Search NASA⌕ Search

SEARCH · Search NASA

Results for “analytical microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Subgroup Characteristics of Marine Methane-Oxidizing ANME-2 Archaea and Their Syntrophic Partners as Revealed by Integrated Multimodal Analytical Microscopy

Phylogenetically diverse environmental ANME archaea and sulfate-reducing bacteria cooperatively catalyze the anaerobic oxidation of methane oxidation (AOM) in multicelled consortia within methane seep environments. To better understand these cells and their symbiotic associations, we applied a suite of electron microscopy approaches, including correlative fluorescence in situ hybridization-electron microscopy (FISH-EM), transmission electron microscopy (TEM), and serial block face scanning electron microscopy (SBEM) three-dimensional (3D) reconstructions. FISH-EM of methane seep-derived consortia revealed phylogenetic variability in terms of cell morphology, ultrastructure, and storage granules. Representatives of the ANME-2b clade, but not other ANME-2 groups, contained polyphosphate-like granules, while some bacteria associated with ANME-2a/2c contained two distinct phases of iron mineral chains resembling magnetosomes. 3D segmentation of two ANME-2 consortium types revealed cellular volumes of ANME and their symbiotic partners that were larger than previous estimates based on light microscopy. Polyphosphate-like granule-containing ANME (tentatively termed ANME-2b) were larger than both ANME with no granules and partner bacteria. This cell type was observed with up to 4 granules per cell, and the volume of the cell was larger in proportion to the number of granules inside it, but the percentage of the cell occupied by these granules did not vary with granule number. Here, these results illuminate distinctions between ANME-2 archaeal lineages and partnering bacterial populations that are apparently unified in their ability to perform anaerobic methane oxidation.

59 BASIC BIOLOGICAL SCIENCES↗

Recent Advances in Analytical Electron Microscopy for Irradiated Materials

Analytical electron microscopy (AEM) in the scanning transmission electron microscope (STEM) has long been a staple of post-irradiation examination (PIE) and materials development campaigns. Recently, new advances in both STEM hardware and post-processing data-analysis software, along with ancillary advances such as in focused ion beam (FIB) sample preparation, has led to exciting advances in the quantity and quality of data that can be obtained. This talk will summarize recent experiments performed at Oak Ridge National Laboratory (ORNL), especially work on neutron-irradiated materials and fuels taking advantage of a newly-installed latest-generation AEM tool in the ORNL irradiated materials laboratories. ORNL installed a new FEI Talos F200X microscope, a 200 keV, high-brightness Schottky emission AEM system optimized for high-speed, high-efficiency X-ray mapping experiments. The F200X features the FEI 'SuperX' four-sector silicon drift detector (SDD) X-ray detector, which provides 0.9 sr solid angle of collection. By combining the high-brightness electron source, latest-generation electron optics, and fast computers and pulse processors, X-ray mapping speed is increased by a factor of 50-100 x compared to the previous-generation instruments. In addition to improvements in hardware, data mining via multivariate statistical analysis (MVSA) allows for maximum insight to the data obtained from the new hardware. MVSA data mining of the X-ray maps allows, for instance, unbiased computational identification of the phases present, and discovery of small phases or precipitates not expected by the human analyst. This talk will present examples of experiments performed using the most modern AEM tools and software. Silicon carbide is a major candidate for next-generation nuclear applications. Nano-infiltration by transient eutectic (NITE) SiC requires low sintering temperatures. X-ray mapping of the NITE structure find pockets of different oxides, such as Zr-Y-oxide, Y-Al-oxide, and yttria. MVSA data mining finds the regions where different oxides are present and indicates that Y additions preferentially wet grain boundaries, where Zr additions are preferentially concentrated at grain triple points. SiC coatings from AGR-I experiment TRISO particles were found to contain significant quantities of fission products (e.g., Pd) as well as actinides (U, Pu). MVSA data mining found complex precipitates and grain boundary films of the fission products and actinides deep (∼several microns) into the SiC layer. Advanced AEM methods, combined with MVSA data mining, makes possible both rapid and detailed PIE. Ferritic alloys, such as accident-tolerant FeCrAl grades, benefit greatly from advanced AEM examination. Neutron-irradiated FeCrAl precipitates the detrimental Cr-rich α' phase. Because the SuperX SDD system has four detectors, it is possible to obtain high X-ray count rates even on a highly tilted specimen, as might be needed to obtain STEM images of dislocation loops. Results on neutron-irradiated FeCrAl indicates that α' size and number density can be obtained by AEM, and MVSA results determine that minor elements (such as Si) has complex radiation-induced segregation behavior at grain boundaries. We have also developed and validated computer models of the AEM experiment, allowing different microstructures' X-ray map results to be simulated for different STEM instruments. This allows X-ray mapping to be more quantitative, such as by estimating what size nanoclusters in an oxide-dispersion strengthened steel would be visible or invisible in STEM. In summary, new advanced AEM technology provides a major leap forward in experiments possible in PIE of irradiated materials. (authors)

36 MATERIALS SCIENCE↗

Cation ratio fluctuations in Cu 2 ZnSnS 4 at the 20 nm length scale investigated by analytical electron microscopy

Kesterite Cu 2 ZnSn(S,Se) 4 (CZTSSe) is a sustainable material for thin‐film photovoltaics with device efficiencies greater than 12% have been demonstrated. Despite similar crystal structure and polycrystalline film microstructures, there is widespread evidence for larger‐amplitude potential and bandgap fluctuations in CZTS than in the analogous Cu(In,Ga)Se 2 (CIGSe) chalcopyrite material. This disorder is believed to account for a sizable part of the larger open‐circuit voltage ( V OC ) deficit in CZTS devices, yet the detailed origins and length scales of these fluctuations have not been fully elucidated. Herein, we present a transmission electron microscopy study focusing on composition variation within bulk multicrystals of CZTS grown by the travelling heater method (THM). In these slow‐cooled, solution grown crystals we find direct evidence for spatial composition fluctuations of amplitude <1 at.% (∼5 × 10 20 cm −3 ) and thus, explainable by point defects. However, rather than being homogeneously‐distributed we find a characteristic 20 nm length scale for these fluctuations, which sets a definite length scale for band gap and potential fluctuations. At Σ3 grain boundaries, we find no evidence of composition variation compared to the bulk. The finding highlights such variations reported at grain boundaries in polycrystalline thin‐films are direct consequences of processing methods and not intrinsic properties of CZTS itself.

Aguiar, Jeffery A.↗

Applications of analytical electron microscopy to guide the design of boron carbide

Compositional analysis of boron carbide on nanometer length scales to examine or interpret atomic mechanisms, for example, solid-state amorphization or grain-boundary segregation, is challenging. This work reviews advancements in high-resolution microanalysis to characterize multiple generations of boron carbide. First, ζ-factor microanalysis will be introduced as a powerful (scanning) transmission electron microscopy ((S)TEM) analytical framework to accurately characterize boron carbide. Three case studies involving the application of ζ-factor microanalysis will then be presented: (1) accurate stoichiometry determination of B-doped boron carbide using ζ-factor microanalysis and electron energy loss spectroscopy, (2) normalized quantification of silicon grain-boundary segregation in Si-doped boron carbide, and (3) calibration of a scanning electron microscope X-ray energy-dispersive spectroscopy (XEDS) system to measure compositional homogeneity differences of B/Si-doped arc-melted boron carbides in the as-melted and annealed conditions. Overall, the improvement and application of advanced analytical tools have helped better understand processing–microstructure–property relationships and successfully manufacture high-performance ceramics.

36 MATERIALS SCIENCE↗

Analytical electron microscopy of Mg-SiO smokes - A comparison with infrared and XRD studies

Analytical electron microscopy conducted for Mg-SiO smokes (experimentally obtained from samples previously characterized by IR spectroscopy) indicates that the microcrystallinity content of unannealed smokes increases with increased annealing for up to 30 hr. The growth of forsterite microcrystallites in the initially nonstoichiometric smokes may give rise to the contemporaneous growth of the SiO polymorph tridymite and MgO; after 4 hr of annealing, these react to form enstatite. It is suggested that XRD analysis and IR spectroscopy should be conducted in conjunction with detailed analytical electron microscopy for the detection of emerging crystallinity in vapor-phase condensates.

Rietmeijer, F. J. M.↗

Neutron irradiation effects on the corrosion of Zircaloy-4 in a pressurized water reactor environment - 2016-0085

Long-time Advanced Test Reactor (ATR) corrosion weight-gain data from non-fueled α-processed Zircaloy-4 cladding coupons are presented herein. The data were generated in pressurized loops that simulated pressurized water reactor (PWR) chemistry, temperature, and neutron flux conditions. High neutron flux and high-fluence post-transition corrosion rates were accelerated over out-of-flux post-transition corrosion rates by more than 40 times at 270 deg. C and more than 30 times at 310 deg. C We conclude in large part that the acceleration was caused by irradiation-induced changes to the base metal. The effect that irradiation has on the base metal and its effect on corrosion has been shown in the past to be carried over into post-irradiation tests in autoclave environments, but its impact was shown in this study to be accentuated in the in-reactor environment, in which sustained corrosion accelerations were much greater than observed in the postirradiation tests (in non-irradiation environments). This suggests some aspect of the radiation environment potentially acts synergistically with the corrosion film formed from the irradiation-damaged base metal to further accelerate in-reactor corrosion rates. We also present results from detailed microstructural examinations of thick (more than 25 μm) oxide films formed on α-processed Zircaloy-4 grown in a 360 deg. C autoclave and in the reactor. The examinations consisted of optical microscopy, field emission gun scanning electron microscopy, focused ion beam microscopy, analytical electron microscopy, and X-ray diffraction, with a focus on the evolution of the microstructure of the intermetallic precipitates in the oxide films during exposure to autoclave water or to the corroding environment under neutron irradiation. The film microstructure suggests that the water environment was closer to the oxide-metal interface in the films grown in the reactor than in the autoclave-grown corrosion films examined, but it was not obvious from the microstructural examinations how the radiation environment facilitated that effect. (authors)

36 MATERIALS SCIENCE↗

Probing Dynamic Phase Changes in Electrochemical Systems with Cryogenic and in Situ Analytical Electron Microscopy (Final Technical Report)

In this project, we focus on the advancement of our newly developed, unique in situ and cryogenic analytical electron microscopy (AEM) techniques and the development of additional high-end capabilities to quantitatively elucidate the mechanisms of resistive state changes in solid-state electrochemical materials for non-volatile, neuromorphic memory. The objectives of the proposed research are (1) to characterize and elucidate the mechanisms by which electronic state changes occur in various solid-state devices to build guiding principles for electrochemically activated smart materials; (2) to advance our understanding of such mechanisms by coupling cryogenic and in situ techniques to control kinetics of the observed mechanisms while mitigating probe-induced damage; and (3) to utilize additional advanced techniques including electron-beam induced current and quantum mechanical simulations in order to identify the underlying fundamental science of such processes, including roles of defect formation and its effect on phase nucleation, as well as dynamics of these processes in the electrochemical systems at the nanometer scale.

25 ENERGY STORAGE↗

Analytical electron microscopy of a hydrated interplanetary dust particle

Properties of a hydrated interplanetary dust particle (IDP), Ames-Dec86-11, were investigated using TEM and analytical electron microscopy. The particle was found to have mineralogy and chondritic composition indicating an absence of direct kinship with known carbonaceous chondrites. The available data on the Ames-Dec86-11 suggest that at least one aqueous alteration event took place in this hydrated IDP, during which fine-grained material, possibly glass, was transformed to smectite. This event appears to be unique to hydrated IDPs.

Blake, David F.↗

Dark Field Microscopy for Analytical Laboratory Courses

An innovative and inexpensive optical microscopy experiment for a quantitative analysis or an instrumental analysis chemistry course is described. The students have hands-on experience with a dark field microscope and investigate the wavelength dependence of localized surface plasmon resonance in gold and silver nanoparticles. Students also observe and measure individual crystal growth during a replacement reaction between copper and silver nitrate. The experiment allows for quantitative, qualitative, and image data analyses for undergraduate students.

36 MATERIALS SCIENCE↗

Study of the Reactive-element Effect in Oxidation of Fe-cr Alloys Using Transverse Section Analytical Electron Microscopy

The role of trace additions of reactive elements like Y, Ce, Th, or Hf to Cr bearing alloys was studied by applying a new developed technique of transverse section analytical electron microscopy. This reactive-element effect improves the high temperature oxidation resistance of alloys by strongly reducing the high temperature oxidation rate and enhancing the adhesion of the oxide scale, however, the mechanisms for this important effect remain largely unknown. It is indicated that the presence of yttrium affects the oxidation of Fe-Cr-Y alloys in at least two ways. The reactive element alters the growth mechanism of the oxide scale as evidenced by the marked influence of the reactive element on the oxide scale microstructure. The present results also suggest that reactive-element intermetallic compounds, which internally oxidize in the metal during oxidation, act as sinks for excess vacancies thus inhibiting vacancy condensation at the scale-metal interface and possibly enhancing scale adhesion.

King, W. E.↗

The role of light microscopy in aerospace analytical laboratories

Light microscopy has greatly reduced analytical flow time and added new dimensions to laboratory capability. Aerospace analytical laboratories are often confronted with problems involving contamination, wear, or material inhomogeneity. The detection of potential problems and the solution of those that develop necessitate the most sensitive and selective applications of sophisticated analytical techniques and instrumentation. This inevitably involves light microscopy. The microscope can characterize and often identify the cause of a problem in 5-15 minutes with confirmatory tests generally less than one hour. Light microscopy has and will make a very significant contribution to the analytical capabilities of aerospace laboratories.

Crutcher, E. R.↗

Oxidized structure and Compositional properties of 1144 phase FBS by analytical electron microscopy

The 1144 phase (Ae1A1Fe4As4) shows a strong advantage of engineering fabrication among Fe Iron)-based superconductor (FBS) family due to the robustness of its superconducting properties with respect to chemical inhomogeneities, granted by its uniform crystalline-layered structure. This regularity is furthermore associated to crystalline defects capable of acting as efficient pinning centers, which high critical currents achieved at high fields for these superconductors. Like other FBS phases, its lossless current-carrying capability can be remarkably degraded by distractions at grain boundaries (GBs). GB oxidation is an issue of upmost importance to the realization of the practical FBS application for high field (> 20T) magnet. In this study, we explore oxidized grain boundary and intrinsic grain structural properties of 1144 polycrystalline samples by applying analytical electron microscopy such as atomic resolution scanning transmission electron microscopy and atom probe tomography. These structural properties of samples produced by a mechanochemically assisted synthesis are evaluated following the degradation of superconducting properties due to oxidation. We observe a strong correlation between the contamination at grain boundaries and the decrease of transport properties of the bulk sample, while the crystallin structure seems to be not affected by the oxidation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analytical electron microscopy of biogenic and inorganic carbonates

In the terrestrial sedimentary environment, the mineralogically predominant carbonates are calcite-type minerals (rhombohedral carbonates) and aragonite-type minerals (orthorhombic carbonates). Most common minerals precipitating either inorganically or biogenically are high magnesium calcite and aragonite. High magnesium calcite (with magnesium carbonate substituting for more than 7 mole percent of the calcium carbonate) is stable only at temperatures greater than 700 C or thereabouts, and aragonite is stable only at pressures exceeding several kilobars of confining pressure. Therefore, these carbonates are expected to undergo chemical stabilization in the diagenetic environment to ultimately form stable calcite and dolomite. Because of the strong organic control of carbonate deposition in organisms during biomineralization, the microchemistry and microstructure of invertebrate skeletal material is much different than that present in inorganic carbonate cements. The style of preservation of microstructural features in skeletal material is therefore often quite distinctive when compared to that of inorganic carbonate even though wholesale recrystallization of the sediment has taken place. Microstructural and microchemical comparisons are made between high magnesium calcite echinoderm skeletal material and modern inorganic high magnesium calcite inorganic cements, using analytical electron microscopy and related techniques. Similar comparisons are made between analogous materials which have undergone stabilization in the diagenetic environment. Similar analysis schemes may prove useful in distinguishing between biogenic and inorganic carbonates in returned Martian carbonate samples.

Blake, David F.↗

High throughput crystal structure and composition mapping of crystalline nanoprecipitates in alloys by transmission Kikuchi diffraction and analytical electron microscopy

Statistically significant crystal structure and composition identification of nanocrystalline features such as nanoparticles/nanoprecipitates in materials chemistry and alloy designing using electron microscopy remains a grand challenge. In this paper, we reveal that differing crystallographic phases of nanoprecipitates in alloys can be mapped with unprecedented statistics using transmission Kikuchi diffraction (TKD), on typical carbon-based electron-transparent samples. Using a case of multiphase, multicomponent nanoprecipitates extracted from an improved version of 9% chromium Eurofer-97 reduced-activation ferritic-martensitic steel we show that TKD successfully identified more than thousand M 23 C 6 , MX, M 7 C 3 , and M 2 X ( M =Fe, Cr, W, V, Ta; X = C, N) nanoprecipitates in a single scan, something that is currently unachievable using a transmission electron microscope (TEM) without incorporating a precision electron diffraction (PED) system. Precipitates as small as ~20–25 nm were successfully phase identified by TKD. We verified the TKD phase identification using high-resolution transmission electron microscopy (HRTEM) and convergent beam electron diffraction (CBED) pattern analysis of a few precipitates that were identified by TKD on same sample. TKD study was combined with state-of-art analytical scanning transmission electron microscopy (STEM)-energy dispersive X-ray (EDX) spectroscopy and multivariate statistical analysis (MVSA) which provided the complete crystal structure and distinct chemistries of the precipitates in the steel in a high throughput automated way. This technique should be applicable to characterizing any multiphase crystalline nanoparticles or nanomaterials. Furthermore the results highlight that combining phase identification by TKD with analytical STEM and modern data analytics may open new pathways in big data material characterization at nanoscale that may be highly beneficial for characterizing existing materials and in designing new materials.

36 MATERIALS SCIENCE↗