Wind-Tunnel Tests of a 1/6-Scale Model of Republic XF-12 Vertical Tail Incorporating a De-Icing Air Duct

A 1/6-scale model of the Republic XF-12 vertical tail with stub fuselage, stub horizontal tail, and a de-icing air duct was tested in the Langley stability tunnel. The investigation consisted of a study of the effects of the duct, with and without air flow, on the aerodynamic characteristics of the model. The model tested was a revision of a model previously tested in the Langley stability tunnel. The revised model differed from the original model in that it incorporated a de-icing air duct, included a dorsal fin, and had a larger stub fuselage. A comparison of data obtained form tests of the original and revised models was made. The results of the investigation indicated that the air duct had very little effect on the aerodynamic characteristics of the model. A small change occurred in the variation of rudder hinge-moment coefficient with angle of attack but it is believed that this change can be corrected by a properly applied spring tab.

MacLachlan, Robert↗

Low-noise flow valve for air ducts

Valve assembly controls air flow from feeder into main duct, with minimum of turbulence, friction, pressure differential, and noise. Valve consists of damper, deflector, and spring. Streamlining of damper and deflector merges flow smoothly, while spring keeps damper and deflector in contact and eliminates valve chatter and damping vibrations.

Gallo, E. A.↗

Wind-Tunnel Investigation of Rectangular Air-Duct Entrances in the Leading Edge of an NACA 23018 Wing, Special Report

A preliminary investigation of a number of duct entrances of rectangular shape installed in the leading edge of a wing was conducted in the NACA 20-foot tunnel to determine the external drag, the available pressure, the critical Mach numbers, and the effect on the maximum lift. The results showed that the most satisfactory entrances, which had practically no effect on the wing characteristics, had their lips approximately in the vertical plane of the leading edge of the wing. This requirement necessitated extending the lips outside the wing contour for all except the small entrances. Full dynamic pressure was found to be available over a fairly wide range of angle of attack. The critical Mach number for a small entrance was calculated to be as high as that for the plain wing but was slightly lower for the larger entrances tested.

Biermann, David↗

Vortex Shedding Inside a Baffled Air Duct

Common in the operation of both segmented and un-segmented large solid rocket motors is the occurrence of vortex shedding within the motor chamber. A portion of the energy within a shed vortex is converted to acoustic energy, potentially driving the longitudinal acoustic modes of the motor in a quasi-discrete fashion. This vortex shedding-acoustic mode excitation event occurs for every Reusable Solid Rocket Motor (RSRM) operation, giving rise to subsequent axial thrust oscillations. In order to better understand this vortex shedding/acoustic mode excitation phenomena, unsteady CFD simulations were run for both a test geometry and the full scale RSRM geometry. This paper covers the results from the subscale geometry runs, which were based on work focusing on the RSRM hydrodynamics. Unsteady CFD simulation parameters, including boundary conditions and post-processing returns, are reviewed. The results were further post-processed to identify active acoustic modes and vortex shedding characteristics. Probable locations for acoustic energy generation, and subsequent acoustic mode excitation, are discussed.

Davis, Philip↗

Automatic air flow control in air conditioning ducts

Device is designed which automatically selects air flow coming from either of two directions and which can be adjusted to desired air volume on either side. Device uses one movable and two fixed scoops which control air flow and air volume.

Obler, H. D.↗

Dynamic response characteristics of a circulation control rotor model pneumatic system

Numerical and experimental simulation of unsteady airflow through the control valve and slotted air duct of a circulation control rotor is described. The numerical analysis involves the solution of the quasi-one-dimensional compressible fluid-dynamic equations in the blade air duct together with the coupled isentropic flow equations for flow into the blade through the valve and out of the blade through the Coanda slot. Numerical solutions are compared with basic experimental results obtained for a mockup of a circulation control rotor and its pneumatic valving system. The pneumodynamic phenomena that were observed are discussed with particular emphasis on the characteristic system time lags associated with the response of the flow variables to transient and periodic control valve inputs.

Watkins, C. B.↗

Supplementary Free-Spinning-Tunnel Investigation of a 1/30-Scale Model of the Grumman XF10F-1 Airplane in the Swept-Wing Configuration with Slats Extended

A supplementary investigation has been conducted in the Langley 20-foot free-spinning tunnel of a 1/30 -scale model of the Grumman XFlOF-1 airplane to determine what effect full-span slats would have on the spin-recovery characteristics of the swept-wing version of the XFlOF-1 airplane, which had previously been indicated as possessing undesirable spin-recovery characteristics without slats. The effects of extended nose-wheel doors and of fairing the air-duct inlets were also determined. The results indicated that, with slats fully extended, satisfactory recovery could be obtained by rudder reversal provided it was accompanied by movement of the trimmer ailerons to full with the spin (only up-going spoiler operative), Extension of the nose-wheel doors or fairing of the air-duct inlets did not improve the recovery characteristics.

Berman, Theodore↗

Solar Heating System installed at Belz Investment Company, Memphis, Tennessee

A hot air solar system which utilizes flat plate air collectors is discussed. Collector areas for each of four buildings cover 780 sq ft, with storage capacity of 390 cu ft per building. The air system has a special air handling unit to move air through the collectors and into and out of the rock storage, with connection to the air duct distribution system. The heat of the motor is added to the heat delivered to the system. The solar system also includes four motorized special low leakage dampers and two gravity fabric dampers. The system is automatically controlled by a solid state controller with three thermistors: one located in the collectors, one in the rock box to plenum, one in the return air duct from the heated space. A three stage heating thermostat, located in the conditioned space, controls the operation.

Source record↗

Stability of Enclosed Laminar Flames Studied in Microgravity

In practical combustion systems, the flame is often anchored at the inlet where the fuel is injected into an air duct. This type of system is found in powerplant combustors, gas turbine combustors, and the jet engine afterburner. Despite its successful use, this configuration is vulnerable to adverse flow conditions that can cause the flame to literally lift off from the inlet or even blowout. Poor flame stability is, of course, unwanted, especially where safety has a high priority. Our understanding of the mechanisms that control flame stability is incomplete in part because the interaction of buoyant (i.e., gravity-induced) convection makes it difficult to interpret normal-gravity results. However, a comparison of normal-gravity and microgravity results can provide a clear indication of the influence of forced and buoyant flows on flame stability. Therefore, a joint microgravity study on the stability of Enclosed Laminar Flames (ELF) was carried out by researchers at The University of Iowa and the NASA Lewis Research Center. The microgravity tests were conducted in the Microgravity Glovebox (MGBX), during the STS-87 space shuttle mission in late 1997, using hardware designed and produced at Lewis. The primary objective of the ELF investigation was to determine the mechanisms controlling the stability of round, laminar, gas-jet diffusion flames in a coflow air duct. The study specifically focused on the effect of buoyancy on the flame characteristics and velocities at the lift-off, reattachment, and blowout of the flame. When the fuel or air velocity is increased to a critical value, the flame base abruptly jumps downstream, and the flame is said to have reached its lift-off condition. Flow conditions are such that the flame cannot be maintained at the burner rim despite the presence of both fuel and oxygen. When the velocity is further increased, the flame eventually extinguishes at its blowout condition. In contrast, if the velocity is reduced, the flame base eventually returns to anchor at the burner rim, at a velocity lower than that of lift-off, indicating a hysteresis effect.

Stocker, Dennis P.↗

Aircraft Ducting

Templeman Industries developed the Ultra-Seal Ducting System, an environmental composite air duct with a 50 percent weight savings over current metallic ducting, but could not find a commercial facility with the ability to test it. Marshall Space Flight Center conducted a structural evaluation of the duct, equivalent to 86 years of take-offs and landings in an aircraft. Boeing Commercial Airplane Group and McDonnell Douglas Corporation are currently using the ducts.

Source record↗

Solar energy system performance evaluation report for Solaron-Duffield, Duffield, Virginia

The Solaron Duffield Solar Energy System was designed to provide 51 percent of the space heating, and 49 percent of the domestic hot water (DHW) to a two story 1940 square foot area residence using air as the transport medium. The system consists of a 429 square foot collector array, a 265 cubic foot rock thermal storage bin, heat exchangers, an 80 gallon DHW preheat tank, pumps, blowers, controls, air ducting and associated plumbing. A air-to-liquid heat pump coupled with a 1,000gallon water storage tank provides for auxiliary space heating and can also be used for space cooling. A 52 gallon electric DHW tank using the solar preheated water provides domestic hot water to the residence. The solar system, which became operational July 1979, has the following modes of operation: First Stage: (1) collector to storage and DHW; (2)collector to space heating; (3) storage to load. Second Stage: (4) heat pump auxiliary direct; (5) auxiliary heat from heat pump storage. Third Stage: (6) electrical resistance (strip) heat.

Source record↗

International Space Station USOS Crew Quarters Ventilation and Acoustic Design Implementation

The International Space Station (ISS) United States Operational Segment (USOS) has four permanent rack sized ISS Crew Quarters (CQ) providing a private crewmember space. The CQ uses Node 2 cabin air for ventilation/thermal cooling, as opposed to conditioned ducted air from the ISS Temperature Humidity Control System or the ISS fluid cooling loop connections. Consequently, CQ can only increase the air flow rate to reduce the temperature delta between the cabin and the CQ interior. However, increasing airflow causes increased acoustic noise so efficient airflow distribution is an important design parameter. The CQ utilized a two fan push-pull configuration to ensure fresh air at the crewmember s head position and reduce acoustic exposure. The CQ interior needs to be below Noise Curve 40 (NC-40). The CQ ventilation ducts are open to the significantly louder Node 2 cabin aisle way which required significantly acoustic mitigation controls. The design implementation of the CQ ventilation system and acoustic mitigation are very inter-related and require consideration of crew comfort balanced with use of interior habitable volume, accommodation of fan failures, and possible crew uses that impact ventilation and acoustic performance. This paper illustrates the types of model analysis, assumptions, vehicle interactions, and trade-offs required for CQ ventilation and acoustics. Additionally, on-orbit ventilation system performance and initial crew feedback is presented. This approach is applicable to any private enclosed space that the crew will occupy.

Broyan, James Lee, Jr.↗

Altitude-Wind-Tunnel Investigation of R-4360-18 Power-Plant Installation for XR60 Airplane: Performance of Induction and Exhaust Systems - 3

A study has been made of the performance of the induction and the exhaust systems on the XR60 power-plant installation as part of an investigation conducted in the Cleveland altitude wind tunnel. Altitude flight conditions from 5000 to 30,000 feet were simulated for a range of engine powers from 750 to 3000 brake horsepower. Slipstream rotation prevented normal pressure recoveries in the right side of the main duct in the region of the right intercooler cooling-air duct inlet. Total-pressure losses in the charge-air flow between the turbosupercharger and the intercoolers were as high as 2.1 inches of mercury. The total-pressure distribution of the charge air at the intercooler inlets was irregular and varied as much as 1.0 inch of mercury from the average value at extreme conditions, Total-pressure surveys at the carburetor top deck showed a variation from the average value of 0.3 inch of mercury at take-off power and 0.05 inch of mercury at maximum cruising power, The carburetor preheater system increased the temperature of the engine charge air a maximum of about 82 F at an average cowl-inlet air temperature of 9 F, a pressure altitude of 5000 feet, and a brake horsepower of 1240.

Dupree, David T.↗

Acoustic wave propagation in heterogeneous structures including experimental validation

A finite element model was developed to solve for the acoustic pressure and energy fields in a heterogeneous suppressor. The derivations from the governing equations assumed that the material properties could vary with position resulting in a heterogeneous variable property two-dimensional wave equation. This eliminated the necessity of finding the boundary conditions between different materials. For a two media region consisting of part air and part bulk absorber, a model was used to describe the bulk absorber properties in two directions. Complex metallic structures inside the air duct are simulated by simply changing element properties from air to the structural material in a pattern to describe the desired shapes. To verify the numerical theory, experiments were conducted without flow in a rectangular duct with a single folded cavity mounted above the duct and absorbing material mounted inside a cavity. Changes in a nearly plane wave sound field were measured on the wall opposite the absorbing cavity. Fairly good agreement was found in the standing wave pattern upstream of the absorber and in the decay of pressure level opposite the absorber, as a function of distance along the duct. The finite element model provides a convenient method for evaluating the acoustic properties of bulk absorbers.

Baumeister, Kenneth J.↗

Acoustic wave propagation in heterogeneous structures including experimental validation

A finite element model was developed to solve for the acoustic pressure and energy fields in a heterogeneous suppressor. The derivations from the governing equations assumed that the material properties could vary with position resulting in a heterogeneous variable property two-dimensional wave equation. This eliminated the necessity of finding the boundary conditions between different materials. For a two-media region consisting of part air and part bulk absorber, a model was used to describe the bulk absorber properties in two directions. Complex metallic structures inside the air duct are simulated by simply changing element properties from air to the structural material in a pattern to describe the desired shapes. To verify the numerical theory, experiments were conducted without flow in a rectangular duct with a single folded cavity mounted above the duct and absorbing material mounted inside a cavity. Changes in a nearly plane wave sound field were measured on the wall opposite the absorbing cavity. Fairly good agreement was found in the standing wave pattern upstream of the absorber and in the decay of pressure level opposite the absorber, as a function of distance along the duct. The finite element model provides a convenient method for evaluating the acoustic properties of bulk absorbers.

Baumeister, Kenneth J.↗