Search NASA⌕ Search

SEARCH · Search NASA

Results for “analytical detection method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The properties of and analytical methods for detection of LiOH and Li2CO3

Lithium hydroxide (LiOH) is used as a CO2 absorbent in the Shuttle Extravehicular Mobility Unit (EMU) Portable Life Support System (PLSS). The first objective was to survey parameters that may be used to indicate conversion of LiOH to Li2CO3, and compile a list of all possible properties, including physical, chemical, structural, and electrical, that may serve to indicate the occurrence of reaction. These properties were compiled for the reactant (LiOH), the intermediate monohydrate compound (LiOH.H2O), and the final product (Li2CO3). The second objective was to survey measurement and analytical techniques which may be used in conjunction with each of the properties identified above, to determine the extent of conversion of LiOH to Li2CO3. Both real-time and post-run techniques were of interest. The techniques were also evaluated in terms of complexity, technology readiness, materials/equipment availability, and cost, where possible.

Selvaduray, Guna↗

Magma-Sediment Interaction Induced Alteration Mineralogy on Mars: Detectability and Analytical Method Comparison Using the Curtis Sandstone as A Terrestrial Analog

Basaltic magmatism is a ubiquitous feature of the Martian crust, and would have interacted with sediments and fluids through the geologic history of Mars to potentially produce higher temperature hydrothermal systems , and contact metamorphic rocks. On Earth, comparable hydrothermal systems represent habitable environments, which can be used as an analog for Mars. Nevertheless, evidence of aforementioned hydrothermal systems on Mars has remained elusive, despite the efforts of both orbital and in-situ analyses. Limited low grade metamorphic minerals typically indicative of hydrothermal systems (prehnite, zeolites, serpentine) have been detected in the Martian crust, though the detections are typically isolated occurrences, and do not necessarily indicate an in-place metamorphic sequence. It is possible that orbital spectroscopy alone is not capable of detecting such an alteration front, with higher resolution in-situ analyses being required to detect the changes in mineralogy and species of alteration minerals associated with magma-sediment interaction. To constrain this, we have investigated a terrestrial analog on the Colorado Plateau, USA, where a mafic dike intrudes a quartz areinite of the Jurassic Curtis Sandstone. The investigation was carried out using Mars relevant instruments: Visible to Near-Infrared (VNIR) spectroscopy analogous to orbital spectroscopy, and X-ray Diffraction (XRD) analogous to CheMin on Mars Sample Laboratory Curiosity. While quartz sandstones have not been, and are unlikely to be, detected on Mars, the relatively mineralogically uniform Curtis Sandstone serves as analog here as it avoids complications of multiple mineral systems or significant element exchange with the surrounding area.

J R Crandall↗

Dextroamphetamine: a pharmacologic countermeasure for space motion sickness and orthostatic dysfunction

Dextroamphetamine has potential as a pharmacologic agent for the alleviation of two common health effects associated with microgravity. As an adjuvant to Space Motion Sickness (SMS) medication, dextroamphetamine can enhance treatment efficacy by reducing undesirable Central Nervous System (CNS) side effects of SMS medications. Secondly, dextroamphetamine may be useful for the prevention of symptoms of post-mission orthostatic intolerance caused by cardiovascular deconditioning during spaceflight. There is interest in developing an intranasal delivery form of dextroamphetanmine for use as a countermeasure in microgravity conditions. Development of this dosage form will require an analytical detection method with sensitivity in the low ng range (1 to 100 ng/mL). During the 1995 Summer Faculty Fellowship Program, two analytical methods were developed and evaluated for their suitability as quantitative procedures for dextroamphetamine in studies of product stability, bioavailability assessment, and pharmacokinetic evaluation. In developing some of the analytical methods, beta-phenylethylamine, a primary amine structurally similar to dextroamphetamine, was used. The first analytical procedure to be evaluated involved hexane extraction and subsequent fluorescamine labeling of beta-phenylethylamine. The second analytical procedure to be evaluated involved quantitation of dextroamphetamine by an Enzyme-Linked ImmunoSorbent Assay (ELISA).

Snow, L. Dale↗

Regulatory and Technical Issues Concerning the Detection and Treatment of NDMA-Contaminated Groundwater at NASA WSTF

The National Aeronautics and Space Administration (NASA) White Sands Test Facility (WSTF) was established in 1963 primarily to provide rocket engine testing services for several NASA programs. The groundwater underlying the site has been contaminated as a result of historical operations. Groundwater contaminants include several volatile organic compounds (VOCs) and two semi-volatile compounds: N-nitrosodimethylamine (NDMA) and N-nitrodimethylamine (DMN). This paper discusses some of the technical, analytical, regulatory, and health risk issues associated with the contaminant plume. The plume has moved approximately 2.5 miles downgradient of the facility industrial boundary, with evidence of continued migration. As a result, NASA has proposed a pump and treat system using air strippers and ultraviolet (UV) oxidation to stabilize future movement of the contaminant plume. The system has been designed to treat 1,076 gallons (4,073 liters) per minute, with provisions for future expansion. The UV oxidation process was selected to treat NDMA-contaminated groundwater based on successes at other NDMA-contaminated sites. Bench- and pilot-scale testing of WSTF groundwater confirmed the ability of UV oxidation to destroy NDMA and generated sufficient data to design the proposed full-scale treatment system. NDMA is acutely toxic and is a probable human carcinogen. EPA-recommended health risk criteria for the residential consumption of NDMA/DMN-contaminated groundwater was used to determine that a 1.0 x 10(exp -6) excess cancer risk corresponds to 1.7 parts per trillion (ppt). EPA analytical methods are unable to detect NDMA and DMN in the low ppt range. EPA's current Appendix IX analytical method used to screen for NDMA, Method 8270, can detect NDMA only at levels that are orders of magnitude greater than the recommended health risk level. Additionally, EPA Method 607, the most sensitive EPA approved method, has a detection limit of 150 ppt. This corresponds to an excess cancer risk of 9.0 x 10(exp -5), which exceeds the State of New Mexico's water quality standard of a cancer risk less than 1 x 10(exp -5). The treatment system has been engineered to treat contaminated groundwater to levels significantly below the New Mexico standard. However, the inability of EPA-approved analytical methods to detect NDMA and DMN at low ppt levels, and to provide verification of compliance with the 1 x 10(exp -5) cancer risk, introduces a notable risk to the long-term operation of the system. WSTF has been working with Southwest Research Institute to develop a non-EPA analytical method that can achieve a reporting limit of 1 ppt, which corresponds to an excess cancer risk of 7.6 x 10(exp -7). WSTF is currently developing a proposal to obtain approval from the New Mexico Environment Department (NMED) of this non-EPA method.

Wiebe, D. T.↗

Enhanced Detection of Vibrio Cholerae in Oyster Homogenate Based on Centrifugal Removal of Inhibitory Agents

The disease cholera, caused by Vibrio cholerae, has been associated with consumption of contaminated seafood, including raw oysters. Detection of V. cholerae in foods typically involves blending the oysters, diluting the homogenate in alkaline peptone water (APW), overnight enrichment, and isolation on selective agar. Unfortunately, the oyster homogenate must be diluted to large volumes because lower dilutions inhibit the growth of V. cholerae. The goals of this study were to develop an alternative to large dilutions and to evaluate the basis for the inhibition observed in lower dilutions of oyster homogenates. Centrifugation of oyster homogenates at 10,000 x g for 15 min, followed by enrichment of the resulting pellet in APW, was found to eliminate the inhibition of V. cholerae growth. Inhibition appears not to be due to competing microflora but to a component(s) released when V. cholerae grows in the presence of oyster homogenate. The inhibitory component(s) kills the V. cholerae after the cell concentration reaches > 10(exp 8) cells/mL, rather than initially preventing their growth. The pH also declines from 8.0 to 5.5 during this period; however, the pH decline by itself appears not to cause V. cholerae death. Seven strains of V. cholerae (01 and non-01) and two strains of V. vulnificus were susceptible to the inhibitory agent(s). However, other Vibrio and non-Vibrio species tested were not inhibited by the oyster homogenates. Based on digestion of oyster homogenates with pronase, trypsin and lipase, the inhibitory reaction involves a protein(s). In a preliminary trial with oyster homogenate seeded with 1 cfu/g of V. cholerae, the modified centrifugation technique detected a slightly higher percentage of samples at a 1:10 dilution than the standard FDA Bacteriological Analytical Method (BAM) detected in uncentrifuged oyster homogenate at a 1:100 dilution. V. cholerae in seeded samples could also be detected more frequently by the modified centrifugation method than by PCR at a 1:10 dilution.

Alexander, Donita↗

Analytical notes - Electrochemical method for early detection and monitoring of coliforms

An electrochemical method for detecting bacteria, based on a linear relationship between inoculum size and the time of hydrogen evolution, was tested for the early detection and monitoring of coliforms in naturally contaminated estuarine and fresh water samples. Standard methods for coliform analysis were performed on each sample, and membrane filtration counts were used to construct dose-response curves; relationships and results are discussed herein.

Wilkins, J. R.↗

Monitoring occupational exposure to cancer chemotherapy drugs

Reports of the health effects of handling cytotoxic drugs and compliance with guidelines for handling these agents are briefly reviewed, and studies using analytical and biological methods of detecting exposure are evaluated. There is little conclusive evidence of detrimental health effects from occupational exposure to cytotoxic drugs. Work practices have improved since the issuance of guidelines for handling these drugs, but compliance with the recommended practices is still inadequate. Of 64 reports published since 1979 on studies of workers' exposure to these drugs, 53 involved studies of changes in cellular or molecular endpoints (biological markers) and 12 described chemical analyses of drugs or their metabolites in urine (2 involved both, and 2 reported the same study). The primary biological markers used were urine mutagenicity, sister chromatid exchange, and chromosomal aberrations; other studies involved formation of micronuclei and measurements of urinary thioethers. The studies had small sample sizes, and the methods were qualitative, nonspecific, subject to many confounders, and possibly not sensitive enough to detect most occupational exposures. Since none of the currently available biological and analytical methods is sufficiently reliable or reproducible for routine monitoring of exposure in the workplace, further studies using these methods are not recommended; efforts should focus instead on wide-spread implementation of improved practices for handling cytotoxic drugs.

Review, Academic↗

Methods of use for sensor based fluid detection devices

Methods of use and devices for detecting analyte in fluid. A system for detecting an analyte in a fluid is described comprising a substrate having a sensor comprising a first organic material and a second organic material where the sensor has a response to permeation by an analyte. A detector is operatively associated with the sensor. Further, a fluid delivery appliance is operatively associated with the sensor. The sensor device has information storage and processing equipment, which is operably connected with the device. This device compares a response from the detector with a stored ideal response to detect the presence of analyte. An integrated system for detecting an analyte in a fluid is also described where the sensing device, detector, information storage and processing device, and fluid delivery device are incorporated in a substrate. Methods for use for the above system are also described where the first organic material and a second organic material are sensed and the analyte is detected with a detector operatively associated with the sensor. The method provides for a device, which delivers fluid to the sensor and measures the response of the sensor with the detector. Further, the response is compared to a stored ideal response for the analyte to determine the presence of the analyte. In different embodiments, the fluid measured may be a gaseous fluid, a liquid, or a fluid extracted from a solid. Methods of fluid delivery for each embodiment are accordingly provided.

Lewis, Nathan S.↗

Application of Ni-63 photo and corona discharge ionization for the analysis of chemical warfare agents and toxic wastes

Over the past decade, advances in instrumental design and refinements in the understanding of ion molecule reactions at atmospheric pressure enabled the application of Ion Mobility Spectrometry (IMS) as a simple inexpensive and sensitive analytical method for the detection of organic trace compounds. Positive and negative gas-phase ions for ion mobility spectrometry have been produced by a variety of methods, including photo-ionization, laser multi photon ionization, surface ionization, corona discharge ionization. The most common ion source used in ion mobility spectrometry is a radioactive Ni-63 foil which is favored due to simplicity, stability, convenience, and high selectivity. If reactant ions like (H2O(n)H)(+) or (H2O(n)O2)(-) dominate in the reaction region, nearly all kinds of compounds with a given proton or electron affinity; are ionized. However, the radioactivity of the Ni-63 foil is one disadvantage of this ion source that stimulates the development and application of other ionization techniques. In this paper, we report analyses of old chemical warfare agents and toxic wastes using Bruker RAID ion mobility spectrometers. Due to the modular construction of the measuring cell, the spectrometers can be equipped with different ion sources. The combined use of Ni-63, photo- and corona discharge ionization allows the identification of different classes of chemical compounds and yields in most cases comparable results.

Stach, J.↗

SSME Propellant Path Leak Detection

The primary objective of this phase of the investigation is the experimental validation of techniques for detecting and analyzing propellant path external leaks which have a high probability of occurring on the SSME. The selection of candidate detection methods requires a good analytic model for leak plumes which would develop from external leaks and an understanding of radiation transfer through the leak plume. One advanced propellant path leak detection technique is obtained by using state-of-art technology of infrared (IR) thermal imaging systems combined with computer, digital image processing and expert systems for the engine protection. The feasibility of the IR leak plume detection will be evaluated on subscale simulated laboratory plumes to determine sensitivity, signal to noise, and general suitability for the application. The theoretical analysis was undertaken with the objective of developing and testing simple, easy-to-use models to predict the amount of radiation coming from a radiation source, background plate (BP), which can be absorbed, emitted and scattered by the gas leaks.

Roger Crawford↗

SSME Propellant Path Leak Detection

The complicated high-pressure cycle of the space shuttle main engine (SSME) propellant path provides many opportunities for external propellant path leaks while the engine is running. This mode of engine failure may be detected and analyzed with sufficient speed to save critical engine test hardware from destruction. The leaks indicate hardware failures which will damage or destroy an engine if undetected; therefore, detection of both cryogenic and hot gas leaks is the objective of this investigation. The primary objective of this phase of the investigation is the experimental validation of techniques for detecting and analyzing propellant path external leaks which have a high probability of occurring on the SSME. The selection of candidate detection methods requires a good analytic model for leak plumes which would develop from external leaks and an understanding of radiation transfer through the leak plume. One advanced propellant path leak detection technique is obtained by using state-of-the-art technology infrared (IR) thermal imaging systems combined with computer, digital image processing, and expert systems for the engine protection. The feasibility of IR leak plume detection is evaluated on subscale simulated laboratory plumes to determine sensitivity, signal to noise, and general suitability for the application.

Roger Crawford↗

The development of a volatile organics concentrator for use in monitoring Space Station water quality

A breadboard concept of a volatile organics concentrator (VOC) is manufactured and tested for optimized water-quality analysis in a space environment. The VOC system is attached to a gas chromatograph/mass spectrometer to analyze the volatile chemicals relevant to the operation of Space Station Freedom. The preliminary tests include: (1) comparisons with analyses based on direct on-column injections of standards; (2) analyses of iodinated volatile organics; (3) comparisons of nitrogen vs helium as the chromatography carrier gas; and (4) measurements of collection efficiency. The VOC can analyze EPA method-624 analytes at comparable detection using flame-ionization detection and can analyze volatile iodinated compounds. The breadboard has good reproducibility and can use nitrogen as a carrier gas; good results are noted for the collection and concentration levels and for water removal.

Bodek, Itamar↗

A comparative review of optical surface contamination assessment techniques

This paper will review the relative sensitivities and practicalities of the common surface analytical methods that are used to detect and identify unwelcome adsorbants on optical surfaces. The compared methods include visual inspection, simple reflectometry and transmissiometry, ellipsometry, infrared absorption and attenuated total reflectance spectroscopy (ATR), Auger electron spectroscopy (AES), scanning electron microscopy (SEM), secondary ion mass spectrometry (SIMS), and mass accretion determined by quartz crystal microbalance (QCM). The discussion is biased toward those methods that apply optical thin film analytical techniques to spacecraft optical contamination problems. Examples are cited from both ground based and in-orbit experiments.

Heaney, James B.↗

Chemical Detection and Identification Techniques for Exobiology Flight Experiments

Exobiology flight experiments require highly sensitive instrumentation for in situ analysis of the volatile chemical species that occur in the atmospheres and surfaces of various bodies within the solar system. The complex mixtures encountered place a heavy burden on the analytical Instrumentation to detect and identify all species present. The minimal resources available onboard for such missions mandate that the instruments provide maximum analytical capabilities with minimal requirements of volume, weight and consumables. Advances in technology may be achieved by increasing the amount of information acquired by a given technique with greater analytical capabilities and miniaturization of proven terrestrial technology. We describe here methods to develop analytical instruments for the detection and identification of a wide range of chemical species using Gas Chromatography. These efforts to expand the analytical capabilities of GC technology are focused on the development of detectors for the GC which provide sample identification independent of the GC retention time data. A novel new approach employs Penning Ionization Electron Spectroscopy (PIES).

Kojiro, Daniel R.↗

Integration of SAR and DEM data: Geometrical considerations

General principles for integrating data from different sources are derived from the experience of registration of SAR images with digital elevation models (DEM) data. The integration consists of establishing geometrical relations between the data sets that allow us to accumulate information from both data sets for any given object point (e.g., elevation, slope, backscatter of ground cover, etc.). Since the geometries of the two data are completely different they cannot be compared on a pixel by pixel basis. The presented approach detects instances of higher level features in both data sets independently and performs the matching at the high level. Besides the efficiency of this general strategy it further allows the integration of additional knowledge sources: world knowledge and sensor characteristics are also useful sources of information. The SAR features layover and shadow can be detected easily in SAR images. An analytical method to find such regions also in a DEM needs in addition the parameters of the flight path of the SAR sensor and the range projection model. The generation of the SAR layover and shadow maps is summarized and new extensions to this method are proposed.

Kropatsch, Walter G.↗