SEARCH · Search NASA
Results for “appearance”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Interplay between appearance and disappearance channels for precision measurements of θ 23 and δ
Not Available
Analysis of the Frequency and Diversity of 1,3-Dialkylimidazolium Ionic Liquids Appearing in the Literature
The hypothetical assertion that there are potentially millions of ionic liquids (ILs) can be validated using basic knowledge of IL precursors and simple calculations. While it is an interesting thought exercise to ponder the possibilities of ILs, it is important to investigate how many discrete ILs (i.e., unique cation and anion pairings) have actually been synthesized and reported in the literature. A complete analysis of all ILs is a daunting task, especially if the definition of what constitutes an IL is broad. Nonetheless, insight can be gained into the use of ILs over the past ~20 years from a focused analysis of systematically varied 1,3-dialkylimidazolium-based ILs (i.e., [R 1 R 2 im][X], where R 1 and R 2 are n-alkyl chains and X is either a halide or molecular anion). This family of ILs includes many of the most widely used and most thoroughly studied IL substances, including 1-butyl-3-methylimidazolium hexafluorophosphate ([C 4 mim][PF 6 ]) and 1-ethyl-3-methylimidazolium bistriflimide ([C 2 mim][Tf 2 N]). Using data retrieved from SciFinder searches, we analyzed the variety and frequency of 1,3-dialkylimidazolium-based ILs appearing in the literature. Our analysis reveals that there is a relatively large number of simple 1,3-dialkylimidazolium cations which have not yet been synthesized. Our findings indicate that despite the broad possibilities of IL structures available, there are but a handful of ILs that are commonly used and studied. Within the 1248 [R 1 R 2 im][X] ILs studied, there were only 12 cations extensively used, which included [R 1 R 2 im] + (R 1 = C 1 and R 2 = C 1 –C 12 ). Of the 16 anions studied, only 5, including [BF 4 ] – , [Cl] – , [PF 6 ] – , [Tf 2 N] – , and [Br] – , were used significantly. Thus, it appears that although ILs can be used as designer solvents with task-specific properties, there is a small default subset of ILs, which are “go-to” or “one-size-fits-all.” Here, we rationalize the current state of the IL landscape in terms of the historical perceptions (and misconceptions) around ILs, familiarity, availability and cost of starting materials, commercial availability of ILs, and the motivations from which researchers choose to synthesize and characterize new ILs.
Correlated, precision measurements of θ 23 and δ using only the electron neutrino appearance experiments
Precision measurement of the leptonic CP violating phase δ will suffer from the, then surviving, large uncertainty of sin 2 θ 23 of 10–20% in the experimentally interesting region near maximal mixing of θ 23 . We advocate a new method for determination of both θ 23 and δ at the same time using only the ν e and ν̄ e appearance channels and show that sin 2 θ 23 can be determined automatically with much higher accuracy, approximately a factor of six, than sinδ. In this method, we identify a new degeneracy for the simultaneous determination of θ 23 and δ, the θ 23 intrinsic degeneracy, which must be resolved in order to achieve precision measurement of these two parameters. Spectral information around the vacuum oscillation maxima is shown to be the best way to resolve this degeneracy.
New constraints on oscillation parameters from {nu}e appearance and {nu}{mu} disappearance in the NOvA experiment
We present updated results from the NOvA experiment for v(mu) -> v(mu) and v(mu) -> v(e) oscillations from an exposure of 8.85 x 10(20) protons on target, which represents an increase of 46% compared to our previous publication. The results utilize significant improvements in both the simulations and analysis of the data. A joint fit to the data for v(mu) disappearance and v(e) appearance gives the best-fit point as normal mass hierarchy, Delta m(32)(2) = 2.44 x 10(-3) eV(2)/c(4), sin(2) theta(23) = 0.56, and delta(CP) = 1.21 pi. The 68.3% confidence intervals in the normal mass hierarchy are Delta m(32)(2) is an element of[2.37, 2.52] x 10(-3) eV(2)/c(4) , sin(2) theta(23) is an element of [0.43; 0.51] boolean OR [0.52; 0.60], and delta(CP) is an element of [0, 0.21 pi] boolean OR [0.91 pi, 2 pi]. The inverted mass hierarchy is disfavored at the 95% confidence level for all choices of the other oscillation parameters.
Correlation between Photooxidation and the Appearance of Raman Scattering Bands in Lead Chalcogenide Quantum Dots
Explore the source record for details and available documents.
Localization-Delocalization Transition of Electrons at the Percolation Threshold of Semiconductor GaAs1-xNx Alloys: The Appearance of a Mobility Edge
No abstract prepared.
Electron Neutrino and Antineutrino Appearance in the Full MINOS Data Sample
Not Available
3D liver segmentation using multiple region appearances and graph cuts
Purpose: Efficient and accurate 3D liver segmentations from contrast-enhanced computed tomography (CT) images play an important role in therapeutic strategies for hepatic diseases. However, inhomogeneous appearances, ambiguous boundaries, and large variance in shape often make it a challenging task. The existence of liver abnormalities poses further difficulty. Despite the significant intensity difference, liver tumors should be segmented as part of the liver. This study aims to address these challenges, especially when the target livers contain subregions with distinct appearances. Methods: The authors propose a novel multiregion-appearance based approach with graph cuts to delineate the liver surface. For livers with multiple subregions, a geodesic distance based appearance selection scheme is introduced to utilize proper appearance constraint for each subregion. A special case of the proposed method, which uses only one appearance constraint to segment the liver, is also presented. The segmentation process is modeled with energy functions incorporating both boundary and region information. Rather than a simple fixed combination, an adaptive balancing weight is introduced and learned from training sets. The proposed method only calls initialization inside the liver surface. No additional constraints from user interaction are utilized. Results: The proposed method was validated on 50 3D CT images from three datasets, i.e., Medical Image Computing and Computer Assisted Intervention (MICCAI) training and testing set, and local dataset. On MICCAI testing set, the proposed method achieved a total score of 83.4 ± 3.1, outperforming nonexpert manual segmentation (average score of 75.0). When applying their method to MICCAI training set and local dataset, it yielded a mean Dice similarity coefficient (DSC) of 97.7% ± 0.5% and 97.5% ± 0.4%, respectively. These results demonstrated the accuracy of the method when applied to different computed tomography (CT) datasets. In addition, user operator variability experiments showed its good reproducibility. Conclusions: A multiregion-appearance based method is proposed and evaluated to segment liver. This approach does not require prior model construction and so eliminates the burdens associated with model construction and matching. The proposed method provides comparable results with state-of-the-art methods. Validation results suggest that it may be suitable for the clinical use.
Appearance versus disappearance of broad absorption line troughs in quasars
ABSTRACT We present a new set of 84 broad absorption line (BAL) quasars (1.7 < zem < 4.4) exhibiting an appearance of C iv BAL troughs over 0.3–4.8 rest-frame years by comparing the Sloan Digital Sky Survey Data Release (SDSSDR)-7, SDSSDR-12, and SDSSDR-14 quasar catalogues. We contrast the nature of BAL variability in this appearing BAL quasar sample with a disappearing BAL quasar sample studied in the literature by comparing the quasar’s intrinsic, BAL trough, and continuum parameters between the two samples. We find that appearing BAL quasars have relatively higher redshift and smaller probed time-scales as compared to the disappearing BAL quasars. To mitigate the effect of any redshift bias, we created control samples of appearing and disappearing BAL quasars that have similar redshift distribution. We find that the appearing BAL quasars are relatively brighter and have shallower and wider BAL troughs compared to the disappearing BAL sample. The distribution of quasar continuum variability parameters between the two samples is clearly separated, with the appearance of the BAL troughs being accompanied by the dimming of the continuum and vice versa. Spectral index variations in the two samples also point to the anticorrelation between the BAL trough and continuum variations consistent with the ‘bluer when brighter’ trend in quasars. We show that the intrinsic dust model is less likely to be a favourable scenario in explaining BAL appearance/disappearance. Our analysis suggests that the extreme variations of BAL troughs like BAL appearance/disappearance are mainly driven by changes in the ionization conditions of the absorbing gas.
Formation mechanism and luminescence appearance of Mn-doped zinc silicate particles synthesized in supercritical water
Luminescence appearance of Mn-doped zinc silicate (Zn{sub 2}SiO{sub 4}:Mn{sup 2+}, ZSM) formed in supercritical water at 400 deg. C and 29 MPa at reaction times from 1 to 4320 min was studied in the relation to its phase formation mechanism. Appearance of luminescent ZSM from green emission by {alpha}-ZSM and yellow emission by {beta}-ZSM occurred over the same time period during the onset of phase formation at a reaction time of 2 min. Luminescence appeared at a much lower temperature and at shorter reaction times than the conventional solid-state reaction. Needle-like-shaped {alpha}-ZSM was the most stable particle shape and phase in the supercritical water reaction environment and particles formed via two routes: a homogenous nucleation route and a heterogenous route that involves solid-state diffusion and recrystallization. - Graphical abstract: Luminescence appearance of Mn-doped zinc silicate (Zn{sub 2}SiO{sub 4}:Mn{sup 2+}, ZSM) formed in supercritical water at 400 deg. C and 29 MPa were studied in the relation to its phase formation mechanism. Green emission by {alpha}-ZSM and yellow emission by {beta}-ZSM occurred over the same time period during the onset of phase formation.
First Results of $\nu_e$ Appearance Analysis and Electron Neutrino Identification at NOvA
NOvA is a long-baseline accelerator-based neutrino oscillation experiment that is optimized for $\nu_\mu\to\nu_e$ measurements. It uses the upgraded NuMI beam from Fermilab and measures electron-neutrino appearance and muon-neutrino disappearance at its Far Detector in Ash River, Minnesota. The $\nu_e$ appearance analysis at NOvA aims to resolve the neutrino mass hierarchy problem and to constrain the CP-violating phase. The first data set of $2.74\times10^{20}$ protons on target (POT) equivalent exposure taken by NOvA has been analyzed. The first measurement of electron-neutrino appearance in NOvA provides solid evidence of $\nu_\mu\to\nu_e$ oscillation with the NuMI beam line. Electron-neutrino identification is the key ingredient for the $\nu_e$ appearance analysis. The electron-identification algorithm used to produce the primary results presented here compares 3-D shower-energy profiles with Monte Carlo prototypes to construct likelihoods for each particle hypothesis. Particle likelihoods, among other event-topology variables, are used as inputs to an Artificial Neural Network for the final electron-neutrino identification. The design and implementation of this algorithm is also presented.
Implicitly solving phase appearance and disappearance problems using two-fluid six-equation model
Phase appearance and disappearance issue presents serious numerical challenges in two-phase flow simulations using the two-fluid six-equation model. Numerical challenges arise from the singular equation system when one phase is absent, as well as from the discontinuity in the solution space when one phase appears or disappears. In this work, a high-resolution spatial discretization scheme on staggered grids and fully implicit methods were applied for the simulation of two-phase flow problems using the two-fluid six-equation model. A Jacobian-free Newton-Krylov (JFNK) method was used to solve the discretized nonlinear problem. An improved numerical treatment was proposed and proved to be effective to handle the numerical challenges. The treatment scheme is conceptually simple, easy to implement, and does not require explicit truncations on solutions, which is essential to conserve mass and energy. Various types of phase appearance and disappearance problems relevant to thermal-hydraulics analysis have been investigated, including a sedimentation problem, an oscillating manometer problem, a non-condensable gas injection problem, a single-phase flow with heat addition problem and a subcooled flow boiling problem. Successful simulations of these problems demonstrate the capability and robustness of the proposed numerical methods and numerical treatments. As a result, volume fraction of the absent phase can be calculated effectively as zero.
Temporal changes in MRI appearance of the prostate after focal ablation
Purpose: The purpose of our study was to retrospectively evaluate and categorize temporal changes in MRI appearances of the prostate in patients who underwent focal therapy with MRI follow-up. Methods: The Institutional Review Board approved this retrospective study and waived the requirement for informed consent. Thirty-seven patients (median age 61; 48–70 years) with low-to-intermediate-risk, clinically organ-confined prostate cancer underwent focal ablation therapy from 2009 to 2014. Two radiologists reviewed post-treatment MRIs (n = 76) and categorized imaging features blinded to the time interval between the focal therapy and the follow-up MRI. Inter-reader agreement was assessed (kappa) and generalized linear regression was used to examine associations between an imaging feature being present/absent and days between ablation and MRI. Results: Inter-reader agreement on MRI features ranged from fair to substantial. Edema was found present at earlier times after ablation (median 16–25 days compared to MRIs without edema, median 252–514 days), as was rim enhancement of the ablation zone (18–22.5 days vs. 409–593 days), a hypointense rim around the ablation zone on T2-weighted images (53-57.5 days vs. 279–409 days) and the presence of an appreciable ablation cavity (48.5–60 days vs. 613–798 days, all p < 0.05). Enhancement of the ablation zone/scar (553–731 days vs. 61.5–162 days) and the formation of a T2-hypointense scar were found to be present on later MRI scans (514–553 days vs. 29–32 days, one reader). Conclusions: The MRI appearance of the prostate after focal ablation changes substantially over time. Identification of temporal patterns in the appearance of imaging features should help reduce image interpretation variability and errors when assessing post-therapeutic scans.
Radiation-Induced Changes in Normal-Appearing White Matter in Patients With Cerebral Tumors: A Diffusion Tensor Imaging Study
Purpose: To quantify the radiation-induced changes in normal-appearing white matter before, during, and after radiotherapy (RT) in cerebral tumor patients. Methods and Materials: Twenty-five patients with low-grade glioma, high-grade glioma, or benign tumor treated with RT were studied using diffusion tensor magnetic resonance imaging. The biologically corrected doses ranged from 50 to 81 Gy. The temporal changes were assessed before, during, and to 45 weeks after the start of RT. The mean diffusivity of water (<D>), fractional anisotropy of diffusion, diffusivity perpendicular ({lambda}{sub perpendicular}) and parallel ({lambda}{sub parallel}) to white matter fibers were calculated in normal-appearing genu and splenium of the corpus callosum. Results: In the genu and splenium, fractional anisotropy decreased and <D>, {lambda}{sub parallel}, {lambda}{sub -perpendicular} increased linearly and significantly with time (p < 0.01). At 45 weeks after the start of RT, {lambda}{sub -perpendicular} had increased {approx}30% in the genu and splenium, and {lambda}{sub parallel} had increased 5% in the genu and 9% in the splenium, suggesting that demyelination is predominant. The increases in {lambda}{sub perpendicular} and {lambda}{sub parallel} were dose dependent, starting at 3 weeks and continuing to 32 weeks from the start of RT. The dose-dependent increase in {lambda}{sub perpendicular} and {lambda}{sub parallel} was not sustained after 32 weeks, indicating the transition from focal to diffuse effects. Conclusion: The acute and subacute changes in normal-appearing white matter fibers indicate radiation-induced demyelination and mild structural degradation of axonal fibers. The structural changes after RT are progressive, with early dose-dependent demyelination and subsequent diffuse dose-independent demyelination and mild axonal degradation. Diffusion tensor magnetic resonance imaging is potentially a biomarker for the assessment of radiation-induced white matter injury.
Magnetic Resonance Imaging Appearances in the Postoperative Breast: The Clinical Target Volume-Tumor and Its Relationship to the Chest Wall
Purpose: To describe and measure the postoperative complexes and their relationship to the chest wall in 100 randomly chosen MRI breast scans, to attempt a better understanding of the changes taking place in the postoperative breast. Methods and Materials: Appearances and measurements of MRI postoperative cavities were analyzed in a cohort of 100 randomly selected patients who underwent a single open MRI scan in the conventional breast radiotherapy treatment position before routine two-dimensional simulation. Results: Magnetic resonance imaging appearances of postoperative cavities seem to differ qualitatively from descriptions of CT and ultrasound cavities in the literature. Rather than being principally homogeneous, heterogeneous cavities were seen in 85%, irregular in 51%. The size of cavity was inversely related to the time elapsed since surgery. Cavities directly touched the chest wall in 53% of cases; 89% lay within 10 mm of the chest wall. Regular, annular concentric rings of differing signal were seen in 32% of cases; such appearances have not been previously described. These patterns suggest that seromas may not shrink entirely as a result of simple serous fluid absorption; instead, new tissue may be being laid down. Because large, regular spheroidal/ellipsoidal cavities with crisp margins may be seromas under pressure, greater target shifts during radiation may need to be anticipated in such cases. Conclusions: Postsurgical cavities in the conserved breast on MRI are commonly heterogeneous, irregular, and lie close to the chest wall. Magnetic resonance imaging studies may help in better understanding the natural history of postoperative cavities.
7-Tesla Susceptibility-Weighted Imaging to Assess the Effects of Radiotherapy on Normal-Appearing Brain in Patients With Glioma
Purpose: To evaluate the intermediate- and long-term imaging manifestations of radiotherapy on normal-appearing brain tissue in patients with treated gliomas using 7T susceptibility-weighted imaging (SWI). Methods and Materials: SWI was performed on 25 patients with stable gliomas on a 7 Tesla magnet. Microbleeds were identified as discrete foci of susceptibility that did not correspond to vessels. The number of microbleeds was counted within and outside of the T2-hyperintense lesion. For 3 patients, radiation dosimetry maps were reconstructed and fused with the 7T SWI data. Results: Multiple foci of susceptibility consistent with microhemorrhages were observed in patients 2 years after chemoradiation. These lesions were not present in patients who were not irradiated. The prevalence of microhemorrhages increased with the time since completion of radiotherapy, and these lesions often extended outside the boundaries of the initial high-dose volume and into the contralateral hemisphere. Conclusions: High-field SWI has potential for visualizing the appearance of microbleeds associated with long-term effects of radiotherapy on brain tissue. The ability to visualize these lesions in normal-appearing brain tissue may be important in further understanding the utility of this treatment in patients with longer survival.