Search NASA⌕ Search

SEARCH · Search NASA

Results for “anion exchange”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Thermal Characterization of Acid Treated Anion Exchange Resins

Anion exchange is a chemical separation and purification technique in which a solid phase ion exchanging material (i.e., anion exchange resin beads) interchanges its anions with the desired anions from a solution phase. Typical anion exchange resins (e.g., Bio-Rad AG 1-X8 strongly basic anion exchange resin) consist of a polymer resin bead of cross-linked polystyrene with quaternary ammonium functional groups (Figure 1). Anion exchange occurs at the resin functional groups by exchange of the counter ion of the quaternary ammonium (typically chloride or nitrate) for the anionic species of interest. Other resin polymers have been developed—such as cross-linked vinylpyridine/divinylbenzene utilized in Reillex HPQ anion exchange resin—to improve the resins’ resistance against degradation by oxidizing agents, strong acids, and radiation. Anion exchange is performed for the separation of transuranic (TRU) elements throughout the Department of Energy complex. At the Los Alamos National Laboratory (LANL), production scale quantities of these resins are handled at the Chemistry and Metallurgy Research Facility, the Plutonium Facility, and the Transuranic Waste Facility. Spent anion exchange resin will eventually be disposed of as TRU waste. This has prompted concerns regarding its safe disposal under potential hazard scenarios, in particular a thermal excursion of a TRU waste drum. There is a concern that a potential thermal excursion of a TRU waste drum containing anion exchange resin previously contacted with nitric acid may result in energetic side reactions and pressure buildup due to resin degradation by nitric acid and heat. Therefore, the objective of the experiments described in this report was to gather qualitative and quantitative data to support decisions regarding the thermal stability and safe disposal strategy of nitric acid treated anion exchange resins utilized in TRU processing operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electrospun Composite Proton-Exchange and Anion-Exchange Membranes for Fuel Cells

A fuel cell is an electrochemical device that converts the chemical energy of a fuel and oxidant into electricity. Cation-exchange and anion-exchange membranes play an important role in hydrogen fed proton-exchange membrane (PEM) and anion-exchange membrane (AEM) fuel cells, respectively. Over the past 10 years, there has been growing interest in using nanofiber electrospinning to fabricate fuel cell PEMs and AEMs with improved properties, e.g., a high ion conductivity with low in-plane water swelling and good mechanical strength under wet and dry conditions. Electrospinning is used to create either reinforcing scaffolds that can be pore-filled with an ionomer or precursor mats of interwoven ionomer and reinforcing polymers, which after suitable processing (densification) form a functional membrane. In this review paper, methods of nanofiber composite PEMs and AEMs fabrication are reviewed and the properties of these membranes are discussed and contrasted with the properties of fuel cell membranes prepared using conventional methods. The information and discussions contained herein are intended to provide inspiration for the design of high-performance next-generation fuel cell ion-exchange membranes.

25 ENERGY STORAGE↗

Ether Cleavage Decreases the Ion Exchange Capacity of Anion Exchange Membranes

Anion exchange membranes (AEMs) are integral to fuel cells and water electrolysis systems but suffer from poor durability under alkaline conditions. Ether cleavage is an important failure pathway of poly(arylene ether)-based AEMs that compromises both mechanical stability and ion transport. While this degradation pathway is often studied in terms of polymer fragmentation, the role of newly formed hydrophilic groups has been largely overlooked. Here, we show that polymer scission leads to reduced mechanical rigidity, while the introduction of hydrophilic groups partially mitigates this loss. Under alkaline conditions, phenoxide groups formed during ether cleavage neutralize the polymer cations, leading to a previously unreported loss of ion exchange capacity (IEC). This IEC loss mechanism exacerbates the reduction in ionic conductivity, emphasizing the severity of ether cleavage as a degradation pathway. Recognizing that ether cleavage introduces significant chemical changes beyond polymer fragmentation provides critical insights into its interplay with other degradation mechanisms, such as the direct reduction of cationic sites by E2 and S N 2, and provides molecular-level interpretations for the concurrent effects of polymer scission and increased hydrophilicity on membrane performance.

crystal cleavage↗

Cation Exchange Capacity, Anion Exchange Capacity, and Mineralogy of F-Area Aquifer Sediments

Strontium-90 (Sr-90) is a contaminant of concern in groundwater and surface water at both F-Area and H-Area Seepage Basins. This contaminant was disposed of, along with other heavy metals and radionuclides, into a series of unlined seepage basins from 1955 until 1988. The acidity of the wastewater increased Sr-90 mobility from the basin soil through the vadose zone and into the Upper Aquifer Zone (UAZ), creating a groundwater plume that discharges into wetlands areas and a local stream called Fourmile Branch.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Separation of dilute plutonium(IV) from nitric acid solutions via Reillex HPQ anion exchange resin

Anion exchange is a common method for the separation of plutonium (Pu) in aqueous systems, providing high recovery and decontamination from impurities. Reillex HPQ anion exchange resin has been used around the Department of Energy complex in this application for decades but has typically been used for Pu feed concentrations greater than 1 g/L. It is desirable to recover Pu at more dilute concentrations from a dissolved used fuel or target element, for example. In this work, the performance of Reillex HPQ anion exchange resin was characterized with feed solutions of ca. 0.24 g/L Pu. A significant reduction in the performance of the resin was realized with this dilute concentration relative to a feed solution of 2.35 g/L Pu with similar feed flow rates and the same resin column, likely due to the increased driving force for mass transfer with a higher feed concentration. The maximum capacity of Reillex HPQ resin for Pu can be improved by reducing the flow rate and increasing the feed Pu concentration. Furthermore, the breakthrough point of Pu can be improved in the same manner and by increasing the resin bed height. Diffusion of Pu into the resin was illustrated to be the rate limiting step.

Plutonium separations↗

Editors’ Choice—Examining Performance and Durability of Anion Exchange Membrane Fuel Cells with Novel Spirocyclic Anion Exchange Membranes

A series of spirocyclic copolymer membranes with varying ion exchange capacities (IECs) were investigated to probe the impact of polymer properties on in situ fuel cell performance and stability. In-situ electrochemical tests and post-mortem electron microscopy analysis of cross-sectioned membrane electrode assemblies (MEAs) have been combined with voltage loss breakdown analysis to evaluate the performance and degradation of different MEAs, and to probe the catalyst morphology and electrode structure at different stages of operation. Voltage loss breakdown results show that membrane degradation and kinetic losses played only a minor role in observed performance degradation and that performance losses were primarily related to increasing mass transport losses. From microscopy studies, carbon corrosion and Pt nanoparticle growth were identified at both the cathode and anode although more pronounced on the cathode resulting in significant structural changes. The membrane with the lowest IEC (1.3 mmolg −1 ) demonstrated the lowest peak power density ~ 1.16 W cm −2 , however, it showed the most stable performance (constant 0.6 A cm −2 hold) with ~ 5% degradation over 540 h. Isolation of performance losses and microscopic analysis of electrodes for anion exchange membrane fuel cells has not been reported previously, and these results help identify critical performance degradation concerns.

25 ENERGY STORAGE↗

Standard Operating Protocol for Ion-Exchange Capacity of Anion Exchange Membranes

Ion-exchange capacity (IEC) is the measure of a material’s capability to displace ions formerly incorporated within its structure. IEC is a key feature of anion-exchange membranes (AEM), as it determines the AEM’s ability to conduct the ions required to sustain the electrochemical reactions where they are utilized. As an intrinsic property, measuring the IEC accurately is essential to study AEMs and understand their performance within devices. In this method article, a facile and accurate standard operating procedure (SOP) to measure the IEC of AEMs is proposed. When compared to conventional acid-base back-titration or Mohr titration, the proposed method combines the fast reaction between silver and halide ions and the accuracy of the potentiometric titration, providing a convenient and precise protocol for researchers in the field.

42 ENGINEERING↗

Ionomer Optimization for Water Uptake and Swelling in Anion Exchange Membrane Electrolyzer: Hydrogen Evolution Electrode

Green hydrogen produced through anion exchange membrane water electrolysis is a promising, low-cost chemical storage solution for intermittent renewable energy sources. Low-temperature electrolysis using anion exchange membranes (AEM) combines the benefits of established water electrolysis technologies based on alkaline electrolysis and proton exchange membrane electrolysis. The anion conductive ionomers (ACI) used in the AEM electrolyzer (AEMEL) electrodes has been investigated. The ACI serves two primary purposes: (i) facilitate hydroxide conduction between the catalyst and bulk electrolyte and (ii) bind the catalyst to the porous transport layer and membrane. High ion exchange capacity (IEC) ACIs are desired, however, high IEC can cause excessive water uptake (WU) and detrimental ACI swelling. Proper water management is a key factor in obtaining maximum performance in AEM-based devices. In this study, a series of poly(norbornene)-based ACIs were synthesized and deployed in hydrogen evolving AEMEL cathode electrodes. A balance between ionic conductivity, WU and ionomer swelling was achieved in the ACI by varying the IEC and degree of polymer cross-linking. It was found that higher IEC ACIs with light crosslinking are preferred in the HER electrode. Furthermore, such a configuration fine-tuned the WU and ionomer swelling to achieve optimum cell performance and reduce cell operating voltages.

08 HYDROGEN↗

Increasing the Electrolyte Salinity to Improve the Performance of Anion Exchange Membrane Water Electrolyzers

Direct operation of anion exchange membrane water electrolyzers (AEMWEs) with near-neutral pH feeds avoids the use of highly alkaline and corrosive solutions. However, using neutral pH solutions currently faces fundamental operational challenges that diminish performance and reduce long-term stability due to poor solution conductivity and low hydroxide ion concentration. Here, we showed that amending near-neutral pH solutions with low concentrations of alkali metal salts in a dry-cathode configuration substantially improved performance and stability. Adding NaClO 4 (10 mM) to the anolyte reduced the operating voltage by 0.19 to 2.58 V at 500 mA/cm 2 compared to non-saline solutions (2.77 V). However, further increases in the feed salt concentration (100 mM NaClO 4 ) reduced performance (2.64 V) due to a greater co-ion diffusion through the anion exchange membrane. Electrolyzer performance was further improved by utilizing salts with high conductivity such as KNO 3 . Using a saline anolyte reduced ohmic resistance, resulting in smaller applied voltage and energy consumption for hydrogen generation, while the combined effect of the membrane charge and the electric field direction in the dry-cathode feed configuration minimized ion crossover. Thus, increasing the salinity of near-neutral pH solutions represents a cost-effective strategy to improve the performance of AEMWE compared to ultrapure electrolytes, minimizing risks and costs associated with recirculating highly alkaline solutions.

anion exchange membrane water electrolyzer↗

Assessing the Long-Term Stability of Anion Exchange Membranes for Electrochemical CO 2 Reduction

Materials and cell components used in CO 2 electrolysis have largely been adapted from technologies initially developed for water electrolysis and fuel cells. However, electrochemical CO 2 reduction introduces distinct material challenges due to the unique chemical environment in this process. Here, in this study, we conducted ex-situ 1000 h stability tests on commonly used anion exchange membranes, exposing them exclusively to electrolytes and organic molecules used or produced during CO 2 electrolysis, at concentrations relevant to and compatible with postseparation processes. Notably, 15% w/w n-propanol and 5 M acetic acid caused complete dissolution or partial disintegration of the membranes unless cross-linking was present and remained stable throughout the test. When the membranes stayed physically intact, most of them exhibited excellent chemical stability in alkaline medium containing alcohols or formic acid, which was confirmed by vibrational spectroscopy and ion exchange capacity measurements. However, exposure to alcohol-and acid-containing solutions led to a substantial increase in swelling and water uptake, with potential implications for mechanical stability, ion/product crossover, and compression management of adjacent components. The potential effects of CO 2 electroreduction products on membrane stability, their subsequent impact on electrolyzer performance, and mitigation strategies are discussed.

CO2RR↗

Three-Electrode Study of Electrochemical Ionomer Degradation Relevant to Anion-Exchange-Membrane Water Electrolyzers

Among existing water electrolysis (WE) technologies, anion-exchange-membrane water electrolyzers (AEMWEs) show promise for low-cost operation enabled by the basic solid-polymer electrolyte used to conduct hydroxide ions. The basic environment within the electrolyzer, in principle, allows the use of non-platinum-group metal catalysts and less-expensive cell components compared to acidic-membrane systems. Nevertheless, AEMWEs are still underdeveloped, and the degradation and failure modes are not well understood. To improve performance and durability, supporting electrolytes such as KOH and K 2 CO 3 are often added to the water feed. The effect of the anion interactions with the ionomer membrane (particularly other than OH – ), however, remains poorly understood. We studied three commercial anion-exchange ionomers (Aemion, Sustainion, and PiperION) during oxygen evolution (OER) at oxidizing potentials in several supporting electrolytes and characterized their chemical stability with surface-sensitive techniques. We analyzed factors including the ionomer conductivity, redox potential, and pH tolerance to determine what governs ionomer stability during OER. Specifically, we discovered that the oxidation of Aemion at the electrode surface is favored in the presence of CO 3 2– /HCO 3 – anions perhaps due to the poor conductivity of that ionomer in the carbonate/bicarbonate form. Sustainion tends to lose its charge-carrying groups as a result of electrochemical degradation favored in basic electrolytes. PiperION seems to be similarly negatively affected by a pH drop and low carbonate/bicarbonate conductivity under the applied oxidizing potential. Furthermore, the insight into the interactions of the supporting electrolyte anions with the ionomer/membrane helps shed light on some of the degradation pathways possible inside of the AEMWE and enables the informed design of materials for water electrolysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultraviolet-Activated Solid-State Nitrene Cross-Linking: A Scalable Pathway to Prolonged Lifespan in Anion Exchange Membranes

Anion exchange membranes (AEMs) offer a cost-effective alternative to proton exchange membranes as alkaline fuel cells and electrolyzers permit the use of non-platinum group electrodes and components. Despite continued progress, the operational lifetime and stability of these membranes limit the widespread adoption of AEM-based electrochemical technologies. This study presents a flexible and easily implemented ultraviolet (UV)-initiated nitrene-based cross-linking method which uses a small, facile organic azide precursor. As a proof of concept, we demonstrate this approach on the well-studied poly(2,6-dimethyl-1,4-phenylene oxide) quaternary ammonium AEM (QPPO) polyelectrolyte. Further, a survey of cross-linker density (2.5–10 mol %) found that the addition of 10 mol % results in a 59% reduction in water uptake, a 58.8% decrease in the swell ratio, and a 31% increase in tensile strength vs the un-cross-linked material. Nitrene cross-linking also enhanced the membrane’s durability, enabling 1000 h of stable performance under electrochemical load. This UV-initiated cross-linking method may be easily integrated into production processes, allowing chemical cross-linking at any stage, including posthydration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance and Durability of Pure-Water-Fed Anion Exchange Membrane Electrolyzers Using Baseline Materials and Operation

Water electrolysis powered by renewable electricity produces green hydrogen and oxygen gas, which can be used for energy, fertilizer, and industrial applications and thus displace fossil fuels. Pure-water anion-exchange-membrane (AEM) electrolyzers in principle offer the advantages of commercialized proton-exchange-membrane systems (high current density, low cross over, output gas compression, etc.) while enabling the use of less-expensive steel components and nonprecious metal catalysts. AEM electrolyzer research and development, however, has been limited by the lack of broadly accessible materials that provide consistent cell performance, making it difficult to compare results across studies. Further, even when the same materials are used, different pretreatments and electrochemical analysis techniques can produce different results. Here, we report an AEM electrolyzer comprising commercially available catalysts, membrane, ionomer, and gas-diffusion layers operating near 1.9 V at 1 A cm –2 in pure water. After the initial break in, the performance degraded by 0.67 mV h –1 at 0.5 A cm –2 at 55 °C. We detail the key preparation, assembly, and operation techniques employed and show further performance improvements using advanced materials as a proof-of-concept for future AEM-electrolyzer development. Here, the data thus provide an easily reproducible and comparatively high-performance baseline that can be used by other laboratories to calibrate the performance of improved cell components, nonprecious metal oxygen evolution, and hydrogen evolution catalysts and learn how to mitigate degradation pathways.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-performing commercial Fe–N–C cathode electrocatalyst for anion-exchange membrane fuel cells

Here, to reduce the cost of fuel cell stacks and systems, it is important to create commercial catalysts that are free of platinum group metals (PGMs). To do this, such catalysts must have very high activity, but also have the correct microstructure to facilitate the transport of reactants and products. Here, we show a high-performing commercial oxygen reduction catalyst that was specifically developed for operation in alkaline media and is demonstrated in the cathode of operating anion-exchange membrane fuel cells (AEMFCs). With H 2 /O 2 reacting gases, AEMFCs made with Fe–N–C cathodes achieved a peak power density exceeding 2 W cm –2 (>1 W cm –2 with H 2 /air) and operated with very good voltage durability for more than 150 h. These AEMFCs also realized an iR-corrected current density at 0.9 V of 100 mA cm –2 . Finally, in a second configuration, Fe–N–C cathodes paired with low-loading PtRu/C anodes (0.125 mg PtRu per cm 2 , 0.08 mg Pt per cm 2 ) demonstrated a specific power of 10.4 W per mg PGM (16.25 W per mg Pt).

25 ENERGY STORAGE↗

Achieving High‐Performance and 2000 h Stability in Anion Exchange Membrane Fuel Cells by Manipulating Ionomer Properties and Electrode Optimization

The primary function of the ionomers that are incorporated into fuel cell electrode catalyst layers is to provide pathways for ion transport between the catalyst active sites and the electrolyte. This is influenced by many variables, including the ion-exchange capacity, water uptake, and molecular weight. In anion exchange membrane fuel cells (AEMFCs), controlling ionomer water uptake is particularly important and tailoring this property in each electrode is an important consideration when looking to maximize cell performance. In this study, three poly(norbornene) tetrablock copolymer ionomers with a range of physical properties are synthesized and incorporated into AEMFC anode and cathode electrodes. Systematic electrode engineering with these ionomers allows the peak power density to be increased by 100% (1.6 W cm -2 → 3.2 W cm -2 ) and the current density at 0.2 V to be increased by 59% (5.9 A cm -2 → 9.4 A cm -2 ). Moreover, the top-performing electrode configuration is tested in an operating AEMFC at the US Department of Energy defined current density of 600 mA cm -2 for 2000 h, showing a record-low voltage decay rate of 15.36 µV h -1 – only 3.65% –a over 2000 h. Here, this work sets a new bar for AEMFCs, reporting the best combination of performance and durability of any AEMFC to date.

08 HYDROGEN↗