Search NASA⌕ Search

SEARCH · Search NASA

Results for “anodic stripping voltammetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Thin Film Electrodes for Anodic Stripping Voltammetry: A Mini-Review

Anodic stripping voltammetry (ASV) is a powerful electrochemical analytical technique that allows for the detection and quantification of a variety of metal ion species at very low concentrations in aqueous media. While early, traditional ASV measurements relied on macroscopic electrodes like Hg drop electrodes to provide surfaces suitable for plating/stripping, more recent work on the technique has replaced these electrodes with thin film metal electrodes generated in situ . Such electrodes are plated alongside the analyte species onto the surface of a primary electrode, producing a composite metal electrode from which the analyte(s) can then be stripped, identified, and quantified. In this minireview, we will explore the development and use of these unique electrodes in a variety of different applications. A number of metals (e.g., Hg, Bi, Sn, etc.) have shown promise as thin film ASV electrodes in both acidic and alkaline media, and frequently multiple metals in addition to the analyte of interest are deposited together to optimize the plating/stripping behavior, improving sensitivity. Due to the relatively simple nature of the measurement and its suitability for a wide range of pH, it has been used broadly: To measure toxic metals in the environment, characterize battery materials, and enable biological assays, among other applications. We will discuss these applications in greater detail, as well as provide perspective on future development and uses of these thin film electrodes in ASV measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bismuth Detection in Alkaline Electrolyte via Anodic Stripping Voltammetry for Battery Separator Evaluation

Abstract Anodic stripping voltammetry (ASV) has been widely used for the detection of several heavy metal ions in neutral and acidic solution, in many cases employing electrodes and/or solutions incorporating Bi. In this work we demonstrate that Bi(OH) 4 − ion concentration can be measured in highly alkaline 8.5 M KOH solution using ASV. The addition of Pb in similar concentrations to the Bi(OH) 4 − being measured is shown to improve both the sensitivity and precision of the method. When the Pb additive is employed, a formal limit of detection of 8.5 ppb is achieved, compared to 17.3 ppb when the Pb additive is not used. Due to the use of Bi additives in alkaline battery chemistries, it follows that separators which limit Bi(OH) 4 − diffusion into the bulk electrolyte and away from the electrodes are of interest. For this purpose, we utilize ASV to determine Bi(OH) 4 − diffusion rates through Celgard 3501, cellophane 350P00, and Nafion 211. Bi(OH) 4 − crossover rates, as determined by ASV, are shown to be repeatable and consistent with expectations from the known separator structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Copper Sensing in Alkaline Electrolyte Using Anodic Stripping Voltammetry by Means of a Lead Mediator

Anodic stripping voltammetry (ASV) is an analysis technique that permits the selective and quantitative analysis of metal ion species in solution. It is most commonly applied in neutral to acidic electrolyte largely due to inherent metal ion solubility. Bismuth (Bi) is a common film used for ASV due to its good sensitivity, overall stability and insensitivity to O2. ASV, utilizing a Bi film, along with cadmium (Cd) and lead (Pb) as the plating mediators, has recently been adapted to determine zinc (Zn) concentrations in highly alkaline environments (30 % NaOH or 35 % M KOH). Successful analysis of Zn in alkaline relies on the ability of the hydroxide to form soluble metal anion species, such as Bi(OH) 4 – and Zn(OH) 4 2– . Here, we look to extend this technique to detect and quantify copper (Cu) ions in these highly basic electrolytes. However, in general, the use of ASV to detect and quantify Cu ion concentrations is notoriously difficult as the Cu stripping peak potential overlays with that of Bi from the common Bi film electrode. Here, an ASV method for determining Cu concentration in alkaline solutions is developed utilizing Pb as a deposition mediator. As such, it was found that when analyzing Cu solutions in the presence of Pb, the stripping voltammetry curves present separate and defined Cu stripping peaks. Different analyzes were made to find the best stripping voltammetry performance conditions. As such, an accumulation time of 5 minutes, an accumulation potential of ≤–1.45 V vs. Hg/HgO, and a concentration of 35 wt% KOH were determined to be the conditions that presented the best ASV results. Utilizing these conditions, calibration curves in the presence of 5.0 ppm Pb showed the best linear stripping signal correlation with an r-squared value of 0.991 and a limit of detection (LOD) of 0.67 ppm. Lastly, these results give way to evaluating Cu concentrations using ASV in aqueous alkaline solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiplexed Anodic Stripping Voltammetry Detection of Heavy Metals in Water Using Nanocomposites Modified Screen-Printed Electrodes Integrated With a 3D-Printed Flow Cell

In this study, we present multiplexed anodic stripping voltammetry (ASV) detection of heavy metal ions (HMIs)—As(III), Cd(II), and Pb(II)—using a homemade electrochemical cell consisting of dual working, reference and counter screen-printed electrodes (SPE) on polyimide substrate integrated with a 3D-printed flow cell. Working and counter electrodes were fabricated by the screen-printing of graphite paste while the Ag/AgCl paste was screen-printed as a reference electrode (Ag/AgCl quasi-reference electrode). The working electrodes were modified with (BiO) 2 CO 3 -reduced graphene oxide (rGO)-Nafion [(BiO) 2 CO 3 -rGO-Nafion] and Fe 3 O 4 magnetic nanoparticles (Fe 3 O 4 MNPs) decorated Au nanoparticles (AuNPs)-ionic liquid (IL) (Fe 3 O 4 -Au-IL) nanocomposites separately to enhance HMIs sensing. Electrochemical detection was achieved using square wave ASV technique. The desired structure of the flow electrochemical cell was optimized by the computational fluid dynamic (CFD). Different experimental parameters for stripping analysis of HMIs were optimized including deposition time, deposition potential and flow rate. The linear range of calibration curves with the sensing nanocomposites modified SPE for the three metal ions was from 0–50 μg/L. The limits of detection (S/N = 3) were estimated to be 2.4 μg/L for As(III), 1.2 μg/L for Pb(II) and 0.8 μg/L for Cd(II). Furthermore, the homemade flow anodic stripping sensor platform was used to detect HMIs in simulated river water with a 95–101% recovery, indicating high selectivity and accuracy and great potential for applicability even in complex matrices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Anodic stripping voltammetry of synthesized CdS nanoparticles at boron-doped diamond electrodes

Cadmium sulphide (CdS) nanoparticles were chemically synthesized using reverse micelles microreactor methods. By using different washing treatments, UV-Vis spectroscopy showed that the absorption peaks appeared at 465 nm, 462 nm, 460 nm, and 459 nm respectively for CdS nanoparticles without and with 1, 2, and 3 times washing treatments using pure water. In comparison with the absorbance peak of bulk CdS at 512 nm, the shifted absorption peaks, indicates that the different sizes of CdS can be prepared. Anodic stripping voltammetry of the CdS nanoparticles was then studied at a boron-doped diamond electrode using 0.1 M KClO{sub 4} and 0.1 M HClO{sub 4} as the electrolytes. A scan rate of 100 mV/s with a deposition potential of -1000 mV (vs. Ag/AgCl) for 60 s at a potential scan from -1600 mV to +800 mV (vs. Ag/AgCl) was applied as the optimum condition of the measurements. Highly-accurate linear calibration curves (R{sup 2} = 0.99) in 0.1 M HClO{sub 4} with the sensitivity of 0.075 mA/mM and the limit of detection of 81 µM in 0.1 M HClO{sub 4} can be achieved, which is promising for an application of CdS nanoparticles as a label for biosensors.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Applying Anodic Stripping Voltammetry to Complex Wastewater Streams for Rapid Metal Detection (Final Report)

The overall objective of this project is the development of a lab-on-a-chip (LOC) electrochemical sensor capable of accurately measuring heavy metal (lead (Pb), cadmium (Cd), and arsenic (As)) concentrations in complex aqueous streams such as wastewater. The specific goals include: i) identify how heavy metal speciate and transform during the different stages of the wastewater treatment train, and explore pre-treatment methods that will de-complex heavy metals, making them available to ASV, ii) develop appropriate electrodes for ASV using organic/inorganic nanomaterials, and iii) integrate pre-treatment steps and specialized electrodes into an LOC sensor device capable of autonomously determining heavy metal concentrations in complex wastewater streams.

99 GENERAL AND MISCELLANEOUS↗

Bismuth Subcarbonate Decorated Reduced Graphene Oxide Nanocomposite for the Sensitive Stripping Voltammetry Analysis of Pb(II) and Cd(II) in Water

In this paper, bismuth subcarbonate (BiO)2CO3-reduced graphene oxide nanocomposite incorporated in Nafion matrix ((BiO)2CO3-rGO-Nafion) was synthesized and further applied, for the first time, in the sensitive detection of Pb(II) and Cd(II) by square-wave anodic stripping voltammetry (SWASV). The as-synthesized nanocomposites were characterized by energy-dispersive spectroscopy (EDS), Raman spectroscopy, scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). (BiO)2CO3 composite plays a key role in the improvement of the detection sensitivity, which can form multicomponent alloy with cadmium and lead. Additionally, the unique structure of rGO can enlarge the surface area and provide abundant active sites. Moreover, Nafion incorporation in the nanocomposite can effectively increase the adhesion and mechanical strength of the film, and further improve the preconcetration ability due to the cation-exchange capacity of its abundant sulfonate groups. As expected, the (BiO)2CO3-rGO/Nafion nanocomposite-modified glassy carbon electrode ((BiO)2CO3-rGO-Nafion/GCE) achieved low detection limits of 0.24 μg/L for Pb(II) and 0.16 μg/L for Cd(II), in the linear range of 1.0–60 μg/L, and showed some excellent performance, such as high stability, good selectivity, and sensitivity. Finally, synthetic water samples were prepared and further used to verify the practicability of the (BiO)2CO3-rGO-Nafion/GCE with satisfactory results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Linker-Free Magnetite-Decorated Gold Nanoparticles (Fe3O4-Au): Synthesis, Characterization, and Application for Electrochemical Detection of Arsenic (III)

Linker-free magnetite nanoparticles (Fe3O4NPs)-decorated gold nanoparticles (AuNPs) were grown using a new protocol that can be used as a new platform for synthesis of other intact metal–metal oxide nanocomposites without the need for linkers. This minimizes the distance between the metal and metal oxide nanoparticles and ensures the optimum combined effects between the two material interfaces. X-ray diffraction (XRD) and Fourier transform infrared (FTIR) spectroscopy confirmed the successful synthesis of the Fe3O4-Au nanocomposite, without any change in the magnetite phase. Characterization, using transmission electron microscopy (TEM), scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) spectroscopy, revealed the composite to consist of AuNPs of 70 ± 10 nm diameter decorated with tiny 10 ± 3 nm diameter Fe3O4NPs in Au:Fe mass ratio of 5:1. The prepared Fe3O4-Au nanocomposite was embedded in ionic liquid (IL) and applied for the modification of glassy carbon electrode (GCE) for the electrochemical detection of As(III) in water. By combining the excellent catalytic properties of the AuNPs with the high adsorption capacity of the tiny Fe3O4NPs towards As(III), as well as the good conductivity of IL, the Fe3O4-Au-IL nanocomposite showed excellent performance in the square wave anodic stripping voltammetry detection of As(III). Under the optimized conditions, a linear range of 1 to 100 μg/L was achieved with a detection limit of 0.22 μg/L (S/N = 3), and no interference from 100-fold higher concentrations of a wide variety of cations and anions found in water. A very low residual standard deviation of 1.16% confirmed the high precision/reproducibility of As(III) analysis and the reliability of the Fe3O4-Au-IL sensing interface. Finally, this proposed sensing interface was successfully applied to analyzing synthetic river and wastewater samples with a 95–101% recovery, demonstrating excellent accuracy, even in complex synthetic river and wastewater samples containing high concentrations of humic acid without any sample pretreatments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Self-Assembled Bolaamphiphile-Based Organic Nanotubes as Efficient Cu(II) Ion Adsorbents

Self-assembled organic nanotubes (ONTs) have been actively examined for various applications such as chemical separations and catalysis owing to their well-defined tubular nanostructures with distinct chemical environments at the wall and internal/external surfaces. Adsorption of heavy metal ions onto ONTs plays an essential role in many of these applications, but it has rarely been assessed quantitatively. Herein, we investigated interactions between Cu 2+ and single-/quadruple-wall bolaamphiphile-based ONTs having inner carboxyl groups with different inner diameters, COOH-ONT 10nm and COOH-ONT 20nm . We first examined the effects of Cu 2+ on their nanotubular structures using SAXS, STEM, and AFM. COOH-ONT 10nm was stable in aqueous Cu 2+ solution in contrast to COOH-ONT 20nm owing to the presence of polyglycine-II-type hydrogen bonding networks within its wall. Subsequently, we studied the Cu 2+ adsorption behavior of COOH-ONT 10nm by monitoring the concentration of unbound Cu 2+ using linear sweep anodic stripping voltammetry. The Cu 2+ adsorption was quick, attributable to efficient Cu 2+ partitioning through the open ends of the ONT, followed by fast Cu 2+ diffusion in the uniform, relatively large nanochannel. More importantly, the Cu 2+ adsorption capacity and affinity of COOH-ONT 10nm were measured at different pH using the Langmuir adsorption model. The adsorption capacity was similar at the pH range examined, showing the participation of approximately 25% of the inner carboxyl groups in the adsorption. The adsorption affinity increased with pH, indicating the essential role of the deprotonated carboxyl groups in the Cu 2+ adsorption. Most interestingly, the Langmuir adsorption constant was significantly higher than those of previously reported synthetic adsorbents and planar monolayer based on carboxyl binding sites. The high Cu 2+ affinity of the ONT was attributable to the highly dense binding sites on the well-defined nanoscale concave structure of the inner channel. Furthermore, these results provide a valuable guideline to designing self-assembled nanomaterials for efficient chemical separations, detection, and catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wearable Microsensor Array for Multiplexed Heavy Metal Monitoring of Body Fluids

A flexible and wearable microsensor array is described for simultaneous multiplexed monitoring of heavy metals in human body fluids. Zn, Cd, Pb, Cu, and Hg ions are chosen as target analytes for detection via electrochemical square wave anodic stripping voltammetry (SWASV) on Au and Bi microelectrodes. The oxidation peaks of these metals are calibrated and compensated by incorporating a skin temperature sensor. High selectivity, repeatability, and flexibility of the sensor arrays are presented. Human sweat and urine samples are collected for heavy metal analysis, and measured results from the microsensors are validated through inductively coupled plasma mass spectrometry (ICP-MS). Real-time on-body evaluation of heavy metal (e.g., zinc and copper) levels in sweat of human subjects by cycling is performed to examine the change in concentrations with time. Finally, this platform is anticipated to provide insightful information about an individual's health state such as heavy metal exposure and aid the related clinical investigations.

47 OTHER INSTRUMENTATION↗

Kinetic Parameters and Diffusivity of Uranium in FLiNaK and ClLiK

Anodic stripping voltammetry (ASV) and cyclic voltammetry (CV) measurements at 773, 823, and 873 K were made of uranium trifluoride (UF 3 ) in lithium fluoride-sodium fluoride-potassium fluoride eutectic (FLiNaK) and uranium trichloride (UCl 3 ) in lithium chloride-potassium chloride eutectic (ClLiK). ASV data were used to estimate the charge transfer coefficients, exchange current densities, and activation energies of the uranium reactions. Charge transfer coefficients of both salt systems were within the range of 0.17 to 0.38. Exchange current densities in the fluoride and chloride salts were estimated within the range of 0.060 to 0.12 A cm -2 . Activation energy of uranium exchange current was 16.0 kJ mol -1 in the fluoride salt and 28.9 kJ mol -1 in the chloride salt. Kinetics of charge transfer were found to be faster in FLiNaK. Analyses of the CV data suggest the electrochemical system was diffusion controlled and irreversible in the chloride and fluoride salt mixtures. Diffusion coefficients of uranium in the range of temperatures were on the order of 10-5 cm 2 s -1 in both systems. Greater values of diffusivity in ClLiK are attributed to its lower density compared with FLiNaK. Activation energy of uranium diffusion in the fluoride and chloride salt mixtures were 53.4 and 89.4 kJ mol -1 , respectively.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗