Ion–surface collisions in mass spectrometry: Where analytical chemistry meets surface science
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
The Analytical Chemistry and Material Development Group maintains a capability in chemical analysis, materials R&D failure analysis and contamination control. The uniquely qualified staff and facility support the needs of flight projects, science instrument development and various technical tasks, as well as Cal Tech.
Actinide Analytical Chemistry (C-AAC) at LANL has a full set of analytical chemistry capabilities to support the production mission. AAC uses the Pu Metal Standards Exchange Program to validate and verify that the data quality objectives are met for Pu Sustainment. This presentation describes: analytical chemistry techniques used to address requirements, analytical sample flow, and process overview.
Presented here are three case studies that demonstrate the breadth of bulk actinide analytical chemistry at Los Alamos National Laboratory (LANL). This laboratory was established during the Manhattan Project and is still considered one of the premier analytical laboratories for special nuclear materials characterization around the globe. First, the analytical chemistry of 238 Pu is presented, showcasing the unique challenges of this high activity isotope. Next, the analysis of 241 AmO 2 is discussed from the perspective of supporting nascent production at LANL. Finally, the analytical chemistry support of the production of plutonium non-destructive assay standards is discussed. Furthermore these examples paint a picture of the analytical capabilities needed to meet the dynamic challenges of LANL’s nuclear programs.
NASA has been developing and testing two different types of oxygen separation systems. One type of oxygen separation system uses pressure swing technology, the other type uses a solid electrolyte electrochemical oxygen separation cell. Both development systems have been subjected to long term testing, and performance testing under a variety of environmental and operational conditions. Testing these two systems revealed that measuring the product purity of oxygen, and determining if an oxygen separation device meets Aviator's Breathing Oxygen (ABO) specifications is a subtle and sometimes difficult analytical chemistry job. Verifying product purity of cryogenically produced oxygen presents a different set of analytical chemistry challenges. This presentation will describe some of the sample acquisition and analytical chemistry challenges presented by verifying oxygen produced by an oxygen separator - and verifying oxygen produced by cryogenic separation processes. The primary contaminant that causes gas samples to fail to meet ABO requirements is water. The maximum amount of water vapor allowed is 7 ppmv. The principal challenge of verifying oxygen produced by an oxygen separator is that it is produced relatively slowly, and at comparatively low temperatures. A short term failure that occurs for just a few minutes in the course of a 1 week run could cause an entire tank to be rejected. Continuous monitoring of oxygen purity and water vapor could identify problems as soon as they occur. Long term oxygen separator tests were instrumented with an oxygen analyzer and with an hygrometer: a GE Moisture Monitor Series 35. This hygrometer uses an aluminum oxide sensor. The user's manual does not report this, but long term exposure to pure oxygen causes the aluminum oxide sensor head to bias dry. Oxygen product that exceeded the 7 ppm specification was improperly accepted, because the sensor had biased. The bias is permanent - exposure to air does not cause the sensor to return to its original response - but the bias can be accounted for by recalibrating the sensor. After this issue was found, continuous measurements of water vapor in the oxygen product were made using an FTIR. The FTIR cell is relatively large, so response time is slow - but moisture measurements were repeatable and accurate. Verifying ABO compliance for oxygen produced by commercial cryogenic processes has a different set of sample acquisition and analytical chemistry challenges. Customers want analytical chemists to conserve as much as possible. Hygrometers are not exposed to hours of continuous flow of oxygen, so they don't bias, but small amounts of contamination in valves can cause a "fail". K bottles are periodically cleaned and recertified - after cleaning residual moisture can cause a "fail". Operators let bottle pressure drop to room pressure, introduce outside air into the bottle, and the subsequent fill will "fail". Outside storage of K‐bottles has allowed enough in‐leakage, so contents will "fail".
The recently released Supplemental Directive, NA-1 SD 1027, updates the radionuclide threshold values in DOE-STD-1027-92 CN1 to reflect the use of modern parameters for dose conversion factors and breathing rates. The directive also corrects several arithmetic errors within the original standard. The result is a roughly four-fold increase in the amount of weapons-grade nuclear material allowed within a designated radiological facility. Radiological laboratory space within the recently constructed Radiological Laboratory Office and Utility Building (RLUOB) is slated to house selected analytical chemistry support activities in addition to small-scale actinide R&D activities. RLUOB is within the same facility operations envelope as TA-55. Consolidation of analytical chemistry activities to RLUOB and PF-4 offers operational efficiency improvements relative to the current pre-CMRR plans of dividing these activities between RLUOB, PF-4, and CMR. RLUOB is considered a Radiological Facility under STD-1027 - 'Facilities that do not meet or exceed Category 3 threshold criteria but still possess some amount of radioactive material may be considered Radiological Facilities.' The supplemental directive essentially increases the allowable material-at-risk (MAR) within radiological facilities from 8.4 g to 38.6 g for 239 Pu. This increase in allowable MAR provides a unique opportunity to establish additional analytical chemistry support functions in RLUOB without negatively impacting either R&D activities or facility operations. Individual radiological facilities are tasked to determine MAR limits (up to the Category 3 thresholds) appropriate to their operational conditions. This study presents parameters that impact establishing MAR limits for RLUOB and an assessment of how various analytical chemistry support functions could operate within the established MAR limits.
This report discusses LANL's actinide analytical chemistry capabilities.
Two-dimensional (2D) metal halide perovskites are promising next generation semiconducting materials at the forefront of research in solar cells, LEDs, and other devices. Here, we report on an undergraduate intermediate analytical chemistry laboratory experience where students were taught fundamental chemistry concepts, including solubility, complexation, spectroscopy, and microscopy, through the introduction and study of 2D halide perovskite materials. Students explore multiple facets of perovskite synthesis, structure, and properties through a modular set of experiments that students used to form a holistic picture of this material. Importantly, this inquiry-based lab supports students through a guided research process, and students report high interest and learning gains from an end of the semester survey. We further discuss ways to adapt this lab to course, student, equipment, and budget needs. Overall, this laboratory experience teaches and applies the fundamental concepts and tools of analytical chemistry to the contemporary materials research field.
The concept of 'core capability' can be nebulous one. Even at a fairly specific level, where core capability equals maintaining essential services, it is highly dependent upon the perspective of the requestor. Samples are submitted to analytical services because the requesters do not have the capability to conduct adequate analyses themselves. Some requests are for general chemical information in support of R and D, process control, or process improvement. Many analyses, however, are part of a product certification package and must comply with higher-level customer quality assurance requirements. So which services are essential to that customer - just those for product certification? Does the customer also (indirectly) need services that support process control and improvement? And what is the timeframe? Capability is often expressed in terms of the currently utilized procedures, and most programmatic customers can only plan a few years out, at best. But should core capability consider the long term where new technologies, aging facilities, and personnel replacements must be considered? These questions, and a multitude of others, explain why attempts to gain long-term consensus on the definition of core capability have consistently failed. This preliminary report will not try to define core capability for any specific program or set of programs. Instead, it will try to address the underlying concerns that drive the desire to determine core capability. Essentially, programmatic customers want to be able to call upon analytical chemistry services to provide all the assays they need, and they don't want to pay for analytical chemistry services they don't currently use (or use infrequently). This report will focus on explaining how the current analytical capabilities and methods evolved to serve a variety of needs with a focus on why some analytes have multiple analytical techniques, and what determines the infrastructure for these analyses. This information will be useful in defining a roadmap for what future capability needs to look like.
The Y-12 Analytical Chemistry Organization (ACO) Off-Site Union Valley Facility (Union Valley Facility) is managed by Babcock and Wilcox Technical Services Y-12, L.L.C. (B and W Y-12) through the Y-12 National Security Complex organization. Accordingly, the Y-12 Pollution Prevention Program encompasses the operations conducted at the Union Valley Facility. The Y-12 Program is designed to fully comply with state, federal and U.S. Department of Energy (DOE) requirements concerning waste minimization/pollution prevention as documented in the Y-12 Pollution Prevention Program Plan. The Program is formulated to reduce the generation and toxicity of all Y-12 wastes in all media, including those wastes generated by the Union Valley Facility operations. All regulatory and DOE requirements are met by the Y-12 Program Plan.
Implementation of computer programs based on multivariate statistical algorithms makes possible obtaining reliable information from long data vectors that contain large amounts of extraneous information, for example, noise and/or analytes that we do not wish to control. Three examples are described. Each of these applications requires the use of techniques characteristic of modern analytical chemistry. The first example, using a quantitative or analytical model, describes the determination of the acid dissociation constant for 2,2'-pyridyl thiophene using archived data. The second example describes an investigation to determine the active biocidal species of iodine in aqueous solutions. The third example is taken from a research program directed toward advanced fiber-optic chemical sensors. The second and third examples require heuristic or empirical models.
The impact that laser techniques might have in chemical analysis is examined. Absorption, scattering, and heterodyne detection is considered. Particular emphasis is placed on the advantages of using frequency-tunable sources, and dye solution lasers are regarded as the outstanding example of this type of laser. Types of spectroscopy that can be carried out with lasers are discussed along with the ultimate sensitivity or minimum detectable concentration of molecules that can be achieved with each method. Analytical applications include laser microprobe analysis, remote sensing and instrumental methods such as laser-Raman spectroscopy, atomic absorption/fluorescence spectrometry, fluorescence assay techniques, optoacoustic spectroscopy, and polarization measurements. The application of lasers to spectroscopic methods of analysis would seem to be a rewarding field both for research in analytical chemistry and for investments in instrument manufacturing.
This project seeks to reestablish our analytical capability to characterize Am bulk material and develop a reference material suitable to characterizing the purity and assay of 241 Am oxide for industrial use. The tasks associated with this phase of the project included conducting initial separations experiments, developing thermal ionization mass spectrometry capability using the 243 Am isotope as an isotope dilution spike , optimizing the spike for the determination of 241 Pu- 241 Am radiochemistry, and, additionally, developing and testing a methodology which can detect trace to ultra- trace levels of Pu (both assay and isotopics) in bulk Am samples .
Over the last several decades, science has benefited tremendously by the implementation of digital electronic components for analytical instrumentation. A pioneer in this area of scientific inquiry was Howard Malmstadt. Frequently, such revolutions in scientific history can be viewed as a series of discoveries without a great deal of attention as to how mentorship shapes the careers and methodologies of those who made great strides forward for science. Here, this article focuses on the verifiable relationships of those who are connected through the academic tree of Malmstadt and how their experiences and the context of world events influenced their scientific pursuits. Particular attention is dedicated to the development of American chemistry departments and the critical role played by many of the individuals in the tree in this process.
No abstract provided
The development of new analytical methods most often focus on novel materials used to impart selectivity or sensitivity to the protocol. Ionic liquids (ILs) are a class of solvents that have been extensively explored as promising materials for various applications and continue to be explored due to their tunable physicochemical properties. These materials possess melting temperatures below 100 °C and can interact with analytes through a multitude of interactions afforded by their readily tunable chemical structure. These interactions include electrostatic, dispersive, hydrogen bonding, π–π, and dipolar interactions and can be modulated or strengthened based on the functional groups present within the chemical structure. ILs consist predominately of organic cations and either inorganic or organic anions, both of which can be functionalized with desired moieties. Common cation and anions found in IL chemical structures are presented in Figure 1. The unique polarity afforded by the ionic structure has also led to their increasing use in areas including sample preparation, chemical separations, electrochemistry, mass spectrometry, and spectroscopy.
Quantitation of inter-related actinides in nuclear materials, whether they be intercepted (e.g. stolen fuel pellets) or purposefully collected (e.g. cotton swipe samples), is essential in modern nuclear forensics and safeguards. Well-designed procedures may provide insight into a material’s “age” (i.e. time since last purification), suggest processing/preparation routes, and point to involved parties. In the present work, we detail the design and preliminary application of a thermal ionization mass spectrometry (TIMS) based approach to the analysis of thorium-230 within uranium-bearing materials. These efforts are in-line with a chronometric-type analysis strategy and focused on identification of appropriate preparation procedures, development of required spiking materials (i.e. 229 Th), and evaluation of uranium certified reference materials (CRMs). The presence of thorium in these materials is expected to be largely due to a combination of the decay of parent uranium (e.g. 234 U) to daughter nuclides (e.g. 230 Th), and thorium persistence following last purification.
Solid debris was recovered from the previously-emptied nitrate salt waste drum S855793. The bulk sample was nondestructively assayed for radionuclides in its as-received condition. Three monoliths were selected for further characterization. Two of the monoliths, designated Specimen 1 and 3, consisted primarily of sodium nitrate and lead nitrate, with smaller amounts of lead nitrate oxalate and lead oxide by powder x-ray diffraction. The third monolith, Specimen 2, had a complex composition; lead carbonate was identified as the predominant component, and smaller amounts of nitrate, nitrite and carbonate salts of lead, magnesium and sodium were also identified. Microfocused x-ray fluorescence (MXRF) mapping showed that lead was ubiquitous throughout the cross-sections of Specimens 1 and 2, while heteroelements such as potassium, calcium, chromium, iron, and nickel were found in localized deposits. MXRF examination and destructive analysis of fragments of Specimen 3 showed elevated concentrations of iron, which were broadly distributed through the sample. With the exception of its high iron content and low carbon content, the chemical composition of Specimen 3 was within the ranges of values previously observed in four other nitrate salt samples recovered from emptied waste drums.