Search NASA⌕ Search

SEARCH · Search NASA

Results for “apertures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Efficiency of a multilayer-Laue-lens with a 102 μm aperture

A multilayer-Laue-lens (MLL) comprised of WSi 2 /Al layers stacked to a full thickness of 102 microns was characterized for its diffraction efficiency and dynamical diffraction properties by x-ray measurements made in the far field. The achieved aperture roughly doubles the previous maximum reported aperture for an MLL, thereby doubling the working distance. Negative and positive first orders were found to have 14.2 % and 13.0 % efficiencies, respectively. A section thickness of 9.6 μm was determined from Laue-case thickness fringes in the diffraction data. A background gas consisting of 90 % Ar and 10 % N 2 was used for sputtering. This material system was chosen to reduce grown-in stress as the multilayer is deposited. Although some regions of the full MLL exhibited defects, the presently reported results were obtained for a region devoid of defects. The data compare well to dynamical diffraction calculations with Coupled Wave Theory (CWT) which provided confirmation of the optical constants and densities assumed for the CWT calculations.

36 MATERIALS SCIENCE↗

Diffraction properties of multilayer Laue lenses with an aperture of 102 µm and WSi 2 /Al bilayers

We report on the characterization of a multilayer Laue lens (MLL) with large acceptance, made of a novel WSi 2 /Al bilayer system. Fabrication of multilayers with large deposition thickness is required to obtain MLL structures with sufficient apertures capable of accepting the full lateral coherence length of x-rays at typical nanofocusing beamlines. To date, the total deposition thickness has been limited by stress-buildup in the multilayer. We were able to grow WSi2/Al with low grown-in stress, and asses the degree of stress reduction. X-ray diffraction experiments were conducted at beamline 1-BM at the Advanced Photon Source. We used monochromatic x-rays with a photon energy of 12 keV and a bandwidth of $ΔE/\atop {E}$ = 5.4 • 10 -4 . The MLL was grown with parallel layer interfaces, and was designed to have a large focal length of 9.6 mm. The mounted lens was 2.7 mm in width. We found and quantified kinks and bending of sections of the MLL. Sections with bending were found to partly have a systematic progression in the interface angles. We observed kinking in some, but not all, areas. The measurements are compared with dynamic diffraction calculations made with Coupled Wave Theory. Data are plotted showing the diffraction efficiency as a function of the external tilting angle of the entire mounted lens. This way of plotting the data was found to provide an overview into the diffraction properties of the whole lens, and enabled the following layer tilt analyses.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Self characterization of a coded aperture array for neutron source imaging

The neutron imaging system at the National Ignition Facility (NIF) is an important diagnostic tool for measuring the two-dimensional size and shape of the neutrons produced in the burning deuterium-tritium plasma during the stagnation stage of inertial confinement fusion implosions. Since the neutron source is small (∼100 μm) and neutrons are deeply penetrating (>3 cm) in all materials, the apertures used to achieve the desired 10-μm resolution are 20-cm long, triangular tapers machined in gold foils. These gold foils are stacked to form an array of 20 apertures for pinhole imaging and three apertures for penumbral imaging. These apertures must be precisely aligned to accurately place the field of view of each aperture at the design location, or the location of the field of view for each aperture must be measured. In this paper we present a new technique that has been developed for the measurement and characterization of the precise location of each aperture in the array. We present the detailed algorithms used for this characterization and the results of reconstructed sources from inertial confinement fusion implosion experiments at NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of the polar neutron-imaging aperture for use at the National Ignition Facility

The installation of a neutron imaging diagnostic with a polar view at the National Ignition Facility (NIF) required design of a new aperture, an extended pinhole array (PHA). This PHA is different from the pinhole array for the existing equatorial system due to significant changes in the alignment and recording systems. The complex set of component requirements, as well as significant space constraints in its intended location, makes the design of this aperture challenging. In addition, lessons learned from development of prior apertures mandate careful aperture metrology prior to first use. This paper discusses the PHA requirements, constraints, and the final design. The PHA design is complex due to size constraints, machining precision, assembly tolerances, and design requirements. When fully assembled, the aperture is a 15 mm × 15 mm × 200 mm tungsten and gold assembly. The PHA body is made from 2 layers of tungsten and 11 layers of gold. The gold layers include 4 layers containing penumbral openings, 4 layers containing pinholes and 3 spacer layers. In total, there are 64 individual, triangular pinholes with a field of view (FOV) of 200 μm and 6 penumbral apertures. Each pinhole is pointed to a slightly different location in the target plane, making the effective FOV of this PHA a 700 μm square in the target plane. The large FOV of the PHA reduces the alignment requirements both for the PHA and the target, allowing for alignment with a laser tracking system at NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aperture alignment in autocollimator-based deflectometric profilometers

During the last ten years, deflectometric profilometers have become indispensable tools for the precision form measurement of optical surfaces. They have proven to be especially suitable for characterizing beam-shaping optical surfaces for x-ray beamline applications at synchrotrons and free electron lasers. Deflectometric profilometers use surface slope (angle) to assess topography and utilize commercial autocollimators for the contactless slope measurement. To this purpose, the autocollimator beam is deflected by a movable optical square (or pentaprism) towards the surface where a co-moving aperture limits and defines the beam footprint. In this paper, we focus on the precise and reproducible alignment of the aperture relative to the autocollimator's optical axis. Its alignment needs to be maintained while it is scanned across the surface under test. The reproducibility of the autocollimator's measuring conditions during calibration and during its use in the profilometer is of crucial importance to providing precise and traceable angle metrology. In the first part of the paper, we present the aperture alignment procedure developed at the Advanced Light Source, Lawrence Berkeley National Laboratory, USA, for the use of their deflectometric profilometers. In the second part, we investigate the topic further by providing extensive ray tracing simulations and calibrations of a commercial autocollimator performed at the Physikalisch-Technische Bundesanstalt, Germany, for evaluating the effects of the positioning of the aperture on the autocollimator's angle response. The investigations which we performed are crucial for reaching fundamental metrological limits in deflectometric profilometry.

47 OTHER INSTRUMENTATION↗

Proof of Concept Coded Aperture Miniature Mass Spectrometer Using a Cycloidal Sector Mass Analyzer, a Carbon Nanotube (CNT) Field Emission Electron Ionization Source, and an Array Detector

Despite many potential applications, miniature mass spectrometers have had limited adoption in the field due to the tradeoff between throughput and resolution that limits their performance relative to laboratory instruments. Recently, a solution to this tradeoff has been demonstrated by using spatially coded apertures in magnetic sector mass spectrometers, enabling throughput and signal-to-background improvements of greater than an order of magnitude with no loss of resolution. This paper describes a proof of concept demonstration of a cycloidal coded aperture miniature mass spectrometer (C-CAMMS) demonstrating use of spatially coded apertures in a cycloidal sector mass analyzer for the first time. C-CAMMS also incorporates a miniature carbon nanotube (CNT) field emission electron ionization source and a capacitive transimpedance amplifier (CTIA) ion array detector. Results confirm the cycloidal mass analyzer’s compatibility with aperture coding. A >10× increase in throughput was achieved without loss of resolution compared with a single slit instrument. Several areas where additional improvement can be realized are identified. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-contrast imaging with an arbitrary aperture: Active compensation of aperture discontinuities

We present a new method to achieve high-contrast images using segmented and/or on-axis telescopes. Our approach relies on using two sequential deformable mirrors (DMs) to compensate for the large amplitude excursions in the telescope aperture due to secondary support structures and/or segment gaps. In this configuration the parameter landscape of DM surfaces that yield high-contrast point-spread functions is not linear, and nonlinear methods are needed to find the true minimum in the optimization topology. We solve the highly nonlinear Monge-Ampere equation that is the fundamental equation describing the physics of phase-induced amplitude modulation. We determine the optimum configuration for our two sequential DM system and show that high-throughput and high-contrast solutions can be achieved using realistic surface deformations that are accessible using existing technologies. We name this process Active Compensation of Aperture Discontinuities (ACAD). We show that for geometries similar to the James Webb Space Telescope, ACAD can attain at least 10{sup –7} in contrast and an order of magnitude higher for both the future extremely large telescopes and on-axis architectures reminiscent of the Hubble Space Telescope. We show that the converging nonlinear mappings resulting from our DM shapes actually damp near-field diffraction artifacts in the vicinity of the discontinuities. Thus, ACAD actually lowers the chromatic ringing due to diffraction by segment gaps and struts while not amplifying the diffraction at the aperture edges beyond the Fresnel regime. This outer Fresnel ringing can be mitigated by properly designing the optical system. Consequently, ACAD is a true broadband solution to the problem of high-contrast imaging with segmented and/or on-axis apertures. We finally show that once the nonlinear solution is found, fine tuning with linear methods used in wavefront control can be applied to further contrast by another order of magnitude. Generally speaking, the ACAD technique can be used to significantly improve a broad class of telescope designs for a variety of problems.

79 ASTRONOMY AND ASTROPHYSICS↗

Large‐Area, High‐Numerical‐Aperture, Freeform Metasurfaces

Abstract Nanophotonic devices are optical platforms capable of unprecedented wavefront control. To push the limits of experimental device performance, scalable design methodologies that combine the simplicity and fabricability of conventional design paradigms with the extended capabilities of freeform optimization are required. A novel gradient‐based design framework for large‐area freeform metasurfaces is introduced in which nonlocal interactions between simply shaped nanostructures, placed on an irregular lattice, are tailored to produce high‐order hybridized modes that support customizable large‐angle scattering profiles. Utilizing this approach, multifunctional super‐dispersive metalenses are designed and experimentally demonstrated. The approach to high‐numerical‐aperture radial metalenses capable of diffraction limited focusing and the generation of donut‐shaped point spread functions is also extended. It is anticipated that these concepts will have utility in super‐resolution microscopy, particle trapping, additive manufacturing, and metrology applications that require ultra‐high numerical apertures.

Optics↗

Geochemical narrowing of cement fracture aperture during multiphase flow of supercritical CO2 and brine

For carbon capture and storage operations, wells are used as a necessary conduit for injecting CO2 at depth, but they can also act as leakage conduits if the cement seals are compromised. The specific objective of this research was to investigate the nature of self-healing of a fracture within cement under multiphase flow of CO2 and brine, and to compare this to a newly developed model. This was accomplished through a laboratory investigation, flowing reacting supercritical CO2 and brine through a cement fracture with multiphase flow. The influent end of the fracture was degraded as evidenced by the formation of cracks across the surface. At the effluent end of the fracture, the initial aperture of 137 µm was reduced to 50 µm. This reduction by 87 µm was similar to results from a recently developed model tested in this study, which predicted an aperture reduction of 80 µm. Our results demonstrated that the model accurately predicted the reactions which occurred in this multiphase flow system.

wellbore, cement, fracture, multiphase-flow, super↗

A simple technique to reduce evaporation of crystallization droplets by using plate lids with apertures for adding liquids

This article describes the use of evaporation control lids that are fitted to crystallization plates to improve the reproducibility of trials using as little as 5 nl. The plate lids contain apertures which are large enough for the transfer of protein containing droplets, but small enough to greatly reduce the rate of evaporation during the time needed to prepare the plate. A method is described for using plate lids to reduce evaporation in low-volume vapor-diffusion crystallization experiments. The plate lids contain apertures through which the protein and precipitants were added to different crystallization microplates (the reservoir was filled before fitting the lids). Plate lids were designed for each of these commonly used crystallization microplates. This system minimizes the dehydration of crystallization droplets containing just a few nanolitres of protein and precipitant, and results in more reproducible diffraction from the crystals. For each lid design, changes in the weight of the plates were used to deduce the rate of evaporation under different conditions of temperature, air movement, droplet size and precipitant. For comparison, the state of dehydration was also visually assessed throughout the experiment. Finally, X-ray diffraction methods were used to compare the diffraction of protein crystals that were conventionally prepared against those that were prepared on plates with plate lids. The measurements revealed that the plate lids reduced the rate of evaporation by 63–82%. Crystals grown in 5 nl drops that were set up with plate lids diffracted to higher resolution than similar crystals from drops that were set up without plate lids. The results demonstrate that plate lids can be instrumental for improving few-nanolitre crystallizations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effects of Magnetic and Electric Field Uniformity on Coded Aperture Imaging Quality in a Cycloidal Mass Analyzer

Cycloidal mass analyzers are unique sector mass analyzers as they exhibit perfect double focusing, making them ideal for incorporating spatial aperture coding, which can increase the throughput of a mass analyzer without affecting the resolving power. However, the focusing properties of the cycloidal mass analyzer depend on the uniformity of the electric and magnetic fields. In this paper, finite element simulation and charged particle tracing were used to investigate the effect of field uniformity on imaging performance of a cycloidal mass analyzer. For the magnetic field, we evaluate a new permanent magnet geometry by comparing it to a traditional geometry. Results indicate that creating an aperture image in a cycloidal mass spectrometer with the same FWHM as the slit requires less than 1% variation in magnetic field strength along the ion trajectories. The new magnet design, called the opposed dipole magnet, has less than 1% field variation over an area approximately 62 × 65 mm; nearly twice the area available in a traditional design of similar size and weight. This allows ion imaging across larger detector arrays without loss of resolving power. In addition, we compare the aperture imaging quality of a traditionally used cycloidal mass spectrometer electric design with a new optimized design with improved field uniformity. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the First Short Model 150-mm-Aperture Nb3Sn Quadrupole MQXFS for the High-Luminosity LHC Upgrade

LHC Accelerator Research Program (LARP) and CERN combined their efforts in developing Nb3Sn magnets for the high-luminosity LHC upgrade. The ultimate goal of this collaboration is to fabricate large aperture Nb 3Sn quadrupoles for the LHC interaction regions. These magnets will replace the present 70-mm-Aperture NbTi quadrupole triplets for expected increase of the LHC peak luminosity up to 5 × 10 34 cm -2 s -1 or more. Over the past decade, LARP successfully fabricated and tested short and long models of 90 and 120-mm-Aperture Nb3Sn quadrupoles. Recently, the first short model of 150-mm-diameter quadrupole MQXFS was built with coils fabricated both by LARP and CERN. The magnet performance was tested at Fermilab's vertical magnet test facility. Here, this paper reports the test results, including the quench training at 1.9 K, ramp rate and temperature dependence, as well as protection heater studies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Summary of Test Results of MQXFS1—The First Short Model 150 mm Aperture Nb 3 Sn Quadrupole for the High-Luminosity LHC Upgrade

The development of Nb 3 Sn quadrupole magnets for the High-Luminosity LHC upgrade is a joint venture between the US LHC Accelerator Research Program (LARP)* and CERN with the goal of fabricating large aperture quadrupoles for the LHC interaction regions (IR). The inner triplet (low-β) NbTi quadrupoles in the IR will be replaced by the stronger Nb3Sn magnets boosting the LHC program of having 10-fold increase in integrated luminosity after the foreseen upgrades. Previously, LARP conducted successful tests of short and long models with up to 120 mm aperture. The first short 150 mm aperture quadrupole model MQXFS1 was assembled with coils fabricated by both CERN and LARP. The magnet demonstrated a strong performance at Fermilab's vertical magnet test facility reaching the LHC operating limits. This paper presents the latest results from MQXFS1 tests with changed prestress levels. The overall magnet performance, including quench training and memory, ramp rate, and temperature dependence, is also summarized.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Monitoring deformation at the Geysers Geothermal Field, California using C-band and X-band interferometric synthetic aperture radar

In this study, we resolve deformation at The Geysers Geothermal Field using two distinct sets of interferometric synthetic aperture radar (InSAR) data. The first set of observations utilize archived European Space Agency C-band synthetic aperture radar data from 1992 through 1999 to image the long-term and large-scale subsidence at The Geysers. The peak range velocity of approximately 50 mm/year agrees with previous estimates from leveling and global positioning system observations. Data from a second set of measurements, acquired by TerraSAR-X satellites, extend from May 2011 until April 2012 and overlap the C-band data spatially but not temporally. These X-band data, analyzed using a combined permanent and distributed scatterer algorithm, provide a higher density of scatterers (1122 per square kilometer) than do the C-band data (12 per square kilometer). The TerraSAR-X observations resolve 1 to 2 cm of deformation due to water injection into a Northwest Geysers enhanced geothermal system well, initiated on October 2011. Lastly, the temporal variation of the deformation is compatible with estimates from coupled numerical modeling.

58 GEOSCIENCES↗

Subsurface Grain Morphology Reconstruction by Differential Aperture X-ray Microscopy

A multistep, non-destructive grain morphology reconstruction methodology that is applicable to near-surface volumes is developed and tested on synthetic grain structures. This approach probes the subsurface crystal orientation using differential aperture x-ray microscopy on a sparse grid across the microstructure volume of interest. Resulting orientation data are clustered according to proximity in physical and orientation space and used as seed points for an initial Voronoi tessellation to (crudely) approximate the grain morphology. Curvature-driven grain boundary relaxation, simulated by means of the Voronoi implicit interface method, progressively improves the reconstruction accuracy. The similarity between bulk and readily accessible surface reconstruction error provides an objective termination criterion for boundary relaxation.

36 MATERIALS SCIENCE↗