Heat Batteries for Deep Decarbonization of the Beverage Industry
There has been significant progress towards the Go/No-Go Review Criteria for both sub-projects to prepare the project to enter Budget Period 2 in July.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
There has been significant progress towards the Go/No-Go Review Criteria for both sub-projects to prepare the project to enter Budget Period 2 in July.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A turbine engine assembly includes a heat exchanger that is in thermal communication with an exhaust gas flow. A bypass passage is provided that is configured to selectively route at least a portion of the exhaust gas flow around the heat exchanger in response to a predefined engine operating condition.
In this project, robust heat-flux measurement systems were developed. The heat-flux sensors utilize thermoelectric effects to directly transduce the heat-flux inputs to analog electrical voltage signals. They were constructed from dedicated materials that can withstand temperatures of at least 1000°C and maintain adequate performance at these conditions for prolonged periods of time. The proposed approaches took into account numerous considerations, including system cost, sensor head resilience, sensor footprint, data accuracy, response time, and maintenance requirements. Through modern thermoelectric materials design, methodical materials selection and rigorous testing in materials characterization labs and medium-scale fire research facilities, we have demonstrated functioning laboratory prototypes, upon which one could base industrial heat-flux sensing platforms capable of operating in the challenging high-temperature, corrosive environments of the boilers of coal-fired power plants. A distributed sensor array for heat-flux measurements throughout the furnace water-wall, the superheater area and the economizer coils can provide critical data for the power plant control systems to increase efficiency, improve safety and reduce down times. For example, the combined heat-flux sensor/control systems can contribute to the optimization of burner and boiler operations under flexible loads, the optimization of heat-exchange conditions and overall reduction of heat rate and emissions, the prediction of imminent overheating conditions, and the optimization of the soot-blowing protocols.
Observations (from thermistor sensors and a hurricane glider) and model-based temperature were used to answer questions including the following: 1) What physical and environmental conditions explain the rapid intensification of Hurricane Laura? 2) How did the pre-existing warm mixed layer at Stone mooring (StM) influence the degree of cooling in the mixed layer? 3) How did vertical mixing, surface heat fluxes, and advective processes collectively shape the mixed layer heat evolution at StM? Observations measured by thermistor sensors showed that Hurricane Laura induced a cooling of -1.2oC in the mixed layer when Hurricane Laura’s wind speed increased to 47 m/s on 26 August. This contrasts with the -1.04oC mixed layer temperature change estimated from model-based temperature. At StM, the presence of a 31oC warm mixed layer and elevated heat content (60-80kJ/cm2) effectively preconditioned the upper ocean ahead of Hurricane Laura’s passage. After Hurricane Laura passed, turbulent mixing associated with the storm transported the heat anomalies downward into subsurface layers. In addition, this study shows that a surface heat flux of 5.04 kJ/cm2 supported the intensity of Hurricane Laura as it traversed over the StM. Using a mixed layer heat balance model, this study shows that entrainment flux and surface flux mostly contributed to the observed change in the mixed layer temperature.
This work focused on improving the understanding and modeling of conjugate heat transfer in the Stable Salt Reactor (SSR), particularly the transfer of heat from molten fuel salt inside narrow fuel pins, through the metal cladding and into the surrounding coolant salt.
In this paper, we present socio-techno-economic simulation results for enhanced geothermal system (EGS) district heating systems in the northeastern United States. We applied the geospatial Distributed Geothermal Market Demand (dGeo) tool coupled with GEOPHIRES to evaluate the feasibility of geothermal deep direct-use, utilizing EGS reservoirs for providing residential heating with district heating systems. The results were combined with JEDI results to assess social impacts. Simulation results assuming doublet EGS reservoirs with target production temperature of 80 degrees C and newly constructed district heating systems indicate a wide range in system levelized cost of heat (LCOH) values ranging from ~$15/MMBtu to over $1,000/MMBtu, with most the attractive regions urban areas with high total thermal demand and high thermal demand density. We estimate about 60 GWth in potential installed capacity with LCOH values under $50/MMBtu and 100 GWth in potential capacity with LCOH values under $100/MMBtu, respectively.
Extreme heat is intensifying worldwide, yet estimates of heat hazard and exposure inequality depend on both the heat metric and how extreme days are defined. Using summer 2022 across the Mediterranean, we quantify population heat exposure with four metrics—land surface temperature (LST), air temperature (Ta), heat index (HI), and wet-bulb globe temperature (WBGT)—under absolute (fixed-value) and relative (anomaly-based) thresholds. Under absolute thresholds, total heat exposure differs by more than two orders of magnitude across metrics (31.3 billion person-days for Ta vs 0.3 billion for HI). Geographic hotspots also diverge: WBGT concentrates in humid coastal North Africa (e.g. the Nile Delta), whereas Ta and LST are more widespread. Under relative thresholds, exposure totals converge and cross-metric hotspot agreement increases (e.g. Ta–WBGT top-tercile overlap increases from 10.7% to 29.0%), shifting hotspots toward densely populated southern Europe. Crucially, the exposure–deprivation relationship also reverses across threshold frameworks: absolute thresholds concentrate exposure in more deprived North Africa and the Middle East, whereas relative thresholds shift the burden toward less-deprived European cities. This sensitivity is decision-relevant: city rankings based on WBGT exposure duration are almost completely reordered when switching threshold frameworks. Threshold choice therefore systematically reshapes hotspot patterns and inequality signals. Reporting both absolute and relative exposures can reveal hidden hotspots and support more targeted heat-risk monitoring and intervention planning.
Explore the source record for details and available documents.
This report is part of series describing a variety of different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.
This report is part of series describing a variety of different ResStock™ measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) with Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.
Temperature control is crucial for live cell imaging, particularly in studies involving plant responses to high ambient temperatures and thermal stress. This study presents the design, development, and testing of two cost-effective heating devices tailored for confocal microscopy applications: an aluminum heat plate and a wireless mini-heater. The aluminum heat plate, engineered to integrate seamlessly with the standard 160 mm × 110 mm microscope stage, supports temperatures up to 36°C, suitable for studies in the range of non-stressful warm temperatures (e.g., 25-27°C forArabidopsis thaliana) and moderate heat stress (e.g., 30-36°C forA. thaliana). We also developed a wireless mini-heater that offers rapid, precise heating directly at the sample slide, with a temperature increase rate over 30 times faster than the heat plate. The wireless heater effectively maintained target temperatures up to 50°C, ideal for investigating severe heat stress and heat shock responses in plants. Both devices performed well in controlled studies, including the real-time analysis of heat shock protein accumulation and stress granule formation inA. thaliana. Our designs are effective and affordable, with total construction costs lower than $300. This accessibility makes them particularly valuable for small laboratories with limited funding. Future improvements could include enhanced heat uniformity, humidity control to mitigate evaporation, and more robust thermal management to minimize focus drift during extended imaging sessions. These modifications would further solidify the utility of our heating devices in live cell imaging, offering researchers reliable, budget-friendly tools for exploring plant thermal biology.
The widespread adoption of electric-driven heat pumps for heating and cooling is expected to significantly increase electric demand. Cooling electric demand will result in an increase in peak hours electric loads, placing additional strain on the grid during peak hours. This challenge, combined with the current rapidly increasing demand from data centers, exacerbates the electric demand duck curve problem. Integrating thermal energy storage (TES) with heat pump can shift electric use for heating and cooling from peak to off-peak hours of the electric grid, which can help flatten the daily electric demand profile of a building. This paper presents a novel design that integrates heat pump with TES (HP-TES), which uses phase change materials (PCM). Heat pump charges TES by melting or freezing PCM during off-peak hours when there is no thermal demand from the building. TES is then discharged (i.e., by freezing or melting PCM) during peak hours to provide a more favorable heat source or heat sink for the heat pump to meet the thermal demand of the building with lower electricity use than conventional air-source heat pumps. Computer simulations were developed to predict the performance of HP-TES applied to a typical single-family house in the US. The building-level simulation results were scaled up to preliminarily assess the aggregated impacts of deploying HP-TES across all single-family houses in Texas of the United States, including reduction of peak demand of the electric grid.
Explore the source record for details and available documents.