Search NASA⌕ Search

SEARCH · Search NASA

Results for “astigmatism”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Improved astigmatic focus error detection method

All easy-to-implement focus- and track-error detection methods presently used in magneto-optical (MO) disk drives using pre-grooved media suffer from a side effect known as feedthrough. Feedthrough is the unwanted focus error signal (FES) produced when the optical head is seeking a new track, and light refracted from the pre-grooved disk produces an erroneous FES. Some focus and track-error detection methods are more resistant to feedthrough, but tend to be complicated and/or difficult to keep in alignment as a result of environmental insults. The astigmatic focus/push-pull tracking method is an elegant, easy-to-align focus- and track-error detection method. Unfortunately, it is also highly susceptible to feedthrough when astigmatism is present, with the worst effects caused by astigmatism oriented such that the tangential and sagittal foci are at 45 deg to the track direction. This disclosure outlines a method to nearly completely eliminate the worst-case form of feedthrough due to astigmatism oriented 45 deg to the track direction. Feedthrough due to other primary aberrations is not improved, but performance is identical to the unimproved astigmatic method.

Bernacki, Bruce E.↗

Astigmatism in reflector antennas.

Astigmatic phase error in large parabolic reflector antennas is discussed. A procedure for focusing an antenna and diagnosing the presence and degree of astigmatism is described. Theoretical analysis is conducted to determine the nature of this error in such antennas.

Cogdell, J. R.↗

Design and Performance Assessment of a Stable Astigmatic Herriott Cell for Trace Gas Measurements on Airborne Platforms

The present paper discusses a new, more stable, astigmatic Herriott cell employing carbon fiber stabilizing rods. Laboratory tests using a near-IR absorption feature of CO at 1564.168-nm revealed a factor of two improvement in measurement stability compared with the present commercial design when the sampling pressure was changed by +/-2 Torr around 50 Torr. This new cell should significantly enhance our efforts to measure trace gases employing pathlengths of 100 to 200-meters on airborne platforms with minimum detectable line center absorbances of less than 10(exp -6).

Dyroff, Christoph↗

Ring lens focusing and push-pull tracking scheme for optical disk systems

An experimental comparison of the ring lens and the astigmatic techniques of generating focus-error-signal (FES) in optical disk systems reveals that the ring lens generates a FES over two times steeper than that produced by the astigmat. Partly due to this large slope and, in part, because of its diffraction-limited behavior, the ring lens scheme exhibits superior performance characteristics. In particular the undesirable signal known as 'feedthrough' (induced on the FES by track-crossings during the seek operation) is lower by a factor of six compared to that observed with the astigmatic method. The ring lens is easy to align and has reasonable tolerance for positioning errors.

Gerber, R.↗

Aberrations of holographic toroidal grating systems

Expressions are derived for the sixteen wave front aberration coefficients of a single grating. These give the wave aberrations to the fourth order for a plane symmetric grating system. The contributions from each mirror and grating can be added to give the aberrations in the final image. Problems encountered with intermediate astigmatic images are overcome by defining the wave front aberration with respect to an astigmatic reference surface. There is one field variable describing displacement of the object point from the symmetry plane. The aperture stop may be placed anywhere in the system, and equations are given for the aberration changes produced by sifting this position.

Chrisp, M. P.↗

Four spot laser anemometer and optical access techniques for turbine applications

A time-of-flight anemometer (TOFA) system, utilizing a spatial lead-lag filter for bipolar pulse generation was constructed and tested. This system, called a Four Spot Laser Anemometer, was specifically designed for use in high speed, turbulent flows in the presence of walls or surfaces. The TOFA system uses elliptical spots to increase the flow acceptance angle to be comparable with that of a fringe type anemometer. The tightly focused spots used in the Four Spot yield excellent flare light rejection capabilities. Good results were obtained to 75 microns normal to a surface, with a f/2.5 collecting lens. This system is being evaluated for use in a warm turbine facility. Results from both a particle lag velocity experiment and boundary layer profiles will be discussed. In addition, an analysis of the use of curved windows in a turbine casing will be presented. Curved windows, matching the inner radius of the turbine casing, preserve the flow conditions, but introduce astigmatic aberrations. A correction optic was designed that virtually eliminates these astigmatic aberrations throughout the intrablade survey region for normal incidence.

Wernet, Mark P.↗

Four spot laser anemometer and optical access techniques for turbine applications

A time-of-flight anemometer (TOFA) system utilizing a spatial lead-lag filter for bipolar pulse generation has been constructed and tested. This system, called a four-spot laser anemometer, was specifically designed for use in high-speed, turbulent flows in the presence of walls or surfaces. The TOFA system uses elliptical spots to increase the flow acceptance angle to be comparable with that of a fringe-type anemometer. The tightly focused spots used in the four spot yield excellent flare light rejection capabilities. Good results have been obtained to 75 microns normal to a surface, with an f/2.5 collection lens. This system is being evaluated for use in a warm turbine facility. Results from both a particle-lag velocity experiment and boundary layer profiles will be discussed. In addition, an analysis of the use of curved windows in a turbine casing will be presented. Curved windows, matching the inner radius of the turbine casing, preserve the flow conditions, but introduce astigmatic aberrations. A correction optic was designed that virtually eliminates these astigmatic aberrations throughout the intrablade survey region for normal incidence.

Wernet, Mark P.↗

ORFEUS focal plane instrumentation: The Berkeley spectrometer

A spectrograph for the ORFEUS mission that incorporates four varied line-space, spherically figured diffraction gratings was designed. The ORFEUS, a 1-m normal incidence telescope is equipped with 2 focal plane spectrographs. The Berkeley spectrograph was developed with an optimizing raytracing computer code. Each grating accepts the light from 20 percent of the aperture of the telescope primary mirror and has a unique set of characteristics to cover a sub-bandpass within the 390 to 1200 A spectral range. Two photon-counting detectors incorporating a time delay readout system are used to record the spectra from all four gratings simultaneously. The nominal design achieves a spectral resolution (FWHM) in excess of 5500 at all wavelengths within the bandpass. The resolution is limited primarily by the detector spatial resolution. The 1 sigma astigmatism of this design varies between 13 and 150 micrometer on the same focal surface. An independent, direct imaging system tracks the drift of the target within the spectrometer aperture and allows measurement of the misalignment between the telescope optical axis and that of the external star tracker. The resolution and astigmatism achievable with this design are superior to those of a standard Rowland spectrograph designed with the same constraints.

Hurwitz, Mark↗

Aberrations of a horizontal-vertical depolarizer

Ray-trace equations for uniaxial birefringent materials are used here to derive third-order estimates for aberrations that are produced in imaging through uniaxial plates and horizontal-vertical (HV) depolarizers. An HV depolarizer is a spatial pseudodepolarizer; it converts a uniform input polarization state into a continuum of spatially varying polarization states in an output beam. An HV depolarizer consists of two birefringent wedges whose crystal axes are crossed at 90 deg. The interface between the wedges is included, which leads to a spatially varying retardance that provides the spatial pseudodepolarization. In HV depolarizers, spherical aberration, astigmatism, and image doubling are the principal aberrations for on-axis objects. Only spherical aberration occurs in isotropic plates, while the presence of birefringent wedges introduces astigmatism and image doubling. It is shown that image separation is proportional to the magnitude of the retardance variation.

Mcclain, Stephen C.↗

The fabrication of toroidal and coma-corrected toroidal diffraction gratings from spherical master gratings using elastically-deformable substrates - A progress report

A technique has been developed which permits toroidal, and coma-corrected toroidal, diffraction gratings to be replicated from spherical master gratings by the use of elastically-deformable substrates. Toroidal gratings correct for astigmatism and, thus, make it possible to construct stigmatic spectrometers that employ a single reflective diffraction grating. These spectrometers are particularly useful for the extreme-ultraviolet (EUV) wavelength range, where reflection coefficients are low, since the single optical surface provides for dispersion, focusing, and astigmatism correction. The fabrication procedures for the pure toroidal, and coma-corrected toroidal, gratings are described, and initial test results are presented. The use of the toroidal gratings in a high-resolution sounding-rocket EUV spectroheliometer, and in both the coronal diagnostics spectrometer and the ultraviolet coronagraph spectrometer on the ESA/NASA solar and heliospheric observatory mission, is described briefly, and the use of this technique for the fabrication of a coma-corrected toroidal grating for the prime Rowland spectrograph of the FUSE/Lyman mission is briefly discussed.

Huber, Martin C. E.↗

Fiber Grating Coupled Light Source Capable of Tunable, Single Frequency Operation

Fiber Bragg grating coupled light sources can achieve tunable single-frequency (single axial and lateral spatial mode) operation by correcting for a quadratic phase variation in the lateral dimension using an aperture stop. The output of a quasi-monochromatic light source such as a Fabry Perot laser diode is astigmatic. As a consequence of the astigmatism, coupling geometrics that accommodate the transverse numerical aperture of the laser are defocused in the lateral dimension, even for apsherical optics. The mismatch produces the quadratic phase variation in the feedback along the lateral axis at the facet of the laser that excites lateral modes of higher order than the TM 00 . Because the instability entails excitation of higher order lateral submodes, single frequency operation also is accomplished by using fiber Bragg gratings whose bandwidth is narrower than the submode spacing. This technique is particularly pertinent to the use of lensed fiber gratings in lieu of discrete coupling optics. Stable device operation requires overall phase match between the fed-back signal and the laser output. The fiber Bragg grating acts as a phase-preserving mirror when the Bragg condition is met precisely. The phase-match condition is maintained throughout the fiber tuning range by matching the Fabry-Perot axial mode wavelength to the passband center wavelength of the Bragg grating.

Michael A Krainak↗

Low-order aberration sensitivity of eighth-order coronagraph masks

In a recent paper, Kuchner, Crepp, and Ge describe new image-plane coronagraph mask designs that reject to eighth order the leakage of starlight caused by image motion at the mask, resulting in a substantial relaxation of image centroiding requirements compared to previous fourth-order and second-order masks. They also suggest that the new masks are effective at rejecting leakage caused by low-order aberrations (e.g., focus, coma, and astigmatism). In this paper, we derive the sensitivity of eighth-order masks to aberrations of any order and provide simulations of coronagraph behavior in the presence of optical aberrations.We find that the masks leak light as the fourth power of focus, astigmatism, coma, and trefoil. This has tremendous performance advantages for the Terrestrial Planet Finder Coronagraph.

planetary systems↗

Study of Objectives

Focal length, chromatic and spherical aberration, and astigmatism testing for astronomical telescope

FOCUSING↗

Sensitive visual test for concave diffraction gratings.

A simple visual test for the evaluation of concave diffraction gratings is described. It is twice as sensitive as the Foucault knife edge test, from which it is derived, and has the advantage that the images are straight and free of astigmatism. It is particularly useful for grating with high ruling frequency where the above image faults limit the utility of the Foucault test. The test can be interpreted quantitatively and can detect zonal grating space errors of as little as 0.1 A.

Bruner, E. C., Jr.↗

Fine guidance for a spaceborne telescope

Two transparent plates are mounted at equal and opposite angles in secondary optical-system housing, angles being set for optimum astigmatism correction. Rotation of secondary housing assembly and translation of detector are proportional to angular position of secondary image. Combined movement of two retains image within sagittal foci of secondary system.

Rosin, S.↗

Ritchey-Chretien Telescope

A Ritchey-Chretien telescope is described which was designed to respond to images located off the optical axis by using two transparent flat plates positioned in the ray path of the image. The flat plates have a tilt angle relative to the ray path to compensate for astigmatism introduced by the telescope. The tilt angle of the plates is directly proportional to the off axis angle of the image. The plates have opposite inclination angles relative to the ray paths. A detector which is responsive to the optical image as transmitted through the plates is positioned approximately on the sagittal focus of the telescope.

Rosin, S.↗