Minimizing Auxiliary Heat Use for Cold Climate Operation of Air-Source Heat Pumps

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climate conditions. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in northwest United States and one in Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five-seconds, to calculate heat pump's capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides valuable insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving the overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Evaluating Air-Source Heat Pumps with Distributed Energy Resources in REopt

This training introduces attendees to NREL's REopt(R) web tool and its capabilities in evaluating air-source heat pumps (ASHP) alongside distributed energy resources (DERs). Designed for energy managers, facility operators, and sustainability managers, this session will explore how REopt provides techno-economic analysis to assess the financial viability of ASHP while identifying synergies with solar PV and battery storage. Participants will gain practical insights into using REopt to optimize energy strategies, reduce costs, and improve site resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Cold Climate Field Study of the Effect of Defrost Controls on the Integrated Performance of a Ductless Air-Source Heat Pump

Residential heat pumps have advanced over the past decade to allow for operation at colder temperatures. However, the challenges of frost accumulation and defrosting the outdoor coil remain. The goal of this study was to evaluate the impact of the control algorithms that determine when a heat pump needs to defrost and when the base pan heater runs on the overall heating efficiency of the heat pump. In this study, which occurred during the 2023–2024 heating season, we measured the performance of a ductless air-source heat pump installed in Fairbanks, Alaska, USA. The heat pump was instrumented to measure the electrical input and the thermal output, as well as selected internal variables and indoor and outdoor environmental conditions. The heat pump was first operated with factory default control algorithms associated with the initiation of defrost and control of the base pan heater. These factory default algorithms focused on aggressively defrosting the outdoor coil and keeping the base pan ice-free. In the middle of the winter, these algorithms were changed to focus on reducing defrost cycles and increasing efficiency, while the heat pump continued to be operated and monitored. The results showed that significant increases in efficiency are possible by improving the defrost and base pan heater control algorithms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

ResStock Measure Documentation: Cold Climate Air-Source Heat Pump

This report is part of series describing a variety of different ResStock™ measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Cold Climate Air-Source Heat Pump" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

An economic and technical feasibility analysis of a dual-source heat pump using both the air and the ground

The study investigates the economic and technical performance of a novel dual-source heat pump (DSHP) compared with that of air-source heat pumps (ASHPs) and ground-source heat pumps (GSHPs). The DSHP can use both ambient air and the ground as a heat source or heat sink. It uses ambient air when its temperature is favorable for efficient heat pump operation. When the ambient temperature is too hot or cold, the ground source is used to retain high-efficiency heat pump operation. Since the DSHP can alternately use either the ground heat exchanger (GHE) or ambient air to meet the thermal load, the required size of GHE can be smaller than those of GSHPs. This study models the DSHP using a whole building energy simulation tool (EnergyPlus) coupled with a Python plug-in and Heat Pump Design Model (HPDM) to simulate its heating and cooling performance for a typical single-family home in 15 US climate zones. The required GHE size of the DSHP system is determined through simulations and compared with that of GSHPs. DSHP deployment can reduce electricity use compared to ASHPs, especially in cold climates where it shows a reduction of around 50%. When compared to GSHPs, DSHPs use 20%–40% more electricity in warm climates but consume around the same amount in moderate and colder climates. Since the DSHP can use air source when the ambient temperature is mild, the GHE size needed for the DSHP is about 40% less than that needed for GSHPs in hot climates and about 25% less in cold climates. In conclusion, the life cycle cost analysis shows that the DSHP is economically more feasible than ASHPs in colder regions and economically more feasible than GSHPs in hot and cold regions.

Dual-source heat pumps

Minimizing Auxiliary Heat Use for Cold Climate Operation of Air Source Heat Pumps: Preprint

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climates. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in the northwest United States and one in a Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five seconds, to calculate the heat pump’s capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Scoping Study of Integrated Geothermal CO 2 Heat Pump and Water Well System in Cold Climate Region

This study evaluates the feasibility of using ground-source heat pumps (GSHPs) integrated with water wells for residential heating demands in cold regions of the United States. Four different heat pump systems were evaluated and compared: a CO 2 air-source heat pump (ASHP), a R-410A ASHP, a CO 2 GSHP integrated with well water, and a R-410A GSHP integrated with well water. Simulations were conducted at both equipment and building integration levels, followed by a nationwide analysis across 10 selected cities. Results indicate that integrating GSHP technology with existing water wells (e.g., artesian, bedrock, drilled, and collector wells) is a feasible heating solution because of their high flow rates, good water quality, stable temperatures, and low environmental impact. Although R-410A systems demonstrate higher efficiency, CO 2 systems are more suitable for heating from contamination-free and energy security perspective. The CO 2 GSHPs maintain better performance in colder climates compared with that of ASHPs, providing higher coefficient of performance and environmental benefits because CO 2 refrigerant leakage would not contaminate well water. A national analysis confirms that CO 2 GSHPs outperform furnaces, especially in cold climates, making them a promising solution for residential heating.

99 GENERAL AND MISCELLANEOUS

Comparative performance assessment of air-source and ground-source heat pumps using CO₂ and R-410A with water well integration: A simulation study

This study investigates the performance and feasibility of heat pump systems for residential space heating in cold climates, with a particular focus on ground source heat pumps (GSHPs) with water wells. Four configurations are modeled and compared, a CO 2 air-source heat pump (ASHP), an R-410A ASHP, a CO 2 GSHP with water well integration, and an R-410A ground-source heat pump with water well integration. System simulations are conducted at both equipment and whole-building levels, followed by a nationwide analysis across ten representative cities using EnergyPlus. Results show that water-well-coupled GSHPs maintain approximately 87 % of their efficiency and 85.5 % of heating capacity as ambient temperature drops from 47 °F/8.3 °C to −15 °F/-26.1 °C, whereas ASHPs retain only 55 % efficiency and 44.5 % capacity. R-410A systems achieve higher efficiency, while CO 2 systems provide significant environmental advantages, including reduced risks of groundwater contamination from refrigerant leakage. On average, the CO 2 GSHPs deliver 35–45 % heating energy savings relative to ASHPs and demonstrate strong potential as a replacement for gas furnaces in cold climates. This work represents a systematic comparative assessment of CO 2 and R-410A air-source and ground-source heat pumps with water well integration. In conclusion, the findings highlight the technical viability, environmental benefits and deployment potential of CO 2 GSHPs, offering a pathway toward efficient and sustainable residential heating solutions in diverse U.S. climates.

CO 2 GSHP

Preliminary Assessment for the Electric Load Shifting Potential of Integrating Thermal Energy Storage with Heat Pumps in Residential Buildings in Texas of United States

The widespread adoption of electric-driven heat pumps for heating and cooling is expected to significantly increase electric demand. Cooling electric demand will result in an increase in peak hours electric loads, placing additional strain on the grid during peak hours. This challenge, combined with the current rapidly increasing demand from data centers, exacerbates the electric demand duck curve problem. Integrating thermal energy storage (TES) with heat pump can shift electric use for heating and cooling from peak to off-peak hours of the electric grid, which can help flatten the daily electric demand profile of a building. This paper presents a novel design that integrates heat pump with TES (HP-TES), which uses phase change materials (PCM). Heat pump charges TES by melting or freezing PCM during off-peak hours when there is no thermal demand from the building. TES is then discharged (i.e., by freezing or melting PCM) during peak hours to provide a more favorable heat source or heat sink for the heat pump to meet the thermal demand of the building with lower electricity use than conventional air-source heat pumps. Computer simulations were developed to predict the performance of HP-TES applied to a typical single-family house in the US. The building-level simulation results were scaled up to preliminarily assess the aggregated impacts of deploying HP-TES across all single-family houses in Texas of the United States, including reduction of peak demand of the electric grid.

Anees, Fady [ORNL]

Field Demonstration and Adoption Impacts of an Affordable Thermoelectric Heat Pump

This study presents the design, field validation, and utility impacts of an air source heat pump that uses thermoelectric (TE) technology to provide supplemental heating at outside air temperatures below 17°F. Conventional heat pumps experience reduced heating capacity and COP at low outdoor temperatures due to the temperature difference between the source and demand sides of the vapor compression cycle. Consequently, during colder months, supplemental heating such as electric resistance or natural gas furnace is often needed to provide additional warmth, which increases the overall equipment and energy costs. To address this challenge, a TE subcooler (an array of solid-state, thermoelectric modules that provides heat pumping using non-vapor compression technique) is fabricated and integrated with the vapor compression cycle of a conventional air-source heat pump. In colder ambient conditions, TE subcooler exchanges heat with the refrigerant to provide additional subcooling, thereby enhancing the capacity of the heat pump. The operation of thermoelectric-integrated heat pump was demonstrated in an occupied single-family home in Nashville, TN. The TE subcooler increased the system’s heating capacity at 15°F outdoor temperature by 25–30% and reduced electricity demand by 10%. It also met the heating load in the house without supplemental electric resistance down to 5°F outdoors, delivering the additional heat at nearly 80% greater efficiency compared to electric resistance heating. With a modest first cost increment of 10–15% over conventional single-speed heat pumps, this approach offers a promising, energy-efficient solution to accelerate residential heat pump adoption in the U.S.

KRISHNAMOORTHY, Sreenidhi [Electric Power Research

Integration of a thermoelectric subcooler with an air‑source heat pump to enhance heating capacity and dehumidification

This study presents an innovative configuration of a thermoelectric subcooler (TES) integrated with an air-source heat pump (ASHP). The TES is installed in the liquid line, where it absorbs heat from the refrigerant. On its hot side, it discharges heat to the return air in heating mode or to the supply air in cooling mode, enabling year-round operation. The ASHP–TES system was evaluated under various conditions to reduce supplemental heating needs and improve dehumidification. Experimental heating tests revealed that activating the TES increased the heating capacity by 12%–20%. However, this occurred with a 7.6%–10% reduction in heating coefficient of performance (COP). In cooling mode, TES operation significantly improved moisture removal. The TES reduced the sensible heat ratio (SHR) and enhanced dehumidification, removing 20%–50% more moisture than a conventional system when meeting the same sensible load. The TES can be turned off to use the refrigerant subcooler for reheat supply air or turned on to substantially boost dehumidification. When meeting the same latent load, the ASHP–TES system achieved up to 33% energy savings compared with a conventional ASHP using resistance heating. Relative to a conventional ASHP paired with a whole-house dehumidifier, the ASHP–TES system provided up to 20% energy savings. These findings underscore the potential of TES integration to improve latent load control and enhance overall energy efficiency in hybrid ASHP systems, especially in cold and humid climates.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING

Comparative Analysis of Model Predictive Control and MPC-Informed Rule-Based Control for Thermal Storage Operation in Ultra-Low Temperature 4th Generation District Heating Networks

The integration of thermal storage and heat pumps in district heating networks (DHNs) can significantly enhance operational flexibility and energy efficiency; however, the practical deployment of advanced control strategies is often hindered by forecasting requirements and computational complexity. This study presents a comparative analysis of thermal storage control strategies in an ultra-low-temperature fourth-generation DHN, focusing on the development of a simplified rule-based control (RBC) explicitly informed by Model Predictive Control (MPC) behavior. The proposed methodology systematically analyzes the charging and discharging decisions of an MPC-controlled system under ideal forecasting conditions and extracts recurrent control patterns as a function of key system variables, including outdoor temperature, thermal demand, and electricity price. These patterns are translated into a set of structured time- and condition-based rules, resulting in an MPC-informed RBC that embeds predictive insights while preserving implementation simplicity and operational transparency. The approach is validated on a realistic mixed-use urban district in Denver, Colorado, USA, equipped with a centralized air-source heat pump, distributed water-to-water heat pumps, and a central thermal storage unit. Results show that the tuned RBC attains approximately 96% of ideal MPC economic performance (-27% of costs), preserves values of technical and environmental indicators (reduction only of 2-3%), and substantially reduces complexity. Sensitivity analyses further demonstrate the robustness of the RBC under varying operational conditions (i.e., ambient temperature, electricity price). Overall, the study demonstrates that MPC-informed rule-based control represents an effective trade-off between control performance and real-world applicability, enabling the integration of additional system components while maintaining simplicity, robustness, and ease of implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

The value of integrating a geothermal district heating system into a microgrid

As electrical grids increasingly rely on variable renewable energy, maintaining reliability and cost efficiency becomes more complex. To address these challenges, this study analyzed the integration of geothermal district heating as a grid-responsive thermal resource within a microgrid in Tuttle, Oklahoma. Building energy modeling using EnergyPlus estimated annual district heating demand at 2.9 GWh, with a peak load of 2.8 MW th . Techno-economic analyses were conducted to meet the heating demand under three geothermal scenarios, varying by production depth, flow rate, and thermal output, each supplemented by natural gas peaking boilers. In parallel, equivalent electrical load profiles were developed using typical coefficients of performance (COPs) for air-source heat pumps and electric boilers to establish an electrified baseline scenario. A complete end-use electrical load profile was also developed for the microgrid using Cambium dataset. The modeling results demonstrated reliable and economic operation of the geothermal systems over 30 years, with COPs ranging from 2.6 to 8.9 and the lowest levelized heating cost at $\$$54.6/MWh. Geothermal integration reduced electricity consumption by up to 94.7 % compared to the non-geothermal base case, yielding annual energy savings of up to $\$$803 k. Avoided grid costs ranged from $\$$65 k–$\$$147 k per year, with individual events avoiding up to $\$$4,863 per hour. Grid-responsive operation further reduced wholesale energy costs by 53–56 %. These findings demonstrate geothermal heating, traditionally treated as a non-grid-responsive thermal resource, can be reconfigured to support dynamic grid services, offering a scalable pathway to enhance reliability and reduce costs in renewable-rich microgrids and district heating networks.

15 GEOTHERMAL ENERGY

Coalition for Community-Supported Affordable Geothermal Energy Systems (C2SAGES)

The C2SAGES project evaluated the feasibility of a community geothermal system for the planned Windy Ridge affordable housing development in Hinesburg, Vermont. Led by GTI Energy with Vermont Gas Systems, LN Consulting, NREL, and Frontier Energy, the work assessed technical design, energy performance, costs, business models, community engagement, maintenance, workforce development, and permitting. The proposed system was designed to serve 100% of the development’s heating, cooling, and domestic hot water loads. Compared with a baseline using air-source heat pumps and natural gas water heating, the geothermal system was estimated to reduce HVAC and domestic hot water energy use by about 45% to 48%, lower operating and maintenance costs, and reduce 30-year life-cycle costs by 37% for Phase 1 and 10% for Phase 2. Technical testing and modeling indicated that the Windy Ridge site is suitable for a community-scale geothermal system. The project also developed borehole field layouts, piping concepts, pump house designs, controls, maintenance plans, and supporting engineering drawings. The business model analysis found that first cost, ownership structure, and customer affordability remain major deployment challenges. Utility-led maintenance and operation were viewed favorably, but traditional utility cost-recovery models may require subsidy or revised financing structures to be practical for affordable housing. Community engagement highlighted the need for clear public education, transparent financing, reliable long-term maintenance, trained technicians, and the potential to pair geothermal systems with weatherization. Overall, the report concludes that community geothermal is technically feasible and offers meaningful energy, emissions, and life-cycle cost benefits, but broader deployment will depend on workable financing models and workforce readiness.

15 GEOTHERMAL ENERGY

Impacts of Electric Space Heating in Multifamily Apartments in Juneau, Alaska [Slides]

The study objective was to understand the change in electrical consumption and cost after the addition of a ductless mini-split air-source heat pump (ASHP) across rental apartments heated by electrical resistance heating systems in multifamily buildings in Juneau, Alaska. Alaska Electric Light and Power Company (AELP), the utility in Juneau, Alaska, funded installation of 19 heat pumps across four buildings. Using electrical meter interval data, including the total apartment consumption and submeter data for each heating appliance (electric resistance baseboard and heat pump), the National Laboratory of the Rockies (NLR) calculated energy use metrics before and after heat pump installation and visualized results. Through this research, NLR compares electrical use (total and specific to heating appliances), adjusted for weather and apartment size, and electrical demand in the year before and after installation of an ASHP across study units. The results will inform the utility and residents of documented energy and cost savings from transitioning building heating systems to a higher-efficiency electricity-based appliance, deliver a basis for building energy modeling across other multifamily housing dwellings, and enable estimates of potential electricity savings to AELP grid under widespread adoption scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Optimizing Heat Recovery with Storage: Control Validation and Sensitivity Analysis of the Time-Independent Energy Recovery Plant Using Modelica

Heat recovery in large building central plants saves energy but traditionally requires simultaneous heating and cooling. The Time-Independent Energy Recovery (TIER) plant shifts this paradigm by integrating thermal energy storage (TES) to enable heat recovery regardless of concurrent demand, offering a highly efficient, space-saving solution to achieve California’s energy goals. However, its integration of heat recovery chillers, cooling-only chillers, cooling towers, and trim air-source heat pumps (ASHPs) creates growing control and sizing complexity. To overcome this, this study employs high-fidelity Modelica dynamic simulation to validate TIER control sequences and optimize equipment sizing. We translated the written Sequences of Operation into executable Control Description Language (CDL) to test logic against sub-hourly loads. This verification workflow successfully identified and resolved critical vulnerabilities, such as thermal storage freezing and equipment short-cycling, in a virtual environment prior to physical deployment. Then, the study analyzes TIER plant performance across three simulated building types in three locations, and a real building load profile, ensuring variety in heating and cooling loads, and simultaneity factors and explores sizing rules for the TES and ASHP capacity. The analysis shows that the TIER plant operates equipment efficiently leading to a plant SCOP of around 7.5 across all scenarios, higher than a traditional ASHP plant, and a viable pathway to de-risk complex system design and control through simulation to identify optimal designs that maximize energy efficiency, minimize operational costs, and ensure robust operation in varied environmental conditions, thereby facilitating the broader adoption of such a solution for large buildings.

Zanetti, Ettore

REopt Federal User Support Session Two

This presentation is for FEMP's second user support session for federal REopt users. These sessions cover topics such as: overviews of REopt capabilities, hands-on REopt trainings and demonstrations, discussion and feedback about the tool and user support, federal REopt case studies and success stories, and links to REopt resources. This particular session covers discussion about federal onsite energy projects and challenges, using REopt to evaluate air-source and geothermal heat pumps, a federal success story about using REopt for heat pump analysis, a summary of available resources, and open question and answer session.