This paper presents a co-simulation based approach to implement and validate advanced battery storage control modes in OpenDSS that replicate behavior of a utility scale vanadium red-ox flow battery (VRFB). Inverter-interfaced utiliy-scale battery storage systems (BSS) have modes of operation to facilitate multiple grid-support functions. In order to enable accurate understanding of the impacts from grid-support functions modes of operation it is required to develop validated models that replicates behavior of the actual control system. This paper presents the pseudo code for the implemented control schemes including peak shaving and capacity firming control modes. Additionally, this paper also provides insight on convergence sensitivity of the presented algorithms to related parameters. The results obtained from simulation studies will be compared against field operated utility-scale BSS measurements to verify the implemented algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Inverter Testing for Verification of Hawaiian Electric Rule 14H: Preprint

As utilities increasingly require inverters perform grid-supportive functions, it is challenging to ensure that those functions are properly configured in the field. This paper details inverter testing carried related to Hawaiian Electric's latest rule 14H interconnection requirements to validate that field installation procedures result in the intended advanced inverter behavior. The latest Volt-VAR, Volt-Watt, and frequency-Watt curves in Hawaiian Electric's Source Requirement Document (SRD) V1.1 for UL 1741 Supplement A were tested for two inverter manufacturers used in the utility territory. Both inverters were found to be largely compliant, though several discrepancies were identified and reported to the manufacturers to be addressed. The results are presented and discussed here.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Inverter Testing for Verification of Hawaiian Electric Rule 14H

As utilities increasingly require inverters to perform grid-supportive functions, it is challenging to ensure that those functions are properly configured in the field. This paper presents details of inverter testing related to Hawaiian Electric's latest rule 14H interconnection requirements to validate that field installation procedures result in the intended advanced inverter behavior. The latest Volt-VAR, Volt-Watt, and frequency-Watt curves in Hawaiian Electric's Source Requirement Document (SRD) V1.1 for UL 1741 Supplement A were tested for two inverter manufacturers used in the utility territory. Both inverters were found to be largely compliant, though several discrepancies were identified and reported to the manufacturers. The results are presented and discussed here.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Implementation of Advanced Grid Support Functionalities by Smart Operation of Residential Loads with low Cost Converter Interface

This paper investigates a grid-supportive load concept for small-scale residential appliances, focusing on a residential refrigerator. Power consumption is adjusted based on grid conditions to achieve IEEE-1547 grid support functions. Two key aspects are presented: a low-cost refrigerator converter with Lyapunov energy function-based local controllers for speed control, and the impact on a standard microgrid system, demonstrating advanced grid support from the load side. This method enhances grid resilience and reliability and can be extended to other residential loads. The study contributes to efficient and robust grid-supportive load management systems, showing promising performance. This approach has the potential to improve overall grid stability and can be adapted for various types of residential appliances. The modeling and simulations in MATLAB/Simulink and PLECS confirm the feasibility and effectiveness of the proposed solution. Future work will explore real-world implementation and scalability of this concept for broader applications.

grid supportive loads (GSL)↗

Advanced Photovoltaic Inverter Control Development and Validation in a Controller-Hardware-in-the-Loop Test Bed

Penetration of solar photovoltaic (PV) installations into the grid has increased in recent years. In the past, photovoltaic installations have not included grid-support functionality. Grid support functions including Volt-VAR (VVAR), Frequency-Watt (FW), Volt-Watt (VW), frequency/voltage-ride through, as well as other inverter functions such as anti-islanding are recommended by standards such as IEEE 1547 to allow PV inverters to contribute to acceptable operation and stability of distribution systems with high penetrations of PV and to ensure predictable response of the PV inverters. First, low-level and high-level grid support inverter control functions were developed and tested in simulation. The developed controller is able to integrate advanced controller functions in a coordinated approach, avoiding any conflict between the different control objectives. The algorithms were then programmed on an off-the-shelf embedded controller that included a dual-core CPU and FPGA. The details of the high-level grid support function and the lower level switching control will be presented. Second, this programmed controller is tested using a controller-hardware-in-the-loop (CHIL) test bed setup using an FPGA-based real-time simulator. The CHIL setup has the capability to run at a 500 nano-second time-step to accommodate the 20 kHz switching frequency of the developed controller. The advanced control function and CHIL test bed details provided here will aide future researchers to design, implement, and test advanced inverter functions for PV inverters.

14 SOLAR ENERGY↗

Control and Grid Support Function Evaluation for a Three-Phase Back-to-Back Modular Multilevel Converter System

This paper focuses on the evaluation of advanced inverter controls for a 500kW back-to-back (B2B), silicon carbide, multilevel modular converter (MMC) used as a direct-connected medium-voltage grid intertie. A decentralized hierarchical controller architecture for the MMC system is presented, which uses the main controller to implement higher level grid interconnection functions per the IEEE 1547–2018 standards and the local controllers to execute lower level closed-loop functionality of the MMC stages. This paper presents and elaborates on the grid functionalities are elaborated and presented. The back-to-back converter system is equipped with local controllers and their corresponding functionalities are presented. Case study results for the corresponding functionalities presented show the effectiveness of the proposed architecture. To enhance the operation capabilities of the system, a parameter update scheme has been implemented and utilized in unison with the controller.

decentralized control↗

Impacts of Voltage-Based Grid Support Functions on Energy Production of PV Customers

This paper presents the impact of inverter grid- support functions (GSFs) on photovoltaic (PV) customer energy production on a real distribution feeder in Oahu, HI. These autonomous GSFs based on local voltage measurements are good alternatives to increase PV hosting capacity. However, these functions can result in PV energy curtailment to the customer, and this study addresses the concerns about the impact of inverter GSFs through detailed quasi-static time series (QSTS) simulations. It proposes four metrics: maximum and average GSF curtailment, average increased generation and average net generation change, to assess the impact of a given control on PV systems located on customer sites. It was found that curtailment of PV production is negligible for customers where peak voltage is within ANSI C84.1 range. A reliable relationship between curtailment and peak customer voltage is demonstrated, suggesting that peak voltage could be used as an indicator of customer curtailment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Autonomous Grid Support Functionality in Variable-Speed Drive-Based End-Use Loads

High penetration of inverter-based resources into power systems causes lower inertia, and it becomes more challenging to maintain grid stability during contingency events. While conventional demand response and shedding at the load side suffer from slow response, impact by unavailability, and issues from communication, variable-speed drives (VSDs) are becoming strong candidates for fast frequency response (FFR) thanks to their fast response and reduced user impact from variable power adjustment capability. In this letter, we propose an autonomous frequency support control method for a residential refrigerator with a VSD, a promising target small end-use load for FFR. We analyze the effect of the proposed controller on grid stability, and we verify the performance through laboratory experiments with a commercially available refrigerator.

24 POWER TRANSMISSION AND DISTRIBUTION↗