Search NASA⌕ Search

SEARCH · Search NASA

Results for “air_temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Investigating the Combustion Performance of Dual Fuel Combustion with Diesel and Port Injected Hydrogen in a Large Bore Locomotive Engine

The heavy-duty transportation sector has primarily relied on conventional diesel combustion engines given their reliability and high thermal efficiency relative to spark ignition engines, but increased focus on reducing greenhouse gas emissions has led to investigation into alternative fuels. Gaseous hydrogen fuel has garnered a great deal of recent interest in the engine community given it has zero carbon, but hydrogen is not available at the scale and cost that petroleum fuels are currently available, and this is a barrier to adoption for industries that are looking to decarbonize their operations. Because of the fuel flexibility provided, dual fuel technology offers a pathway for some industries to adopt hydrogen as a fuel source while maintaining sufficient flexibility in times and locations where the new fuel is not yet available. This computational study investigates dual fuel combustion in a large bore locomotive engine architecture using direct injected diesel and port injected gaseous hydrogen fuel. With an optimal port fuel injection configuration from previous work, simulations of varying substitution ratio, compression ratio, manifold air temperature, diesel injection timing, and diesel injection pressure were performed to understand their effect on combustion performance. Results indicated that both increased substitution ratio and higher intake air temperature accelerates hydrogen flame propagation and can result in high peak cylinder pressures. Additionally, diesel injection timing and injection pressure were demonstrated as effective methods for controlling dual fuel combustion heat release rates.

ODonnell, Patrick Christopher↗

Fuel injector design for high temperature aircraft engine

The objective of the Innovative High Temperature Aircraft Engine Fuel Nozzle Program was to design and evaluate a nozzle capable of operating at a combustor inlet air temperature of 1600 F (1144 K) and a fuel temperature of 350 F (450 K). The nozzle was designed to meet the same performance requirements and fit within the size envelope of a current production dual orifice fuel nozzle. The design approach was to use improved thermal protection and fuel passage geometry in combination with fuel passage surface treatment to minimize coking at these extreme fuel and air temperatures. Heat transfer models of several fuel injector concepts were used to optimize the thermal protection, while sample tube coking tests were run to evaluate the effect of surface finish, coatings and tube material on the coking rate. Based on heat transfer analysis, additional air gaps, reduced fuel passage flow area and use of ceramic tip components reduced local fuel wetted wall temperatures by more than 200 F (100 K) when compared to a current production fuel nozzle. Sample tube coking test results showed the importance of surface finish on the fuel coking rate. Therefore, a one micro-inch (0.025 micron) roughness was specified for all fuel passage surfaces. A novel flow divider valve in the tip was also employed to reduce weight, allow room for additional thermal protection, and provide back pressure to reduce the risk of fuel vaporization. The fuel nozzle was fabricated and evaluated in a series of high temperature coking tests. Initial results of these tests indicate that thermal protection and surface treatments were partially successful in preventing nozzle fouling, but additional refinement of the internal flowpath is needed to prevent buildup of coke particles that partially blocked the spin slots which meter the nozzle fuel flow.

R. W. Stickles↗

Using Satellite Surface Temperature Data to Monitor Urban Heat Island

Exposure to heat is a growing concern nationwide. Temperatures can be elevated in cities compared to surrounding rural areas, referred to as an “urban heat island” (UHI) effect, which is intensified during heat waves. The lack of dense networks of air temperature measurements results in few studies on urban heat. Now, a vast amount of high spatial and temporal satellite data on land surface temperature is available. We identified satellite datasets with the longest surface temperature records but different spatial and temporal resolutions: Landsat (1985-current, biweekly at 60 m and 100 m spatial resolution) and the Moderate Resolution Imaging Spectroradiometer (MODIS) data from the Terra and Aqua satellites (2000-current, daily at 1 km spatial resolution). We investigated how satellites with different spatial and temporal resolutions detect UHI effects differently. We hypothesized that 1) a dataset’s spatial resolution impacts the precision of detected UHIs spatially, since high spatial resolution Landsat data better captures spatial variability in temperature, and 2) daily surface temperature data can detect temporal patterns of UHIs and heatwave frequencies. We analyzed Landsat and MODIS satellite data in the Washington, D.C. and Baltimore region. We found that Landsat describes higher spatial variability of the UHI effect than MODIS data. However, MODIS data shows more consistent seasonal surface temperature patterns than Landsat when compared to in situ air temperature measurements. MODIS data was also able to consistently measure the frequency of heat waves. This study demonstrates the value of NASA satellite data for urban heat and climate change studies.

landsat↗

Improving energy efficiency while reducing anthropogenic heat from buildings: how retrofits influence the building stock and urban microclimate in Los Angeles

Anthropogenic heat (AH) from buildings contributes to urban overheating, especially during heat waves, yet building retrofit studies usually evaluate energy savings without assessing impacts on AH. This study quantifies how common building retrofit measures affect both building energy use and AH emissions across the City of Los Angeles. Using a bottom-up urban building energy modeling framework coupled with high-resolution local weather from the Weather Research and Forecasting model with Building Effect Parameterization (WRF-BEP), we evaluate eleven retrofit measures and two multi-measure retrofit packages. HVAC and LED lighting retrofits provide the largest city-wide annual site energy savings, while roof coating is most effective for reducing AH. A package optimized for energy savings reduces summer site energy use by about 32% (2.3 TWh), while a package incorporating AH-focused measures reduces the total AH by over 50% (137 PJ) with minimal difference in energy savings. The AH-aware package produces substantially greater urban cooling, reducing mean near-surface air temperature by up to 0.62 ℃ and peak temperature by up to 3.79 ℃. These results show that retrofit strategies selected only for energy savings may overlook major opportunities for urban heat mitigation. The study provides a framework for integrating AH into building retrofit planning and urban heat resilience policy.

Anthropogenic heat↗

Coupled heat and mass transfer in internally cooled silica gel-coated aluminum foam heat exchangers for dehumidification

Solid desiccant dehumidifiers offer significant potential to improve humidity control in buildings due to their ability to independently regulate latent (humidity) and sensible (temperature) loads. However, adsorption of water vapor by desiccants is an exothermic process; the resulting heat of adsorption increases both the desiccant bed temperature and the temperature of the air flowing over the bed, thereby limiting the performance of desiccant dehumidifiers. To address this problem, desiccant-coated heat exchanger prototypes were developed by coating silica gel onto aluminum foam substrates and integrated with chilled water circulation for effective removal of the heat of adsorption. Prototype heat exchangers with two different pore densities (10 and 20 pores per inch (PPI)) and two different desiccant loadings (∼10.36% and ∼17.80%) were fabricated. Experiments were conducted by varying the inlet air face velocity, chilled water inlet temperature, and chilled water flow rate to investigate the coupled heat and mass transfer characteristics of the prototype heat exchangers over a wide range of operating conditions. The underlying transport mechanisms were analyzed using transient desiccant bed temperature, outlet air temperature, and outlet humidity profiles. The results demonstrate that internal cooling significantly enhances dehumidification performance by maintaining more favorable thermodynamic conditions for water vapor adsorption. Under identical operating conditions, a 20 PPI heat exchanger coated with 25.05 g of silica gel achieved 98.98% higher cumulative water uptake and 97.75% higher moisture removal capacity than the corresponding non-cooled case after 5 min of adsorption. This substantial enhancement was further supported by a validated one-dimensional coupled heat and mass transfer model developed in the present study. To date, this is one of the first experimental studies to systematically investigate the combined effects of internal cooling, foam pore density, and desiccant loading on the performance of silica-gel-coated metal foam heat exchangers under HVAC-relevant operating conditions.

42 ENGINEERING↗

Measuring Climate and Water Risk across the Bulk Power System

As climate impacts increase and power systems transition to renewables, planners and operators need insights into climate risks to power generation and infrastructure to ensure reliable decision-making in the short and long-term. We present a standardized, consistent mechanism for utilities and system operators to evaluate the climate- and water-related risks of their current and future grid assets. Using a risk-based approach on the combined outcomes of high-fidelity climate drivers together with water and power system models, we examine the temperature and water availability impacts within the contiguous United States to power system assets at the water basin level in three different time periods and report resulting outcomes on lost capacity across different expansion scenarios and climate models. The results indicate that air temperature has the highest effect on derating. Changes in streamflow do not have a large impact on generation capacity at the national level. Electric sector buildout scenarios each have a unique regional risk profile, depending on the technology mix and total capacity, although risks from high temperatures are significant for both traditional and renewable energy generation. Stakeholders can use this approach to monitor effects of generation capacity losses and potential impacts as climate, generation mix, and infrastructure change.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Heat metrics and thresholds reshape population exposure and inequality signals

Extreme heat is intensifying worldwide, yet estimates of heat hazard and exposure inequality depend on both the heat metric and how extreme days are defined. Using summer 2022 across the Mediterranean, we quantify population heat exposure with four metrics—land surface temperature (LST), air temperature (Ta), heat index (HI), and wet-bulb globe temperature (WBGT)—under absolute (fixed-value) and relative (anomaly-based) thresholds. Under absolute thresholds, total heat exposure differs by more than two orders of magnitude across metrics (31.3 billion person-days for Ta vs 0.3 billion for HI). Geographic hotspots also diverge: WBGT concentrates in humid coastal North Africa (e.g. the Nile Delta), whereas Ta and LST are more widespread. Under relative thresholds, exposure totals converge and cross-metric hotspot agreement increases (e.g. Ta–WBGT top-tercile overlap increases from 10.7% to 29.0%), shifting hotspots toward densely populated southern Europe. Crucially, the exposure–deprivation relationship also reverses across threshold frameworks: absolute thresholds concentrate exposure in more deprived North Africa and the Middle East, whereas relative thresholds shift the burden toward less-deprived European cities. This sensitivity is decision-relevant: city rankings based on WBGT exposure duration are almost completely reordered when switching threshold frameworks. Threshold choice therefore systematically reshapes hotspot patterns and inequality signals. Reporting both absolute and relative exposures can reveal hidden hotspots and support more targeted heat-risk monitoring and intervention planning.

Mediterranean↗

Snow-eater heat waves of the western United States

Abrupt snowmelt, triggered by rain-on-snow events or "snow-eater heat waves," can cause flooding, initiate or accelerate snow drought, and affect water availability. However, the characteristics (e.g., area, duration, and frequency), impacts, and trends of snow-eater heat waves have received little attention. To address this gap, we developed a method to identify snow-eater heat waves and estimate their melt potential using 20th Century Reanalysis version 3 air temperature data, the TempestExtremes algorithm, and an operational snowmelt model (SNOW-17) across 1850-2015. Melt season snow-eater heat waves typically last 3 to 5 days, with three to five events, doubling snowmelt rates. Seven of 11 spring superfloods are shown to coincide with snow-eater heat waves. Since the 1850s, snow-eater heat waves have increased in area and frequency, decreased in duration, and shifted earlier in the melt season. Incorporating snow-eater heat-wave impacts into SNOW-17 enhances extreme melt estimates, improving water management support tools.

Rhoades, Alan M↗

Warming amplifies the variability of methane emissions from a coastal wetland, 2025, Maryland.

These data accompany the published paper Lewis et al., 202X and are from a brackish coastal wetland in situ soil warming experiment (GENX) equipped with automated flux chambers. Methane (CH4) and carbon dioxide (CO2) fluxes were measured in 12 automated chambers using custom-built automated chambers connected to an LI-7810 CH4/CO2 analyzer. The chambers are 1.5 m tall and contain the dominant vegetation species of the site (Schoenoplectus americanus, Spartina patens, and Distichlis spicata). The chambers are also distributed across a soil warming gradient, ranging from ambient to 6°C above ambient, that was started in February 2022. This dataset contains the following files: (1) CH4 and CO2 fluxes from each chamber for March to November 2025, statistics for each flux, and environmental data (water depth, salinity, air temperature) at the time of the flux measurement; (2) 15-minute soil temperature data for each chamber; (3) Aboveground vegetation biomass (total and by species) and stem counts and dimensions for S. americanus; (4) Elevation for each chamber. All data processing code is available on Github.

Coastal wetland↗

Enter the AHU (36th Chamber of ASHRAE): A Multi-site Field Study of ASHRAE G36

Despite being recognized as the best practice for advanced building controls, ASHRAE Guideline 36 (G36) has seen slow adoption in retrofit cases. Decisionmakers lack credible field evidence to justify the time and person-power investment. Most prior analyses have relied on software simulations, which overlook implementation challenges and fail to persuade owners to move from models to real-world deployment. This paper presents a multi-site field study of G36 performance, drawing on measured results from 17 projects across diverse building types and climate zones. The analysis disaggregates outcomes by the most widely adopted air handling unit (AHU) based G36 strategies, including trim-and-respond approaches to supply air temperature (SAT) and duct static pressure (DSP) reset, and economizer controls. Results for controls re programming implementations are encouraging, with HVAC savings ranging from 2% - 49%, with a median of 18%. The range aligns with simulation study findings showing 1% - 46% savings through these three strategies. These findings show that even without capital investment in control infrastructure upgrades, existing building owners are reaping significant benefits from updating HVAC sequences of operation to industry best-practice solutions. The results give practitioners and decisionmakers a reference point on what to expect, which strategies deliver, and how field performance may compare to simulation.

Deshpande, Reva↗

High-Resolution WRF-Based Downscaling of Earth System Model Projections for Energy Applications across CONUS

Evaluating energy resources under future scenarios requires meteorological information that adequately resolves regional-scale variability and is suitable for regional energy system studies. Although Earth system model (ESM) outputs provide essential large-scale context, their coarse resolution and inherent biases limit direct use in energy system applications. This work presents a high-resolution dynamical downscaling framework using the Weather Research and Forecasting (WRF) model to generate energy-relevant regional fields for future scenarios over the contiguous United States (CONUS). The framework first identifies an optimal WRF configuration through sensitivity experiments, then evaluates raw and bias-corrected ESM initial and boundary conditions, with soil moisture and soil temperature bias correction implemented as an integral component of the bias-corrected ESM atmospheric forcing prior to WRF dynamical downscaling to improve land-atmosphere interactions. Simulations performed at 4-km resolution show that uncorrected ESM forcing leads to systematically dry and cold soil states, which propagate into elevated near-surface air temperature and solar irradiance biases, particularly during summer for the period 2000-2014. Incorporating bias-corrected atmospheric forcing together with soil state bias correction substantially reduces these errors and improves the representation of surface energy processes in WRF simulations. The results highlight the importance of bias-aware initialization strategies in high-resolution dynamical downscaling for future energy system analysis and planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Resolution ESM Projections for Energy Applications Over the CONUS

Assessing energy resources under future scenarios requires high-resolution meteorological information that is physically consistent and suitable for regional-scale analysis. While Earth system model (ESM) projections provide valuable large-scale information, their coarse resolution and systematic biases limit direct applicability for energy system modeling and planning. In this study, we develop a high-resolution dynamical downscaling framework based on the Weather Research and Forecasting (WRF) model to translate global-scale ESM data into energy-relevant regional projections over the contiguous United States (CONUS). The framework identifies an optimized WRF configuration through numerical experiments and evaluates raw and bias-corrected ESM initial and boundary conditions, with soil moisture (SM) and soil temperature (ST) bias correction implemented as an integral part of the bias-corrected ESM forcing to improve land-atmosphere coupling prior to WRF dynamical downscaling. Using an optimized WRF configuration at 4-km resolution, we show that raw ESM forcing introduces systematic dry and cold soil biases that propagate into pronounced warm biases in near-surface air temperature and positive biases in solar irradiance, particularly during summer. Applying bias-corrected atmospheric forcing together with bias-corrected SM and ST substantially reduces these downstream biases and improves the surface energy balance and near-surface atmospheric fields. These results demonstrate that bias-aware treatment of initial conditions is critical for producing high-resolution downscaled projections suitable for energy system modeling and planning applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Future of Oaks in the Santa Monica Mountains: A Case Study in Using Remote Sensing Data for Species Distributions Models

The Woolsey Fire began on November 8, 2018, and lasted for almost two weeks, during which it burned almost 100,000 acres of valuable landscape and habitat, including a vast area of woodland. The persistence of key woodland species provides aesthetic, monetary, and ecological value to the landscape through carbon sequestration, air temperature moderation, and erosion mitigation, among other ecosystem services. This study investigated the impact of the Woolsey Fire on native woodland species distributions and identified areas suitable for restoration within the Santa Monica Mountains National Recreation Area. The team partnered with the Resource Conservation District of the Santa Monica Mountains; National Park Service, Santa Monica Mountains National Recreation Area; California Department of Parks and Recreation, Los Angeles County Division; County of Los Angeles Fire Department, Prevention Services Bureau, Forestry Division; County of Los Angeles Department of Regional Planning; and the University of Montana. The Earth observations used include data from Landsat 8 Operational Land Imager, NASA ER-2 Jet Airborne Visible InfraRed Imaging Spectrometer, Shuttle Radar Topography Mission, and RapidEye. The team produced maps of burn severity from the Woolsey Fire, its impact on plant species distributions, and habitat suitability projections for 2050 and 2099 to assist partners in prioritizing areas for restoration. A plant community classification was successfully created using Multiple Endmember Spectral Mixture Analysis (MESMA). Overall accuracy was assessed at 90.54% by comparing the classification to validation pixels derived from ground truth information provided by our partners.

Roger Ly↗

Operational Correction for the Temperature Dependence of A Class of Hyperspectral Radiometers

The correction for temperature response of optical radiometers implies access to their working temperature (i.e., either the internal or ambient one with the radiometers in thermal equilibrium). With specific reference to a class of widely used hyperspectral radiometers lacking a thermistor to measure the internal temperature, this work investigated the potential for operational corrections relying on the ambient temperature derived from the radiometer dark digital counts. With the objective to keep within approximately 1% the uncertainty for radiometric corrections in the 400–800-nm spectral range, findings showed the applicability of the method for ambient temperatures higher than approximately 30°C. The alternative use of an ambient temperature proxy, determined from the air temperature incremented by a few degrees Celsius, was shown a valid solution to constrain the uncertainty of radiometric corrections to within 1% over the entire 0°–40°C interval.

Giuseppe Zibordi↗

Satellite characterization of global stratospheric sulfate aerosols released by Tonga volcano

Large volcanic eruptions create an enhanced layer of sulfate aerosols in the stratosphere. These sulfuric acid droplets persist for many months, altering the climate and stratospheric chemistry. Sulfate aerosols scatter sunlight back to space, cooling the surface of the Earth and absorb outgoing thermal radiation, heating the stratosphere. The calculation of the climate impact of sulfate aerosols depends on their physical properties such as droplet size and chemical composition. These properties are not well known, and this uncertainty contributes to the errors in climate model predictions. Here we derive the first empirical formula that predicts the composition of stratospheric sulfate aerosols from volcanic eruptions from the air temperature and water vapor pressure. Measurements of atmospheric infrared transmittance of the Hunga Tonga-Hunga Ha'apai sulfate aerosol plume by the Atmospheric Chemistry Experiment (ACE) satellite were analyzed to determine composition (weight percent of sulfuric acid) and median particle radius. These data are supplemented by measurements of the Raikoke and Nabro eruptions. Our analysis allows the properties of volcanic aerosols in the stratosphere to be predicted reliably in atmospheric models.

P Bernath↗

Petermann Glacier on the Brink: Progress, Challenges and Insights

Petermann Glacier, the largest marine-terminating glacier in northern Greenland based on catchment area and ice discharge, plays a key role in regulating ice discharge from the Greenland Ice Sheet into the Arctic Ocean. With an upstream catchment connected to the ice sheet interior via a deep subglacial canyon, its future stability has major implications for sea level rise. In this review, we synthesize recent advances in understanding Petermann’s dynamics across three critical interfaces: the ice–ocean, ice–atmosphere, and ice–bed boundaries. At the surface, observations show that reanalysis products underestimate air temperatures and melt, while regional climate models diverge significantly in their estimates of surface mass balance, underscoring the need for improved in situ data and models. At the ocean boundary, enhanced basal melting driven by both subglacial runoff and Atlantic water intrusions is identified as the dominant driver of recent mass loss of Petermann Glacier, with continued warming posing a serious threat to the stability of the floating tongue. At the bed, new geophysical synthesis reveals complex geology, likely spatial variability in geothermal heat flux, and the influence of the megacanyon on seasonal hydrology and velocity fluctuations. Petermann’s mass balance has been negative in recent decades without corresponding flow acceleration. However, the glacier has undergone significant calving events, and the current rifting that began in September 2025 highlights its vulnerability. This upcoming calving event underscores the timeliness of this review, as it will put Petermann Glacier’s terminus at its most retreated position since records began in 1923. The anticipated retreat of the ice tongue also reduces buttressing and brings the terminus closer to the grounding zone, and modeling studies suggest that calving within 12 km of the grounding zone could potentially trigger dynamic retreat, accelerating ice discharge, and a doubling of flow speeds. We conclude that improved observations, sustained monitoring of oceanographic and atmospheric properties, and high-resolution modeling are critical to constraining projections of Petermann Glacier’s future and its role in the stability of the Greenland Ice Sheet.

Dominik Fahrner↗

Field Demonstration and Adoption Impacts of an Affordable Thermoelectric Heat Pump

This study presents the design, field validation, and utility impacts of an air source heat pump that uses thermoelectric (TE) technology to provide supplemental heating at outside air temperatures below 17°F. Conventional heat pumps experience reduced heating capacity and COP at low outdoor temperatures due to the temperature difference between the source and demand sides of the vapor compression cycle. Consequently, during colder months, supplemental heating such as electric resistance or natural gas furnace is often needed to provide additional warmth, which increases the overall equipment and energy costs. To address this challenge, a TE subcooler (an array of solid-state, thermoelectric modules that provides heat pumping using non-vapor compression technique) is fabricated and integrated with the vapor compression cycle of a conventional air-source heat pump. In colder ambient conditions, TE subcooler exchanges heat with the refrigerant to provide additional subcooling, thereby enhancing the capacity of the heat pump. The operation of thermoelectric-integrated heat pump was demonstrated in an occupied single-family home in Nashville, TN. The TE subcooler increased the system’s heating capacity at 15°F outdoor temperature by 25–30% and reduced electricity demand by 10%. It also met the heating load in the house without supplemental electric resistance down to 5°F outdoors, delivering the additional heat at nearly 80% greater efficiency compared to electric resistance heating. With a modest first cost increment of 10–15% over conventional single-speed heat pumps, this approach offers a promising, energy-efficient solution to accelerate residential heat pump adoption in the U.S.

KRISHNAMOORTHY, Sreenidhi [Electric Power Research↗

Automated point dendrometer, soil moisture and temperature, and meteorological variables datasets, Oct 2024 – Nov 2025, G.A. Pearson Natural Area, Flagstaff, AZ, USA

This data package includes parsed, cleaned, and calibrated data from 48 TOMST automated point dendrometers, 48 TOMST 15 cm soil moisture sensors, and 12 TOMST 30 cm soil moisture sensors. The point dendrometers were cleaned with the “dendRoAnalyst” package in RStudio. The soil sensors were cleaned and calibrated for volumetric water content (VWC) with the “myClim” package in RStudio using the soil texture of the site (sandy clay loam). Additionally, this data package also includes raw data from 2 METER weather stations. Dendrometers and soil sensors have both their sensor ID, as well as the ID for the specific tree they were instrumented on at the G.A. Pearson Natural Area (GPNA) site and their experimental group. The purpose of these data is to understand how ponderosa pine trees in restored (thinned and burned) vs. unrestored (no treatment) areas are responding to drought and seasonal precipitation. These data use radial growth and soil moisture data to answer the following question: how are active season length, growth on different time scales (weekly, monthly, seasonally, and annually), growth during dry periods and after precipitation events, and environmental and biological drivers of radial growth different between restored versus unrestored areas?

Air temperature↗