Search NASA⌕ Search

SEARCH · Search NASA

Results for “as-fabricated”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Tensile and compressive stress-strain behavior of heat treated boron-aluminum

An experimental study was conducted to assess the effects of heat treatment and cyclic mechanical loading on the tensile and compressive stress-strain behavior of six boron-aluminum composites having different laminate orientations and being subjected to different heat treatments. The heat treatments were as-fabricated, T6, and T6N consisting of T6 treatment followed by cryogenic quench in liquid nitrogen prior to testing. All laminates were tested in monotonic and cyclic compression, while the tensile-test data are taken from the literature for comparison purposes. It is shown that the linear elastic range of the T6- and T6N-condition specimens is larger than that of the as-fabricated specimens, and that cyclic loading in tension or compression strain hardens the specimens and extends the linear elastic range. For laminates containing 0-deg plies, the stress-strain behavior upon unloading is found to be nonlinear, whereas the other laminates exhibit a linear behavior upon unloading. Specimens in the T6 and T6N conditions show higher strain hardening than the as-fabricated specimens.

Kennedy, J. M.↗

Effects of temperature, thermal exposure, and fatigue on an alumina/aluminum composite

An experimental investigation of the mechanical properties and microstructure of an aluminum matrix/polycrystalline alumina fiber composite material is discussed. The effects of fabrication, isothermal exposure (up to 10,000 hours at 590 K), thermal cycling (6000 cycles between 200 K and 590 K), fatigue (1,000,000 tension-tension cycles) were determined by mechanical testing and metallurgical analysis. The fabrication process severely degraded the fiber strength by reducing the alumina to a nonstoichiometric form and quenching in the resultant vacancies and stress fields. However, isothermal exposure, thermal cycling, and fatigue cycling all restored the fiber strength by enhancing vacancy annihilation. Comparison of the as-fabricated material with other aerospace materials shows that it is an attractive candidate for select applications. Long duration isothermal exposure weakened the matrix by overaging and through the diffusional loss of lithium to a surface reaction forming lithium carbonate. Thermal cycling initiated cracks in the matrix and fibers. Tension-tension fatigue cycling caused no apparent damage to the as-fabricated material but in fact, strengthened it to the rule-of-mixtures value. Fatigue cycling after thermal exposure did have a cumulative damage effect.

Olsen, G. C.↗

Hybrid thermocouple development program

The design and development of a hybrid thermocouple, having a segmented SiGe-PbTe n-leg encapsulated within a hollow cylindrical p-SiGe leg, is described. Hybrid couple efficiency is calculated to be 10% to 15% better than that of a all-SiGe couple. A preliminary design of a planar RTG, employing hybrid couples and a water heat pipe radiator, is described as an example of a possible system application. Hybrid couples, fabricated initially, were characterized by higher than predicted resistance and, in some cases, bond separations. Couples made later in the program, using improved fabrication techniques, exhibited normal resistances, both as-fabricated and after 700 hours of testing. Two flat-plate sections of the reference design thermoelectric converter were fabricated and delivered to NASA Lewis for testing and evaluation.

Garvey, L. P.↗

Test of 50-kw heat-pipe radiator.

A heat pipe radiator consisting of 100 sodium-filled, 1.91-cm OD, stainless steel heat pipes has been tested at temperatures up to 760 C. This radiator was initially designed to have a heat pipe temperature of 740 C with a central coolant channel temperature of 771 C. The as-fabricated radiator heat pipe temperatures varied from 605 C to 700 C when the central coolant channel average temperature was 740 C. The heat pipes operated at 25 C to 110 C lower-than-expected temperatures, resulting in a 43 kW heat rejection capability vs the 50 kW design goal and the 65 kW ultimate capability of the radiator. The 43 kW heat rejection yields a mass/heat rejection ratio of 0.182 kg/kWt which is good for this early state-of-the-art heat pipe radiator. An end-of-mission life specific weight of 0.154 kg/kW is apparently achievable with improvements in radiator fabrication and brazing techniques.

Kikin, G. M.↗

Design, manufacture, development, test, and evaluation of boron/aluminum structural components for space shuttle. Volume 4: Repairability

The repairability of boron/aluminum structural components was investigated. It was demonstrated that metal matrix composite material, damaged in service, can be repaired by techniques that are not very different from those currently in use for conventional materials. A list of repair guidelines was prepared to aid in determining the proper repair techniques for a given structure. The guidelines include specifying types of repair material and their applicability, corrosion prevention procedures, design criteria, and inspection criteria. Boron/aluminum structural components were repaired and tested to compare as-fabricated and repaired performance. All but one set of specimens, when repaired, exceeded the strength of the original specimens.

Miller, M. F.↗

Repair of boron/aluminum composites

A program was performed to determine the repairability of boron/aluminum aerospace structural components. During the program, a list of repair guidelines was prepared to aid in determining the proper repair techniques for a given structure. These guidelines included specifying types of repair material and their applicability, corrosion prevention procedures, design criteria, and inspection criteria. Six sets of boron/aluminum structural components were repaired and tested to compare as-fabricated and repaired performance. The specimens included a honeycomb-stiffened panel, elastically buckled tubes, a skin-stringer panel, a tube combining bending and tension, a splice joint specimen, and a tension field panel. All but one set of specimens, when repaired, exceeded the strength of the original specimens. The repairs resulted in an average weight increase per structure of 9% and an average performance increase of 27%. It is concluded that metal-matrix composite material, damaged in service, can be repaired by techniques not very different from those currently in use for conventional materials.

Christian, J. L.↗

Evaluation of silicon carbide fiber/titanium composites

Izod impact, tensile, and modulus of elasticity were determined for silicon carbide fiber/titanium composites to evaluate their potential usefulness as substitutes for titanium alloys or stainless steel in stiffness critical applications for aircraft turbine engines. Variations in processing conditions and matrix ductility were examined to produce composites having good impact strength in both the as-fabricated condition and after air exposure at elevated temperature. The impact strengths of composites containing 36 volume percent silicon carbide (SiC) fiber in an unalloyed (A-40) titanium matrix were found to be equal to unreinforced titanium-6 aluminum-4 vanadium alloy; the tensile strengths of the composites were marginally better than the unreinforced unalloyed (A-70) matrix at elevated temperature, though not at room temperature. At room temperature the modulus of elasticity of the composites was 48 percent higher than titanium or its alloys and 40 percent higher than that of stainless steel.

Jech, R. W.↗

High temperature dynamic modulus and damping of aluminum and titanium matrix composites

Dynamic modulus and damping capacity property data were measured from 20 to over 500 C for unidirectional B/Al (1100), B/Al (6061), B/SiC/Al (6061), Al2O3/Al, SiC/Ti-6Al-4V, and SiC/Ti composites. The measurements were made under vacuum by the forced vibration of composite bars at free-free flexural resonance near 2000 Hz and at strain application below 0.000001. The damping of B/Al composites was found at all temperatures to be significantly greater than the damping of the Al2O3/Al and SiC/Ti composites, with little variation observed in the dynamic moduli of specimens having almost the same fiber content. It is concluded that on the practical level, the finding of a damping-strength correlation supports the use of composite damping measurements for the nondestructive evaluation of boron fiber strength in as-fabricated and heat-treated B/Al (6061) composites.

Dicarlo, J. A.↗

Feasibility of SiC composite structures for 1644 deg gas turbine seal applications

The feasibility of silicon carbide composite structures was evaluated for 1644 K gas turbine seal applications. The silicon carbide composites evaluated consisted of Si/SiC Silcomp (Trademark) - and sintered silicon carbide as substrates, both with attached surface layers containing BN as an additive. A total of twenty-eight candidates with variations in substrate type and density, and layer chemistry, density, microstructure, and thickness were evaluated for abradability, cold particle erosion resistance, static oxidation resistance, ballistic impact resistance, and fabricability. The BN-free layers with variations in density and pore size were later added for evaluation. The most promising candidates were evaluated for Mach 1.0 gas oxidation/erosion resistance from 1477 K to 1644 K. The as-fabricated rub layers did not perform satisfactorily in the gas oxidation/erosion tests. However, preoxidation was found to be beneficial in improving the hot gas erosion resistance. Overall, the laboratory and rig test evaluations show that material properties are suitable for 1477 K gas turbine seal applications.

Darolia, R.↗

High Temperature Resin Matrix Composites for Aerospace Structures

Accomplishments and the outlook for graphite-polyimide composite structures are briefly outlined. Laminates, skin-stiffened and honeycomb sandwich panels, chopped fiber moldings, and structural components were fabricated with Celion/LARC-160 and Celion/PMR-15 composite materials. Interlaminar shear and flexure strength data obtained on as-fabricated specimens and specimens that were exposed for 125 hours at 589 K indicate that epoxy sized and polyimide sized Celion graphite fibers exhibit essentially the same behavior in a PMR-15 matrix composite. Analyses and tests of graphite-polyimide compression and shear panels indicate that utilization in moderately loaded applications offers the potential for achieving a 30 to 50 percent reduction in structural mass compared to conventional aluminum panels. Data on effects of moisture, temperature, thermal cycling, and shuttle fluids on mechanical properties indicate that both LARC-160 and PMR-15 are suitable matrix materials for a graphite-polyimide aft body flap. No technical road blocks to building a graphite-polyimide composite aft body flap are identified.

Davis, J. G., Jr.↗

Ultra-high modulus organic fiber hybrid composites

An experimental organic fiber, designated Fiber D, was characterized, and its performance as a reinforcement for composites was investigated. The fiber has a modulus of 172 GPa, tensile strength of 3.14 GPa, and density of 1.46 gm/cu cm. Unidirectional Fiber D/epoxy laminates containing 60 percent fiber by volume were evaluated in flexure, shear, and compression, at room temperature and 121 C in both the as fabricated condition and after humidity aging for 14 days at 95 percent RH and 82 C. A modulus of 94.1 GPa, flexure strength of 700 MPa, shear strength of 54 MPa, and compressive strength of 232 MPa were observed at room temperature. The as-fabricated composites at elevated temperature and humidity aged material at room temperature had properties 1 to 20 percent below these values. Combined humidity aging plus evaluated temperature testing resulted in even lower mechanical properties. Hybrid composite laminates of Fiber D with Fiber FP alumina or Thornel 300 graphite fiber were also evaluated and significant increases in modulus, flexure, and compressive strengths were observed.

Champion, A. R.↗

Ultrasonic and mechanical characterizations of fatigue states of graphite epoxy composite laminates

Eight-ply (0, + or - 45, 0)s laminates of Hercules AS/3501-6 graphite epoxy composite are fabricated using various cure pressures ranging from 0.52 to 0.86 MPa and cure temperatures ranging from 150 C to 200 C. In general, the minimum composite void volume fraction is obtained at a cure temperature of 175 C and a cure pressure of 0.86 MPa, or at 200 C and 0.86 MPa. The ultrasonic attenuation at 4 MHz was found to correlate with the composite void volume fraction. Composite specimens were tested in flexural fatigue. Beyond 10,000 fatigue cycles, the ultrasonic attenuation at 4 MHz was found to increase and the flexural stiffness was found to decrease. The ultrasonic attenuation at 4 MHz of the as-fabricated composite can be correlated with the number of fatigue cycles to failure.

Williams, J. H., Jr.↗

Interface control and mechanical property improvements in silicon carbide/titanium composites

Several composite systems made of titanium matrix reinforced with silicon carbide fiber were investigated to obtain a better understanding of composite-degradation mechanisms and to develop techniques to minimize loss of mechanical properties during fabrication and in service. Emphasis was on interface control by fiber or matrix coatings. X-ray diffraction studies on planar samples showed that the formation of titanium silicides was greatly inhibited by the presence of aluminum or Ti3A1 layers at the fiber-matrix interface, with the Ti3A1 being more effective in reducing the reactions. Fiber studies showed that coating the fiber with a 1-micron-thick layer of aluminum improved the as-fabricated strength of a stoichiometric SiC fiber and reduced the fiber degradation during exposure to composite-fabrication conditions. Applying an interfacial barrier by coating the matrix foils instead of the fibers was found to be an effective method for improving composite strength. Reducing the fabrication temperature also resulted in significant improvements in composite strengths. Good-quality, well-consolidated composites were fabricated at temperatures well below those currently used for SiC-Ti composite fabrication.

Brewer, W. D.↗

Work of fracture in aluminum metal-matrix composites

Mechanical tests were conducted on B/Al composites and, for comparison, FP-Al2O3/Al composites in the as-fabricated condition and following high-temperature isothermal exposure or thermal cycling. In B/Al (1100), isothermal exposure at 773 K for 125 hr reduced toughness, measured by the work of fracture, from 76 to 10 kJ/sq m, and a similar reduction was observed after equivalent thermal cycling. In B/Al (6061), the same isothermal exposure reduced toughness from 44.5 to 8 kJ/sq m, but the effect of thermal cycling was less detrimental. In FP-Al2O3/Al, the work of fracture was insensitive to either type of treatment. Experimental results are interpreted in terms of matrix softening, interface properties, and fiber notch sensitivity.

Skinner, A.↗

The effect of diffusion induced lattice stress on the open-circuit voltage in silicon solar cells

It is demonstrated that diffusion induced stresses in low resistivity silicon solar cells can significantly reduce both the open-circuit voltage and collection efficiency. The degradation mechanism involves stress induced changes in both the minority carrier mobility and the diffusion length. Thermal recovery characteristics indicate that the stresses are relieved at higher temperatures by divacancy flow (silicon self diffusion). The level of residual stress in as-fabricated cells was found to be negligible in the cells tested.

Weizer, V. G.↗

Thermal degradation of the tensile properties of undirectionally reinforced FP-Al2O3/EZ 33 magnesium composites

The effects of isothermal and cyclic exposure on the room temperature axial and transverse tensile strength and dynamic flexural modulus of 35 volume percent and 55 volume percent FP-Al203/EZ 33 magnesium composites were studied. The composite specimens were continuously heated in a sand bath maintained at 350 C for up to 150 hours or thermally cycled between 50 and 250 C or 50 and 350 C for up to 3000 cycles. Each thermal cycle lasted for a total of six minutes with a hold time of two minutes at the maximum temperature. Results indicate no significant loss in the room temperature axial tensile strength and dynamic flexural modulus of composites thermally cycled between 50 and 250 C or of composites isothermally heated at 350 C for up to 150 hours from the strength and modulus data for the untreated, as-fabricated composites. In contrast, thermal cycling between 50 and 350 C caused considerable loss in both room temperature strength and modulus. Fractographic analysis and measurement of composite transverse strength and matrix hardness of thermally cycled and isothermally heated composites indicated matrix softening and fiber/matrix debonding due to void growth at the interface and matrix cracking as the likely causes of the strength and modulus loss behavior. Previously announced in STAR as N82-21260

Bhatt, R.T.↗

The effect of diffusion induced lattice stress on the open-circuit voltage in silicon solar cells

It is demonstrated that diffusion induced stresses in low resistivity silicon solar cells can significantly reduce both the open-circuit voltage and collection efficiency. The degradation mechanism involves stress induced changes in both the minority carrier mobility and the diffusion length. Thermal recovery characteristics indicate that the stresses are relieved at higher temperatures by divacancy flow (silicon self diffusion). The level of residual stress in as-fabricated cells was found to be negligible in the cells tested.

Weizer, V. G.↗

Effects of thermal cycling on graphie-fiber-reinforced 6061 aluminum

Graphite-reinforced aluminum alloy metal-matrix composites are among materials being considered for structural components in dimensionally stable space structures. This application requires materials with low values of thermal expansions and high specific stiffnesses. They must remain stable during exposures to the space environment for periods extending to 20 years. The effects of thermal cycling on the thermal expansion behavior and mechanical properties of Thornel P100 graphite 6061 aluminum composites, as fabricated and after thermal processing to eliminate thermal strain hysteresis, have been investigated. Two groups of composites were studied: one was fabricated by hot roll bonding and the other by diffusion bonding. Processing significantly reduced strain hysteresis during thermal cycling in both groups and improved the ultimate tensile strength and modulus in the diffusion-bonded composites. Thermal cycling stabilized the as-fabricated composites by reducing the residual fabrication stress and increased the matrix strength by metallurgical aging. Thermal expansion behavior of both groups after processing was insensitive to thermal cycling. Data scatter was too large to determine effects of thermal cycling on the mechanical properties. The primary effects of processing and thermal cycling can be attributed to changes in the metallurgical condition and stress state of the matrix.

Dries, G. A.↗