Assesment of the 3 H(n,2n) Reaction for NIF-relevant Simulations
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Explore the source record for details and available documents.
The Department of Energy (DOE) awarded George Mason University (GMU) with a research project. This project started on June, 2009 and ended July 2014. Main objectives of this research project are; a) to assess the indirect and semi-direct aerosol effects on microphysical structure and radiative properties of Arctic clouds, b) to assess the impact of feedback between the aerosol-cloud interactions and atmospheric boundary layer (ABL) processes on the surface energy balance, c) to better understand and characterize the important unresolved microphysical processes, aerosol effects, and ABL processes and feedbacks, over meso-γ spatial (~1-2 km) and temporal scales (a few minutes to days), and d) to investigate the scale dependency of microphysical parameterizations and its effect on simulations.
The ECP/VTK-m project is providing the core capabilities to perform scientific visualization on exascale architectures. The ECP/VTK-m project fills the critical feature gap of performing visualization and analysis on processors like graphics-based processors and many integrated core. The results of this project will be delivered in tools like Para View, Vislt, and Ascent as well as in stand-alone form. Moreover, these projects are depending on this ECP effort to be able to make effective use of ECP architectures.
The ECP/VTK-m project is providing the core capabilities to perform scientific visualization on Exascale architectures. The ECP/VTK-m project fills the critical feature gap of performing visualization and analysis on processors like graphics-based processors and many integrated core. The results of this project will be delivered in tools like ParaView, Vislt, and Ascent as well as in stand-alone form. Moreover, these projects are depending on this ECP effort to be able to make effective use of ECP architectures.
The DOE Meteorological Coordinating Council (DMCC) conducted an initial LANL Meteorological (Met) Program Assist Visit in August 2006 (DMCC 2006). A follow-up assist visit in August 2015 assessed progress (DMCC 2015), and in June 2023, the DOE Meteorological Subcommittee (DMSC), successor to the DMCC, conducted a second follow-up assist visit (DMSC 2023), in which the Met Program was evaluated relative to the following 8 high-level questions.
The key issues in all areas of Differential Absorption Lidar (DIAL) data collection and analysis techniques were examined. This included consideration of the practical and theoretical limitations of DIAL and the range of possible DIAL measurements.
The human exploration of Mars will impose unavoidable health risks from galactic cosmic rays (GCR) and possibly solar particle events (SPE). It is the goal of NASA's Space Radiation Health Program to develop the capability to predict health risks with significant accuracy to ensure that risks are well below acceptable levels and to allow for mitigation approaches to be effective at reasonable costs. End-to-End risk assessment is the approach being followed to understand proton and heavy ion damage at the molecular, cellular, and tissue levels in order to predict the probability of the major health risk including cancer, neurological disorders, hereditary effects, cataracts, and acute radiation sickness and to develop countermeasures for mitigating risks.
Explore the source record for details and available documents.
It was attempted to assess the reliability of DRAMs at the package level.
The space environment presents many hazards for satellites and spacecraft. One of the major hazards is hypervelocity impacts from uncontrolled man-made space debris. Arnold Engineering Development Complex (AEDC), The National Aeronautics and Space Administration (NASA), The United States Air Force Space and Missile Systems Center (SMC), the University of Florida, and The Aerospace Corporation configured a large ballistic range to perform a series of hypervelocity destructive impact tests in order to better understand the effects of space collisions. The test utilized AEDC's Range G light gas launcher, which is capable of firing projectiles up to 7 km/s. A non-functional full-scale representation of a modern satellite called the DebriSat was destroyed in the enclosed range enviroment. Several modifications to the range facility were made to ensure quality data was obtained from the impact events. The facility modifcations were intended to provide a high impact energy to target mass ratio (>200 J/g), a non-damaging method of debris collection, and an instrumentation suite capable of providing information on the physics of the entire imapct event.
A series of wind tunnel tests were conducted at the NASA Langley Research Center Transonic Dynamics Tunnel to assess the transonic buffet environment for the Space Launch System (SLS) launch vehicle. An initial test, conducted in 2012, indicated an elevated buffet environment prompting a second test to provide further insight into the buffet phenomena and assess potential solutions to reduce the response levels of these environments. During the course of the test program, eight variants of the SLS-10000 configuration were examined. The effect of these configuration variants on the coefficient of the root-mean-square fluctuation of pressure about the mean as a function of test condition indicates that the maximum fluctuating pressure levels are extremely sensitive to the geometry of the forward attachment of the solid rocket boosters (SRBs) to the SLS Core. The addition of flow fences or changes to the SRB nose cone geometry can alleviate the unsteady pressure environment.
Topics treated in this presentation include continuous mold line technologies and linearizing non-linear models in support of airworthiness assessments.
The Adaptive Compliant Trailing Edge (ACTE) demonstrator is a joint task under the National Aeronautics and Space Administration Environmentally Responsible Aviation Project in partnership with the Air Force Research Laboratory and FlexSys, Inc. (Ann Arbor, Michigan). The project goal is to develop advanced technologies that enable environmentally friendly aircraft, such as adaptive compliant technologies. The ACTE demonstrator flight-test program encompassed replacing the Fowler flaps on the SubsoniC Aircraft Testbed, a modified Gulfstream III (Gulfstream Aerospace, Savannah, Georgia) aircraft, with control surfaces developed by FlexSys. The control surfaces developed by FlexSys are a pair of uniquely-designed unconventional flaps to be used as lifting surfaces during flight-testing to validate their structural effectiveness. The unconventional flaps required a multidisciplinary airworthiness assessment to prove they could withstand the prescribed flight envelope. Several challenges were posed due to the large deflections experienced by the structure, requiring non-linear analysis methods. The aeroelastic assessment necessitated both conventional and extensive testing and analysis methods. A series of ground vibration tests (GVTs) were conducted to provide modal characteristics to validate and update finite element models (FEMs) used for the flutter analyses for a subset of the various flight configurations. Numerous FEMs were developed using data from FlexSys and the ground tests. The flap FEMs were then attached to the aircraft model to generate a combined FEM that could be analyzed for aeroelastic instabilities. The aeroelastic analysis results showed the combined system of aircraft and flaps were predicted to have the required flutter margin to successfully demonstrate the adaptive compliant technology. This paper documents the details of the aeroelastic airworthiness assessment described, including the ground testing and analyses, and subsequent flight-testing performed on the unconventional ACTE flaps.
As NASA and other space agencies prepare for future long-term space missions beyond the LEO, the cumulative impact of risk factors encountered in space increases substantially rising concerns about astronauts health. Application of on-board medications to mitigate clinical symptoms associated with certain medical conditions and illnesses is the first line of response to ensure sustainable health and performance of crew. Unfortunately, very limited research has been conducted to determine efficacy of the earth-based pharmaceuticals in a microgravity environment. In some instances, orally administered medications taken during flight were reported to be less effective than expected. Evaluation of series of experiments involving astronauts from shuttle flights shows notable individual variability to several pharmaceuticals during flight. These data provide reasonable assumption of perturbation in CYP450 enzymes during spaceflight, which contribute to the hepatic metabolism of the majority of drugs and therefore may have significant effects on therapeutic efficacy and increase treatment-related toxicity. The genes encoding the CYP450 enzymes are highly variable in humans. Inheritable variations of CYP450 hepatic metabolizer enzymes and transport proteins play a crucial role in the inter-individual variability of drug efficiency and risks of adverse drug reactions. Additionally, there are some reports that document changes in the levels of production of drug-metabolizing enzymes in microgravity. Therefore, in order to provide a safe and effective pharmaceutical treatment in space, medications selection should be based not only on the specific efficacy of medications but also on the individual drug sensitivity and flight-induced changes in metabolism of astronauts chosen for a particular mission. To our knowledge, there was no pre-flight drug sensitivity testing on a genetic level for any of the previous manned NASA space missions. Therefore, technologies capable of predicting and managing medication efficacy, side effects, and toxicity of drugs based on individual genetic variability of crew members are increasingly needed. In this report, we present results of testing the market available Personalized Prescribing System (PPS), a comprehensive, non-invasive solution for safer, targeted medication management for every crew member. Statistical accuracy and simplicity of non-invasive sample analysis demonstrate the feasibility of drug sensitivity assessment and record-keeping tool for flight surgeons and astronauts in applying the recommended medications for situations arising in flight. The information on individual drug sensitivity will translate into personalized risk assessment for adverse drug reactions and treatment failures for each drug from the medication kit as well as predefined outcome. This will address the HHC’s raised “Concern of Clinically Relevant Unpredicted Effects of Medication” as recently updated.
Verification and validation results of the SCALE 6.2 lattice physics codes TRITON/NEWT and Polaris are presented. The SCALE/KENO continuous energy Monte-Carlo code is used as a reference to compare results of more than 2,000 combinations of pressurized water reactor and boiling water reactor lattice designs and state points. Radiochemical assay measurements were also used to assess the accuracy of depletion calculations. Results show that Polaris and TRITON/NEWT using ENDF/B_VII.1 produce accurate lattice physics calculations and cross section data for core simulators.
In the transmutation process, minor actinides such as neptunium, americium and curium obtained from spent nuclear fuel are incorporated into new fuel that can be placed into a fast reactor, where these elements fission into products with shorter half-lives which reduces the health and safety hazards [1]. In order to better understand the all the involved processes, fundamental physical properties of actinides should be investigated, and for that reason, high-purity materials need to be produced. One of the main challenges in characterizing these materials is the lack of pure metal available for study, and lack of analytical methods to determine the purity. Trans-uranic elements are challenging to study because of the need to be handled in specialized facilities, safeguards concerns and they are not easily purchased and/or produced. High-purity Np metal is being produced at the Materials and Fuels Complex (MFC) of Idaho National Laboratory (INL), in a process of direct oxide reduction developed by Squires and Lessing [2], with a target purity of 99.999%. The goal of this research is to develop methods to determine the impurities in the Np metal, with detection limits low enough to achieve this purity level. In this work, we have used several ICP-MS and ICP OES techniques, but the focus was the method development using a recently acquired Double-Focusing Sector Field Inductively Coupled Plasma Mass Spectrometer (SF-ICP-MS). To produce the Np metal, approximately 20 g of the neptunium oxide powder was calcined at 800 oC for 6 h in a magnesium oxide crucible, which is placed inside a stainless steel crucible, that goes into the Hot Uniaxial Press (HUP) furnace insert. After the calcining step, the Np oxide was mixed with approximately 9 g of calcium metal and 100 g of ultra-dry calcium chloride. The HUP furnace was heated in a ramp rate of 50 oC min -1 up to 1000 oC. When the reaction mixture reached 850 oC, a tantalum stirrer was activated at 100 rpm. After the tantalum stirrer was removed and the mixture cooled overnight, the MgO crucible was opened with a hammer and chisel to retrieve the Np metal button at the bottom of the reaction mixture [2]. Prior to the dissolution process, the surface contaminants of the sample were removed. The Np button was washed in 10 mL of ultra-pure water for 1 min, with a faint reaction observed on the surface, indicating the presence of Ca metal. The water-washed sample was placed in a tube with 2 M HCl for only 3 s, as a vigorous reaction in the button surface was observed. The leachates were saved for further analysis. The sample was then rinsed with ultra-pure water and air-dried prior to dissolution. The cleaned sample was placed in a PTFE beaker and 25 mL of 6 M HCl and 150 µL of 24 M HF were added. After 10 minutes of reaction, the beaker was placed on a hot plate for 1 h and 30 min, followed by the addition of 1 mL of 16 M HNO3 and allowed to react for a further 1 h and 20 min. The sample was removed from heat and 10 mL of HNO3 16 M was added to react with the HCl. The beaker was covered and left for overnight reaction, producing a solution with approximately 20 mL of final volume. A Quadrupole Inductively Coupled Plasma Mass Spectrometer (Q-ICP-MS, Perkin Elmer ELAN DRC II Q-ICP-MS) was used to obtain qualitative mass spectra for the dissolution blank, each of the leachates and the dissolved sample. In the water leachate spectrum mainly Ca and Mg were observed, while the acid wash had a similar peak pattern to the one observed for the Np metal sample, indicating that the process not only removed surface contamination, but also reacted with the sample itself. In the Np material spectrum, Ta and actinides were identified as candidates for major contaminants, as the most intense peaks corresponded to the mass-to-charge ratios of these elements. Minor contaminants included Al, Au, Ca, Cr, Fe, I, Na, Nb, Pb, Sn, Ti, Tl, V, Y. The presence of impurities in the material could have originated from several sources, such as the materials used for the casting process, the use of impure NpO2 or contamination of reagents and materials used for the analysis. Some of the isotopes listed as potential contaminants are susceptible to spectral interferences, so Double-Focusing SF-ICP-MS (Nu Instruments Attom ES HR-ICP-MS) was used for the quantitative analysis. For each isotope determined, several items were evaluated: raw signal of a blank solution, sensitivity and determination coefficient of calibration curves, possibility of interferences and comparison of results obtained for at least two resolving powers (RP): 300 and 4000. The evaluation of the signal in a blank solution can indicate if a spectral interference from the plasma gas and/or the solvent was successfully resolved (commonly observed for 52Cr+/40Ar12C+, for example). It is important to highlight that a signal reduction is expected when a higher RP is used, as the ion beam transmission is decreased by the use of na