Search NASA⌕ Search

SEARCH · Search NASA

Results for “ambient ionization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Raman spectroscopy coupled with ambient ionization mass spectrometry: A forensic laboratory investigation into rapid and simple dual instrumental analysis techniques

We present a laboratory experiment, developed around a pair of instrumental analysis techniques, Raman spectroscopy and ambient ionization mass spectrometry (MS), conducted by senior chemistry undergraduate students for bulk analysis of over-the-counter drugs using benchtop versions of the two instruments, as well as trace analysis of illicit drugs utilizing the corresponding portable instruments. The identification and confirmation of seized drugs is a routine operation in forensic laboratories that can be simplified using these two instrumental techniques in tandem. Bulk samples are readily analyzed using conventional Raman spectroscopy followed by paper cone spray ionization (PCSI) MS, while trace analysis is allowed by a simple single-substrate dual-analyzer method using surface enhanced Raman spectroscopy (SERS) from paper followed by paper spray ionization (PSI) MS. The introduction of these novel strategies to the students exposed them to potential career paths in forensic science by means of a hands-on experience that provided fundamental knowledge about this set of analytical methods, including intercomparisons of their performance, as well as practical issues like costs, regulations and databases. The use of portable instrumentation represents an additional learning experience for the students, considering that it is cutting-edge technology that is just now being transferred from academic to industrial labs and that it allows a valuable discussion of the advantages and disadvantages of bringing the laboratory to the field.

47 OTHER INSTRUMENTATION↗

Characterization of a Low-Temperature Plasma (LTP) Ambient Ionization Source Using Temporally Resolved Monochromatic Imaging Spectrometry

The low-temperature plasma (LTP) probe is a common plasma-based source used for ambient desorption–ionization mass spectrometry (MS). While the LTP probe has been characterized in detail with MS, relatively few studies have used optical spectroscopy. In this paper, two-dimensional (2D) imaging at selected wavelengths is used to visualize important species in the LTP plasma jet. First, 2D steady-state images of the LTP plume for N 2 + (391.2 nm), He I (706.5 nm), and N 2 (337.1 nm) emissions were recorded under selected plasma conditions. Second, time-resolved 2D emission maps of radiative species in the LTP plasma jet were recorded through the use of a 200 ns detection gate and varying gate delays with respect to the LTP trigger pulse. Emission from He I, N 2 + , and N 2 in the plasma jet region was found to show a transient behavior (often referred to as plasma bullets) lasting only a few microseconds. The N 2 + and He I maps were highly correlated in spatial and temporal structure. Further, emission from N 2 showed two maxima in time, one before and one after the maximum emission for N 2 + and He I, due to an initial electronic excitation wave and ion–electron recombination, respectively. Third, the interaction of the LTP probe with a sample substrate and an electrically grounded metallic needle was studied. Emission from a fluorophore on the sample substrate showed an initial photon-induced excitation from plasma-generated photons followed by electronic excitation by other plasma species. The presence of a grounded needle near the plasma jet significantly extended the plasma jet lifetime and also generated a long-lived corona discharge on the needle. The effect of LTP operating parameters on emission spectra was correlated with mass-spectral results including reagent-ion signals. Lastly, five movies provide a side-by-side comparison of the temporal behavior of emitting species and insights into the interactions of the emission clouds with a sample surface as well as an external needle. Temporally and spatially resolved imaging provided insights into important processes in the LTP plasma jet, which will help improve analyte ion sampling in LTP–MS.

Chan, George C. -Y.↗

Active Humidity Control Chamber for Desorption Electrospray Ionization-Mass Spectrometry Imaging Applications

Ambient ionization techniques enable mass spectrometry (MS) to expand into broader experimental contexts, although it is increasingly clear that results are influenced by the environmental conditions at the site of sampling. Desorption electrospray ionization (DESI), in particular, is affected by variations in relative humidity (RH) levels. Here we describe the design, development, and construction of an environmental control chassis that can actively modulate RH within ± 3% of user-defined set points across a broad humidity range (15%–70% RH). Preliminary characterization demonstrated differential analyte responses across a range of set points, with observed enhancement of leucine-enkephalin, sulfadimethoxine (negative mode), and maltose (positive mode) in response to increased humidity. The measurable differences in analyte signals across discrete humidity set points underscore the importance of environmental control in ambient ionization strategies. The humidity control system outlined here can be translated to other DESI platforms, with construction information provided herein.

DESI↗

Reducing ion diffusion at atmospheric pressure through intermingled positive and negative ions

Increasing ion molecule reaction times for ambient ionization techniques can increase sensitivity of detection. Longer reaction times result in an increase in analyte signal relative to the reactant ion signal, however with a subsequent decrease in the total ion intensity. This loss in the total number of ions reaching the detector limits the extent to which increased reaction time can improve detection in practical applications. In this study ion loss was measured using either electric fields or gas flow to control ion transit time. Ion transit times ranged from 40 ms to 8s, which resulted in ion densities ranging from 5 x 10 6 to 2 x 10 4 ions/cm 3 , respectively. These results provide insights into practical reaction time limitations or experimental boundaries when exploring sensitivity enhancements in ambient ionization. When exploring longer reaction times with an atmospheric flow tube coupled to a mass spectrometer (AFT-MS), an additional corona discharge ionization source of the same polarity was added in an attempt to increase total ion signal, but no improvement in signal was observed. This observation suggested that there was a maximum ion density being reached by the corona discharge that could not be increased by adding more of the same polarity ions. A hypothesis was that intermingling both polarities of ions would reduce ion loss and increase the measured ion signal. When two corona discharge sources—one each of positive and negative polarity—were used simultaneously in an AFT-MS, the total ion signal of either polarity measured by the MS was approximately double the current from a single corona discharge source. An increase in the negative ion signal was also observed when ~10 parts-per-trillion vapor levels of an explosive (RDX) were introduced. In this case both the nitrate reactant ions and the RDX signal more than doubled with the addition of a corona discharge source producing positive ions. When intermingling positive and negative ions, an increase in ion current was also observed when the AFT was coupled directly to a Faraday detector or to an ion mobility spectrometer. This was the first demonstration of interfacing the AFT to an IMS. The observations and developments from this work will help in creating more portable instruments with improved sensitivity for detection of chemicals.

47 OTHER INSTRUMENTATION↗

R “SHINY” GUI DEVELOPMENT FOR URANIUM ISOTOPIC ANALYSIS WITH MATRIX-ASSISTED IONIZATION MASS SPECTROMETRY

The international nuclear safeguards community continues to seek rapid, accurate, and precise characterization capabilities for the in-field measurement of uranium isotopic compositions in nuclear facilities. Mass spectrometry (MS) is considered the “gold standard” for analysis of relatively long-lived actinides such as uranium (U) and plutonium; however, conventional MS analysis often requires time consuming sample preparation and complex analytical methodologies that are difficult to perform in-field or in-facility. Matrix assisted ionization (MAI) is a novel ambient ionization MS technique (i.e., MAI-MS) that potentially addresses these challenges due to the relative simplicity of the ionization phenomenon and ruggedness of ambient MS instrumentation. Savannah River National Laboratory (SRNL, USA) has demonstrated this technique for nanogram-level 235U/238U isotope ratio measurements within seconds, with percent-level analytical uncertainties capable of discriminating depleted, natural, and low-enriched uranium. Current experimental work on developing MAI methods for uranium isotopic analysis has been enabled by parallel development of a comprehensive MAI-MS data analysis suite at SRNL. Development of this bespoke data analysis software was necessary because commercially available ambient MS software is poorly suited for uranium isotope ratio measurement. The effort leverages the power of R, a popular open-source programming language, and Shiny, an R package providing tools for graphical user interface (GUI) and web interface coding. This software allows researchers without any programming experience to harness and utilize R’s considerable data analysis/visualization power.

LaBone, Elizabeth D.↗

Real-Time Screening for Uranium Enrichment by Paper Spray Ionization Mass Spectrometry for Field Applications

A rapid isotope ratio screening technique for uranium enrichment is demonstrated by utilizing paper spray ionization (PSI) high-resolution mass spectrometry (HRMS). Measurements were conducted using an ambient ionization mass spectrometer coupled to a custom-made JEOL PSI attachment apparatus, with de minimus sample preparation requirements. The current method detection limit for individual isotopes (e.g., 235 U and 238 U) is approximately 50 pg, with subsequent optimization expected to further improve U isotopic sensitivity. The PSI analytical method described herein can support rapid analysis (both in-field and in-lab screening) of isotopes-of-interest, as demonstrated by empirical differentiation of depleted uranium (DU) and low enriched uranium (LEU) analytical aliquots. Furthermore, this analytical workflow holds promise for applications in nuclear forensics, international nuclear safeguards, and nonproliferation missions.

Anions↗

Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

The ability to rapidly detect and characterize the chemistry of trace quantities of inorganic species has multiple potential applications, including nuclear safeguards, nuclear forensics, and environmental monitoring. Some mass spectrometric methods currently exist, but they are costly and time-intensive, often destroying chemical information in the process of ionization. Ambient mass spectrometry is a relatively new analytical method in which samples are introduced to the mass spectrometer from atmospheric pressure, rather than from high vacuum. Ambient MS can operate with gentler ionization methods such as electrospray ionization (ESI) and paper-spray ionization (PSI), reducing fragmentation and preserving the chemical information of the analyte. This may be useful for determining the intended purpose of material in a sample. Strontium, part of nuclear fallout, is analyzed here to test these new analytical methods for viability. Electrospray ionization mass spectrometry functions by spraying the sample as a solution through a needle charged to a few kV. A nebulizing gas flows out along with the sample to create the spray before droplets enter a drying chamber with heated drying gas to remove the solvent molecules. From there bare analyte ions enter the mass spectrometer. This method has the advantage of relatively fast sample preparation and stable ionization. More stable ionization produces higher-quality data. Paper-spray ionization mass spectrometry operates by applying sample to a paper triangle. The paper triangle is then electrified in a metal clamp to a few kV before spray solvent is applied. The spray solvent transports analyte in the sample to the tip, where it is ionized and enters the mass spectrometer. One advantage of this method is reduced sample preparation - an analyst can even swipe a surface and cut a triangle directly from the swipe. The data analysis serves to rapidly process tens of samples all at once. The mass spectrometer outputs a file containing a few hundred spectra for each sample. The pipeline processes each one to identify peaks of interest. A full palette of data analysis metrics are generated, including plots of the raw data and plots of calculated values such as isotopic ratios. The pipeline filters the raw data to remove noise and background peaks, as well as peaks representing detector saturation. A heat map is generated to show the overall spectrum in mass-time- intensity space. Post-processing, we obtained the desired calibration curves, demonstrating that both ESI-MS and PSI-MS are viable methods for quantifying trace amounts of inorganics while retaining their chemical speciation information. ESI-MS demonstrated a linear response region of 100 ppb to 20 ppm, with a limit-of-detection of around 100 ppb. At top left is an example spectrum with the {sup 88}SrNO{sub 3} peak identified to show the retention of chemical speciation. PSI-MS showed a linear response region of around 1 ppb to 1 ppm, with a limit-of-detection of near 1 ppb. PSI-MS produced more erratic results than ESI-MS, likely due to the variability in ionization resulting from manual positioning of the paper triangle near the MS inlet. Future efforts will focus on improving the repeatability of PSI-MS as well as analyzing other species of interest such as cerium and uranium. Improvements will also be made to create more reliable data extraction and intelligent data filtering.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rapid 235 U/ 238 U determination by matrix assisted ionization–time-of-flight mass spectrometry

Matrix-assisted ionization (MAI) of inorganic analytes is a nascent research domain that holds promise for rapid, potentially facility-deployable analytical applications. Here, we present results of MAI uranium isotopic analysis ( 235 U/ 238 U) obtained on the timescale of minutes utilizing simple sample preparation and an ambient ionization time-of-flight mass spectrometer (ToF MS). Experimental MAI-ToF MS characterization of uranium Certified Reference Materials (CRMs) was used to establish method calibration and validate quantitative 235 U/ 238 U determination spanning depleted, natural, and low-enriched uranium isotopic compositions. Secondary standard analyses with total uranium mass loadings of 5–500 ng per analysis yield accurate calibrated 235 U/ 238 U results and relative uncertainties of 4.7–17.2% (approx. ±95% confidence level), with weighted-mean uncertainties approaching 1.5%. This method permits accurate determination of uranium isotopic composition in a sample with uranium content as low as 200 pg for equal atom 235 U: 238 U. Instrument detection limits constrain the minimum uranium mass required to identify the presence of highly enriched uranium (HEU ≥20% 235 U) as only 500 pg using the method presented here. MAI-ToF MS quantitation of relatively extreme isotope ratios ( 235 U/ 238 U ≤ 0.01) is limited by detection of minor 235 U (LoD 100 pg 235 U/analysis ≈ 10 ng total U/analysis), and subsequent method optimization is anticipated to further reduce these limits. These findings underscore the potential of MAI-ToF MS for isotopic characterization of uranium and other inorganic species for both basic and applied science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heterogeneous Catalysis by Fullerene C 60 : Photocatalytic Dehydro‐Dimerization of Primary Amines and Tetrahydroquinolines Studied Using Thread Spray Mass Spectrometry

Abstract Removal of a catalyst after a catalytic process is a time‐consuming and challenging process. In this paper, a fullerene catalyst coated on cellulose thread is developed and applied it in a heterogeneous photoreaction screening via a thread spray mass spectrometry (MS) platform. The surface of the cellulose thread is modified with NH 2 groups, which subsequently allows immobilization of fullerene C 60 on the thread. The final fullerene functionalized thread is placed in a glass capillary and the solution of the reactant to be interrogated is added. The assembly of thread and glass capillary is placed in front of a mass spectrometer, which serves as an online photoreaction platform after a light source and direct current high voltage are applied. As an ambient ionization approach, the photocatalytic reaction screening platform enabled real‐time MS characterization of products and intermediates and using only nanomole quantities of reactants. Fullerene C 60 is identified to facilitate dehydro‐dimerization reactions from amines. Norharmane shows a unique photo‐oxygenated dimer formation. The functionalized threads immobilized with fullerene C 60 are reusable, confirming the heterogeneous nature of the platform. Thus, this system provided real‐time screening of reactions catalyzed by fullerene C 60 and a means to investigate the reaction mechanism.

Chemistry↗

Thermal and Catalytic Decomposition of 2-Hydroxyethylhydrazine and 2-Hydroxyethylhydrazinium Nitrate Ionic Liquid

To develop chemical kinetics models for the combustion of ionic liquid-based monopropellants, identification of the elementary steps in the thermal and catalytic decomposition of components such as 2-hydroxyethylhydrazinium nitrate (HEHN) is needed but is currently not well understood. The first decomposition step in protic ionic liquids such as HEHN is typically the proton transfer from the cation to the anion, resulting in the formation of 2-hydroxyethylhydrazine (HEH) and HNO 3 . In the first part of this investigation, the high-temperature thermal decomposition of HEH is probed with flash pyrolysis (<1400 K) and vacuum ultraviolet (10.45 eV) photoionization time-of-flight mass spectrometry (VUV-PI-TOFMS). Next, the investigation into the thermal and catalytic decomposition of HEHN includes two mass spectrometric techniques: (1) tunable VUV-PI-TOFMS (7.4-15 eV) and (2) ambient ionization mass spectrometry utilizing both plasma and laser ionization techniques whereby HEHN is introduced onto a heated inert or iridium catalytic surface and the products are probed. The products can be identified by their masses, their ionization energies, and their collision-induced fragmentation patterns. Further, formation of product species indicates that catalytic surface recombination is an important reaction process in the decomposition mechanism of HEHN. The products and their possible elementary reaction mechanisms are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of Direct Injection/Ionization Mass Spectrometry Methods for Whole Molecule Characterization

The objective of this work is to adapt ambient ionization mass spectrometry (AMS) techniques for the rapid analysis of intact uranium complexes, stable strontium, cerium, and explosive compounds. The methods used were “soft ionization” techniques, which facilitate the detection of whole molecule complexes. The soft ionization mass spectrometry (MS) techniques that were investigated include paper spray ionization (PSI), matrix-assisted ionization (MAI), electrospray ionization (ESI) and direct analysis in real time (DART). For the first time, PSI-MS methods were successfully developed for whole molecule uranium-containing analytes (uranyl acetate, uranyl nitrate, and uranyl-tributylphosphate complexes). This was also the first demonstration of uranium complex detection and characterization and one of the few examples of inorganic analysis using MAI techniques. Proof of concept experiments also putatively identified matrix-derived ions and ion complexes that have not previously been described in the literature. Additionally, PSI-MS on cotton swipe samples doped with a multi-element standard containing μg levels of U, Bi, Pb, Cd, Fe, and Zn were directly analyzed without purification, representing a major improvement over existing methods. Both PSI and MAI methods demonstrated limits of detection (LODs) in the 10 - 100’s ng for various uranyl species within a range of 10’s ppm - 100’s ppb, dependent on analytical method and analyte species. AMS methods were also developed for other inorganics, including Ce and Sr, and organic explosive residues to address specific challenges in environmental monitoring and forensics. Further refinement and qualification of the AMS techniques developed within this effort would lead to significant cost reduction and timeliness by facilitating the triage and queueing of samples for subsequent more sensitive and time-consuming analyses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modelling of equatorial phase and amplitude scintillations from OGO-6 and AE irregularity data

The technique of modelling equatorial phase and amplitude scintillations from in-situ measurements of irregularity amplitude, ambient ionization density and irregularity power spectrum is outlined. The in-situ measurements do not directly provide information on irregularity layer thickness for which radar backscatter observations are utilized. The equatorial scintillation models developed from OGO-6 and AE-C in-situ measurements during the two solstices are presented. Considerable differences in the longitude variation of scintillations are predicted during the two solstices. The model estimates are in good agreement with the available ground based phase and amplitude measurements. Problems associated with the use of bottomside spread-F data for transionospheric propagation modelling at VHF/UHF are also discussed.

Basu, S.↗

G0.18-0.04 - Interaction of thermal and nonthermal radio structures in the arc near the galactic center

Using a high-resolution radio-continuum image made at a frequency of 4.8 GHz, the radio source G0.18-0.04 located at the intersection of the galactic center Arc with the galactic plane is discussed. In this direction, the radio Arc is composed of a set of linear, nonthermal filamentary structures superimposed on a narrow, sickle-shaped, thermal feature which crosses them. The radio image suggests a physical interaction between the thermal and nonthermal structures. It is argued that the magnetic field is dynamically important and that its strength is estimated to be very large (0.001 G). Furthermore, it is suggested that the ionization of G0.18-0.04 is caused by collisional ionization rather than ultraviolet photons from massive stars. The discussion presents possible ways in which some of the energy of the relativistc particles or the magnetic field in the nonthermal filaments might be extracted to ionize ambient gas in the galactic plane.

Yusef-Zadeh, Farhad↗

Large decreases in ionospheric total electron content as a result of thermospheric composition changes during geomagnetic storms

The geomagnetic storms of April 17-21,2002 and May 29-30,2003 caused large decreases in the O/N2 column density ratio in the thermosphere. For these storms, ON2 column density decreases of greater than 50% were observed to extend to mid-to-low latitudes with the FUV sensitive Earth Camera of the Visible Imaging System (VIS) on the Polar spacecraft. Simultaneously in these same regions, the ground-based GPS network observed approximately 80% reductions in the Total Electron Content (TEC) of the ionosphere. The reduction in the Om2 column density ratio is due mainly to increases in the molecular species that have welled-up into the thermosphere from the lower levels of the atmosphere due to auroral heating. The geomagnetic-storm driven increase in molecular densities at typical ionospheric heights rapidly charge exchange with the ambient ionized atoms and subsequently dissociatively recombine with the ionospheric electrons leading to a reduction in the total charge density. The transition boundaries between high and low regions of O/N2 as well as TEC can be tracked in the images and the thermospheric winds can be determined from the motion of the boundaries. The motion of these boundaries during the development of the geomagnetic storm will be discussed.

Sigwarth, J. B.↗

The Dynamics of Thermospheric Composition and Ionospheric Total Electron Content During Geomagnetic Storms

The geomagnetic storms of April 17-21,2002 and May 29-30,2003 caused large decreases in the O/N2 column density ratio in the thermosphere. For these storms, O/N2 column density decreases of greater than 50% were observed to extend to mid-to-low latitudes with the FUV sensitive Earth Camera of the Visible Imaging System (VIS) on the Polar spacecraft. Simultaneously in these same regions, the ground-based GPS network observed approximately 80% reductions in the Total Electron Content (TEC) of the ionosphere. The reduction in the O/N2 column density ratio is due mainly to increases in the molecular species that have welled-up into the thermosphere from the lower levels of the atmosphere due to auroral heating. The geomagnetic-storm driven increase in molecular densities at typical ionospheric heights rapidly charge exchange with the ambient ionized atoms and subsequently dissociatively recombine with the ionospheric electrons leading to a reduction in the total charge density. The transition boundaries between high and low regions of O/N2 as well as TEC can be tracked in the images and the thermospheric winds may be inferred from the motion of the boundaries. The motion of these boundaries during the development of the geomagnetic storm will be discussed.

Sigwarth, John B.↗

Charges on Strange Quark Nuggets in Space

This viewgraph presentation reviews the work done in calculations to find ZN such that the rate of ambient photons ionize the strange quark nuggets (SQNs) Electrons are equal to the rate of ambient e's to replace them.

Teplitz, V.↗

Optical Microscopy-Guided Laser Ablation Electrospray Ionization Ion Mobility Mass Spectrometry: Ambient Single Cell Metabolomics with Increased Confidence in Molecular Identification

Single cell analysis is a field of increasing interest as new tools are continually being developed to understand intercellular differences within large cell populations. Laser-ablation electrospray ionization mass spectrometry (LAESI-MS) is an emerging technique for single cell metabolomics. Over the years, it has been validated that this ionization technique is advantageous for probing the molecular content of individual cells in situ. Here, we report the integration of a microscope into the optical train of the LAESI source to allow for visually informed ambient in situ single cell analysis. Additionally, we have coupled this ‘LAESI microscope’ to a drift-tube ion mobility mass spectrometer to enable separation of isobaric species and allow for the determination of ion collision cross sections in conjunction with accurate mass measurements. This combined information helps provide higher confidence for structural assignment of molecules ablated from single cells. Here, we show that this system enables the analysis of the metabolite content of Allium cepa epidermal cells with high confidence structural identification together with their spatial locations within a tissue.

59 BASIC BIOLOGICAL SCIENCES↗

The effect of saturated thermal conduction on clouds in a hot plasma

We numerically investigate the internal evolution of multiphase clouds, which are at rest with respect to an ambient, highly ionized medium (HIM) representing the hot component of the circumgalactic medium. Time-dependent saturated thermal conduction and its implications like condensation rates and mixing efficiency are assessed in multiphase clouds. Our simulations are carried out by using the adaptive mesh refinement code FLASH. The model clouds are initially in both hydrostatic and thermal equilibrium and are in pressure balance with the HIM. Thus, they have steep gradients in both temperature and density at the interface to HIM leading to non-negligible thermal conduction. Several physical processes are considered numerically or semi-analytically: thermal conduction, radiative cooling and external heating of gas, self-gravity, mass diffusion, and dissociation of molecules and ionization of atoms. It turns out that saturated thermal conduction triggers a continuous condensation irrespective of cloud mass. Dynamical interactions with ambient HIM all relate to the radial density gradient in the clouds: (1) mass flux due to condensation is the higher the more homogeneous the clouds are; (2) mixing of condensed gas with cloud gas is easier in low-mass clouds, because of their shallower radial density gradient; and thus (3) accreted gas is distributed more efficiently. A distinct and sub-structured transition zone forms at the interface between cloud and HIM, which starts at smaller radii and is much narrower as deduced from analytical theory.

79 ASTRONOMY AND ASTROPHYSICS↗