Search NASA⌕ Search

SEARCH · Search NASA

Results for “approach temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

White Paper: Research & Development for the Time at Temperature Approach

Recent advancements in nuclear power research are greatly improving reactor safety and performance through the development of Accident Tolerant Fuel (ATF) and Low-Enriched Uranium Plus (LEU+). These innovations can address Departure from Nucleate Boiling (DNB) margins, which are vital for reactor safety. DNB happens when the coolant switches to film boiling, significantly decreasing heat transfer and posing a risk of fuel cladding failure. The U.S. Nuclear Regulatory Commission (NRC) employs conservative DNB criteria, which can potentially restrict the operational flexibility and efficiency of reactors. The Time at Temperature (TaT) approach could provide a more detailed and adaptable operational guideline by establishing acceptable time-temperature limits, accounting for the duration a material can withstand elevated temperatures without losing its integrity. This method allows reactors to operate more efficiently and safely, offering additional operational margins, faster power adjustments, and improved fuel cycle economics. TaT criteria allow for higher power levels and more flexible responses to operational transients, particularly applicable for anticipated operational occurrences (AOOs) that result in short durations of post-DNB conditions. It enhances plant operational flexibility, allows faster startup times, and enables quicker power level adjustments, optimizing fuel loading patterns and improving fuel cycle economics. Implementing TaT limits reduces core design constraints, lowers fuel usage, and reduces costs, essential for the long-term sustainability of Light Water Reactors (LWRs). TaT maximizes the use of advanced fuel technologies like ATF and LEU+, further enhancing their economic and environmental benefits. To apply the TaT approach in existing LWRs, collaborative research activities among various DOE-sponsored programs are essential. These efforts should incorporate fuel experiments, physics-based high-fidelity modeling, ML-based surrogate modeling, and optimization techniques. This whitepaper proposes four research and development areas: 1) Investigation of the feasibility of new operations of LWR with updated safety limits; 2) Assessment of reactor operation limits through uncertainty reduction; 3) Evaluation of power uprate in virtual environment; and 4) Lattice and reactor core design for power uprate. Each area includes why this research is in need and a suggested scope of work. These comprehensive research areas ensure practical and beneficial advancements for existing reactors, translating innovations in nuclear fuel and cladding technology into improved reactor performance and safety.

42 - ENGINEERING↗

A New Low-Temperature Approach for Efficient and Low-Cost Group V Doping in CdTe Thin Film Solar Cells (Final Technical Report)

The goal of this project is to develop a highly efficient low-temperature ex-situ Group V diffusion doping approach in the CdCl 2 treated polycrystalline CdTe film using the group V chlorides (i.e., PCl 3 , AsCl 3 , SbCl 3 , and BiCl 3 ) as dopants source. For the first time, our innovative doping strategies through the low-temperature ex-situ Group V doping process in polycrystalline CdSeTe successfully demonstrated a promising power conversion efficiency of ~19% compared to the Cu-doped counterparts. Our newly developed low-temperature ex-situ group V doping allows dedicated control of group V diffusion amount, generates a desirable depth profile, and is completely compatible with commercial CdTe module manufacturing. We built the partnership with the largest CdTe solar module manufacturing in the US, e.g., First Solar, Inc to further develop these low-temperature diffusion doped CdSeTe solar cells. Our technology was granted US Patent No. US11257977B2. In this project, we systematically investigate and characterize the new ex-situ group V doping mechanisms, defect chemistry, microstructure, and device physics in CdTe solar cells by combining experimental and theoretical means to pave the way to achieve lower cost toward $\$$0.02/kWh and higher power conversion efficiency (PCE) toward 25% in polycrystalline CdTe solar technology. This project will benefit the public by providing more affordable solar electricity and provide an effective way to address climate change.

14 SOLAR ENERGY↗

Crystal chemistry at high pressure

The chemistry we are taught in school, and we experience in our daily existence occurs at 1 atm. However, pressure spans an astounding 62 orders of magnitude in the Universe in going from the void of interstellar space to the crushing conditions at the center of a neutron star. The way in which pressure affects chemistry is important for Earth and planetary sciences, materials science, in understanding the extreme conditions experienced in nuclear explosions, and it may be key in addressing the future energy needs of our society. In this article we outline how the often neglected pressure variable affects chemistry, beginning from the way in which atomic energy levels are altered. This lays the foundation for understanding the unique crystal and electronic structures that emerge when matter is squeezed, as well as pressure’s effect on chemical reactivity. Finally, we give an overview of the main concepts behind conventional, or phonon-mediated, superconductivity, and describe how the pressure variable may be key in discovering and designing light-element based materials whose superconducting critical temperatures approach room temperature. Here, we discuss some of the main families of superconducting hydrides that have been predicted computationally, and the experimental successes in this exciting and rapidly developing field.

Chemical bonding↗

Prototype energy models for data centers

Data centers in the United States consume about two percent of the nation’s electricity. Because heat gains from IT equipment drive cooling demand, data centers offer unique opportunities for energy savings. However, no prototype energy model for data centers is available in the suite of existing U.S. Department of Energy’s Commercial Prototype Building Models. Here we present the development of two new data center prototype models and their implementation in OpenStudio and EnergyPlus. The small-size data center model represents a computer room in a building served by computer room air conditioners (CRACs); while the large-sized model represents stand-alone data centers served by computer room air handlers (CRAHs) with a central chiller plant. For each data center model, two levels of IT equipment (ITE) load density were considered, to cover the wide range of IT power density of data centers: 40 and 100 W/ft 2 (430 and 1076 W/m 2 ) for the computer room, and 100 and 500 W/ft 2 (1076 and 5382 W/m 2 ) for the stand-alone data center. All other assumptions, such as building envelope, lighting, HVAC efficiencies and schedules, were based on the minimal requirements of ASHRAE Standard 90.1 at various vintages. We introduced a novel concept of supply and return air approach temperatures to capture the essential effects of non-uniform airflow and temperature distribution in data centers. The approach temperatures were pre-computed by computational fluid dynamics (CFD) simulations for various configurations of ITE loads and airflow containment management in data centers. A new feature was developed in EnergyPlus to implement the approach temperature method. A case study was conducted to demonstrate the use of the data center models. The two data center models cover all U.S. climate zones and can be used to evaluate energy saving measures for data centers, as well as to support development of data center energy efficiency codes and standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Plant cover, soil temperature, freeze, water stress, and evapotranspiration conditions

Emissive and reflective data for 10 days, and IR data for 6 nights in south Texas scenes were analyzed after procedures were developed for removing cloud-affected data. HCMM radiometric temperatures were: within 2 C of dewpoint temperatures on nights when air temperature approached dewpoint temperatures; significantly correlated with variables important in evapotranspiration; and, related to freeze severity and planting depth soil temperatures. Vegetation greenness indexes calculated from visible and reflective IR bands of NOAA-6 to -9 meteorological satellites will be useful in the AgRISTARS program for seasonal crop development, crop condition, and drought applications.

Wiegand, C. L.↗

Performance and Cost Potential for Direct-Fired Supercritical CO2 Natural Gas Power Plants

Direct-fired supercritical CO2 (sCO2) power cycles are being explored as an attractive alternative to natural gas combined cycle (NGCC) plants with carbon capture and storage (CCS). Therefore, understanding their performance and cost potential is important for the commercialization of the technology. This study presents the techno-economic optimization results of natural gas-fired, utility-scale power plants based on the direct sCO2 power cycle, which are lacking in public literature. To identify the optimum plant configuration, the study considered multiple cases with varying levels of thermal integration with the plant air separation unit (ASU). Several design variables for each power cycle configuration were identified and optimized to minimize the levelized cost of electricity (LCOE) for each case. The optimization design variables include the sCO2 cooler outlet temperatures, recuperator approach temperatures, and pressure drops. High fidelity models for recuperators, coolers, and turbines were developed and used to capture the impact of design variables on plant efficiency and capital costs. The optimization was conducted using a combination of manual sensitivity analyses and automated derivative-free optimization algorithms available under NETL’s Framework for Optimization and Quantification of Uncertainty and Sensitivity platform. The optimized direct sCO2 power plants offered similar or slightly higher plant efficiencies than the reference NGCC plants based on the F-class gas turbine with CCS. The LCOE of the optimized direct sCO2 plants is 13 to 17% higher than the reference NGCC plants with CCS due to high capital costs associated with the ASU and sCO2 power block, though there is significant room for improvement due to the high uncertainty in component capital costs for these new plants. Recuperators make up over 50% of the sCO2 power block costs. Consequently, any research and development efforts to reduce the recuperator capital costs will benefit the technology’s commercialization. The study also presents preliminary results showing the impact of co-firing landfill gas and natural gas on plant efficiency, LCOE, and CO2 emissions.

Pidaparti, Sandeep↗

Performance and Cost Potential for Direct-Fired Supercritical CO2 Natural Gas Power Plants

Direct-fired supercritical CO2 (sCO2) power cycles are being explored as an attractive alternative to natural gas combined cycle (NGCC) plants with carbon capture and storage (CCS). Therefore, understanding their performance and cost potential is important for the commercialization of the technology. This study presents the techno-economic optimization results of natural gas-fired, utility-scale power plants based on the direct sCO2 power cycle, which are lacking in public literature. To identify the optimum plant configuration, the study considered multiple cases with varying levels of thermal integration with the plant air separation unit (ASU). Several design variables for each power cycle configuration were identified and optimized to minimize the levelized cost of electricity (LCOE) for each case. The optimization design variables include the sCO2 cooler outlet temperatures, recuperator approach temperatures, and pressure drops. High fidelity models for recuperators, coolers, and turbines were developed and used to capture the impact of design variables on plant efficiency and capital costs. The optimization was conducted using a combination of manual sensitivity analyses and automated derivative-free optimization algorithms available under NETL’s Framework for Optimization and Quantification of Uncertainty and Sensitivity platform. The optimized direct sCO2 power plants offered similar or slightly higher plant efficiencies than the reference NGCC plants based on the F-class gas turbine with CCS. The LCOE of the optimized direct sCO2 plants is 13 to 17% higher than the reference NGCC plants with CCS due to high capital costs associated with the ASU and sCO2 power block, though there is significant room for improvement due to the high uncertainty in component capital costs for these new plants. Recuperators make up over 50% of the sCO2 power block costs. Consequently, any research and development efforts to reduce the recuperator capital costs will benefit the technology’s commercialization. The study also presents preliminary results showing the impact of co-firing landfill gas and natural gas on plant efficiency, LCOE, and CO2 emissions.

Pidaparti, Sandeep↗

Development of high temperature liquid lubricants for low-heat rejection: Heavy duty diesel engines

The objective of this DOE program was to develop a liquid lubricant that will allow advanced diesel engines to operate at top ring reversal temperatures approaching 500 C and sump temperatures approaching 250 C. The lubricants developed demonstrated at marginal increase in sump temperature capability, approximately 15 C, and an increase in top ring reversal temperature. A 15W-40 synthetic lubricant designated HTL-4 was the best lubricant developed in terms of stability, wear control, deposit control dispersancy, and particulate emissions.

Wiczynski, P. D.↗

Highly Perfluorinated Covalent Triazine Frameworks Derived from a Low-Temperature Ionothermal Approach Towards Enhanced CO 2 Electroreduction

Perfluorinated covalent triazine frameworks (F-CTFs) have shown unique features and attractive performance in separation and catalysis. However, state-of-art F-CTFs synthesized via the ZnCl 2 -promoted procedure have quite low fluorine contents due to C-F bond cleavage induced by chloride (a Lewis base) and the harsh conditions deployed (400-700 °C). Fabricating F-CTFs with high fluorine contents (> 30 wt%) remains challenging. Herein, we present a low-temperature ionothermal approach (275 °C) to prepare F-CTFs, which is achieved via polymerization of tetrafluoroterephthalonitrile (TFPN) over the Lewis superacids, e.g., zinc triflimide [Zn(NTf 2 ) 2 ] without side reactions. With low catalyst loading (equimolar), F-CTFs are afforded with high fluorine content (31 wt%), surface area up to 367 m 2 g -1 , and micropores around 1.1 nm. The highly hydrophobic F-CTF-1 exhibits good capability to boost electroreduction of CO 2 to CO, with faradaic efficiency of 95.7% at –0.8 V and high current density (–141 mA cm -2 ) surpassing most of the metal-free electrocatalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observation of the Fluctuation Spin Hall Effect in a Low-Resistivity Antiferromagnet

The spin Hall effect (SHE) can generate a pure spin current by an electric current, which is promisingly used to electrically control magnetization. To reduce the power consumption of this control, a giant spin Hall angle (SHA) in the SHE is desired in low-resistivity systems for practical applications. Here, critical spin fluctuation near the antiferromagnetic (AFM) phase transition in chromium (Cr) is proven to be an effective mechanism for creating an additional part of the SHE, named the fluctuation spin Hall effect. Further, the SHA is significantly enhanced when the temperature approaches the Néel temperature (T N ) of Cr and has a peak value of -0.36 near T N . This value is higher than the room-temperature value by 153% and leads to a low normalized power consumption among known spin–orbit torque materials. This study demonstrates the critical spin fluctuation as a prospective way to increase the SHA and enriches the AFM material candidates for spin–orbitronic devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Field orientation dependent magnetic phases in the Weyl semimetal Co 3 ⁢Sn 2 ⁢S 2

Magnetism plays a key role in the emergence of topological phenomena in the Weyl semimetal Co 3 ⁢Sn 2 ⁢S 2 , which exhibits ferromagnetic interactions along the c-axis of the crystal and antiferromagnetic (AFM) interactions within the ab plane. Extensive studies on the temperature dependence of the magnetism with the magnetic field along the c-axis have uncovered a number of magnetic phases. Currently, the nature and origins of the reported magnetic phases are under debate. Here, in this work, we report on magnetic field orientation effects on the magnetism in Co 3 ⁢Sn 2 ⁢S 2 . The shape of the hysteresis loop of the Hall resistance at a fixed temperature is found to change from rectangular to bow tie-like as the magnetic field is tilted from the c-axis toward the ab plane, resembling that reported for magnetic fields along the c-axis as the temperature approaches the Curie temperature from below. Unlike their temperature-dependent counterparts, the newly observed bow tie-like hysteresis loops show exchange bias. Our results showcase the contribution of the in-plane AFM interactions to the magnetism in Co 3 ⁢Sn 2⁢ S 2 and demonstrate a new way to tune its magnetic phases. They also shed light on the temperature-dependent magnetic phases occurring in the magnetic field along the c-axis of the crystal.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An Improved Formulation for Calorimetric Emittance Testing of Spacecraft Thermal Control Coatings

Spacecraft often really heavily on passive thermal control to maintain operating temperature. An important parameter in the spacecraft heat balance equation is the emittance of thermal control coatings as a function of coating temperature. One method for determining the emittance of spacecraft thermal control from elevated temperature to cryogenic temperatures relies on a calorimetric technique. The fundamental equation governing this test method can be found in numerous places in the literature and although it generally provides reasonable results, its formulation is based on a conceptual flaw that only becomes apparent when the sample temperature approaches the wall temperature during testing. This paper investigates the cause for this error and develops the correct formulation for calorimetric emittance testing. Experimental data will also be presented that illustrates the difference between the two formulations and the resulting difference in the calculated emittance.

Kauder, Lonny R.↗

Increasing Main Cooler Thermal Performance for sCO2 Power Cycles

Increasing sCO2 power cycle cooler performance will increase the efficiency and lower the cost of electricity for sCO2 power cycles. This work considered the heat transfer performance of two counter-flow, shell-and-tube heat exchangers using local measurements. The heat exchangers were constructed using commercial tubing. One heat exchanger was constructed with a conventional, smooth inner tube (7 mm nominal inner diameter). The other was constructed with an additively manufactured tube with a square cross section and angled rib turbulators. For mixed mean temperatures away from the pseudocritical temperature, the heat transfer coefficient matched the Dittus-Boelter correlation. As the mixed mean temperature approached the pseudocritical temperature, the heat transfer coefficient deviated from the Dittus-Boelter correlation due to transverse property variation and buoyancy. The local and average heat transfer coefficients for angled rib tubes were nominally 150% to 300% greater than the heat transfer coefficients for the smooth tube. Trends in heat exchanger effectiveness indicated that the ribs were most beneficial when the water flow rates were at the low end of the range considered: 0.016 – 0.126 kg/s. Using results from prior system modeling, it is anticipated that adding heat transfer enhancement features in a cycle cooler will increase the sCO2 cycle efficiency by 0.34 percentage points.

Searle, Matthew↗

Concentrating rare earth elements to phosphate in molten coal ash by a temperature gradient approach

Synthetic coal ash bearing 560 ppm europium oxide, blended with aluminum phosphate, was heat treated above its melting temperature and crystal evolutions with respect to europium concentration under controlled cooling were studied. The sample in a boat crucible was subjected to a temperature gradient of 100 °C across it to cause zone refining effects on crystallization behaviors in the melt (slag). Post analysis found six mineral phases formed from the melt while europium was only present in calcium phosphate, implying the majority of europium was segregated to the calcium phosphate. Europium concentrations in the calcium phosphate phase tended to be higher at zones with higher temperatures: as high as 7200 ppm, a 13-fold increase from the initial concentration.

01 COAL, LIGNITE, AND PEAT↗

Computational fluid dynamic analysis of a novel particle-to-air fluidized-bed heat exchanger for particle-based thermal energy storage applications

Long-duration energy storage technologies are being targeted to enable cost-effective, decarbonized energy systems. Particle-based thermal energy storage systems are one promising technology by storing excess electricity or heat as sensible thermal energy in inexpensive, solid, inert particles. These systems are only possible if an effective and economical particle-to-working fluid heat exchanger exists. This study predicts the performance of a proposed, direct-contact, particle-to-air, pressurized fluidized-bed heat exchanger using computational fluid dynamics. The common Eulerian-Eulerian framework for modeling fluidized beds is first benchmarked to experimental results at a previously untested operating condition and application. Then, the benchmarked model evaluates the performance of a proposed design for a commercial-scale version of the novel particle-to-air heat exchanger. The results show pressure drop and gas-phase approach temperatures are advantageous compared to other proposed designs for particle-to-air heat exchangers in the literature; approach temperatures were less than 5 °C and gas-phase pressure drop across the fluidized bed was 32 kPa. The model also highlights the importance of gas distributor design and representation in the Eulerian-Eulerian framework to control fluidization behavior. In conclusion, the model built and benchmarked in this study can be leveraged to advance the design and analysis of these heat exchangers critical to the deployment of a promising long-duration energy storage technology.

25 ENERGY STORAGE↗