Search NASA⌕ Search

SEARCH · Search NASA

Results for “appliance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Non-Intrusive Appliance Identification with Appliance-Specific Networks

The problem of noninstrusive load monitoring (NILM) is usually formulated as a single-channel blind source separation task, whose successful solution enable fast and convenient load identification and energy disaggregation. When applied at test time, NILM algorithms aim to identify the operating characteristics of individual appliances from an aggregate power measurement of the entire house. Recent advances in deep learning gave rise to many methods that mostly focus on learning a direct mapping from aggregate measurement to individual appliance power. However, these methods are not only computationally expensive, but they often suffer from overfitting and do not generalize very well. In this article, we propose a novel NILM method that leverages advances in statistical learning that have not been properly applied in this domain before. The proposed method consists of three stages: first, a Bayesian nonparametric learning-based approach for appliance state extraction; second, synthetic minority oversampling technique for data augmentation and mitigating the heavy imbalance in switching events; and third, appliance-specific lightweight long short-term memory networks for status classification for each appliance. Here, we adopt a “differential” input (the difference before and after the switching event) to reduce the complexity of network training and make the proposed method robust to multiappliance switching events. Experiments are conducted to demonstrate the effectiveness of the proposed method, achieving superior performance when compared to recent methods. An ablation study is conducted to demonstrate the effectiveness of each module of our method. Finally, we investigate the quality of generated synthetic samples.

42 ENGINEERING↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder

Owing to the increased use of power electronic based appliances and energy-efficient home equipment such as modern lighting loads, the percentage of nonlinear loads has increased in the distribution system, which can impact system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determination of possible interactions at harmonic frequencies, protection planning, and the effect of system impedance. This paper focuses on harmonic load flow analysis for multiple residential load types to determine the expected impacts on an modeled distribution secondary. For this study, the household appliances include lighting, power electronic, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split phase at a nominal frequency of 60 Hz. The harmonic spectrums, as obtained from the experimental evaluation of real loads, are used to inform the harmonic load flow for a detailed secondary network, including the distribution service transformer extracted from a real distribution feeder's model. Additionally, the impact of voltage harmonics on a three-phase test load is presented with experimental results. The harmonic data of the transformer terminal voltage, as obtained from the former load flow study, are scaled to generate the source voltage for the three-phase configuration of the grid simulator to make the test setup very similar to a typical secondary design in the U.S.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 1: Particulate and gaseous emissions

This study investigated how heat demand and fuel loading affect the emissions from outdoor wood-fired hydronic heaters by testing two such appliances using an integrated-duty cycle test method. This test included transient operating conditions, such as cold and hot-starts and modulation between 15 and 100% of maximum rated output. Emission values indicate transient operating conditions produce higher emissions than steady state operation. Cold starts resulted in elevated particulate matter emission factors for both appliances; in one case the particulate matter emission factor for this period was >3500 mg/MJ, which represented emissions 20 times the average value. Additionally, when heat demand was cycled—elevated CO emission factors were measured, with values >5000 mg/MJ for both appliances and more than 3 times the appliance averages, respectively. It follows that the appliance average particulate matter emission factors and CO emission factors were not representative of the actual EF values during these transient periods. In contrast, methane emission factors were relatively stable throughout all tested combustion conditions; however, they were much higher than oil-fired appliances are therefore should not be ignored. These findings demonstrate that wood-fired hydronic heater emissions during transient operating conditions can be significantly greater than emissions during steady-state test conditions, such as those used in typical certification tests. Consequently, certification test values for particulate matter and CO emission factors may significantly underestimate the actual emissions of these appliances when operated in a home. Use of integrated duty-cycle test protocols that capture cold-starts and reloading are better for representing in-use operations of wood-fired hydronic heaters and provide more realistic emissions and delivered efficiency measurements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Load Disaggregation (Modeling Individual Appliance Power Generation & Consumption in Real-Time)

We developed a machine learning-based load disaggregation method to estimate the real-time output of individual appliances from the whole-house measurements. We first learn the important features associated with each type of appliances using the ground truth consumption data of individual appliances potentially available for a small set of houses equipped with submeters. The learned features are then be used to estimate the power generation/consumption of the appliances from the whole-house consumption. This developed load disaggregation software includes two steps. The first step is to identify the on/off status of different appliances using a classification method, and the second step is to estimate the appliance output using a regression method.

Hao, Jun↗

Characterizing electrical demand and load diversity of low-power water and space heating appliances in US homes

Home renovation and remodeling projects can involve costly and time consuming electrical infrastructure upgrades at the household level. From the grid perspective they also lead to costly replacement of local infrastructure, such as transformers, and can add stress to the grid at peak times. The emergence of innovative, power-efficient household appliances offers a way to minimize these problems. These appliances are designed for lower power consumption, simplifying installation through standard plug-in connections, reducing the need for new electric circuits/panels/service, and minimizing the peak power demand for the home. Key examples include low-power heat pump water heaters (HPWHs) and cold climate window heat pumps that operate on standard 120V outlets. To assess the real-world impact of these solutions, we compiled and analyzed power metering data from several US field studies. This data provides insights into the effects on peak power demand of selecting lower-power appliances. Our analysis focuses on several key metrics, including the maximum power demand of individual appliances, their operational runtime, continuous operation and load diversity. While individual low-power 120V space and water heating appliances offer significant peak demand reductions compared to 240V heat pump or resistance alternatives, their longer runtimes might increase the likelihood of operation during whole-dwelling peak events, albeit at lower power levels.

Less, Brennan↗

Consumer Guide to Kitchen Appliances

Learn how reducing energy and water consumption in the kitchen means choosing your new appliances with care and using your existing ones more efficiently. This fact sheet from Energy Saver includes information on ENERGY STAR-qualified appliances, including refrigerators and freezers and dishwashers. Also learn what to look for when shopping for appliances, as well as practices for saving energy and money when using your kitchen appliances.

appliances, ENERGY STAR, EnergyGuide, refrigerator↗

Data-Driven Load Modeling and Forecasting of Residential Appliances

The expansion of residential demand side management programs and increased deployment of controllable loads require accurate appliance-level load modeling and forecasting. This paper proposes a conditional hidden semi-Markov model to describe the probabilistic nature of residential appliance demand. Model parameters are estimated directly from power consumption data using scalable statistical learning methods. We also propose an algorithm for short-term load forecasting as a key application for appliance-level load models. Case studies performed using granular sub-metered power measurements from various types of appliances demonstrate the effectiveness of the proposed load model for short-term prediction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 3: Optical properties of black and brown carbon emissions

Residential biomass combustion is a source of carbonaceous aerosol. Inefficient combustion, particularly of solid fuels produces large quantities of black and brown carbon (BC and BrC). These particle types are important as they have noted effects on climate forcing and human health. One method of measuring these quantities is by measurement of aerosol light-absorption and scattering, which can be performed using an aethalometer and nephelometer, respectively. These instruments are widely deployed in the study of ambient air and are frequently used in air quality modeling and source apportionment studies. In this study, we will describe (1) a method for measuring primary BC and BrC emissions from two residential log-fired wood hydronic heaters and (2) the BC and BrC emission from these devices over a wide range of operating conditions, such as cold-starts, warm-starts, four different levels of output ranging from 15% to 100% maximum rated output, and periods of repeated cycling. The range in flue-gas BC concentrations, measured using an aethalometer at the 880 nanometer (nm) wavelength, were between 5.09 × 10 2 and 2.24 × 10 4 micrograms per cubic meter (µg/m 3 ) while the scattering coefficient of the flue-gas, measured by a nephelometer at 880 nm, ranged between 2.20 × 10 3 and 8.56 × 10 5 inverse megameters (Mm –1 ). The BrC concentrations, measured using the 370 nm wavelength of an aethalometer, were between 9.10 × 10 1 and 3.56 × 10 4 µg/m 3 . The calculated Angstrom Absorption Exponent (AAE) of the flue-gas aerosol ranged between 1.54 and 3.63. Performing a comparison between the measured BC concentration and an external particulate matter (PM) concentration showed that overall BC makes up roughly a quarter of the PM emitted by either of the two appliances. Further for both appliances, the cold-start and the test phase immediately following it had the highest BC and BrC concentrations, the highest measured scattering coefficient, as well as a low AAE.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Additive Manufacturing of Stamping Tools for Appliances

Oak Ridge National Laboratory (ORNL) worked with Whirlpool Corporation to demonstrate additive manufacturing (AM) of stamping dies for the appliance industry using a large-scale wire arc metal additive manufacturing system jointly developed between Lincoln Electric and ORNL. An appliance stamping die was successfully printed, machined, nitrided, and demonstrated in the last quarter of 2019.

42 ENGINEERING↗

Decarbonizing Cooking Appliances With Hydrogen

A novel hydrogen compatible heterogeneous burner prototype was engineered, fabricated, and evaluated for applications in cooking appliances. The key features targeted and accomplished under this effort included fuel flexibility, tolerance to high hydrogen concentrations (up to 85% in atmospheric design and 100% in premixed design), wide range of thermal power ratings, thermal cycling, reliability, and most importantly safety. The burner was operated in the range of 3000 – 12,000 Btu/h under all practical operating conditions (cold start, hot restart, fuel concentration variance). The heterogeneous oxidation burner technology was evaluated for overall performance targeting safety, reliability, emissions, fuel flexibility, and energy efficiency in a commercial RV and residential cooking range appliance prototypes. The burner demonstrated safe and reliable performance generating infrared heating energy without the consumption of any parasitic energy while using low-cost materials. Performance evaluation testing of the novel IR burner demonstrated fuel flexibility with hydrogen blended natural gas while significantly eliminating air pollutants like NOx and methane and increasing the energy efficiency by up to 20%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Defining Power Efficient Residential Electric Appliances and Equipment

While the long-established concept of "energy efficiency" has successfully reduced energy consumption and bills in homes, it is no longer sufficient to address the modern challenges of electrical load growth, infrastructure upgrades and associated affordability challenges. We introduce the concept of “power efficiency” for household appliances and equipment, providing a framework to support affordable home modernization and grid management. Energy efficiency is the measure of energy used (kWh) to provide comfort/conveniences, power efficiency is the measure of power used (kW) to provide those same comforts/conveniences. Energy efficiency was needed because energy is a limited resource and expensive. Now power efficiency is needed because power delivery into a building is a limited resource and expensive. We propose a new set of metrics for defining and measuring power efficiency by investigating how current appliance nameplate ratings are established, and assessing the availability and use of existing data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder: Preprint

This paper focuses on the harmonic load flow study for a set of residential loads and the impacts of the harmonic contents on the distribution feeder. Owing to the increased use of the power electronic based appliances and energy efficient home equipment like the lighting loads, the percentage of non-linear loads has increased in the distribution system which can impact the system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determining possible interactions at harmonic frequencies, protection planning, and the effect of the system impedance. For this study, the household appliances include the lighting, power electronics, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split-phase at a nominal frequency of 60 Hz. The harmonic spectrum as obtained from the experimental data is used to solve the harmonic load flow for a detailed secondary network including the distribution transformer extracted from a real distribution feeder's model. Additionally, the impact of the voltage harmonic on a three phase test load is presented through experimental results. The harmonic data of the transformer terminal voltage as obtained from the former load flow study is scaled to generate the source voltage for the three phase configuration of the grid simulator to make the test setup very similar to a real scenario.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Empirical Assessment of the Appliance-Level Load Shape and Demand Response Potential in India

Over the next 15 years, electricity demand from the key residential and commercial appliances is projected to be nearly 300 GW or ~65% of India’s total peak demand. The objective of this study is to characterize appliance level demand and temporal variation, and identify the overall DR potential in India. We use Bangalore Electricity Supply Company territory (peak load of 3,505 MW in 2016) as a case study, using actual one-minute resolution load data for 2,979 distribution feeders and a detailed load survey. Our results show that agricultural pumping and space cooling (residential, commercial, and industrial) are the main contributors to the peak demand – with shares of 23-27% and 14-23%, respectively. Both sectors have about 1,000 MW of DR potential – agricultural pumps offering load shifting service while space cooling offering shimmy service that is capable of dynamically adjusting to react to short-run ramps and grid disturbances. Residential electric water heaters contribute nearly 18% of the winter morning peak demand and can also offer about 500 MW in shimmy service. Overall, we find that shifting and shimmy services offer 1,199 MW and 1,511 MW total DR potential, respectively.

demand response↗

Managing Army Plug Load Equipment Energy Use: Breakroom Appliances

Breakroom equipment is the third highest energy-consuming plug load category in Army buildings. In addition to the vending machine measures described separately, improved purchasing and control measures for breakroom appliances can save the Army more than 9 million kWh and $550K per year in the building types evaluated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 2: Particle number and size

The use of wood as a fuel for home heating is a concern from an environmental health and safety perspective as biomass combustion appliances emit high concentrations of particulate matter. Wood burning significantly contributes to wintertime particulate matter concentrations in many states in the northern United States. Of particular concern are outdoor wood-fired hydronic heaters. These devices are concerning as they tend to have very large combustion chambers and typical use patterns can result in long periods of low output, which result in an increased particulate matter emission rate relative to high heat output operating conditions. In this study, the performance of two hydronic heaters operating under different combustion conditions, including four different heat output categories approximately corresponding to categories I–IV denoted in Environmental Protection Agency Method 28 Outdoor Wood-fired Hydronic Heaters, and during start-up and reloading events were investigated. Measurements of flue gas particulate number concentration and size for particles with aerodynamic diameters between 0.006 and 10 µm were made using a dilution sampling system. The measured particle number concentration in the flue gas was between 0.71 and 420 million particles per cubic centimeter and was dependent on fuel loading and heat output. For each hydronic heater tested, the highest average particle concentration was found at the beginning of each test during the cold-start condition. Additionally, the majority of the particles had aerodynamic diameters less than 0.100 µm (particles of this size made up between 64% and 97% of all particles) and less than 1% of all particles had aerodynamic diameters greater than 1 µm for all phases. For particles in the accumulation mode, between 0.100 and 1 µm, the mean particle diameter was dependent on fuel loading and heat output.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Hierarchical Control Architecture: Utilization of Behind-the-Meter Appliances with Increased Visibility and Controllability

Optimal operations of distribution systems to enhance reliability and resiliency can be achieved if information with higher fidelity can be accessed from grid premise devices. This paper discusses a hierarchical control architecture that can introduce higher visibility and controllability by utilizing the estimated injection and absorption of different behind-the-meter controllable loads, and DERs, including EVs, within a premise. The acquired information is used to make control decisions for scheduling the premise appliances to reduce energy consumptions. The premise controller can also optimize the consumptions on a day-to-day basis in addition to taking input signals from the utility operators to support grid-service events (e.g., peak shaving). The entire control architecture is designed in a modular and scalable fashion that provides benefits to the utility from the reuse of existing infrastructure while creating opportunities for various grid services to be enabled by the operation of premise controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Voltage stability smart meter for analyzing voltage data and controlling an electrical power source and/or an electric appliance

Systems and methods for voltage stability monitoring and active/reactive power support are disclosed herein. In some embodiments, a smart electric meter of an end user in a grid power system can measure the voltage supplied to the end user via the grid power system, and can analyze the voltage data to detect critical voltage characteristics. The critical voltage characteristics may indicate that a voltage collapse event is likely. The smart electric meter can further estimate a voltage stability margin based on the voltage data. If necessary, the smart electric meter can control an electrical power source and/or an electric appliance positioned at or near the end user to increase the voltage stability margin.

Min, Liang↗