Search NASA⌕ Search

SEARCH · Search NASA

Results for “aerosol calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Calibrator for Airborne Aerosol Probes (CAAP) Field Campaign Report

In this campaign, Calibrator for Airborne Aerosol Probes (CAAP), Mesa Photonics provided its U.S. Department of Energy (DOE) Small Business Innovation Research (SBIR) Phase II prototype of a portable, battery-powered monodisperse aerosol/droplet generator to field-calibrate two aerosol/cloud characterization instruments deployed on the DOE Atmospheric Radiation Measurement (ARM) Aerial Facility (AAF) ArcticShark uncrewed aerial system (UAS) during the flight campaign conducted at ARM’s Southern Great Plains (SGP) atmospheric observatory and the Blackwell-Tonkawa airfield (Oklahoma) in May 2024. The CAAP campaign (May 20-24, 2024) partially overlapped with the main ARM AAF campaign, Turbulent Layers Promoting New Particle Formation (NPFTURBULENCE, May 7-27, 2024, Gannet Hallar, principal investigator). The main goal of the CAAP campaign was field validation of calibration of aerosol and cloud probes deployed on the ArcticShark UAS. The campaign also provided an opportunity to test and evaluate the Mesa Photonics’ monodisperse aerosol/droplet generator prototype in the field, under real-life operational conditions.

54 ENVIRONMENTAL SCIENCES↗

Novel Calibration Approach for Monitoring Aerosol Hydrogen Isotopes Using Laser-Induced Breakdown Spectroscopy for Molten Salt Reactor Off-Gas Streams

Online monitoring is a key challenge for the continued development of molten salt reactor (MSR) technology. Laser-induced breakdown spectroscopy (LIBS) has previously been demonstrated to be a viable tool for monitoring aerosolized species and noble gases in real time, but the ability to discern varying isotopes in these streams has not yet been investigated for MSR applications. Tritium will form in MSRs from ternary fission and from (n,α)-reactions occurring in lithium-containing salts. This study compares three spectrometers of varying resolutions and types for measuring hydrogen isotope shifts in LIBS spectra of wetted filter paper. For each spectrometer, multivariate models were built (i.e., principal component regression, partial least squares regression, and multivariate curve resolution) to quantify the isotope ratio. The top models were then modified and corrected to apply the models to aerosol samples with varying isotope ratios. This novel calibration strategy offers an 82% reduction in volume of the calibration samples needed and is a more viable pathway for calibrating deployable LIBS systems. Lastly, this calibration model was compared with an all-aerosol trained model for monitoring hydrogen isotopes during a real-time test where the protium/deuterium ratio, along with representative salt species (i.e., lithium, sodium, and potassium) were adjusted dynamically. Results of this test validated the predictive capabilities of the transferred model and highlighted the capabilities of LIBS for real-time monitoring of MSR effluent streams.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Calibration of cloud and aerosol related parameters for solar irradiance forecasts in WRF-solar

Model parameters are a major source of uncertainty in numerical weather prediction. Recently, the Weather Research and Forecasting model with Solar extensions (WRF-Solar) has been upgraded by enhancing the treatment of sub-grid scale cloud and aerosols with augmentations of a sub-grid scale cloud scheme (CLD3) and an upgraded aerosol-aware Thompson-Eidhammer scheme (TE14). However, the value of model parameters associated with these parameterizations are assigned based on limited measurements or theoretical calculations. Calibrating the most sensitive parameters has the potential to improve solar irradiance predictions. Here, we adopted a multiobjective surrogate-based optimization (SBO) framework to calibrate nine parameters used in CLD3 and TE14 that lead to the largest sensitivity in simulated irradiance. The normalized mean-absolute-error (NMAE) of global horizontal irradiance (GHI) and direct normal irradiance (DNI) are minimized by calibrating WRF-Solar over two regions including the Southern Great Plains (SGP) and Central California, in order to focus on parameter calibration under cloudy conditions with different aerosol loading. The results show that generalized linear model (GLM)-based surrogate models approximate physical models well, particularly when the third order and three-way interaction terms are considered. The SBO framework efficiently searches the parameter space for optimal solutions with less computational costs than directly calibrating the physical model. We first calibrate CLD3 parameters over the less-polluted SGP region. Optimized CLD3 parameters alone result in NMAE reduction by 14% for the site-mean and up to 33% for individual cases over the SGP region. With further calibration of TE14 parameters over the Central California during active fire periods, the optimized parameters lead to over 20% reductions of NMAE. Our investigation reveals, however, that optimizing TE14 has a limited impact on irradiance simulations under less-polluted conditions in the SGP.

14 SOLAR ENERGY↗

Condensation Particle Counter (CPC) Instrument Handbook

The Model 3772 CPC is a compact, rugged, and full-featured instrument that detects airborne particles down to 10 nm in diameter, at an aerosol flow rate of 1.0 lpm, over a concentration range from 0 to 1x104 #/cc. This CPC is ideally suited for applications without high concentration measurements, such as basic aerosol research, filter and air-cleaner testing, particle counter calibrations, environmental monitoring, mobile aerosol studies, particle shedding and component testing, and atmospheric and climate studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Online monitoring of lanthanide species with combined spectroscopy in flowing aqueous aerosol systems

Combined spectroscopic analysis through absorption and laser-induced breakdown spectroscopy (LIBS) was used to monitor Nd and Pr concentrations in a flowing aqueous system. A unique, online sampling approach was employed that allowed for an approximately closed analysis loop of liquids from a reservoir. Absorption spectroscopy was performed with an optical flow cell, and LIBS was performed on an aerosol stream. Multivariate calibrations based on combined absorption and LIBS signals were built for Nd and Pr and then used to monitor concentrations in mixed solutions in a series of spiking tests. In these tests, the concentrations of Nd and Pr in solution were intermittently changed while spectroscopic signals were monitored in real-time. The combined spectroscopic signals and multivariate models were successful in monitoring changing concentrations of lanthanide species with high accuracy and minimal latency. Root-mean squared error of predictions were 0.015 mol L −1 and 0.019 mol L −1 for Nd and Pr respectively, and these lanthanides were able to be monitored to an accuracy of < 0.2 wt%. This work demonstrates both the capabilities of a sampling system for online analysis of liquids and the capabilities of multimodal spectroscopic characterization for real-time, continuous tracking of species in potentially hazardous liquid systems.

absorbance spectroscopy↗

Thermographic phosphor digital image correlation

The invention advances the ratio method of phosphor thermography using two machine vision cameras for full-field temperature measurements of a solid surface. As an example, algorithms from digital image correlation (DIC) can be used to determine the stereoscopic imaging system intrinsic and extrinsic parameters, and accurately register material points on the sample to subpixel locations in each image with 0.07 px or better accuracy. A phosphor calibration sample fabricated using aerosol deposition can be used for in situ determination of the temperature-versus-intensity ratio relationship. The full calibration methodology and several improvements on two-color phosphor thermography open the door for full-field temperature measurements in dynamic tests with deforming test specimens. In particular, thermographic phosphors can be combined with stereo digital image correlation in a novel diagnostic, TP+DIC, to measure time-resolved full-field surface strains and temperatures simultaneously, thereby enabling testing in combined thermo-mechanical environments.

Winters, Caroline↗

ARM Aerosol Measurement Science Group 2019 Strategic Planning Workshop Report

This report summarizes the results of a U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility workshop held in November 2019 to advance a science-based strategy for ARM’s aerosol measurement program. This was the second such workshop since the Aerosol Measurement Science Group (AMSG) was chartered in 2015 to enhance coordination of ARM observations of aerosols and atmospheric trace gases with the needs of ARM users. The results presented here reflect the AMSG’s focus in recent years on science-based strategies that will contribute to the increased use of ARM data to fulfill its mission of improving process representations and predictability in climate models. Sessions held during the workshop range from interfacing with models through aerosol sampling strategies to calibration protocols and data products. The AMSG workshops have been designed to recommend actions that will enable ARM to evolve and continue to meet its mission. To that end, the AMSG will develop an actionable plan from the recommendations outlined here. Some are well defined and can reasonably be accomplished in the short term. Others are less definite or of a larger scope that calls for a longer-term implementation. Further discussion will be required to develop and prioritize actionable items related to such areas. Task teams comprising the appropriate expertise and perspective from the AMSG and other members of the community will be formed to achieve this outcome. Some particular topics are recognized as high priority, so plans are underway to develop task teams and to hold follow-on discussions to address them. Four areas currently being considered for short, focused discussion are 1) aerosol measurements on the North Slope of Alaska, 2) improving data usability for modeling, 3) strategies for advancing remote sensing, vertical profiling, and distributed measurements of aerosols, and 4) aerosol sampling strategies at existing ARM sites to provide intensive modes of operation to promote data usage for process and modeling studies.

54 ENVIRONMENTAL SCIENCES↗

ARM Aerosol Measurement Science Group 2019 Strategic Planning Workshop Report

This report summarizes the results of a U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility workshop held in November 2019 to advance a science-based strategy for ARM’s aerosol measurement program. This was the second such workshop since the Aerosol Measurement Science Group (AMSG) was chartered in 2015 to enhance coordination of ARM observations of aerosols and atmospheric trace gases with the needs of ARM users. The results presented here reflect the AMSG’s focus in recent years on science-based strategies that will contribute to the increased use of ARM data to fulfill its mission of improving process representations and predictability in climate models. Sessions held during the workshop range from interfacing with models through aerosol sampling strategies to calibration protocols and data products. The strategies set forth here were also developed to be directly relevant to ARM’s updated Decadal Vision. The AMSG workshops have been designed to recommend actions that will enable ARM to evolve and continue to meet its mission. To that end, the AMSG will develop an actionable plan from the recommendations outlined here. Some are well defined and can reasonably be accomplished in the short term. Others are less definite or of a larger scope that calls for a longer-term implementation. Further discussion will be required to develop and prioritize actionable items related to such areas. Task teams comprising the appropriate expertise and perspective from the AMSG and other members of the community will be formed to achieve this outcome. Some particular topics are recognized as high priority, so plans are underway to develop task teams and to hold follow-on discussions to address them. Four areas currently being considered for short, focused discussion are 1) aerosol measurements on the North Slope of Alaska, 2) improving data usability for modeling, 3) strategies for advancing remote sensing, vertical profiling, and distributed measurements of aerosols, and 4) aerosol sampling strategies at existing ARM sites to provide intensive modes of operation to promote data usage for process and modeling studies.

54 ENVIRONMENTAL SCIENCES↗

Advances in phosphor two-color ratio method thermography for full-field surface temperature measurements

We report thermographic phosphors can be employed for optical sensing of surface, gas phase, and bulk material temperatures through different strategies including the time-decay method, time-integrated method, and frequency-domain method. We focus on the time-integrated method, also known as the ratio method, as it can be more practical in many situations. This work advances the ratio method using two machine vision cameras with CMOS detectors for full-field temperature measurements of a solid surface. A phosphor calibration coupon is fabricated using aerosol deposition and employed for in situ determination of the temperature-versus-intensity ratio relationship. Algorithms from digital image correlation are employed to determine the stereoscopic imaging system intrinsic and extrinsic parameters, and accurately register material points on the sample to subpixel locations in each image with 0.07 px or better accuracy. Detector nonlinearity is carefully characterized and corrected. Temperature-dependent, spatial non-uniformity of the full-field intensity ratio—posited to be caused by a blue-shift effect of the bandpass filter for non-collimated light and/or a wavelength-dependent transmission efficiency of the lens—is assessed and treated for cases where a standard flat-field correction fails to correct the non-uniformity. In sum, pixel-wise calibration curves relating the computed intensity ratio to temperature in the range of T = 300–430 K are generated, with an embedded error of less than 3 K. This work offers a full calibration methodology and several improvements on two-color phosphor thermography, opening the door for full-field temperature measurements in dynamic tests with deforming test articles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of methods for characterizing the fine particulate matter emissions from aircraft and other diffusion flame combustion aerosol sources

The U. S. Environmental Protection Agency in collaboration with the U. S. Air Force Arnold Engineering Development Complex conducted the VAriable Response In Aircraft nvPM Testing (VARIAnT) 3 and 4 test campaigns to compare nvPM emissions measurements from a variety of diffusion flame combustion aerosol sources (DFCASs), including a Cummins diesel engine, a diesel powered generator, two gas turbine start carts, a J85-GE-5 turbojet engine burning multiple fuels, and a Mini-CAST soot generator. The VARIAnT research program has conducted four test campaigns to date with the VARIAnT 3 and 4 test campaigns focusing on BC mass instrument performance, use of gas turbine engine sources for BC mass instrument calibration, and the characterization of the aerosols produced from the combustion sources. Results from both campaigns revealed agreement of about 20% between the AVL Micro-Soot Sensor, the Cavity Attenuated Phase Shift (CAPS PMSSA) monitor and the thermal-optical reference method for elemental carbon (EC), independent of the calibration source used. For the Artium LII-300, the measured mass concentrations in VARIAnT3 fall within 18% and in VARIAnT4 fall within 32% of the reference EC mass concentration when calibrated on a combustor rig in VARIAnT3 and on a LGT-60 start cart in VARIAnT4, respectively. It was also found that the three mass instrument types (MSS, CAPS PMSSA, and LII-300) can exhibit different BC to reference EC ratios depending on the emission source that appear to correlate to particle geometric mean mobility diameter, morphology, or some other parameter associated with particle geometric mean diameter (GMD) with the LII-300 showing a slightly stronger apparent trend with GMD. Systematic differences in LII-300 measured mass concentrations have been reduced by calibrating with a turbine combustion source (combustor or turbine engine). With respect to the particle size measurements made, the sizing instruments (TSI SMPS, TSI EEPS, and Cambustion DMS 500) were found to be in general agreement in terms of size distributions and concentrations with some exceptions. Teflon filter measurements of the total aerosol mass produced by the various DFCASs differed from the reference EC, BC, and integrated particle sized distribution measured aerosol masses. The Teflon filter measured mass was 30 to 40% greater than the reference EC and 50 to 60% greater than the BC mass for the J85 in both test campaigns. The measurements of particle size distributions and single particle analysis by miniSPLAT indicated the presence of large particles (>100 nm) having more compact morphologies, higher effective density, and a composition dominated by OC and ash. This increased large particle fraction is also associated with higher values of single scattering albedo measured by the CAPS PMSSA instrument and higher OC/EC measurements. These measurements indicate gas turbine engine emissions can be a more heterogeneous mix of particle types beyond the original E31 assumption that it is mainly composed of black carbon.

33 ADVANCED PROPULSION SYSTEMS↗

EPCAPE-PT-LANL Measurements: Condensation Particle Counter

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Condensational particle counter 3070 (TSI) Calibration: No calibration during the campaign. Files: data_10sec_CPC.csv, data_10min_CPC.csv Header: - NumberConcentration[/cm3]: Number concentration of aerosol particles measured by the CPC, expressed in particles per cubic centimeter. - NumberConcentration[/cm3]_QC: Number concentration of aerosol particles after quality control adjustments or filtering, expressed in particles per cubic centimeter. - QualityControl_Flag[bool]: A boolean flag indicating whether the measurement is flagged for quality control checks, (0=pass) - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement

54 ENVIRONMENTAL SCIENCES↗

Wet-radome attenuation in ARM cloud radars and its utilization in radar calibration using disdrometer measurements

Abstract. A relative calibration technique has been developed for the US Department of Energy's (DOE's) Atmospheric Radiation Measurement (ARM) user facility Ka-band ARM Zenith Radars (KAZRs). This method uses the signal attenuation caused by water on the radome to estimate reflectivity factor (Ze) offsets. The wet-radome attenuation (WRA) is assumed to follow a log-linear relationship with rainfall rate during light and moderate rain, as measured by a collocated surface disdrometer. The technique has an uncertainty of approximately 3 dB, due to factors such as disdrometer measurement error, rain variability between radar and disdrometer sample volumes, and the fitting function's uncertainty for the WRA behavior. A practical advantage of this WRA-based approach to shorter-wavelength radar monitoring is that, while it requires a reference disdrometer, it proves feasible for a wider range of collocated disdrometer measurements compared to traditional direct disdrometer comparison at the onset of light rain. This technique thus offers a cost-effective monitoring tool for remote or long-term radar deployments. This calibration technique was applied during the ARM Tracking Aerosol Convection Interactions Experiment (TRACER) from October 2021 through September 2022. The estimated Ze offsets were compared against traditional radar calibration and monitoring methods using available datasets from this campaign. Results show that the WRA-based offsets align closely with mean offsets found between cloud radars and from direct disdrometer comparison near the onset of rain, while also reflecting similar offset and campaign-long trends when compared to collocated, independently calibrated radar wind profilers. Nevertheless, overall, the KAZR Ze offsets estimated during TRACER remained stable at approximately 2 dB lower than the disdrometer estimates from the campaign start until the end of June 2022; afterward, the offsets increased to around 7 dB by the campaign's end. This increase is linked to a drop of about 1 dB in transmitter power toward the end of the project.

54 ENVIRONMENTAL SCIENCES↗