Search NASASearch

SEARCH · Search NASA

Results for “alarms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Employing Eye Trackers to Reduce Nuisance Alarms

When process operators anticipate an alarm prior to its annunciation, that alarm loses information value and becomes a nuisance. This study investigated using eye trackers to measure and adjust the salience of alarms with three methods of gaze-based acknowledgement (GBA) of alarms that estimate operator anticipation. When these methods detected possible alarm anticipation, the alarm’s audio and visual salience was reduced. A total of 24 engineering students (male = 14, female = 10) aged between 18 and 45 were recruited to predict alarms and control a process parameter in three scenario types (parameter near threshold, trending, or fluctuating). The study evaluated whether behaviors of the monitored parameter affected how frequently the three GBA methods were utilized and whether reducing alarm salience improved control task performance. The results did not show significant task improvement with any GBA methods (F(3,69) = 1.357, p = 0.263, partial η 2 = 0.056). However, the scenario type affected which GBA method was more utilized (X 2 (2, N = 432) = 30.147, p < 0.001). Alarm prediction hits with gaze-based acknowledgements coincided more frequently than alarm prediction hits without gaze-based acknowledgements (X 2 (1, N = 432) = 23.802, p < 0.001, OR = 3.877, 95% CI 2.25–6.68, p < 0.05). Participant ratings indicated an overall preference for the three GBA methods over a standard alarm design (F(3,63) = 3.745, p = 0.015, partial η 2 = 0.151). This study provides empirical evidence for the potential of eye tracking in alarm management but highlights the need for additional research to increase validity for inferring alarm anticipation.

99 - GENERAL AND MISCELLANEOUS

Memo on Speech Alarms: Replication and Validation of Results

Caution and warning (C&W) alarms help people to quickly and efficiently identify situations that are of immediate danger or would escalate to a safety critical level. Tones are highly salient and have been traditionally used for caution and warning alarms. However, research shows that tone alarms can have an unwanted startle effect that hinders operator decision making. Speech alarms are good alternatives to tone alarms because they require less training and are less startling. They have been in use for decades for caution and warning systems in commercial airplanes and in buildings. Speech alarms have been considered for space flight use by the National Aeronautics and Space Administration’s (NASA) Astronaut Office and by its Orion Program. To investigate whether performance with various types of speech alarms was similar to performance with the currently used tone alarms, a study was conducted in 2010. The results showed faster identification times of speech alarms as well as higher acceptance rates from participants. However, the presentation of the alarms had a variable onset time due to software. The current research project was funded to address this issue by collecting new data with alarms having nonvariable onset time and to validate the alarms in the Human Exploration Research Analog (HERA). This report describes the two studies: a laboratory experiment comparing tone and speech alarms, and an evaluation in the HERA facility.

warning signals

Remote Monitor Alarm System

A remote monitor alarm system monitors discrete alarm and analog power supply voltage conditions at remotely located communications terminal equipment. A central monitoring unit (CMU) is connected via serial data links to each of a plurality of remote terminal units (RTUS) that monitor the alarm and power supply conditions of the remote terminal equipment. Each RTU can monitor and store condition information of both discrete alarm points and analog power supply voltage points in its associated communications terminal equipment. The stored alarm information is periodically transmitted to the CMU in response to sequential polling of the RTUS. The number of monitored alarm inputs and permissible voltage ranges for the analog inputs can be remotely configured at the CMU and downloaded into programmable memory at each RTU. The CMU includes a video display, a hard disk memory, a line printer and an audio alarm for communicating and storing the alarm information received from each RTU.

Stute, Robert A.

Multiple-Parameter, Low-False-Alarm Fire-Detection Systems

Fire-detection systems incorporating multiple sensors that measure multiple parameters are being developed for use in storage depots, cargo bays of ships and aircraft, and other locations not amenable to frequent, direct visual inspection. These systems are intended to improve upon conventional smoke detectors, now used in such locations, that reliably detect fires but also frequently generate false alarms: for example, conventional smoke detectors based on the blockage of light by smoke particles are also affected by dust particles and water droplets and, thus, are often susceptible to false alarms. In contrast, by utilizing multiple parameters associated with fires, i.e. not only obscuration by smoke particles but also concentrations of multiple chemical species that are commonly generated in combustion, false alarms can be significantly decreased while still detecting fires as reliably as older smoke-detector systems do. The present development includes fabrication of sensors that have, variously, micrometer- or nanometer-sized features so that such multiple sensors can be integrated into arrays that have sizes, weights, and power demands smaller than those of older macroscopic sensors. The sensors include resistors, electrochemical cells, and Schottky diodes that exhibit different sensitivities to the various airborne chemicals of interest. In a system of this type, the sensor readings are digitized and processed by advanced signal-processing hardware and software to extract such chemical indications of fires as abnormally high concentrations of CO and CO2, possibly in combination with H2 and/or hydrocarbons. The system also includes a microelectromechanical systems (MEMS)-based particle detector and classifier device to increase the reliability of measurements of chemical species and particulates. In parallel research, software for modeling the evolution of a fire within an aircraft cargo bay has been developed. The model implemented in the software can describe the concentrations of chemical species and of particulate matter as functions of time. A system of the present developmental type and a conventional fire detector were tested under both fire and false-alarm conditions in a Federal Aviation Administration cargo-compartment- testing facility. Both systems consistently detected fires. However, the conventional fire detector consistently generated false alarms, whereas the developmental system did not generate any false alarms.

Hunter, Gary W.

Field-based AFDD for refrigerant undercharge in residential HVAC systems: enhancing reliability through false alarm mitigation

This study evaluated rule-based and machine learning (ML) based automated fault detection and diagnostics (AFDD) algorithms for detecting refrigerant undercharge faults in residential heating, ventilation, and air conditioning (HVAC) systems, using actual building data and a minimal set of features. The ML-based algorithms included Decision Tree (DT) and K-Nearest Neighbors (KNN). Both the rule-based and ML-based algorithms demonstrated the capability to detect refrigerant undercharge faults of -30% or more. Both types of algorithms exhibited false alarms before the implementation of a false alarm mitigation algorithm, which motivated the development of such a mitigation strategy. After applying the mitigation, false alarms were substantially reduced, with the rule-based algorithm decreasing to 0.6% and the ML-based algorithms reaching 0%, while maintaining strong detection performance. Although the rule-based algorithm initially showed lower performance compared to the ML-based algorithms, its detection accuracy improved after mitigation to a level comparable to the ML-based algorithms. These results confirm that combining false alarm mitigation with both rule-based and ML-based AFDD algorithms significantly enhances practical reliability while preserving robust fault detection capabilities. Furthermore, the findings demonstrate the potential for field deployment of these algorithms in residential HVAC systems and highlight the importance of minimizing false alarms.

False Alarm

Speech Alarms Pilot Study

Currently on the International Space Station (ISS) and other space vehicles Caution & Warning (C&W) alerts are represented with various auditory tones that correspond to the type of event. This system relies on the crew's ability to remember what each tone represents in a high stress, high workload environment when responding to the alert. Furthermore, crew receive a year or more in advance of the mission that makes remembering the semantic meaning of the alerts more difficult. The current system works for missions conducted close to Earth where ground operators can assist as needed. On long duration missions, however, they will need to work off-nominal events autonomously. There is evidence that speech alarms may be easier and faster to recognize, especially during an off-nominal event. The Information Presentation Directed Research Project (FY07-FY09) funded by the Human Research Program included several studies investigating C&W alerts. The studies evaluated tone alerts currently in use with NASA flight deck displays along with candidate speech alerts. A follow-on study used four types of speech alerts to investigate how quickly various types of auditory alerts with and without a speech component - either at the beginning or at the end of the tone - can be identified. Even though crew were familiar with the tone alert from training or direct mission experience, alerts starting with a speech component were identified faster than alerts starting with a tone. The current study replicated the results from the previous study in a more rigorous experimental design to determine if the candidate speech alarms are ready for transition to operations or if more research is needed. Four types of alarms (caution, warning, fire, and depressurization) were presented to participants in both tone and speech formats in laboratory settings and later in the Human Exploration Research Analog (HERA). In the laboratory study, the alerts were presented by software and participants were asked to identify the alert as quickly and as accurately as possible. Reaction time and accuracy were measured. Participants identified speech alerts significantly faster than tone alerts. The HERA study investigated the performance of participants in a flight-like environment. Participants were instructed to complete items on a task list and respond to C&W alerts as they occurred. Reaction time and accuracy were measured to determine if the benefits of speech alarms are still present in an applied setting.

Sandor, A.

Multiple meter monitoring circuits served by single alarm

Circuitry for multiple meter relay circuits provides complete isolation for each circuit served by a single alarm and permits alarm reset after an out-of-tolerance event in one relay circuit so that the remaining relay circuits continue to be alarm protected.

Bandini, U.

Control of ELT false alarms

The statistics of emergency locator transmitter (ELT) alarms are presented. The primary sources of data include ELT Incident Logs, Service Difficulty Reports, and Frequency Interference Reports. The number of reported and unreported alarms is discussed, as are seasonal variations, duration of ELT transmissions, and cost of silencing. Origin, causes, and possible strategies for reducing the impact of alarms on the aviation community are considered.

Toth, S.

SETI Pulse Detection Algorithm: Analysis of False-alarm Rates

Some earlier work by the Search for Extraterrestrial Intelligence (SETI) Science Working Group (SWG) on the derivation of spectrum analyzer thresholds for a pulse detection algorithm based on an analysis of false alarm rates is extended. The algorithm previously analyzed was intended to detect a finite sequence of i periodically spaced pulses that did not necessarily occupy the entire observation interval. This algorithm would recognize the presence of such a signal only if all i-received pulse powers exceeded a threshold T(i): these thresholds were selected to achieve a desired false alarm rate, independent of i. To simplify the analysis, it was assumed that the pulses were synchronous with the spectrum sample times. This analysis extends the earlier effort to include infinite and/or asynchronous pulse trains. Furthermore, to decrease the possibility of missing an extraterrestrial intelligence signal, the algorithm was modified to detect a pulse train even if some of the received pulse powers fall below the threshold. The analysis employs geometrical arguments that make it conceptually easy to incorporate boundary conditions imposed on the derivation of the false alarm rates. While the exact results can be somewhat complex, simple closed form approximations are derived that produce a negligible loss of accuracy.

Levitt, B. K.

Likelihood alarm displays

In a likelihood alarm display (LAD) information about event likelihood is computed by an automated monitoring system and encoded into an alerting signal for the human operator. Operator performance within a dual-task paradigm was evaluated with two LADs: a color-coded visual alarm and a linguistically coded synthetic speech alarm. The operator's primary task was one of tracking; the secondary task was to monitor a four-element numerical display and determine whether the data arose from a 'signal' or 'no-signal' condition. A simulated 'intelligent' monitoring system alerted the operator to the likelihood of a signal. The results indicated that (1) automated monitoring systems can improve performance on primary and secondary tasks; (2) LADs can improve the allocation of attention among tasks and provide information integrated into operator decisions; and (3) LADs do not necessarily add to the operator's attentional load.

Sorkin, Robert D.

Caution and Warning Alarm Design and Evaluation for NASA CEV Auditory Displays: SHFE Information Presentation Directed Research Project (DRPP) report 12.07

The design of caution-warning signals for NASA s Crew Exploration Vehicle (CEV) and other future spacecraft will be based on both best practices based on current research and evaluation of current alarms. A design approach is presented based upon cross-disciplinary examination of psychoacoustic research, human factors experience, aerospace practices, and acoustical engineering requirements. A listening test with thirteen participants was performed involving ranking and grading of current and newly developed caution-warning stimuli under three conditions: (1) alarm levels adjusted for compliance with ISO 7731, "Danger signals for work places - Auditory Danger Signals", (2) alarm levels adjusted to an overall 15 dBA s/n ratio and (3) simulated codec low-pass filtering. Questionnaire data yielded useful insights regarding cognitive associations with the sounds.

Durand R Begault

Recent Results on "Approximations to Optimal Alarm Systems for Anomaly Detection"

An optimal alarm system and its approximations may use Kalman filtering for univariate linear dynamic systems driven by Gaussian noise to provide a layer of predictive capability. Predicted Kalman filter future process values and a fixed critical threshold can be used to construct a candidate level-crossing event over a predetermined prediction window. An optimal alarm system can be designed to elicit the fewest false alarms for a fixed detection probability in this particular scenario.

Martin, Rodney Alexander

Evaluating Probability of Assessment for Central Alarm Station Operators

This project focused on developing and analyzing a method that could be employed by operational nuclear facilities to evaluate their CAS operators and determine a probability of assessment for each operator. This method is agnostic of alarm communication and display system (AC&D), sensors and cameras in place in the field, and any other technical security measures. This security-measure-agnostic method enables operational facilities to adopt it to determine the effectiveness of their alarm station operators.

42 ENGINEERING

Visual display and alarm system for wind tunnel static and dynamic loads

A wind tunnel balance monitor and alarm system developed at NASA Ames Research Center will produce several beneficial results. The costs of wind tunnel delays because of inadvertent balance damage and the costs of balance repair or replacement can be greatly reduced or eliminated with better real-time information on the balance static and dynamic loading. The wind tunnel itself will have enhanced utility with the elimination of overly cautious limits on test conditions. The microprocessor-based system features automatic scaling and 16 multicolored LED bargraphs to indicate both static and dynamic components of the signals from eight individual channels. Five individually programmable alarm levels are available with relay closures for internal or external visual and audible warning devices and other functions such as automatic activation of external recording devices, model positioning mechanisms, or tunnel shutdown.

Hanly, Richard D.

Visual display and alarm system for wind tunnel static and dynamic loads

A wind tunnel balance monitor and alarm system developed at NASA Ames Research Center will produce several beneficial results. The costs of wind tunnel delays because of inadvertent balance damage and the costs of balance repair or replacement can be greatly reduced or eliminated with better real-time information on the balance static and dynamic loading. The wind tunnel itself will have enhanced utility with the elimination of overly cautious limits on test conditions. The microprocessor-based system features automatic scaling and 16 multicolored LED bargraphs to indicate both static and dynamic components of the signals from eight individual channels. Five individually programmable alarm levels are available with relay closures for internal or external visual and audible warning devices and other functions such as automatic activation of external recording devices, model positioning mechanism, or tunnel shutdown.

Hanly, Richard D.

A new approach to importance sampling for the simulation of false alarms

In this paper a modified importance sampling technique for improving the convergence of Importance Sampling is given. By using this approach to estimate low false alarm rates in radar simulations, the number of Monte Carlo runs can be reduced significantly. For one-dimensional exponential, Weibull, and Rayleigh distributions, a uniformly minimum variance unbiased estimator is obtained. For Gaussian distribution the estimator in this approach is uniformly better than that of previously known Importance Sampling approach. For a cell averaging system, by combining this technique and group sampling, the reduction of Monte Carlo runs for a reference cell of 20 and false alarm rate of lE-6 is on the order of 170 as compared to the previously known Importance Sampling approach.

Lu, D.

Alarm- And Power-Monitoring System

Electronic central monitoring system, called Remote Monitor Alarm System, RMAS, used to monitor malfunction alarms and power supplies of remotely located equipment modules of transmitting and receiving equipment in fiber-optic communication network at Kennedy Space Center. Includes central monitoring unit at location convenient for technicians, plus remote terminal unit at each remote site containing equipment to be monitored.

Stute, Rob

Display-And-Alarm Circuit For Accelerometer

Compact accelerometer assembly consists of commercial accelerometer retrofit with display-and-alarm circuit. Provides simple means for technician attending machine to monitor vibrations. Also simpifies automatic safety shutdown by providing local alarm or shutdown signal when vibration exceeds preset level.

Bozeman, Richard J., Jr.