Search NASA⌕ Search

SEARCH · Search NASA

Results for “air handling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Machine learning based simultaneous control of air handling unit discharge air and condenser water temperatures set-point for minimized cooling energy in an office building

In this study, an artificial intelligence based real-time prediction and control model to optimize condenser water temperature and discharge air temperature (DAT) set-points in water-cooled air handling unit (AHU) system has been developed. EnergyPlus-MATLAB co-simulation has been conducted to analyze the developed model's effectiveness. Here, to develop artificial neural networks (ANN) model, embedded neural network objects in MATLAB was utilized. The developed model could decide an optimal temperature set-points based on outdoor air wet-bulb temperature to reflect the Korean climate context. As a result, the developed ANN prediction model showed the predictive performance of Cv(RMSE) of approximately 21%. Compared to the conventional fixed temperature algorithm, which fixes AHU DAT at 14°C and condenser water temperature at 32°C, the ANN based optimized control showed a 22% total cooling energy reduction. These results show that significant energy savings can be achieved by simultaneously controlling condenser water temperature and AHU DAT set-points considering Korean climatic characteristics using AI technologies such as ANN models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Potential Cooling Energy Savings of Economizer Control and Artificial-Neural-Network-Based Air-Handling Unit Discharge Air Temperature Control for Commercial Building

Heating, ventilation, and air-conditioning (HVAC) systems play a significant role in building energy consumption, accounting for around 50% of total energy usage. As a result, it is essential to explore ways to conserve energy and improve HVAC system efficiency. One such solution is the use of economizer controls, which can reduce cooling energy consumption by using the free-cooling effect. However, there are various types of economizer controls available, and their effectiveness may vary depending on the specific climate conditions. To investigate the cooling energy-saving potential of economizer controls, this study employs a dry-bulb temperature-based economizer control approach. The dry-bulb temperature-based control strategy uses the outdoor air temperature as an indicator of whether free cooling can be used instead of mechanical cooling. This study also introduces an artificial neural network (ANN) prediction model to optimize the control of the HVAC system, which can lead to additional cooling energy savings. To develop the ANN prediction model, the EnergyPlus program is used for simulation modeling, and the Python programming language is employed for model development. The results show that implementing a temperature-based economizer control strategy can lead to a reduction of 7.6% in annual cooling energy consumption. Moreover, by employing an ANN-based optimal control of discharge air temperature in air-handling units, an additional 22.1% of cooling energy savings can be achieved. In conclusion, the findings of this study demonstrate that the implementation of economizer controls, especially the dry-bulb temperature-based approach, can be an effective strategy for reducing cooling energy consumption in HVAC systems. Additionally, using ANN prediction models to optimize HVAC system controls can further increase energy savings, resulting in improved energy efficiency and reduced operating costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cooling performance of direct expansion system using multiple stages and adjustable heat exchange areas for fresh air handling

Providing fresh air to rooms can ensure indoor air quality. The direct expansion fresh air handling units are widely used, and most of them are single-stage treatment units, which are less energy-efficient under variable operating conditions. To overcome the shortcomings of existing systems, a direct expansion system using multiple stages and adjustable heat exchange areas for fresh air handling is proposed in this study. The fresh air is handled by coils stage by stage to achieve high efficiency, and the dampers of the idle coils are opened when some of the coils are working, which results in the performance improvement under partial load conditions. The simulation model is established, and operating conditions at load ratio of 95.70%, 45.38%, 31.76% and 0 are selected as typical operating conditions. The proposed system performances under different conditions are compared with traditional system. The results show that: (1) For four conditions, as the load rate decreases, the proposed system can save energy by 6.2%, 26.1%, 46.5%, and 25.0% compared to the traditional system respectively; (2) The proposed system can bypass the filter when the outdoor air is good, which can further save energy by 1.3%, 1.8%, 3.4%, and 25.9% under four conditions, respectively.

Zha, Fuhai↗

Modeling Air Handling Units to Create a Diverse Fault Dataset for FDD Innovation: Lessons Learned and Recommendations

As energy management and information systems (e.g., automated fault detection and diagnostics [AFDD] tools) become more prevalent in the commercial building stock, it is important to determine the effectiveness of these technologies by benchmarking their performance. The authors have been working to develop the largest publicly available dataset of HVAC fault datasets for performance benchmarking applications, covering the most common HVAC systems and designs including chiller plants, rooftop packaged units, dual duct air handling unit and single duct air handling units. This study covers the development, modeling, and validation of a synthetic fault dataset for the air handling unit (AHU), one of the most common HVAC configurations found in the commercial building stock. Despite this being a common system, real-world time series data are scarce and usually do not span a wide range of weather conditions. Due to this limitation, two detailed AHU models, which included the single duct AHU and dual duct AHU developed in the Modelica language and HVACSIM+ were employed to carry out annual simulations of numerous common sensor faults, mechanical faults, and control sequence faults. The fault inclusive data were then validated by comparing fault effects on system performance to expected symptoms. We summarize the nature of each fault and their impacts under different weather and operation conditions. We report some lessons learnt during the efforts of validating the high volumes of the FDD data sets. Finally, we highlight considerations for FDD developers that may want to use this dataset to assess their algorithms’ performance and their improvement over time.

Casillas, Armando↗

Development of a Annual Air Handling Unit Fault Dataset for FDD Tools: Lessons Learned and Considerations for FDD Developers

As energy management and information systems (e.g., automated fault detection and diagnostics [AFDD] tools) become more prevalent in the commercial building stock, it is important to determine the effectiveness of these technologies by benchmarking their performance. The authors have been working to develop the largest publicly available dataset of HVAC fault data for performance benchmarking applications, covering the most common HVAC systems and designs including chiller plants, rooftop packaged units, dual duct air handling units and single duct air handling units. This study covers the development, modeling, and validation of a synthetic fault dataset for a single duct air handling unit (AHU), one of the most common HVAC configurations found in the commercial building stock. Despite this being a common system, real-world time series data are scarce and usually do not span a wide range of weather conditions. Due to this limitation, a detailed AHU model was employed to carry out annual simulations of numerous common sensor and mechanical faults, which were then validated by comparing their effects on system performance to expected symptoms. We summarize the nature of each fault and their impacts under different weather and operation conditions. Finally, we highlight considerations for FDD developers that may want to use this dataset to assess their algorithms’ performance and their improvement over time.

Casillas, Armando↗

A Year-Round Energy-Efficient Fresh Air Handling System with Two-Stage Heat Pumps and Lake Water Pre-Treatment

Supplying fresh air is important for indoor air quality, but the energy consumption to treat fresh air is significant. The main problems in existing fresh air system include: supplying single-temperature water to treat fresh air and not applying natural energy sufficiently restrict the efficiency improvement of cooling and heat sources; unused air handling devices under most operating conditions throughout the year increase the fan energy consumption. Thus, this study proposes an efficient fresh air system that uses lake water to pre-treat fresh air and two-stage heat pumps for further treatment, and the unused air handling devices in the system are bypassed. A fresh air system in northern China is selected as a case to show the annual energy performance of the proposed system, and a comparative analysis is conducted between the proposed system and a traditional system. The results show that the annual energy-savings of the proposed system compared to the traditional system come from fans, and compressors, which are 56.5%, and 31.1%, respectively, with an entire system energy saving of 32.2%. The proposed system can achieve an annual system coefficient of performance (COP) of 5.5. This study provides potential for further improving the energy efficiency in fresh air treatment.

Liang, Chenjiyu↗

Evaluation of supply air temperature control performance with different control strategies at air handling units

Due to its nonlinear feature, supply air temperature control systems at air handling units using single-loop fixed gain control frequently suffer unstable response under dynamic conditions. This paper is aimed at identifying a more effective control strategy to stabilize the valve control and achieve desirable supply air temperature response under various operation conditions by evaluating three control strategies, cascade, gain scheduling and cascade plus gain scheduling controls. Firstly, a control-oriented model is developed and calibrated through open-loop tests. Then, the control issues with single-loop fixed gain control are evaluated through simulations and field tests, which indicates that the system has more aggressive response or becomes unstable under lower load conditions when the chilled-water flow rate is less than 0.1 L/s. Finally, three control strategies are proposed and evaluated. Further, the results reveal that all three proposed controls can achieve better robustness with the integral square error of supply air temperature decreased to 16%, 47% and 5%, respectively, under lower load condition. However, since high-frequency oscillation of the control valve occurs with cascade and cascade plus gain scheduling control, the gain scheduling control is recommended considering a trade-off among the supply air temperature response, valve lifetime and implementation complexity.

42 ENGINEERING↗

Modelling of air handling unit subsystem in a commercial building

To improve energy efficiency of the Air Handling Unit (AHU), there is a need for a system to monitor energy performance of the AHU in real time, to optimize operation for minimum energy consumption and to calculate energy saving. A mechanical model was created to analyze the performance of subsystems in an AHU and was validated using actual data collected from AHU operation via a wireless monitoring system. Algorithms have been developed to identify malfunctions and estimate the savings if malfunctions are corrected. Here, the model detects control related malfunctions, such as simultaneously turning on the cooling coil and the pre-heating coil. According to the mechanical model of the case study system, a total of 63,455 kWh are wasted within the cooling coil and the pre-heating coil due to this type of control malfunction. Furthermore, the mechanical model can identify other energy savings opportunities due to set point changes; in the case study system, this feature revealed a total of 77,141 kWh energy saving during the same study period. The design, integration, and validation of the mechanical model are described, analyzed, and justified in this paper.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic Simulation Modeling and Control of a Desiccant Assisted Direct-expansion Air Handling Unit

Desirable built environments demand simultaneous regulation of thermal comfort and indoor air quality (IAQ) with energy-efficient operation of heating, ventilation and air conditioning (HV AC) systems, which involves controls of temperature, humidity and airborne contaminants simultaneously. This paper presents the efforts of dynamic modeling and initial development control strategy for a desiccant-assisted multi-functional air handling unit (AHU) coupled with a direct-expansion rooftop unit (RTU) system, which aims to achieve multiple functions for indoor environment conditioning with energy efficient control. The RTU-AHU system includes a desiccant wheel for dehumidification and a conceptual direct air capture (DAC) filtering device for CO2 regulation. A Modelica-based dynamic model is developed for this conceptual system, and a simple decentralized control strategy is designed, which combines a differential-enthalpy based AHU return-air ratio control, a demand-controlled ventilation, and supply-air temperature humidity control via the RTU and DW controls. The proposed control method is evaluated with the Modelica simulation model for a selected set of scenarios

Pan, Chao↗

Evaluation of nonlinear control performance of air handling units under variable operation conditions using root distribution approach

The control systems at Air handling units (AHUs) have nonlinear nature, resulting potentially in sluggish, aggressive, or oscillatory responses under variable operation conditions. This paper is to develop an approach for evaluating the nonlinear control performance of AHUs under variable operation conditions and for identifying the impact of varying multiple operation parameters which guides controller design. To do so, an operation parameter-based root distribution technique, intended to sketch the paths traced by closed-loop poles as multiple operation parameters are varied, is first introduced. The technique—which may be viewed as an extension of conventional, single-variable root locus—is then applied to a fan speed control system that includes a motor with a variable frequency drive and a supply fan with an air duct under variable fan speed and duct static pressure. Using the technique, the system’s stability region is graphically identified. The system is also found to be aggressive and gradually lose its stability as the fan speed decreases and the duct static pressure increases, which is validated by the field tests. Here, the root distribution approach is an effective tool to evaluate the performance of any nonlinear control systems at AHUs with multiple variable operation parameters without requiring time-domain simulations.

42 ENGINEERING↗

Improving the nonlinear control performance of the supply fan at air handling units using a gain scheduling control strategy

Due to its nonlinear nature, the supply fan at air handling units with the controller tuned at the design condition tends to be aggressive and oscillate under partial load conditions. Here, the objective of this paper is to develop and validate a gain scheduling control strategy to improve its nonlinear control performance. First, a control-oriented model, which does not require numerous physical parameters and extensive test data, is developed to study the nonlinearity of the fan system. Based on the theoretical model and experimental verifications, the issue of an aggressive response with a conventional fixed-gain controller is caused by the fact that the system gain is proportional to the ratio of the duct static pressure to the fan speed. To address the issue, a scheduling function of the measurable duct static pressure and fan speed is proposed to be included in the conventional fixed-gain controller to compensate for the fan system gain variation. The gain scheduling control strategy is found to approximately maintain the identical control performance under all operation conditions. Most importantly, the gain scheduling control strategy can be readily implemented without intensive computation and additional measurements, showing a promising potential in industrial applications.

42 ENGINEERING↗

Experimental Investigation of the Effect of Air-Handling and DME-Propane Blends on the Performance and Emissions of a 4-Cylinder CI Engine

Dimethyl ether (DME) is considered an excellent alternative to diesel because of its higher cetane number and lower carbon content. Additionally, DME can be blended with abundantly available propane with minimal modifications to the propane infrastructure. This paper focuses on an experimental investigation of the effect of air-handling i.e., boost pressure and exhaust gas recirculation (EGR), and DME-propane blends on the combustion and emissions performance of a light-duty, four-cylinder, compression ignition (CI) engine. Here, the boost pressure and EGR sweeps were carried out and showed that higher boost pressures resulted in increased brake thermal efficiencies (BTE) at the expense of higher NOx emissions which could be reduced by an increase in EGR. The fuel sweeps were carried out at 0, 15 and 25% propane (neat, 85% and 75% DME) with 0% and 25% EGR. The fuel sweeps indicated that the ignition delay (ID) increased and burn duration (BD) decreased monotonically when the blend increased to 25% propane/75% DME. The results suggest optimum engine performance with neat DME at 105 kPa boost pressure and 25% EGR with propane addition improving the BTE with negligible increase in emissions. Higher contents of Propane, up to 25%, did not affect the variability of combustion, with standard deviations of burn duration and peak cylinder pressures below 1% for all test cases.

air-handling↗

Self-Correcting HVAC Controls: Algorithms for Sensors and Dampers in Air-Handling Units

This report documents the self-correction algorithms developed in the Self-Correcting Heating, Ventilating and Air-Conditioning (HVAC) Controls project funded jointly by the Bonneville Power Administration and the Building Technologies Program of the U.S. Department of Energy. The algorithms address faults for temperature sensors, humidity sensors, and dampers in air-handling units and correction of persistent manual overrides of automated control systems. All faults considered create energy waste when left uncorrected as is frequently the case in actual systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Uncertainty Analysis for a Virtual Flow Meter Using an Air-Handling Unit Chilled Water Valve

A virtual water flow meter is developed that uses the chilled water control valve on an air-handling unit as a measurement device. The flow rate of water through the valve is calculated using the differential pressure across the valve and its associated coil, the valve command, and an empirically determined valve characteristic curve. Thus, the probability of error in the measurements is significantly greater than for conventionally manufactured flow meters. In this paper, mathematical models are developed and used to conduct uncertainty analysis for the virtual flow meter, and the results from the virtual meter are compared to measurements made with an ultrasonic flow meter. Theoretical uncertainty analysis shows that the total uncertainty in flow rates from the virtual flow meter is 1.46% with 95% confidence; comparison of virtual flow meter results with measurements from an ultrasonic flow meter yielded anuncertainty of 1.46% with 99% confidence. The comparable results from the theoretical uncertainty analysis and empirical comparison with the ultrasonic flow meter corroborate each other, and tend to validate the approach to computationally estimating uncertainty for virtual sensors introduced in this study.

Song, Li↗

Air Handling Unit Shutdowns During Scheduled Unoccupied Hours: US Commercial Building Stock Prevalence and Energy Impact

Commercial buildings account for 18% of U.S. energy consumption, with 44% used for heating, ventilation, and air conditioning (HVAC). American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) 90.1 requires HVAC systems to shutdown fans and outdoor air ventilation during unoccupied times, only allowing fans to cycle on, without outdoor air, to maintain thermostat setpoints. However, it is minimally understood how often existing building operations align with energy code requirements and the energy implications of not doing so. This study used building automation system data from 843 buildings containing 5706 air handling units (AHUs) to determine three unoccupied AHU shutdown control schemes ranging in efficiency and then estimated their prevalence in the U.S. commercial building stock, segmented by building type. ComStock was then used to analyze the energy savings potential of implementing the most energy efficient unoccupied shutdown control scheme in non-participating buildings across the U.S commercial building stock. Results show that only 23% of AHUs align completely with the ASHRAE 90.1 requirement. ComStock modeling results show 4% annual stock energy savings by switching all non-participating buildings to the most efficient scheme, with 19% annual energy savings demonstrated for the median building switching from the least efficient scheme to the most efficient. Findings also show 114.5 TBtu electricity and 75.8 TBtu natural gas fuel savings when converting to the most efficient scheme. Furthermore, these findings help stakeholders understand the high prevalence of buildings not aligning with the ASHRAE-90.1 requirements for unoccupied AHU shutdowns and the energy savings potential of utilizing the most efficient unoccupied AHU shutdown scheme.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A large-scale evaluation of automated metadata inference approaches on sensors from air handling units

Building automation systems provide abundant sensor data to enable the potential of using data analytics to, among other things, improve the energy efficiency of the building. However, deployment of these applications for buildings, such as, fault detection and diagnosis (FDD) on multiple buildings remains a challenge due to the non-trivial efforts of organizing, managing and extracting metadata associated with sensors (e.g., information about their location, function, etc.), which is required by applications. One of the reasons leading to the problem is that varying conventions, acronyms, and standards are used to define this metadata. To better understand the nature of the problem, as well as the performance and scalability of existing solutions, in this report we implement and test 6 different time-series based metadata inference approaches on sensors from 614 air handling units (AHU) instrumented in 35 building sites accounting for more than 400 buildings distributed across United States of America. We infer 12 types of sensors and actuators in AHUs required by a rule-based FDD application: AHU performance and assessment rules (APAR). Our results show that: (1) the average performance of these approaches in terms of accuracy is similar across building sites, though there is significant variance; (2) the expected accuracy of classifying the type of points required by APAR for a new unseen building is, on average, 75%; (3) the performance of the model does not decrease as long as training data and testing data are extracted from adjacent months.

42 ENGINEERING↗