High Air-Flow Aerosol Filtration Testing

Pressure losses and aerosol collection efficiencies were measured for fibrous filter materials at air-flow rates consistent with high efficiency filtration (hundreds of cubic feet per minute). Microfiber filters coated with nanofibers were purchased and fabricated into test assemblies for a 12-inch duct system designed to mimic high efficiency filtration testing of commercial and industrial processes. Standards and specifications for high efficiency filtration were studied from a variety of institutions to assess protocols for design, testing, operations and maintenance, and quality assurance (e.g., DOE, ASHRAE, ASME). Three materials with varying Minimum Efficiency Reporting Values (MERV) were challenged with sodium chloride aerosol. Substantial filter loading was observed where aerosol collection efficiencies and pressure losses increased during experiments. Filter designs will be optimized and characterized in subsequent years of this study. Additional testing will be performed with higher hazard aerosols at Oak Ridge National Laboratory.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aerosol Filtration Efficiency of Common Fabrics Used in Respiratory Cloth Masks

The emergence of a pandemic affecting the respiratory system can result in a significant demand for face masks. This includes the use of cloth masks by large sections of the public, as can be seen during the current global spread of COVID-19. However, there is limited knowledge available on the performance of various commonly available fabrics used in cloth masks. Importantly, there is a need to evaluate filtration efficiencies as a function of aerosol particulate sizes in the 10 nm – 10 µm range, which is particularly relevant for respiratory virus transmission. We have carried out these studies for several common fabrics including cotton, silk, chiffon, flannel, various synthetics, and their combinations. While the filtration efficiencies for various fabrics when a single layer was used ranged from 5-80% and 15-95% for particle sizes <300 nm and >300 nm respectively, the efficiencies improved when multiple layers were used, and when using a specific combination of different fabrics. Filtration efficiencies of the hybrids (such as cotton-silk, cotton-chiffon, cotton-flannel) was >80 % (for particles <300 nm) and >90 % (for particles >300 nm). We speculate that the enhanced performance of the hybrids is likely due to the combined effect of mechanical and electrostatic-based filtration. Cotton, the most widely used material for cloth masks performs better at higher weave densities (i.e., threads per inch) and can make a significant difference in filtration efficiencies. Our studies also imply that gaps (as caused by an improper fit of the mask) can result in over a 60% decrease in the filtration efficiency, implying the need for future cloth mask design studies to take into account issues of “fit” and leakage, while allowing the exhaled air to vent efficiently. Overall, we find that combinations of various commonly available fabrics used in cloth masks can potentially provide significant protection against the transmission of aerosol particles.

36 MATERIALS SCIENCE↗

Optically assisted trapping with high-permittivity dielectric rings: Towards optical aerosol filtration

Controlling the transport, trapping, and filtering of nanoparticles is important for many applications. By virtue of their weak response to gravity and their thermal motion, various physical mechanisms can be exploited for such operations on nanoparticles. However, the manipulation based on optical forces is potentially most appealing since it constitutes a highly deterministic approach. Plasmonic nanostructures have been suggested for this purpose, but they possess the disadvantages of locally generating heat and trapping the nanoparticles directly on the surface. Here, we propose the use of dielectric rings made of high permittivity materials for trapping nanoparticles. Thanks to their ability to strongly localize the field in space, nanoparticles can be trapped without contact. We use a semianalytical method to study the ability of these rings to trap nanoparticles. Lastly, the results are supported by full-wave simulations and application of the trapping concept to nanoparticle filtration is suggested.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Alternative Materials for Mask Construction by the Public

N95 respirators became scarce to the general public in mid-to-late March of 2020 due to the SARS-CoV-2 epidemic. By mid-April of 2020, most states in the United States were requiring face coverings to be worn while in public enclosed places and in busy outdoor areas where groups of people were in close proximity. Many resorted to cloth masks, homemade masks, procedure masks obtained through online purchases, and other ad-hoc means. Thus, there was and still is a need to determine the aerosol filtration efficacy of commonly available materials that can be used for homemade mask construction. This study focused on non- woven polymeric fabrics that are readily available for homemade mask construction. The conclusion of this study is that non-woven materials that carry a high electric charge or those that can easily acquire charge had the highest aerosol filtration efficiency per unit of pressure drop. Future work should examine a wider variety of these materials and determine the maximum pressure drop that a nominal homemade mask can withstand before a significant portion of airflow is diverted around the mask. More broadly, a better understanding of the charge state on non-woven materials and impact of that charge state on filtration efficiency is needed.

36 MATERIALS SCIENCE↗

Filtration of bioaerosols using a granular metallic filter with micrometer-sized collectors

Several experimental studies with granular bed filters composed of micrometer-sized spherical or sintered metallic granules have demonstrated their use in aerosol filtration. However, the effectiveness of these metallic membrane filters against bioaerosols has not been established. In this work, the filtration efficiency and filter quality of these filters against airborne B. subtilis endospore and MS2 virus were determined as a function of face velocity and loading time. In experiments, a physical removal efficiency greater than 99.9% and a viable removal efficiency of greater than 5-log were observed for both bacterial spore and viral aerosols. A lower face velocity produced both higher collection efficiency and filter quality for virus but was not statistically significant for spore filtration. Although the filter had high filtration efficiency of the test bioaerosols, the filter's high pressure drop resulted in a low filter quality (0.25-0.75 kPa- 1). Overall, filters with micrometer-sized collectors capture bioaerosols effectively but their applications in aerosol filtration may be limited by their high pressure drop.

aerosol↗

Characterization and Analysis of Aerosol Particle Retention and Re-aerosolization from Hook-and-Loop Fasteners on the International Space Station

The extensive use of hook and loop fasteners aboard the International Space Station warrants careful examination of its contribution to indoor air pollution, as its fine fibers catch aerosol particles then re-aerosolize them upon being pulled apart, often within the breathing zone of astronauts. This problem is expanded by the lack of gravity because airborne particles larger than 1 micrometer do not settle. Instead these aerosols remain in the air until removed by filtration. Aerosol inhalation can have negative health effects, ranging from acute symptoms to long-term consequences, depending on particle sizes, mass and material composition. This study characterizes the size distribution, number concentration, and mass concentration of re-aerosolized debris generated by hook and loop fasteners taken from the stray light cover of the Microgravity Science Glovebox in the U.S. Laboratory of the ISS to understand the extent of its impact on air quality. Transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM), in conjunction with energy dispersive spectroscopy (EDS) were also used to characterize the morphology and composition of the particles.

Boyajian, Barbara↗

Filtration testing for enhanced performance of Radionuclide Monitoring Stations for Nuclear Treaty Verification

A study of aerosol filtration was conducted to improve U.S. Radionuclide Monitoring Station (RMS) performance for Nuclear Treaty Verification. The primary objectives of this study were to improve system operability and maintainability, reduce power consumption and operational cost, and reduce baseline radionuclide sensitivity. To meet these goals, Sandia National Laboratories (SNL) studied the performance of alternate filter materials and aerosol collection technologies that could be engineered into U.S. Radionuclide Monitoring Stations. Laboratory-scale filtration experiments were conducted with Filter Material 1, FM1 (current filter), Filter Material 2, FM2, and Filter Material 3, FM3. All three materials employ electrostatically charged filter fibers to enhance nanoparticle collection. FM2 and FM3 both had higher air permeability with respect to FM1 which is advantageous for high volume collection and power savings. Particle pre-charging, a well-established industrial technique used in electrostatic precipitators, was tested to see if electrostatically charging particles prior to filtration could enhance filter performance. We found that particle-pre-charging did enhance aerosol collection efficiencies for materials which would not have otherwise satisfied RMS performance requirements. Laboratory-scale testing indicated it may be possible to reduce the baseline radionuclide sensitivity to approximately 60% of its current value by increasing the volume of air sampled in 24 hours to 2.5 times the current air volume. Improvements to geolocation may also be possible with shorter air samples (e.g., 12 hours). A new methodology was developed at SNL to assess filter performance using established RMS certification procedures. We coined these tests “mid-scale” since they bridged the gap between laboratory-scale and full-scale RMS testing. Four filter specimens were drawn from the exact same atmospheric aerosol. Gamma spectroscopy was used to assess radiological backgrounds due to radon progeny and other naturally occurring radionuclides. Direct comparisons between the four filters allowed SNL to quantify the relative change in baseline sensitivity by altering air flow rate, filter material, and particle-pre charging. Mid-scale results agreed with laboratory-scale results: alterations to RMS configuration (filter, flow, and particle charge) may result in baseline sensitivities approximately 55-60% of their current values. Finally, an assessment of scalability was performed to determine if technical approaches used in laboratory-scale and mid-scale testing could be engineered into full-scale Radionuclide Monitoring Stations. Results suggested that particle-pre-charging is a viable technical approach if reductions in baseline sensitivity or power consumption are desired.

54 ENVIRONMENTAL SCIENCES↗

The reactive bed plasma system for contamination control

The contamination control capabilities of the Reactive Bed Plasma (RBP) system is described by delineating the results of toxic chemical composition studies, aerosol filtration work, and other testing. The RBP system has demonstrated its capabilities to decompose toxic materials and process hazardous aerosols. The post-treatment requirements for the reaction products have possible solutions. Although additional work is required to meet NASA requirements, the RBP may be able to meet contamination control problems aboard the Space Station.

Birmingham, Joseph G.↗

Quaternary ammonium salt coated air filter for bioaerosol removal from building indoor air

Developing air filters with biocidal ability is important to protect the public from infectious respiratory diseases. A simple spray-coating approach was devised to fabricate antimicrobial air filters to remove bioaerosols. Here, the commercial antimicrobial agent Goldshield 75 was coated on the air filters through covalent immobilization, endowing the fabricated filter with long-lasting biocidal ability. All coated filters significantly inhibited both Gram-positive bacteria (Micrococcus luteus) and Gram-negative bacteria (Escherichia coli). The antibacterial ability of the coated filters is similar to the commercial AeraSafe antibacterial filter. The coated filter showed over 99.9 % antibacterial efficiency 3 months after the application of the coating. Both bacterial and virus filtration efficiencies of coated charged polypropylene filter were higher than 99.9 %. The coating did not have much effect on the NaCl aerosol filtration efficiency of the filters. This simple spray-coating strategy is a practical method for producing antimicrobial air filters for the prevention of infectious respiratory diseases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Filtration Performance of Layering Masks and Face Coverings and the Reusability of Cotton Masks after Repeated Washing and Drying

In this study, filtration efficiency of different respirators, face masks, and a 2-ply cotton handkerchief bandana was compared for particles in the size range of 60 nm-4 um under a "perfect fit" condition. The filtration efficiency at the most penetrating particle size of 0.3 um on average ranged from 83-99% for N95 and KN95 respirators, 42-88% for surgical masks, 16-23% for cloth masks, and 9% for bandana. We also investigated the effects of using double surgical masks or layering a cloth mask over various surgical masks in terms of their filtration characteristics. In most of these combinations, the filtration efficiency improved by ~25% for particles 0.3-1 um in diameter without any substantial change in the filter quality factor when compared to the highest of the individual mask results. To investigate the reusability of cotton cloth masks, 2-layer cotton fabric sample coupons were machine washed and dried for 52 cycles leading to an increase in inhalation resistance (~20 Pa) without affecting size-resolved filtration efficiency. Scanning electron microscopy revealed that washing and drying led to the gradual deconstruction of cotton fibers at the scale of several micrometers to hundreds of nanometers in the form of delamination of the fiber wall and fibrillation of the nanofiber constituents. Results indicate that cloth masks may be layered over surgical masks for additional benefits, and that cloth masks made out of cotton fabric can be washed and reused numerous times without a significant loss in filtration efficiency.

99 GENERAL AND MISCELLANEOUS↗

Testing of the ISS’s Charcoal HEPA Integrated Particle Scrubber (CHIPS) Filters to Ascertain an Efficiency Curve and Most Penetrating Particle Size

High air quality is a top priority in hermetically sealed environments, such as the International Space Station (ISS). Aerosol particulate filtration on the ISS is achieved via 21 HEPA filters. Traditional HEPA filters have an efficiency of 99.97%, but HEPA filters aboard the ISS have been found to achieve 99.99% efficiency. This may be due to the flight-grade HEPA filters chosen or, less likely, that they are combined with activated charcoal filters for siloxane removal in a combination referred to as Charcoal HEPA Integrated Particle Scrubbers (CHIPS) filters. All filters have a Most Penetrating Particle Size (MPPS), but, until now, the MPPS and efficiency curve of the CHIPS filters was not known. The efficiency curve of the CHIPS filters was ascertained at NASA Glenn Research Center through standard salt crystal aerosolization. This method was selected over aerosolized oil droplets due to a desire to preserve the filter’s function for further testing. The CHIPS filters were tested as they are oriented on the ISS (activated charcoal filter followed by a flight-grade HEPA filter), with the HEPA portion alone, and with the activated charcoal portion alone. The results of this experiment are generally useful but can be especially useful for the microbiology and Environmental Control and Life Support Systems (ECLSS). This is due to microbial contamination being a potential concern in the air revitalization systems on the ISS. Knowing the MMPS of the CHIPS filters, in conjunction with levels of airborne microbes, is useful for predicting which and how many microbes are likely to get through the HEPA filters that sit in the beginning of the ISS airstream. It may also be useful to other groups at NASA to know how many particulates are able to pass through high-efficiency filtration, and even for healthcare cleanrooms and other air purification pursuits.

A Nicolas Whitlock↗

Fuel Efficient Diesel Particulate Filter (DPF) Modeling and Development

The project described in this report seeks to promote effective diesel particulate filter technology with minimum fuel penalty by enhancing fundamental understanding of filtration mechanisms through targeted experiments and computer simulations. The overall backpressure of a filtration system depends upon complex interactions of particulate matter and ash with the microscopic pores in filter media. Better characterization of these phenomena is essential for exhaust system optimization. The acicular mullite (ACM) diesel particulate filter substrate is under continuing development by Dow Automotive. ACM is made up of long mullite crystals which intersect to form filter wall framework and protrude from the wall surface into the DPF channels. ACM filters have been demonstrated to effectively remove diesel exhaust particles while maintaining relatively low backpressure. Modeling approaches developed for more conventional ceramic filter materials, such as silicon carbide and cordierite, have been difficult to apply to ACM because of properties arising from its unique microstructure. Penetration of soot into the high-porosity region of projecting crystal structures leads to a somewhat extended depth filtration mode, but with less dramatic increases in pressure drop than are normally observed during depth filtration in cordierite or silicon carbide filters. Another consequence is greater contact between the soot and solid surfaces, which may enhance the action of some catalyst coatings in filter regeneration. The projecting crystals appear to provide a two-fold benefit for maintaining low backpressures during filter loading: they help prevent soot from being forced into the throats of pores in the lower porosity region of the filter wall, and they also tend to support the forming filter cake, resulting in lower average cake density and higher permeability. Other simulations suggest that soot deposits may also tend to form at the tips of projecting crystals due to the axial velocity component of exhaust moving down the filter inlet channel. Soot mass collected in this way would have a smaller impact on backpressure than soot forced into the flow restrictions deeper in the porous wall structure. This project has focused on the development of computational, analytical, and experimental techniques that are generally applicable to a wide variety of exhaust aftertreatment technologies. By helping to develop improved fundamental understanding pore-scale phenomena affecting filtration, soot oxidation, and NOX abatement, this cooperative research and development agreement (CRADA) has also assisted Dow Automotive in continuing development and commercialization of the ACM filter substrate. Over the course of this research project, ACM filters were successfully deployed on the Audi R10 TDI racecar which won the 24 Hours of LeMans endurance race in 2006, 2007, and 2008; and the 12 Hours of Sebring endurance race in 2006 and 2007. It would not have been possible for the R10 to compete in these traditionally gasoline-dominated events without reliable and effective exhaust particulate filtration. These successes demonstrated not only the performance of automotive diesel engines, but the efficacy of DPF technology as it was being deployed around the world to meet new emissions standards on consumer vehicles. During the course of this CRADA project, Dow Automotive commercialized their ACM DPF technology under the AERIFYTM DPF brand.

33 ADVANCED PROPULSION SYSTEMS↗

Development of Test Protocols for International Space Station Particulate Filters

Air quality control on the International Space Station (ISS) is a vital requirement for maintaining a clean environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of gravitational settling. The ISS Environmental Control and Life Support System (ECLSS) uses a filtration system that has been in use for over 14 years and has proven to meet this challenge. The heart of this system is a traditional High- Efficiency Particulate Air (HEPA) filter configured to interface with the rest of the life support elements and provide effective cabin filtration. Over the years, the service life of these filters has been re-evaluated based on limited post-flight tests of returned filters and risk factors. On earth, a well designed and installed HEPA filter will last for several years, e.g. in industrial and research clean room applications. Test methods for evaluating these filters are being developed on the basis of established test protocols used by the industry and the military. This paper will discuss the test methods adopted and test results on prototypes of the ISS filters. The results will assist in establishing whether the service life can be extended for these filters. Results from unused filters that have been in storage will also be presented to ascertain the shelf life and performance deterioration, if any and determine if the shelf life may be extended.

Aerosol↗

Filter Efficiency and Pressure Testing of Returned ISS Bacterial Filter Elements (BFEs)

The air quality control equipment aboard the International Space Station (ISS) and future deep space exploration vehicles provide the vital function of maintaining a clean cabin environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of sedimentation. The ISS Environmental Control and Life Support (ECLS) system architecture in the U.S. Segment uses a distributed particulate filtration approach consisting of traditional High-Efficiency Particulate Air (HEPA) filters deployed at multiple locations in each U.S. Seg-ment module; these filters are referred to as Bacterial Filter Elements, or BFEs. In our previous work, we presented results of efficiency and pressure drop measurements for a sample set of two returned BFEs with a service life of 2.5 years. In this follow-on work, we present similar efficiency, pressure drop, and leak tests results for a larger sample set of six returned BFEs. The results of this work can aid the ISS Program in managing BFE logistics inventory through the stations planned lifetime as well as provide insight for managing filter element logistics for future exploration missions. These results also can provide meaningful guidance for particulate filter designs under consideration for future deep space exploration missions.

ISS Air Quality↗