Search NASA⌕ Search

SEARCH · Search NASA

Results for “approach temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Improving AHU Performance by Minimizing Approach Temperature, Reducing Air Maldistribution, and Efficiently Handling Sensible and Latent Loads (Phase 1 Interim Final Technical Report)

Residential air handling units (AHUs) have stayed the same in form and efficiency for the past 30+ years, with incremental improvements made to address safety, functionality, and energy-efficiency. The purpose of this research in Phase I, Topic 9a: Next Generation Residential Air Handlers, was to improve AHU performance by minimizing heat exchanger (HX) approach temperature, reducing air maldistribution, and developing alternative system configurations which more efficiently handle sensible and latent loads. In this research Optimized Thermal Systems (OTS) developed, modeled, and evaluated multiple alternative system concepts. A dual vapor compression system separate sensible and latent cooling (SSLC) concept was studied to inform work on alternative concepts and to show best-case performance benefit. System concepts included ejector enhanced vapor compression cycles, desiccant assisted dehumidification, dual evaporator SSLC, and alternative AHU HX configurations. A dual vapor compression system showed COP improvement of 20%, however, required additional components, increased unit size, and increased cost. Two types of ejector enhanced vapor compression cycles with dual evaporators improved system COP by 9 to 11%, and reduced AHU losses by as much as 18%, with design changes limited to the AHU, no unit physical size increase, and a moderate increase to system first cost. Desiccant assisted air-conditioning required increased air flow rate resulting in higher fan power and the desiccant wheel increased sensible heat load leading to increased compressor power and reduced system COP. Dual evaporator cycles were found to degrade performance due to increased expansion losses. Optimized single slab HX designs used in place of the traditional A-coil HX led to 44–49% reduction in aluminum, 47–60% less refrigerant charge, and improved HX velocity distribution.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

White Paper: Research & Development for the Time at Temperature Approach

Recent advancements in nuclear power research are greatly improving reactor safety and performance through the development of Accident Tolerant Fuel (ATF) and Low-Enriched Uranium Plus (LEU+). These innovations can address Departure from Nucleate Boiling (DNB) margins, which are vital for reactor safety. DNB happens when the coolant switches to film boiling, significantly decreasing heat transfer and posing a risk of fuel cladding failure. The U.S. Nuclear Regulatory Commission (NRC) employs conservative DNB criteria, which can potentially restrict the operational flexibility and efficiency of reactors. The Time at Temperature (TaT) approach could provide a more detailed and adaptable operational guideline by establishing acceptable time-temperature limits, accounting for the duration a material can withstand elevated temperatures without losing its integrity. This method allows reactors to operate more efficiently and safely, offering additional operational margins, faster power adjustments, and improved fuel cycle economics. TaT criteria allow for higher power levels and more flexible responses to operational transients, particularly applicable for anticipated operational occurrences (AOOs) that result in short durations of post-DNB conditions. It enhances plant operational flexibility, allows faster startup times, and enables quicker power level adjustments, optimizing fuel loading patterns and improving fuel cycle economics. Implementing TaT limits reduces core design constraints, lowers fuel usage, and reduces costs, essential for the long-term sustainability of Light Water Reactors (LWRs). TaT maximizes the use of advanced fuel technologies like ATF and LEU+, further enhancing their economic and environmental benefits. To apply the TaT approach in existing LWRs, collaborative research activities among various DOE-sponsored programs are essential. These efforts should incorporate fuel experiments, physics-based high-fidelity modeling, ML-based surrogate modeling, and optimization techniques. This whitepaper proposes four research and development areas: 1) Investigation of the feasibility of new operations of LWR with updated safety limits; 2) Assessment of reactor operation limits through uncertainty reduction; 3) Evaluation of power uprate in virtual environment; and 4) Lattice and reactor core design for power uprate. Each area includes why this research is in need and a suggested scope of work. These comprehensive research areas ensure practical and beneficial advancements for existing reactors, translating innovations in nuclear fuel and cladding technology into improved reactor performance and safety.

42 - ENGINEERING↗

A New Low-Temperature Approach for Efficient and Low-Cost Group V Doping in CdTe Thin Film Solar Cells (Final Technical Report)

The goal of this project is to develop a highly efficient low-temperature ex-situ Group V diffusion doping approach in the CdCl 2 treated polycrystalline CdTe film using the group V chlorides (i.e., PCl 3 , AsCl 3 , SbCl 3 , and BiCl 3 ) as dopants source. For the first time, our innovative doping strategies through the low-temperature ex-situ Group V doping process in polycrystalline CdSeTe successfully demonstrated a promising power conversion efficiency of ~19% compared to the Cu-doped counterparts. Our newly developed low-temperature ex-situ group V doping allows dedicated control of group V diffusion amount, generates a desirable depth profile, and is completely compatible with commercial CdTe module manufacturing. We built the partnership with the largest CdTe solar module manufacturing in the US, e.g., First Solar, Inc to further develop these low-temperature diffusion doped CdSeTe solar cells. Our technology was granted US Patent No. US11257977B2. In this project, we systematically investigate and characterize the new ex-situ group V doping mechanisms, defect chemistry, microstructure, and device physics in CdTe solar cells by combining experimental and theoretical means to pave the way to achieve lower cost toward $\$$0.02/kWh and higher power conversion efficiency (PCE) toward 25% in polycrystalline CdTe solar technology. This project will benefit the public by providing more affordable solar electricity and provide an effective way to address climate change.

14 SOLAR ENERGY↗

Crystal chemistry at high pressure

The chemistry we are taught in school, and we experience in our daily existence occurs at 1 atm. However, pressure spans an astounding 62 orders of magnitude in the Universe in going from the void of interstellar space to the crushing conditions at the center of a neutron star. The way in which pressure affects chemistry is important for Earth and planetary sciences, materials science, in understanding the extreme conditions experienced in nuclear explosions, and it may be key in addressing the future energy needs of our society. In this article we outline how the often neglected pressure variable affects chemistry, beginning from the way in which atomic energy levels are altered. This lays the foundation for understanding the unique crystal and electronic structures that emerge when matter is squeezed, as well as pressure’s effect on chemical reactivity. Finally, we give an overview of the main concepts behind conventional, or phonon-mediated, superconductivity, and describe how the pressure variable may be key in discovering and designing light-element based materials whose superconducting critical temperatures approach room temperature. Here, we discuss some of the main families of superconducting hydrides that have been predicted computationally, and the experimental successes in this exciting and rapidly developing field.

Chemical bonding↗

Prototype energy models for data centers

Data centers in the United States consume about two percent of the nation’s electricity. Because heat gains from IT equipment drive cooling demand, data centers offer unique opportunities for energy savings. However, no prototype energy model for data centers is available in the suite of existing U.S. Department of Energy’s Commercial Prototype Building Models. Here we present the development of two new data center prototype models and their implementation in OpenStudio and EnergyPlus. The small-size data center model represents a computer room in a building served by computer room air conditioners (CRACs); while the large-sized model represents stand-alone data centers served by computer room air handlers (CRAHs) with a central chiller plant. For each data center model, two levels of IT equipment (ITE) load density were considered, to cover the wide range of IT power density of data centers: 40 and 100 W/ft 2 (430 and 1076 W/m 2 ) for the computer room, and 100 and 500 W/ft 2 (1076 and 5382 W/m 2 ) for the stand-alone data center. All other assumptions, such as building envelope, lighting, HVAC efficiencies and schedules, were based on the minimal requirements of ASHRAE Standard 90.1 at various vintages. We introduced a novel concept of supply and return air approach temperatures to capture the essential effects of non-uniform airflow and temperature distribution in data centers. The approach temperatures were pre-computed by computational fluid dynamics (CFD) simulations for various configurations of ITE loads and airflow containment management in data centers. A new feature was developed in EnergyPlus to implement the approach temperature method. A case study was conducted to demonstrate the use of the data center models. The two data center models cover all U.S. climate zones and can be used to evaluate energy saving measures for data centers, as well as to support development of data center energy efficiency codes and standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance and Cost Potential for Direct-Fired Supercritical CO2 Natural Gas Power Plants

Direct-fired supercritical CO2 (sCO2) power cycles are being explored as an attractive alternative to natural gas combined cycle (NGCC) plants with carbon capture and storage (CCS). Therefore, understanding their performance and cost potential is important for the commercialization of the technology. This study presents the techno-economic optimization results of natural gas-fired, utility-scale power plants based on the direct sCO2 power cycle, which are lacking in public literature. To identify the optimum plant configuration, the study considered multiple cases with varying levels of thermal integration with the plant air separation unit (ASU). Several design variables for each power cycle configuration were identified and optimized to minimize the levelized cost of electricity (LCOE) for each case. The optimization design variables include the sCO2 cooler outlet temperatures, recuperator approach temperatures, and pressure drops. High fidelity models for recuperators, coolers, and turbines were developed and used to capture the impact of design variables on plant efficiency and capital costs. The optimization was conducted using a combination of manual sensitivity analyses and automated derivative-free optimization algorithms available under NETL’s Framework for Optimization and Quantification of Uncertainty and Sensitivity platform. The optimized direct sCO2 power plants offered similar or slightly higher plant efficiencies than the reference NGCC plants based on the F-class gas turbine with CCS. The LCOE of the optimized direct sCO2 plants is 13 to 17% higher than the reference NGCC plants with CCS due to high capital costs associated with the ASU and sCO2 power block, though there is significant room for improvement due to the high uncertainty in component capital costs for these new plants. Recuperators make up over 50% of the sCO2 power block costs. Consequently, any research and development efforts to reduce the recuperator capital costs will benefit the technology’s commercialization. The study also presents preliminary results showing the impact of co-firing landfill gas and natural gas on plant efficiency, LCOE, and CO2 emissions.

Pidaparti, Sandeep↗

Performance and Cost Potential for Direct-Fired Supercritical CO2 Natural Gas Power Plants

Direct-fired supercritical CO2 (sCO2) power cycles are being explored as an attractive alternative to natural gas combined cycle (NGCC) plants with carbon capture and storage (CCS). Therefore, understanding their performance and cost potential is important for the commercialization of the technology. This study presents the techno-economic optimization results of natural gas-fired, utility-scale power plants based on the direct sCO2 power cycle, which are lacking in public literature. To identify the optimum plant configuration, the study considered multiple cases with varying levels of thermal integration with the plant air separation unit (ASU). Several design variables for each power cycle configuration were identified and optimized to minimize the levelized cost of electricity (LCOE) for each case. The optimization design variables include the sCO2 cooler outlet temperatures, recuperator approach temperatures, and pressure drops. High fidelity models for recuperators, coolers, and turbines were developed and used to capture the impact of design variables on plant efficiency and capital costs. The optimization was conducted using a combination of manual sensitivity analyses and automated derivative-free optimization algorithms available under NETL’s Framework for Optimization and Quantification of Uncertainty and Sensitivity platform. The optimized direct sCO2 power plants offered similar or slightly higher plant efficiencies than the reference NGCC plants based on the F-class gas turbine with CCS. The LCOE of the optimized direct sCO2 plants is 13 to 17% higher than the reference NGCC plants with CCS due to high capital costs associated with the ASU and sCO2 power block, though there is significant room for improvement due to the high uncertainty in component capital costs for these new plants. Recuperators make up over 50% of the sCO2 power block costs. Consequently, any research and development efforts to reduce the recuperator capital costs will benefit the technology’s commercialization. The study also presents preliminary results showing the impact of co-firing landfill gas and natural gas on plant efficiency, LCOE, and CO2 emissions.

Pidaparti, Sandeep↗

Highly Perfluorinated Covalent Triazine Frameworks Derived from a Low-Temperature Ionothermal Approach Towards Enhanced CO 2 Electroreduction

Perfluorinated covalent triazine frameworks (F-CTFs) have shown unique features and attractive performance in separation and catalysis. However, state-of-art F-CTFs synthesized via the ZnCl 2 -promoted procedure have quite low fluorine contents due to C-F bond cleavage induced by chloride (a Lewis base) and the harsh conditions deployed (400-700 °C). Fabricating F-CTFs with high fluorine contents (> 30 wt%) remains challenging. Herein, we present a low-temperature ionothermal approach (275 °C) to prepare F-CTFs, which is achieved via polymerization of tetrafluoroterephthalonitrile (TFPN) over the Lewis superacids, e.g., zinc triflimide [Zn(NTf 2 ) 2 ] without side reactions. With low catalyst loading (equimolar), F-CTFs are afforded with high fluorine content (31 wt%), surface area up to 367 m 2 g -1 , and micropores around 1.1 nm. The highly hydrophobic F-CTF-1 exhibits good capability to boost electroreduction of CO 2 to CO, with faradaic efficiency of 95.7% at –0.8 V and high current density (–141 mA cm -2 ) surpassing most of the metal-free electrocatalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observation of the Fluctuation Spin Hall Effect in a Low-Resistivity Antiferromagnet

The spin Hall effect (SHE) can generate a pure spin current by an electric current, which is promisingly used to electrically control magnetization. To reduce the power consumption of this control, a giant spin Hall angle (SHA) in the SHE is desired in low-resistivity systems for practical applications. Here, critical spin fluctuation near the antiferromagnetic (AFM) phase transition in chromium (Cr) is proven to be an effective mechanism for creating an additional part of the SHE, named the fluctuation spin Hall effect. Further, the SHA is significantly enhanced when the temperature approaches the Néel temperature (T N ) of Cr and has a peak value of -0.36 near T N . This value is higher than the room-temperature value by 153% and leads to a low normalized power consumption among known spin–orbit torque materials. This study demonstrates the critical spin fluctuation as a prospective way to increase the SHA and enriches the AFM material candidates for spin–orbitronic devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Field orientation dependent magnetic phases in the Weyl semimetal Co 3 ⁢Sn 2 ⁢S 2

Magnetism plays a key role in the emergence of topological phenomena in the Weyl semimetal Co 3 ⁢Sn 2 ⁢S 2 , which exhibits ferromagnetic interactions along the c-axis of the crystal and antiferromagnetic (AFM) interactions within the ab plane. Extensive studies on the temperature dependence of the magnetism with the magnetic field along the c-axis have uncovered a number of magnetic phases. Currently, the nature and origins of the reported magnetic phases are under debate. Here, in this work, we report on magnetic field orientation effects on the magnetism in Co 3 ⁢Sn 2 ⁢S 2 . The shape of the hysteresis loop of the Hall resistance at a fixed temperature is found to change from rectangular to bow tie-like as the magnetic field is tilted from the c-axis toward the ab plane, resembling that reported for magnetic fields along the c-axis as the temperature approaches the Curie temperature from below. Unlike their temperature-dependent counterparts, the newly observed bow tie-like hysteresis loops show exchange bias. Our results showcase the contribution of the in-plane AFM interactions to the magnetism in Co 3 ⁢Sn 2⁢ S 2 and demonstrate a new way to tune its magnetic phases. They also shed light on the temperature-dependent magnetic phases occurring in the magnetic field along the c-axis of the crystal.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Increasing Main Cooler Thermal Performance for sCO2 Power Cycles

Increasing sCO2 power cycle cooler performance will increase the efficiency and lower the cost of electricity for sCO2 power cycles. This work considered the heat transfer performance of two counter-flow, shell-and-tube heat exchangers using local measurements. The heat exchangers were constructed using commercial tubing. One heat exchanger was constructed with a conventional, smooth inner tube (7 mm nominal inner diameter). The other was constructed with an additively manufactured tube with a square cross section and angled rib turbulators. For mixed mean temperatures away from the pseudocritical temperature, the heat transfer coefficient matched the Dittus-Boelter correlation. As the mixed mean temperature approached the pseudocritical temperature, the heat transfer coefficient deviated from the Dittus-Boelter correlation due to transverse property variation and buoyancy. The local and average heat transfer coefficients for angled rib tubes were nominally 150% to 300% greater than the heat transfer coefficients for the smooth tube. Trends in heat exchanger effectiveness indicated that the ribs were most beneficial when the water flow rates were at the low end of the range considered: 0.016 – 0.126 kg/s. Using results from prior system modeling, it is anticipated that adding heat transfer enhancement features in a cycle cooler will increase the sCO2 cycle efficiency by 0.34 percentage points.

Searle, Matthew↗

Concentrating rare earth elements to phosphate in molten coal ash by a temperature gradient approach

Synthetic coal ash bearing 560 ppm europium oxide, blended with aluminum phosphate, was heat treated above its melting temperature and crystal evolutions with respect to europium concentration under controlled cooling were studied. The sample in a boat crucible was subjected to a temperature gradient of 100 °C across it to cause zone refining effects on crystallization behaviors in the melt (slag). Post analysis found six mineral phases formed from the melt while europium was only present in calcium phosphate, implying the majority of europium was segregated to the calcium phosphate. Europium concentrations in the calcium phosphate phase tended to be higher at zones with higher temperatures: as high as 7200 ppm, a 13-fold increase from the initial concentration.

01 COAL, LIGNITE, AND PEAT↗

Computational fluid dynamic analysis of a novel particle-to-air fluidized-bed heat exchanger for particle-based thermal energy storage applications

Long-duration energy storage technologies are being targeted to enable cost-effective, decarbonized energy systems. Particle-based thermal energy storage systems are one promising technology by storing excess electricity or heat as sensible thermal energy in inexpensive, solid, inert particles. These systems are only possible if an effective and economical particle-to-working fluid heat exchanger exists. This study predicts the performance of a proposed, direct-contact, particle-to-air, pressurized fluidized-bed heat exchanger using computational fluid dynamics. The common Eulerian-Eulerian framework for modeling fluidized beds is first benchmarked to experimental results at a previously untested operating condition and application. Then, the benchmarked model evaluates the performance of a proposed design for a commercial-scale version of the novel particle-to-air heat exchanger. The results show pressure drop and gas-phase approach temperatures are advantageous compared to other proposed designs for particle-to-air heat exchangers in the literature; approach temperatures were less than 5 °C and gas-phase pressure drop across the fluidized bed was 32 kPa. The model also highlights the importance of gas distributor design and representation in the Eulerian-Eulerian framework to control fluidization behavior. In conclusion, the model built and benchmarked in this study can be leveraged to advance the design and analysis of these heat exchangers critical to the deployment of a promising long-duration energy storage technology.

25 ENERGY STORAGE↗

Advancing Pumped Thermal Energy Storage Performance and Cost Using Silica Storage Media

Pumped Thermal Energy Storage (PTES) is an electricity storage system that is suitable for long-duration energy storage (10-1000 h) due to its low marginal cost of energy capacity. We present a techno-economic model of a PTES system that uses particle thermal energy storage. Particles have low costs and can be operated over a wide temperature range leading to increased efficiency and reduced costs compared to other PTES designs. We show how the round-trip efficiency, specific power output, capital cost, and levelized cost of storage (LCOS) depend on parameters such as the pressure ratio, heat exchanger approach temperature and pressure loss, and maximum temperature. We compare particle-PTES (P-PTES) performance to PTES which uses liquid thermal energy storage - i.e. molten salt hot storage and methanol cold storage (MS-PTES). We find that using silica particles for storage advances PTES technology: P-PTES can be operated at higher maximum temperatures than MS-PTES. Furthermore, P-PTES can achieve lower approach temperatures in the heat exchangers than MS-PTES without increasing capital costs, because P-PTES uses direct-contact heat transfer in fluidized bed heat exchangers. As a result, we find that P-PTES systems achieve higher round-trip efficiency than MS-PTES (66 % versus 57 %) and lower LCOS (e.g. 0.115 +- 0.03 $/kWhe versus 0.171 +- 0.04 $/kWhe for 10 h discharge). The low cost of particles and containment means that P-PTES can provide long-duration energy storage at low capital cost per unit energy capacity. For example, the total capital cost per unit energy reduces from 245 $/kWhe at 10 h to 38 $/kWhe at 100 h. These costs are considerably lower than MS-PTES (72 $/kWhe at 100 h) and also outcompete current and future Li-ion battery system projections (100-265 $/kWhe).

25 ENERGY STORAGE↗

Defining a compact dry cooler design to reduce LCOE contribution in a CSP facility

Concentrating solar power (CSP), when coupled with a supercritical carbon dioxide (sCO 2 ) power cycle and sensible heat storage, presents a renewable and clean alternative for utility-scale power generation. However, in order to be competitive in the current and future markets, CSP facilities must limit their levelized cost of electricity (LCOE) by minimizing capital costs and reducing operating costs over the lifetime of the plant. Targeting this goal, this study investigates the LCOE impact of the power cycle pre-cooler. This study considers a compact dry cooler with micro-channel technology on the CO 2 side and formed fin geometry on the air side, using directly-coupled centrifugal fans and a transition duct to improve air distribution across the fins as well as protect the fins from contaminants which may cause blockage, soiling, fouling, and damage. In an effort to better understand the dry cooler impact on LCOE, a sensitivity study was conducted using various combinations of end-to-end approach temperatures, air-side pressure drop values, CO 2 -side pressure drop values, fan types, cooler turndown control schemes, cooler module sizes, and design-point ambient temperatures. Furthemore, off-design cycle performance data was calculated for each dry cooler design using NPSS simulation software; cycle performance data were then input to System Advisor Model (SAM) along with the associated capital costs for LCOE prediction of a 100 MW system over a 30 year plant lifetime. Results of this study show the LCOE is most sensitive to air-side performance, followed by heat transfer effectiveness and capital cost. It was found that a power cycle with a mid- to high-performance dry cooler will produce the most competitive power-production costs. Designing at the extreme ends for approach temperature (or effectiveness), design-point ambient temperature, and compactness (footprint) produce higher LCOE values; mid-range values for these parameters balance performance, operating costs, and associated capital cost to optimize LCOE.

14 SOLAR ENERGY↗

Wastewater Recycling Using a Hygroscopic Cooling System

This project by the Energy & Environmental Research Center (EERC), Baltimore Aircoil Company (BAC), and Great River Energy (GRE) evaluated the concept of recycling wastewater at a coal-fired power plant using a hygroscopic cooling system, which is an evaporative cooling technology analogous to conventional cooling towers, except that sparingly soluble dissolved solids are precipitated and removed as waste solids instead of purging them with a liquid blowdown stream. This technology can maximize the use of plant makeup water by obtaining useful evaporative cooling from wastewater while minimizing the volume of wastes needing disposal. Experimental activities were conducted in two phases, a laboratory-based evaluation of the properties of wastewater from the host site, GRE’s Coal Creek Station near Underwood, North Dakota, and a field test of a small pilot hygroscopic cooling system at the host site power plant. Findings from the laboratory study informed the design of the pilot system and the system’s field test performance served as the basis for a techno-economic analysis (TEA) of the hygroscopic recycling concept. At the preferred operating conditions identified during the TEA, the wet-bulb approach temperature of the tower was 7.3°C (13°F) and the volume of blowdown produced by the plant was reduced to 5.4% of its incoming volume. Waste solids produced during field testing were classified as nonhazardous waste based on the measured hazardous element content and evaluation of their leaching potential. However, to qualify as a solid for landfill disposal i.e., as determined by the U.S. Environmental Protection Agency’s paint filter test, it appears that a dewatering step beyond hydrocyclone separation is needed. The baseline levelized cost of wastewater disposal (LCWD) for hygroscopic wastewater recycling was estimated to be $\$ $3.69–$\$ $3.72 per m3 of plant blowdown. Capital cost was estimated to contribute over 54% to the LCWD, and parameters that impact capital cost such as the heat exchange coil material of construction and the tower’s wet-bulb approach temperature were identified as having the greatest impact on overall LCWD. A LCWD estimate prepared for the same application but using thermomechanical brine evaporation was almost 40% higher than that calculated for hygroscopic cooling, despite recovering distilled-quality water for reuse, while the LCWD for disposal-only, deep well injection was estimated to be 30% lower compared to hygroscopic wastewater recycling.

01 COAL, LIGNITE, AND PEAT↗

FINAL TECHNICAL AND ECONOMIC FEASIBILITY STUDY ON THE APPLICATION OF A HEAT INTEGRATED POST-COMBUSTION CO2 CAPTURE SYSTEM WITH HITACHI ADVANCED SOLVENT INTO EXISTING COAL-FIRED POWER PLANT

This report contains the results of a techno-economic assessment (TEA) conducted of a heat integrated post-combustion CO2 capture process with Hitachi advanced solvent for retrofit into an existing coal-fired power plant (but treated as greenfield plant on cost analysis). The process has been developed by the University of Kentucky Center for Applied Energy (UK CAER). EPRI was chiefly responsible for this analysis, with significant input from WorleyParsons, Hitachi Power Systems America (Hitachi) and UK CAER. The project also involves the design, fabrication, installation, testing, and analyses of a slipstream facility located at L&GE-KU’s E.W. Brown Generating Station to demonstrate the UK CAER carbon capture system that could utilize heat integration with the main power plant. The design, start-up, and baseline of the pilot system was performed with a generic 30 wt% MEA solvent to obtain data for direct comparison with the DOE/NETL Reference Case followed by testing Hitachi’s proprietary solvent H3-1. In this techno-economic analysis, two cases utilizing the UK CAER process are compared, using different approach temperatures and solvent, against the DOE/NETL Reference Case (Case 10). The results are shown comparing the energy demand for post-combustion CO2 capture and the net higher heating value (HHV) efficiency of the power plant integrated with the post-combustion capture (PCC) plant. A levelized cost of electricity (LCOE) assessment was performed showing the costs of the options presented in the study. The key factors contributing to the reduction of LCOE were identified as CO2 partial pressure increase at the flue gas inlet, thermal integration of the process, and performance of the Hitachi H3-1 solvent. Recent UK CAER process pilot-scale testing data and process simualtion data showed that the packing heights of absorber and stripper columns were significantly oversized in the prelimanary TEA (Task 2 of this project) and thus updated in this final TEA for the H3-1 case only. In addition, the solvent make-up cost for H3-1 was updated based on lattest test results. Finally, a heat integration with the main power plant was applied in this final TEA to increase overall energy effciency for both the MEA and H3-1 cases. Additonal reductions in capital and operational costs are expected but not taken into account here. Shorter columns result in reduced pressure drops, smaller blower head and pump hydraulic head requirements. An increase in overall energy efficiency resuls in a decreased size of the power plant, the CCS and a reduced parasitic steam requirement to the CCS. The net efficiency of the UK CAER integrated PC power plant with CO2 capture changes from 26.2% for the Reference Case 10 plant in 2010 revised DOE/NETL baseline report to 27.6% for the MEA options considered, and 29.1% for the options utilizing the Hitachi advanced solvent. The UK CAER Process + Hitachi case also produces an extra 30.9 MW of generation compared to the UK CAER Process + MEA case and total 60.9 MW more than DOE Case 10. LCOE ($/MWh) values are $172.08/MWh for the MEA option and $157.65/MWh for the Hitachi H3-1 solvent cases considered in comparison to $189.59/MWh in January 2012 dollar for the Reference Case 10. The UK CAER CCS process with MEA case lowers energy consumption for CO2 capture to 1340 Btu/lb-CO2 captured as compared to 1540 Btu/lb-CO2 in the Reference Case 10. The UK CAER CCS process with H3-1 case further lowers energy consumption for CO2 capture to 973 Btu/lb-CO2 captured, for an advantage of 36.8% less energy consumption than Case 10. The study also shows 38.1% less heat rejection associated with the carbon capture system from 3398 MBtu/hr (Case 10) to 2104 MBtu/hr for the UK CAER + MEA system. Heat rejection is reduced to 2464 MBtu/hr in the UK CAER + H3-1 case, for a 27.5 % decrease compared to Case 10. Modeling outputs show that in the UK CAER process, the cooling water that is 2-5°C cooler than conventional cooling tower water can be achieved for ambient conditions common to the midwest and other regions. The results from the techno-economic assessment show that the proposed technology can be investigated further as a viable alternative to conventional CO2 capture technology. The evaluation also shows the effect of the critical parameters on the LCOE, with the main variables being the approach temperature and CO2 partial pressure increase at the flue gas inlet. A summary of the key advantages of the UK CAER Process + H3-1 case for LCOE and other economic factors compared to the DOE Case 10 is as follows: • A lower variable operating cost by $1.56/MWh ($1.08MWh less than the UK CAER Process + MEA Case), a 11.7% reduction compared to the DOE Case 10 • A lower COE by $25.32MWh ($13.94/MWh lower than the UK CAER Process + MEA Case), a 16.9% reduction compared to the DOE Case 10 • A lower LCOE by $31.94/MWh ($17.51/MWh lower than the UK CAER Process + MEA Case), a 16.9% reduction compared to the DOE Case 10 • A lower cost of CO2 captured by $18.65/tonne CO2 ($9.44/tonne CO2 lower than the UK CAER Process + MEA Case), a 30.4% reduction compared to the DOE Case 10 • A lower cost of CO2 avoided by $34.95/tonne CO2 ($18.53 tonne CO2 lower than the UK CAER Process + MEA Case), a 38.7% reduction compared to the DOE Case 10

Bhown, Abhoyjit S.↗

Quantum bath augmented stochastic nonequilibrium atomistic simulations for molecular heat conduction

Classical molecular dynamics (MD) has been shown to be effective in simulating heat conduction in certain molecular junctions since it inherently takes into account some essential methodological components which are lacking in the quantum Landauer-type transport model, such as many-body full force-field interactions, anharmonicity effects and nonlinear responses for large temperature biases. However, the classical MD reaches its limit in the environments where the quantum effects are significant (e.g. with low-temperatures substrates, presence of extremely high frequency molecular modes). Here, we present an atomistic simulation methodology for molecular heat conduction that incorporates the quantum Bose–Einstein statistics into an “effective temperature” in the form of a modified Langevin equation. We show that the results from such a quasi-classical effective temperature MD method deviates drastically when the baths temperature approaches zero from classical MD simulations and the results converge to the classical ones when the bath approaches the high-temperature limit, which makes the method suitable for full temperature range. In addition, we show that our quasi-classical thermal transport method can be used to model the conducting substrate layout and molecular composition (e.g. anharmonicities, high-frequency modes). Anharmonic models are explicitly simulated via the Morse potential and compared to pure harmonic interactions to show the effects of anharmonicities under quantum colored bath setups. Finally, the chain length dependence of heat conduction is examined for one-dimensional polymer chains placed in between quantum augmented baths.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗