Proposal for New Plant Controller and Electrical Controller

This is the first revision of this memo capturing in more detail some items discussed at the last WECC MVS meeting in January, 2022 during the REMWG part of the meeting. The items here are presented for further enhancements in the electrical controls model and plant controller model (specifically for hybrid-plants or plants with multiple aggregated inverter-based generation models). These will need to be discussed and refined, and then implemented for benchmark testing and final approval.

42 ENGINEERING↗

Aggregated DER_A Model Parameterization via Online Moving Horizon Estimation

Here, this paper introduces a methodology for parameterizing the DER_A model using a novel smooth mathematical representation, simplifying the process and preserving accuracy in modeling inverter-based generator (IBG). The methodology employs an online parameterization process that can operate in real-time. The model parameterization process is structured into five sequential steps, each targeting a specific aspect of the DER_A model through moving horizon estimation. This approach adapts to systems with varying voltage and frequency support requirements by selectively applying each step. Simulation results on systems with both known and unknown parameters validate the methodology’s effectiveness. The online moving horizon estimation technique accurately captures the dynamics of the overall system and ensures that the parameterized DER_A model closely mirrors the real system’s voltage, current, and power dynamics. The findings highlight the potential of this methodology to substantially improve and simplify the dynamic modeling of power systems, paving the way for more reliable and robust IBG and grid integration.

42 ENGINEERING↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Final Report)

The AGGREGATE project team successfully developed and validated various modules for outage management. Brief summaries of each module are provided to showcase their strength for outage management and restoration for a distribution system with a high penetration of connected distribution energy resources (DERs). In recent years, inverter-based DERs have been widely deployed in distribution system. A most of behind-the-meter (BTM) solar power generation is not visible to the utility. The data-driven DER and load estimation modules are using machine learning (ML) and artificial intelligence (AI) to manage this issue, which provides an opportunity for distribution system operators (DSOs) to operate systems and make decisions in real-time for a distribution system with a high penetration of DERs deployed. Also, the estimated DER and true load can be further leveraged in network aggregation and cold-load pick up estimation for reducing the computing complexity and providing for fast restoration. After load demand and DER power generations have been estimated, the information will support topology and state estimation (SE). The topology estimation module demonstrated the viability of mixed integer linear programming (MILP) formulation to estimate the most likely operational radial topology and outage sections using power flow measurements, historical/estimated load and DERs data and smart meter ping measurements. Formulation includes continuous (power flow, load and DERs data) and binary measurements (smart meter ping measurements) in a single formulation. Errors in continuous data and binary data are modeled as normal distribution and Bernoulli distribution, respectively. In the future distribution grid, the power injection from controllable DERs will be essential for efficient and resilient grid operation. However, determining the optimal DER injections and restoration actions is dependent on knowledge of the system states. State estimation (SE), already the cornerstone of transmission energy management systems, will become commonplace in distribution management systems as more measurements become available from deployment of automated metering infrastructure (AMI). Observability analysis is the first step in SE, as it determines the sufficiency of the available measurements for accurately estimating the current system states. A new type of pseudo-measurement called a Correlational Measurement (CM) is introduced in this module, to enhance the observability of the system to enable more accurate SE. CMs encapsulate knowledge of correlation between demand patterns for similar classes of loads as well as injection patterns for same-technology renewable DERs. During grid contingency scenarios, DERs have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid’s restoration after an adverse event and hence enhance resilience. The controllability module proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in power electronics interfaced DERs for mitigating voltage problems. In a resilience mode without the utility system, the distribution grid relies on DERs to serve critical load. In such a severe event with multiple faults on the distribution feeders, actuation of various protective devices (PDs) divides the distribution system into electrical islands. The undetected actuated PDs due to fault current contributions from DERs can delay the restoration process, thereby reducing the system resilience. The Advanced Outage Management (AOM) and the Advanced Feeder Restoration (AFR) modules developed in this project provide improved system resilience with multiple DERs. AOM identifies the faulted sections and actuated PDs in a distribution system with DERs by incorporating smart meter data. The most credible outage scenario including fault locations, PD actuations, and fault indicator (FI) failures is identified by a set of binary integer linear programming incorporating hypotheses. The AFR module serves to restore a distribution system with available energy resources taking into consideration the availability of utility sources and DERs. By partitioning the system into islands, critical load will be served with the available generation resources within islands based on the solution of a MILP. When the utility systems become available, the optimal path will be determined by a spanning tree search algorithm that reconnects these islands back to substations and restores the remaining load. The transmission and distribution (T&D) co-simulation module was used to validate the effect of a control action performed on the distribution side assets as it propagates to the transmission side. This ensures that the control action performed results in a feasible operating point on both the transmission and the distribution system. In addition to validation, the team used the T&D co-simulation module to demonstrate how distribution system assets can be used to mitigate issues on the transmission system. Specifically, the team demonstrated that appropriate switching operations on the distribution side can alleviate the line overload condition on the transmission side without causing new operational constraint violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency Support From Electric Vehicles for Advancing Renewable Energy Integration

The integration of renewable energy resources (RERs) in the modern power grid is increasing rapidly because of aggressive decarbonization goals, lower costs, and increased government investment. However, higher penetrations of inverter-based generation can lead to frequency stability issues because of reduced system inertia. This paper develops a framework for quantifying the contribution of electric vehicles (EVs) toward providing frequency support to the grid and thus increasing the penetration limit of renewable energy resources (RERs). EVs are considered to provide both inertial response and primary frequency response support to the grid. A stochastic approach incorporating the uncertainties associated with the behavior of EVs is developed to derive the discharge limit of EV aggregators. A multi-machine system frequency response (MM-SFR) model is developed, which incorporates the dynamic virtual inertia and droop coefficients of EV aggregators derived from the EV control modules. Frequency security constraints are developed from this MM-SFR model, which, along with the converter voltage security and low voltage ride-through constraints, are integrated within a nonlinear optimization framework to determine the RER integration limit. Here, the efficacy of the proposed approach is validated using the RTS-GMLC test system.

25 ENERGY STORAGE↗

Inverter-Based Operation of Maui: Electromagnetic Transient Simulations

As larger and larger power systems approach and reach 100% inverter-based resource (IBR) operation during some hours of the year, questions arise regarding the stability of such extremely-high IBR power systems, the potential need for grid-forming (GFM) inverter technology, and the potential need for synchronous condensers. Relatedly, questions also arise about the ability of conventional positive sequence power system modeling tools to capture high-IBR system dynamics. This presentation introduces electromagnetic transient (EMT) simulations in PSCAD of the near-future (year 2023) Maui power system at and near 100% IBR operation and compares those simulations to positive sequence (PSSE) simulations. The Maui PSCAD model is parallelized on 30 cores and includes the entire transmission system (>200 three-phase buses), >170 individual and aggregate IBR models, four wind plants, and three synchronous generators plus six synchronous condensers at two locations. We investigate system stability with varying levels of inertia using conventional grid-following IBR controls, and then we investigate the impact of GFM controls on stability. Results suggest that: 1) positive sequence simulations can miss key dynamics in extremely high IBR cases; 2) EMT simulations can also miss key dynamics if inverter inner control dynamics are not modeled; 3) synchronous condensers can stabilize a system in which 100% of the energy is supplied by IBRs, even conventional grid-following IBRs; 4) GFM controls on just some of the IBRs can stabilize a 100% IBR power system, even if that system has zero inertia (i.e. no synchronous condensers, though synchronous condensers may be needed for other purposes such as protection system operations).

41 EE - Solar Energy Technologies Office (EE-4S)↗

Electromagnetic Transient (EMT) Simulation Algorithm for Evaluation of Photovoltaic (PV) Generation Systems

Use of inverter-based resources facilitating renewable energy resources such as photovoltaic (PV) generation is increasing rapidly with decreasing costs and reduced emissions associated. To accommodate such rapid growth of inverter-based resources like PV systems, electromagnetic transient (EMT) simulation models of both PV systems and grids are required to analyze the interaction of PVs in the grid (like the post-event analysis). In addition, the EMT simulation would help with the planning of future power grid with a large number of PVs as well as other inverter-based distributed generation systems. In this paper, the EMT simulation models of PV systems and grids are developed based on the differential algebraic equations (DAEs) representing their EMT dynamics. Furthermore, advanced simulation algorithms including numerical stiffness-based hybrid discretization, DAE clustering and aggregation, multi-order integration, and matrix splitting approaches are applied to accelerate the EMT simulation. The proposed algorithm was applied to 125 PV inverters within 52-bus medium-voltage (MV) distribution grid.

Choi, Jongchan↗

An Energy Service Interface for Distributed Energy Resources

Renewable energy resources, particularly wind and solar photovoltaic, are becoming significant contributors to electric power generation. These re-sources will contribute towards achieving sustainable electric power systems. However, renewable resources will dramatically increase the demand for flexible power system operations. This paper proposes an energy service interface that will allow aggregated distributed energy resources, such as residential loads and inverter-based systems, to participate in NERC-defined smart energy reliability services. Such cyber-physical systems will increase system flexibility by ensuring match between energy supply and energy demand.Aggregation and coordinated dispatch of millions of distributed energy resources will require development of large-scale computing networks. Several smart grid interface-enabling technologies, including IEEE 2030.5, Common Smart Inverter Profile, SunSpec Modbus, and CTA 2045, are discussed. Residential loads are categorized by their static and dynamic energy characteristics to identify services in which they can participate. The business model for the energy services interface as well as probabilistic modeling for resource estimation are highlighted as future considerations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive Protection and Validated Models to Enable Deployment of High Penetrations of Solar PV (PV-MOD)

The availability and validation of various PV models in commercial tools differ, with some models not yet thoroughly validated for advanced inverter functionalities and reliable performance under weak system conditions. Many existing models do not fully incorporate new inverter control functions, which can affect system stability. The increasing deployment of solar PV and other inverter-based resources (IBRs), including distributed energy resources (DERs), is influencing the reliable operation of protection schemes in distribution systems and microgrids. Emerging adaptive protection schemes (APS) offer new opportunities for protecting these systems during varying configurations and DER operating conditions, though their demonstration and validation remain limited. Adaptive protection schemes face similar challenges, as they are typically designed for specific configurations. There is a growing need for tools and methodologies to streamline the deployment of adaptive protection for safe and reliable DER integration. The project main objective was to develop and validate high-fidelity generic models of solar PV facilities for stability, protection, EMT, and QSTS analyses. This objective was achieved, and these models can now be integrated into commercial software tools, enabling utilities, vendors, and developers to study high-penetration PV systems more confidently. The project also demonstrated advanced applications of these models, including the design and deployment of adaptive protection schemes in high-penetration field applications and microgrids, supporting grid safety and reliability. Several milestones were reached by the end of the project. A sophisticated inverter test plan was developed, and inverters representative of the North American marketplace were selected. EPRI and NREL tested various inverters, conforming to IEEE standards. Improvements were made to existing generic models of IBR units, IBR plants, and aggregated feeders for various analyses. The first generic electromagnetic transient (EMT) model for a solar PV plant was developed, conforming to IEEE Std 2800™-2022 and validated against laboratory measurements of a 2.2 MVA large-scale battery energy storage system (BESS) inverter. That model was then used to produce reference responses illustrating examples of validated and verified IBR plant models that pass or fail tests for technical minimum capability and performance as specified in the IEEE standard. The developed, tested, and validated generic models can be used for transmission planning, stability assessments, expansion planning, and evaluating potential future IBR interconnection requirements. They can also support interconnection screens and conformity assessments of IBR plants, including solar PV. The project significantly contributed to the ongoing standardization and model-based representation and verification of IBR responses. The project further addressed challenges of common distribution protection schemes with increasing deployment of DER by developing, validating, and demonstrating adaptive protection schemes (APS) that can improve the reliable and safe integration of DER into distribution systems. New APS were designed using improved DER models for three common distribution systems: a radial feeder, a meshed network, and a microgrid. Modeling and hardware-in-the-loop (HIL) testing of the APS were conducted, successfully showing their effectiveness and selectivity. Proof-of-concept field demonstration was achieved for two APS, i.e., one on a radial feeder and another one in a microgrid. Field demonstration could not be achieved for the APS on a meshed network, primarily due apprehension of one utility partner and also due to limited access to the protective algorithms in the network protectors. Guidelines developed from the lessons learned in the project lay out the general process followed in the design, installation, and commissioning of APS for various distribution systems. Distribution utility partners’ apprehension about field demonstration of the new APS were addressed—with varying success—by taking a stepped risk-management approach of modeling of a wide range of sensitivities first, performing in-depth proof-of-concept testing in the laboratory including HIL next, and finally deliberately implementing and commissioning the actual protection equipment and algorithms into parts of—or in parallel operation to—the three real distribution systems. Future work should include pilot projects that further show the acceptable performance of the developed APS before these schemes be rolled out more widely. Inclusion of both utility and original equipment manufacturers (OEMs) in future projects could increase chances of successful field demonstration. Despite challenges in achieving the field demonstration goal of the project for all three APS, the research significantly contributed to the innovation of adaptive protection solutions for scalable and reliable DER integration into distribution systems. This project significantly enhances the understanding of the impact of using appropriate inverter models on distribution and transmission (T&D) systems. By addressing the limitations of existing generic models, the project introduces high-fidelity models for stability, protection, electromagnetic transient (EMT), and quasi-static time series (QSTS) analyses. These models, integrated into commercial software tools, enable utilities, vendors, and developers to confidently study high-penetration PV systems. The project also demonstrates advanced applications, including adaptive protection schemes (APS) for distribution systems and microgrids, ensuring grid safety and reliability. The technical effectiveness and economic feasibility of the methods are evident through the development and validation of sophisticated inverter test plans and the selection of representative inverters. Testing by EPRI and NREL on retail, commercial, and utility-scale inverters, conforming to IEEE standards, underscores the robustness of the models. Improvements to existing generic models for various analyses further enhance their validity and applicability. The project also identifies gaps in common distribution protection schemes and designed new APS using improved DER models, demonstrating their effectiveness through modeling and hardware-in-the-loop (HIL) testing. The project’s benefits to the public are manifold. By advancing the standardization and model-based representation of IBR response, it supports transmission planning, stability assessments, and future IBR interconnection requirements. The generic models can facilitate better communication between transmission planners and developers, supporting expected IBR plant capability and performance. Additionally, the development of APS for radial feeders, meshed networks, and microgrids supports the integration of distributed energy resources (DERs) into distribution systems, enhancing grid reliability and safety. The project’s emphasis on thorough testing and simplicity in design ensures practical and scalable solutions for DER integration.