Echocardiography of the aortic valve. I - Studies of normal aortic valve, aortic stenosis, aortic regurgitation, and mixed aortic valve disease
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
OBJECTIVE: We sought to assess whether aortic valve replacement (AVR) among patients with severe aortic stenosis (AS), severe left ventricular (LV) dysfunction and a low transvalvular gradient (TVG) is associated with improved survival. BACKGROUND: The optimal management of patients with severe AS with severe LV dysfunction and a low TVG remains controversial. METHODS: Between 1990 and 1998, we evaluated 68 patients who underwent AVR at our institution (AVR group) and 89 patients who did not undergo AVR (control group), with an aortic valve area < or = 0.75 cm(2), LV ejection fraction < or = 35% and mean gradient < or = 30 mm Hg. Using propensity analysis, survival was compared between a cohort of 39 patients in the AVR group and 56 patients in the control group. RESULTS: Despite well-matched baseline characteristics among propensity-matched patients, the one- and four-year survival rates were markedly improved in patients in the AVR group (82% and 78%), as compared with patients in the control group (41% and 15%; p < 0.0001). By multivariable analysis, the main predictor of improved survival was AVR (adjusted risk ratio 0.19, 95% confidence interval 0.09 to 0.39; p < 0.0001). The only other predictors of mortality were age and the serum creatinine level. CONCLUSIONS: Among select patients with severe AS, severe LV dysfunction and a low TVG, AVR was associated with significantly improved survival.
When left ventricular outflow tract obstruction develops after aortic valve replacement, few treatment choices have been available until now. We present a patient with prior aortic valve replacement who developed left ventricle outflow tract obstruction that was successfully treated with a percutaneous transcoronary myocardial septal alcohol ablation. This technique is a useful tool for the treatment of obstructive hypertrophic cardiomyopathy, especially in those patients with prior heart surgery. Copyright 2001 Wiley-Liss, Inc.
Abstract Aim Lipoprotein(a) [Lp(a)] is a potential causal factor in the pathogenesis of aortic valve disease. However, the relationship of Lp(a) with new onset and progression of aortic valve calcium (AVC) has not been studied. The purpose of the study was to assess whether high serum levels of Lp(a) are associated with AVC incidence and progression. Methods and results A total of 922 individuals from the population-based Rotterdam Study (mean age 66.0±4.2 years, 47.7% men), whose Lp(a) measurements were available, underwent non-enhanced cardiac computed tomography imaging at baseline and after a median follow-up of 14.0 [interquartile range (IQR) 13.9–14.2] years. New-onset AVC was defined as an AVC score >0 on the follow-up scan in the absence of AVC on the first scan. Progression was defined as the absolute difference in AVC score between the baseline and follow-up scan. Logistic and linear regression analyses were performed to evaluate the relationship of Lp(a) with baseline, new onset, and progression of AVC. All analyses were corrected for age, sex, body mass index, smoking, hypertension, dyslipidaemia, and creatinine. AVC progression was analysed conditional on baseline AVC score expressed as restricted cubic splines. Of the 702 individuals without AVC at baseline, 415 (59.1%) developed new-onset AVC on the follow-up scan. In those with baseline AVC, median annual progression was 13.5 (IQR = 5.2–37.8) Agatston units (AU). Lipoprotein(a) concentration was independently associated with baseline AVC [odds ratio (OR) 1.43 for each 50 mg/dL higher Lp(a); 95% confidence interval (CI) 1.15–1.79] and new-onset AVC (OR 1.30 for each 50 mg/dL higher Lp(a); 95% CI 1.02–1.65), but not with AVC progression (β: −71 AU for each 50 mg/dL higher Lp(a); 95% CI −117; 35). Only baseline AVC score was significantly associated with AVC progression (P < 0.001). Conclusion In the population-based Rotterdam Study, Lp(a) is robustly associated with baseline and new-onset AVC but not with AVC progression, suggesting that Lp(a)-lowering interventions may be most effective in pre-calcific stages of aortic valve disease.
Thoracic aortic disease and bicuspid aortic valve (BAV) likely have a heritable component, but large population-based studies are lacking. This study characterizes familial associations of thoracic aortic disease and BAV, as well as cardiovascular and aortic-specific mortality, among relatives of these individuals in a large-population database. In this observational case-control study of the Utah Population Database, we identified probands with a diagnosis of BAV, thoracic aortic aneurysm, or thoracic aortic dissection. Age- and sex-matched controls (10:1 ratio) were identified for each proband. First-degree relatives, second-degree relatives, and first cousins of probands and controls were identified through linked genealogical information. Cox proportional hazard models were used to quantify the familial associations for each diagnosis. We used a competing-risk model to determine the risk of cardiovascular-specific and aortic-specific mortality for relatives of probands. The study population included 3,812,588 unique individuals. Familial hazard risk of a concordant diagnosis was elevated in the following populations compared with controls: first-degree relatives of patients with BAV (hazard ratio [HR], 6.88 [95% CI, 5.62–8.43]); first-degree relatives of patients with thoracic aortic aneurysm (HR, 5.09 [95% CI, 3.80–6.82]); and first-degree relatives of patients with thoracic aortic dissection (HR, 4.15 [95% CI, 3.25–5.31]). In addition, the risk of aortic dissection was higher in first-degree relatives of patients with BAV (HR, 3.63 [95% CI, 2.68–4.91]) and in first-degree relatives of patients with thoracic aneurysm (HR, 3.89 [95% CI, 2.93–5.18]) compared with controls. Dissection risk was highest in first-degree relatives of patients who carried a diagnosis of both BAV and aneurysm (HR, 6.13 [95% CI, 2.82–13.33]). First-degree relatives of patients with BAV, thoracic aneurysm, or aortic dissection had a higher risk of aortic-specific mortality (HR, 2.83 [95% CI, 2.44–3.29]) compared with controls. Our results indicate that BAV and thoracic aortic disease carry a significant familial association for concordant disease and aortic dissection. The pattern of familiality is consistent with a genetic cause of disease. Furthermore, we observed higher risk of aortic-specific mortality in relatives of individuals with these diagnoses. In conclusion, this study provides supportive evidence for screening in relatives of patients with BAV, thoracic aneurysm, or dissection.
Explore the source record for details and available documents.
Photogrammetric measurements of the surface topography of the aortic valves obtained from silicon rubber molds of freshly excised human aortic valves are presented. The data are part of an investigation into the design of a new prosthetic valve which will be a central-flow device, like the real valve and unlike previous central-occluding prostheses. Since the maximum stress on the heart valve is induced when the valve is closed and subject to diastolic back-pressure, it was decided to determine the valve geometry during diastole. That is, the molds were formed by pouring the rubber down the excised aortas, causing the valves to close. The molds were made under different pressures (20-120 torr); photogrammetry served as a vehicle for the assessment of the mold topography through the following outputs: digital models, surface profiles, and contour maps.
An electronic circuit for processing arterial blood pressure waveform signals is described. The circuit detects blood pressure as the heart pumps blood through the aortic valve and the pressure distribution caused by aortic valve closure. From these measurements, timing signals for use in measuring the left ventricular ejection time is determined, and signals are provided for computer monitoring of the cardiovascular system. Illustrations are given of the circuit and pressure waveforms.
Methods for the measurement and display by minicomputer of cardiac images obtained from fluoroscopy to permit an accurate assessment of functional changes are discussed. Heart contours and discrete points can be digitized automatically or manually, with the recorded image in a video, cine, or print format. As each frame is digitized it is assigned a code name identifying the data source, experiment, run, view, and frame, and the images are filed for future reference in any sequence. Two views taken at the same point in the heart cycle are used to compute the spatial position of the ventricle apex and the midpoint of the aortic valve. The remainder of the points on the chamber border are corrected for the linear distortion of the X-rays by projection to a plane containing the chord between the apex and the aortic valve center and oriented so that lines perpendicular to the chord are parallel to the image intensifier face. The image of the chamber surface is obtained by generating circular cross sections with diameters perpendicular to the major chord. The transformed two- and three-dimensional imagery can be displayed in either static or animated form using a graphics terminal.
The cooperative effort towards the development of a tri-leaflet prosthetic heart valve is described. The photogrammetric studies were conducted on silicone rubber molds. Information on data acquisition and data reduction phases is given, and certain accuracy aspects of the project are explained. The various outputs which are discussed include digital models, profiles, and contour maps.
BACKGROUND: For evaluating patients with aortic regurgitation (AR), regurgitant volumes, left ventricular (LV) stroke volumes (SV), and absolute LV volumes are valuable indices. AIM: The aim of this study was to validate the combination of real-time 3-dimensional echocardiography (3DE) and semiautomated digital color Doppler cardiac flow measurement (ACM) for quantifying absolute LV volumes, LVSV, and AR volumes using an animal model of chronic AR and to investigate its clinical applicability. METHODS: In 8 sheep, a total of 26 hemodynamic states were obtained pharmacologically 20 weeks after the aortic valve noncoronary (n = 4) or right coronary (n = 4) leaflet was incised to produce AR. Reference standard LVSV and AR volume were determined using the electromagnetic flow method (EM). Simultaneous epicardial real-time 3DE studies were performed to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV), and LVSV by subtracting LVESV from LVEDV. Simultaneous ACM was performed to obtain LVSV and transmitral flows; AR volume was calculated by subtracting transmitral flow volume from LVSV. In a total of 19 patients with AR, real-time 3DE and ACM were used to obtain LVSVs and these were compared with each other. RESULTS: A strong relationship was found between LVSV derived from EM and those from the real-time 3DE (r = 0.93, P <.001, mean difference (3D - EM) = -1.0 +/- 9.8 mL). A good relationship between LVSV and AR volumes derived from EM and those by ACM was found (r = 0.88, P <.001). A good relationship between LVSV derived from real-time 3DE and that from ACM was observed (r = 0.73, P <.01, mean difference = 2.5 +/- 7.9 mL). In patients, a good relationship between LVSV obtained by real-time 3DE and ACM was found (r = 0.90, P <.001, mean difference = 0.6 +/- 9.8 mL). CONCLUSION: The combination of ACM and real-time 3DE for quantifying LV volumes, LVSV, and AR volumes was validated by the chronic animal study and was shown to be clinically applicable.
Progeria is an ultra-rare (prevalence 1 in 20 million), fatal, pediatric autosomal dominant premature aging disease caused by a mutation in the LMNA gene. This mutation results in accumulation of a high level of an aberrant form of the nuclear membrane protein, Lamin A. This aberrant protein, termed progerin, accumulates in many tissues and is responsible for the diverse array of disease phenotypes. Children die predominantly from premature atherosclerotic cardiovascular disease. The Progeria Research Foundation’s 10th International Scientific Workshop took place via webinar on November 2 and 3, 2020. Participants from 30 countries joined in this new, virtual meeting format. Patient family presentations led the program, followed by updates on Progeria’s first-ever application for FDA drug approval as well as initial results from the only current Progeria clinical trial. This was followed by presentations of unpublished preclinical data on drugs in development targeting the disease-causing DNA mutation, the aberrant mRNA, progerin protein, and its downstream effector proteins. Tying bench to bedside, clinicians presented new discoveries on the natural history of disease to inform future clinical trial development and new Progeria aortic valve replacement procedures. The program engaged the Progeria research community as a single unit with a common goal – to treat and cure children with Progeria worldwide.
Sensor can be installed in left ventricle by means of procedures available for inserting catheter into an artery at body's extremities and manipulating it through vessel and past aortic valve. Metallic tines of device can be used as internal electrode for electrocardiogram.
BACKGROUND: Cardiac papillary fibroelastoma (CPF) is a primary cardiac neoplasm that is increasingly detected by echocardiography. The clinical manifestations of this entity are not well described. METHODS AND RESULTS: In a 16-year period, we identified patients with CPF from our pathology and echocardiography databases. A total of 162 patients had pathologically confirmed CPF. Echocardiography was performed in 141 patients with 158 CPFs, and 48 patients had CPFs that were not visible by echocardiography (<0.2 cm), leaving an echocardiographic subgroup of 93 patients with 110 CPFs. An additional 45 patients with a presumed diagnosis of CPF were identified. The mean age of the patients was 60+/-16 years of age, and 46.1% were male. Echocardiographically, the mean size of the CPFs was 9+/-4.6 mm; 82.7% occurred on valves (aortic more than mitral), 43.6% were mobile, and 91.4% were single. During a follow-up period of 11+/-22 months, 23 of 26 patients with a prospective diagnosis of CPF that was confirmed by pathological examination had symptoms that could be attributable to embolization. In the group of 45 patients with a presumed diagnosis of CPF, 3 patients had symptoms that were likely due to embolization (incidence, 6.6%) during a follow-up period of 552+/-706 days. CONCLUSIONS: CPFs are generally small and single, occur most often on valvular surfaces, and may be mobile, resulting in embolization. Because of the potential for embolic events, symptomatic patients, patients undergoing cardiac surgery for other lesions, and those with highly mobile and large CPFs should be considered for surgical excision.
Most soft tissues possess an oriented architecture of collagen fiber bundles, conferring both anisotropy and nonlinearity to their elastic behavior. Transverse isotropy has often been assumed for a subset of these tissues that have a single macroscopically-identifiable preferred fiber direction. Micro-structural studies, however, suggest that, in some tissues, collagen fibers are approximately normally distributed about a mean preferred fiber direction. Structural constitutive equations that account for this dispersion of fibers have been shown to capture the mechanical complexity of these tissues quite well. Such descriptions, however, are computationally cumbersome for two-dimensional (2D) fiber distributions, let alone for fully three-dimensional (3D) fiber populations. In this paper, we develop a new constitutive law for such tissues, based on a novel invariant theory for dispersed transverse isotropy. The invariant theory is based on a novel closed-form splay invariant that can easily handle 3D fiber populations, and that only requires a single parameter in the 2D case. The model is polyconvex and fits biaxial data for aortic valve tissue as accurately as the standard structural model. Modification of the fiber stress-strain law requires no re-formulation of the constitutive tangent matrix, making the model flexible for different types of soft tissues. Most importantly, the model is computationally expedient in a finite-element analysis.
Introduction A prospective trial of echocardiography was conducted on of six crewmembers onboard the International Space Station. The main objective was to determine the efficacy of remotely guided tele-echocardiography, including just-in-time e-training methods and determine what "space normal" echocardiographic data is. Methods Each crewmember operator (n=6) had 2-hour preflight training. Baseline echocardiographic data were collected 55 to 167days preflight. Similar equipment was used in each 60-minute in-flight session (mean microgravity exposure - 114 days (34 -- 190)). On Orbit ultrasound operators used an e-learning system within 24h of these sessions. Expert assistance was provided using ultrasound video downlink and two-way voice. Testing was repeated 5 to 16 days after landing. Separate ANOVA was used on each echocardiographic variable (n=33). Within each ANOVA, three tests were made: a) effect of mission phase (preflight, in-flight, post flight); b) effect of echo technician (two technicians independently analyzed the data); c) interaction between mission phase and technician. Results Nine rejections of the null hypothesis (mission phase or technician or both had no effect) were discovered and considered for follow up. Of these, six rejections were for significant technician effects, not as a result of space flight. Three rejections of the null hypothesis (Aortic Valve time velocity integral, Mitral E wave Velocity and heart rate) were attributable to space flight, however determined not to be clinically significant. No rejections were due to the interaction between technician and space flight. Conclusion No consistent clinically significant effects of long-duration space flight were seen in echocardiographic variables of the given group of subjects.
The physical principles and current applications of echocardiography in assessment of heart diseases are reviewed. Technical considerations and unresolved points relative to the use of echocardiography in various disease states are stressed. The discussion covers normal mitral valve motion, mitral stenosis, aortic regurgitation, atrial masses, mitral valve prolapse, and idiopathic hypertrophic subaortic stenosis. Other topics concern tricuspic valve abnormalities, aortic valve disease, pulmonic valve, pericardial effusion, intraventricular septal motion, and left ventricular function. The application of echocardiography to congenital heart disease diagnosis is discussed along with promising ultrasonic imaging systems. The utility of echocardiography in quantitative evaluation of cardiac disease is demonstrated.