Aerosol-Based Sealant for Air Ducts Technology

Aerosol-based sealant can be used to seal air duct leaks. This is done by pressurizing the ducts and injecting the spray sealant. This technology can be used to seal small (up to ½-inch diameter) and inaccessible duct leaks hidden in wall, ceiling, and floor cavities (Ternes and Hwang2001). The aerosol sealant itself is a nontoxic vinyl polymer (Kallett et al. 2000). The technology is a proprietary duct-sealing method developed jointly by the U.S. government and Aeroseal, the company that holds an exclusive license to use the technology (Ternes and Hwang 2001). Specifically, Lawrence Berkeley National Laboratory developed the aerosol-spray technology with funding from the U.S. Department of Energy (DOE), the U.S. Environmental Protection Agency, and others while Aeroseal developed the current version of the equipment and software to apply the technology in practice (Ternes and Hwang 2001).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulation-Based Analysis of Impacts of Reduced Envelope and Duct Air Leakage on Indoor Air Pollutant Concentrations in Occupied Manufactured Homes

This report presents a simulation-based analysis that estimates the magnitude of indoor air pollutant concentration changes that could result from the proposed energy conservation standards. The analysis was conducted for a 1568 ft 2 , double-wide MH with variations in heating and cooling equipment (either furnace + air conditioner or heat pump) and various types of whole-house mechanical ventilation (continuous exhaust fan or central fan integrated supply), in three locations with varying climate conditions: Chicago IL, Fresno, CA; and Houston TX. The simulations tracked four air pollutants that can reach levels exceeding established safe target levels in homes: acrolein, formaldehyde, fine particulate matter (PM 2.5 ), and nitrogen dioxide (NO 2 ). The simulations considered acrolein and formaldehyde emitted from continuous indoor sources; acrolein, NO 2 and PM 2.5 from cooking; PM 2.5 from dispersed occupant activities; and NO 2 and PM 2.5 from outdoors, using historical data to identify typical levels. The impacts in homes operating or not operating whole-house mechanical ventilation equipment, kitchen and bath exhaust fans, and window opening as ventilation approaches were examined.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LBNL Fault Detection and Diagnostics Datasets

These datasets can be used to evaluate and benchmark the performance accuracy of Fault Detection and Diagnostics (FDD) algorithms or tools. It contains operational data from simulation, laboratory experiments, and field measurements from real buildings for seven HVAC systems/equipment (rooftop unit, single-duct air handler unit, dual-duct air handler unit, variable air volume box, fan coil unit, chiller plant, and boiler plant). Each dataset includes a .pdf file to document key information necessary to understand the content and scope, multiple csv files containing all the time-series data for faults at different severity levels and one fault-free case, and a ttl file to visualize the data according to BRICK schema. The dataset was created by LBNL, PNNL, NREL, ORNL and Drexel University.

AC↗

Development of a Annual Air Handling Unit Fault Dataset for FDD Tools: Lessons Learned and Considerations for FDD Developers

As energy management and information systems (e.g., automated fault detection and diagnostics [AFDD] tools) become more prevalent in the commercial building stock, it is important to determine the effectiveness of these technologies by benchmarking their performance. The authors have been working to develop the largest publicly available dataset of HVAC fault data for performance benchmarking applications, covering the most common HVAC systems and designs including chiller plants, rooftop packaged units, dual duct air handling units and single duct air handling units. This study covers the development, modeling, and validation of a synthetic fault dataset for a single duct air handling unit (AHU), one of the most common HVAC configurations found in the commercial building stock. Despite this being a common system, real-world time series data are scarce and usually do not span a wide range of weather conditions. Due to this limitation, a detailed AHU model was employed to carry out annual simulations of numerous common sensor and mechanical faults, which were then validated by comparing their effects on system performance to expected symptoms. We summarize the nature of each fault and their impacts under different weather and operation conditions. Finally, we highlight considerations for FDD developers that may want to use this dataset to assess their algorithms’ performance and their improvement over time.

Casillas, Armando↗

Modeling Air Handling Units to Create a Diverse Fault Dataset for FDD Innovation: Lessons Learned and Recommendations

As energy management and information systems (e.g., automated fault detection and diagnostics [AFDD] tools) become more prevalent in the commercial building stock, it is important to determine the effectiveness of these technologies by benchmarking their performance. The authors have been working to develop the largest publicly available dataset of HVAC fault datasets for performance benchmarking applications, covering the most common HVAC systems and designs including chiller plants, rooftop packaged units, dual duct air handling unit and single duct air handling units. This study covers the development, modeling, and validation of a synthetic fault dataset for the air handling unit (AHU), one of the most common HVAC configurations found in the commercial building stock. Despite this being a common system, real-world time series data are scarce and usually do not span a wide range of weather conditions. Due to this limitation, two detailed AHU models, which included the single duct AHU and dual duct AHU developed in the Modelica language and HVACSIM+ were employed to carry out annual simulations of numerous common sensor faults, mechanical faults, and control sequence faults. The fault inclusive data were then validated by comparing fault effects on system performance to expected symptoms. We summarize the nature of each fault and their impacts under different weather and operation conditions. We report some lessons learnt during the efforts of validating the high volumes of the FDD data sets. Finally, we highlight considerations for FDD developers that may want to use this dataset to assess their algorithms’ performance and their improvement over time.

Casillas, Armando↗

THERMS Technology Commercialization Fund Final Report

The technology commercialization fund assisted with the design and development of an intermediate scale packed be thermal energy storage system. Presented in this final report is the design, testing, and modeling of a 100 kWh th radial packed-bed. Air is used as a heat transfer fluid and 3/8” pea gravel is used as the storage medium. Testing has demonstrated the formation of a thermocline within the packed-bed. An air charging temperature of 450 °C was achieved resulting in a charging power of 26.5 kWh th . The radial packed-bed was charged for 5 hours and discharged for 5 hours. Minimal temperature variation was observed at the bottom, middle, and top axial locations of the radial packed-bed which suggests that buoyancy and hydrodynamics in the injection well had a minimal effect on the uniformity of air flow through the bed during charging and discharging. This indicates that the forced convection in a radial direction is dominating the flow regime compared to the buoyancy. The findings of this study suggest an increased air duct diameter through the air heater will increase the charging temperature and increase air mass flow through the system. Increased mass flow through the packed-bed is hypothesized to shorten the thermocline length. Modeled and measured results are compared, and it is here determined that a more comprehensive CFD model will aid in the understanding of air flow and thermocline evolution within the packed-bed.

25 ENERGY STORAGE↗

Air Return Strategies and Airborne SARS-CoV-2

Dedicated ducted air return per zone for heating, ventilating, and air-conditioning (HVAC) systems is sometimes claimed to be a superior technique over plenum return strategy from the viewpoint of exposure reduction to airborne pathogens. While both the return strategies have advantages, there is limited evidence in the literature as to which strategy is superior merely from a standpoint of building vulnerability to airborne contaminants. We performed multizonal airborne contaminant dispersion modelling using CONTAM to simulate the overall building vulnerability to airborne SARS-CoV-2 aerosols when released in an office building and evaluated the two air return strategies. Results showed that for ducted returns, maintaining negative pressure in the release zone coupled with 100% outdoor air supply can greatly reduce overall building vulnerability. However, for a building maintained under a slight positive pressure and a recirculated air percentage as low as 31%, ducted returns do not necessarily outperform plenum returns in terms of overall building vulnerability to airborne pathogens. Building-specific details and factors that are not easily represented with multizone modelling are important, making general preferential statements for either strategy difficult to make. Insights from this study can guide new construction and retrofits of buildings both during and after the COVID-19 pandemic with the aim of safe re-occupancy of buildings while keeping the buildings resilient against potential future epidemics spread by airborne agents.

Shrestha, Prateek↗

Using non-invasive MEMS pressure sensors for measuring building envelope air leakage

Micro-electromechanical systems (MEMS)-based sensors have seen significant improvements in accuracy and cost over the past several years, and due to the need for altitude sensing in unmanned aerial vehicles and wearable technologies, absolute pressure sensors have shown the most dramatic improvements. This paper investigates applications of MEMS sensors in commercial buildings, including pairing two absolute pressure sensors to determine differential pressures between different locations in and around buildings. Differential pressure measurements are commonly made in commercial buildings for a number of applications, including static pressure measurements for variable-speed supply fan control, air balancing in hospitals, and for envelope and duct air leakage testing. This paper focuses specifically on envelope air-leakage testing applications of these sensors. The use of continuous pressure measurements in addition to one-time non-intrusive outdoor airflow measurements of rooftop packaged units is investigated. A comparison with standardized leakage testing indicated that continuous measurements with MEMS pressure-sensors were able to estimate envelope leakage to within 3–16% of the standardized test result. In addition, the magnitude and stability of differential pressure differences that can be resolved with absolute pressure sensors are also investigated in the laboratory and the field. Results show that the sensors can be effectively used for pressures seen in low rise buildings with rooftop units.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of the indoor near-field aerosol transmission in a model commercial office building

To evaluate the exposure potential of infectious aerosols containing SARS-CoV-2 in an office building setting, synthetic test aerosols were used to experimental study airborne particle transmission in a multizone small office test building at the Oak Ridge National Laboratory. Nine measurement points in a single zone using active aerosol impactors report that the coefficient of variation of the time-averaged concentration is <10% in two campaigns and < 15% in one campaign, so a nearly well-mixed condition was noted. To understand the effect of HVAC system operation on the dynamic concentration of aerosols in office spaces, an aerosol transport model that includes factors such as outside air (OA) ratio, filtration, return air fraction, transport loss in air ducts, and particle deposition has been developed. The results of model fitting demonstrate strong agreement with experimental data. Overall, our investigation finds the return air fraction effects outweigh other mechanisms for the aerosol recirculation in this study, and the impact of air change rate (ACR) is more important than the small particle deposition for aerosol removal. Because ACR dominates the aerosol transport, the full model can be simplified to just one factor, the ACR, while maintaining an acceptable representation of the experimental data.

60 APPLIED LIFE SCIENCES↗

Evaluation of nonlinear control performance of air handling units under variable operation conditions using root distribution approach

The control systems at Air handling units (AHUs) have nonlinear nature, resulting potentially in sluggish, aggressive, or oscillatory responses under variable operation conditions. This paper is to develop an approach for evaluating the nonlinear control performance of AHUs under variable operation conditions and for identifying the impact of varying multiple operation parameters which guides controller design. To do so, an operation parameter-based root distribution technique, intended to sketch the paths traced by closed-loop poles as multiple operation parameters are varied, is first introduced. The technique—which may be viewed as an extension of conventional, single-variable root locus—is then applied to a fan speed control system that includes a motor with a variable frequency drive and a supply fan with an air duct under variable fan speed and duct static pressure. Using the technique, the system’s stability region is graphically identified. The system is also found to be aggressive and gradually lose its stability as the fan speed decreases and the duct static pressure increases, which is validated by the field tests. Here, the root distribution approach is an effective tool to evaluate the performance of any nonlinear control systems at AHUs with multiple variable operation parameters without requiring time-domain simulations.

42 ENGINEERING↗

ResStock Measure Documentation: Advanced Air Sealing, Attic Floor Insulation, Duct Sealing and Insulation, and Drill-and-Fill Wall Insulation

This report is part of a series describing different ResStock measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Advanced Air Sealing, Attic Floor Insulation, Duct Sealing and Insulation, and Drill-and-Fill Wall Insulation" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Validation of a Co-Optimized, Smart Hybrid Heat Pump Control

This study examines a residential dual fuel (DF) heating system that integrates heat pump and gas furnace technology with a home’s forced-air distribution ducts. Specifically, it explores a retrofit where an “add-on” heat pump replaces the air conditioning (A/C) system and is combined with the home’s existing furnace and air handler. The research team developed and validated an innovative control scheme for this integrated DF system that selected the more economical heating source (furnace or heat pump) while maintaining comfort in the home. The project’s field study and subsequent modeling analysis show that this control scheme can decrease energy use, cost, and emissions compared to a furnace-only system. As homes in mixed and cold climates transition to more electric space heating, furnace-to-dual fuel system retrofits offer a solution that can alleviate the retrofit costs, energy cost concerns, and peak load impacts of full electrification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reference document for LANL stack sampling and ANSI N13.1 (Article) Gielow RL and McNamee MR 1993. Numerical Flue Gas Flow Modeling for Continuous Emissions Monitoring Applications. EPRI CEM Users Group Meeting. Baltimore. RP1961-13

American National Standard N13.1 “sets forth guidelines and performance criteria for sampling the emissions of airborne radioactive substances in the air discharge ducts and stacks of nuclear facilities. Emphasis is on extractive sampling from a location in a stack or duct where the contaminant is well mixed. At such a location, sampling may be conducted at a single point. This standard provides performance-based criteria for the use of air sampling probes, transport lines, sample collectors, sample monitoring instruments, and gas flow measuring methods. This standard also covers sampling program objectives, quality assurance issues, developing air sampling action levels, system optimization, and system performance verification. Workplace, containment, and environmental air monitoring are not addressed. Specific sample analysis methods and the reporting or interpreting of results are also not addressed.” (HPS 2011).

61 RADIATION PROTECTION AND DOSIMETRY↗

ResStock Measure Documentation: Advanced Air Sealing, Attic Floor Insulation, and Duct Sealing and Insulation

This report is part of a series describing different ResStock measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Advanced Air Sealing, Attic Floor Insulation, and Duct Sealing" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Indoor air quality in California homes with code-required mechanical ventilation

Data were collected in 70 detached houses built in 2011-2017 in compliance with the mechanical ventilation requirements of California's building energy efficiency standards. Each home was monitored for a 1-week period with windows closed and the central mechanical ventilation system operating. Pollutant measurements included time-resolved fine particulate matter (PM 2.5 ) indoors and outdoors and formaldehyde and carbon dioxide (CO 2 ) indoors. Time-integrated measurements were made for formaldehyde, NO 2 , and nitrogen oxides (NO X ) indoors and outdoors. Operation of the cooktop, range hood, and other exhaust fans was continuously recorded during the monitoring period. Onetime diagnostic measurements included mechanical airflows and envelope and duct system air leakage. All homes met or were very close to meeting the ventilation requirements. On average, the dwelling unit ventilation fan moved 50% more airflow than the minimum requirement. Pollutant concentrations were similar to or lower than those reported in a 2006-2007 study of California new homes built in 2002-2005. Mean and median indoor concentrations were lower by 44% and 38% for formaldehyde and 44% and 54% for PM 2.5 . Ventilation fans were operating in only 26% of homes when first visited, and the control switches in many homes did not have informative labels as required by building standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Energy Codes Gap Analysis Field Study in the Southwest (Final Technical Report)

The primary goal of the “An Energy Codes Gap Analysis Field Study in the Southwest” project was to improve housing through strengthened building energy code implementation in two states, Colorado and Nevada, leading to greater energy and utility bill savings for households. Colorado is a home rule state. Nevada adopts a statewide code, but cities and counties must also adopt the code, making the state function like a home rule state. To broaden the impact of the project, an additional goal was to share and amplify project experiences, findings, and lessons that can be applied in other states. To achieve these goals, the project’s key objectives were to examine how residential energy codes are implemented in partner states; to use these findings to strengthen codes implementation through enhanced education, training, and outreach; and to enhance energy code technical assistance capabilities in the two partner states. In both partner states, the project led to the creation of a quantitative baseline understanding of compliance with high-impact energy code requirements, such as foundation, wall, and ceiling R-value; window U-factor and SHGC; envelope air tightness; duct tightness; and high-efficiency lighting. It then applied this baseline information to directly inform training in geographic areas with high levels of building and construction activity. The project has placed Colorado and Nevada among 23 states across the country that have conducted a single-family residential field study based on the established U.S. Department of Energy (DOE) methodology since 2014. It has also helped each State Energy Office test models for partnership- and relationship-building among government agencies and key stakeholder groups, including the State Energy Office and relevant code administration and professional licensing agencies, building officials, designers, builders, trades and utilities. At the national level, the project helped educate and inform State and Territory Energy Offices on a replicable methodology to assess energy code construction practices, effective stakeholder engagement strategies, and tailored energy code education and training. These findings are particularly pertinent for home-rule states, such as Colorado and Nevada, which rely on local government awareness and action to advance and implement building energy codes. By raising awareness of code adoption and compliance, this project has helped to equip each partner state with data on code compliance, strategies, education, and partnership models to advance building energy codes. This in turn will have an important impact on new construction practices in Colorado and Nevada, leading to more energy efficient and affordable housing. Currently, more than 62 percent of Colorado’s population lives in one of the 55 jurisdictions that have adopted the 2021 IECC to date, while nearly 95 percent of the state's population lives in one of the 208 jurisdictions that have adopted a code at 2015 IECC levels or higher. In Nevada, the 2018 IECC was adopted by the Governor’s Office of Energy in July 2018. By July 2020, 47 percent of the adopted energy code in the state was 2018 IECC which covers 96.5 percent of Nevada’s population. The training materials funded by this project focus on the 2021 IECC and will continue to be relevant in the two states as additional jurisdictions update their building energy codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pennsylvania and Delaware Energy Code Field Studies (Final Technical Report (FTR)

Led by Northeast Energy Efficiency Partnerships (NEEP) in partnership with Performance Systems Development (PSD), the project aimed to conduct energy code compliance field studies for single-family residential buildings in Pennsylvania and Delaware, as well as multifamily and commercial buildings in Pennsylvania. Using U.S. Department of Energy (DOE) approved methodologies, trained field teams conducted on-site observations and testing to document compliance with key energy efficiency measures, including building envelope insulation, air sealing, duct leakage, windows, and mechanical systems. Data from these studies would then be analyzed to identify construction trends and compliance gaps. The goals included published baseline data for each study, and a training roadmap tailored to each state’s needs. This roadmap would have guided outreach and training for builders, code officials, and other stakeholders on the specific code requirements that offered the greatest opportunity for improvement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗