Search NASA⌕ Search

SEARCH · Search NASA

Results for “astromaterials curation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Organic Contamination Baseline Study in NASA Johnson Space Center Astromaterials Curation Laboratories

Future robotic and human spaceflight missions to the Moon, Mars, asteroids, and comets will require curating astromaterial samples with minimal inorganic and organic contamination to preserve the scientific integrity of each sample. 21st century sample return missions will focus on strict protocols for reducing organic contamination that have not been seen since the Apollo manned lunar landing program. To properly curate these materials, the Astromaterials Acquisition and Curation Office under the Astromaterial Research and Exploration Science Directorate at NASA Johnson Space Center houses and protects all extraterrestrial materials brought back to Earth that are controlled by the United States government. During fiscal year 2012, we conducted a year-long project to compile historical documentation and laboratory tests involving organic investigations at these facilities. In addition, we developed a plan to determine the current state of organic cleanliness in curation laboratories housing astromaterials. This was accomplished by focusing on current procedures and protocols for cleaning, sample handling, and storage. While the intention of this report is to give a comprehensive overview of the current state of organic cleanliness in JSC curation laboratories, it also provides a baseline for determining whether our cleaning procedures and sample handling protocols need to be adapted and/or augmented to meet the new requirements for future human spaceflight and robotic sample return missions.

Calaway, Michael J.↗

Applicability of Micro X-Ray Fluorescence Spectroscopy to Astromaterials Curation and Research

Introduction: The Astromaterials Acquisition and Curation Office at NASA’s Johnson Space Center (JSC) curates NASA’s astromaterial sample collections which includes: Apollo samples, Luna samples, Ant-arctic meteorites, cosmic dust particles, microparticle impacts into space-flown materials, Genesis solar wind atoms, Stardust comet Wild-2 particles, Stardust inter-stellar particles, Hayabusa asteroid Itokawa particles, Hayabusa 2 asteroid Ryugu particles, and future OSIRIS-Rex asteroid Bennu particles (landing in Sep-tember, 2023) [1–3]. To enhance JSC’s advanced cu-ration capabilities, we have recently installed a high-performance micro-X-ray fluorescence (µXRF) spec-trometer to assist in sample characterization through rapid, non-destructive, in-situ elemental analyses that do not require the sample preparation protocols (i.e., polishing and carbon-coating) commonly needed for electron beam analyses. With this new instrument, we are capable of detecting all elements down to carbon in a variable-pressure or He-purged chamber for anal-ysis of a wide range of sample types. Here we describe the instrumental set-up, capabilities, and applicability of µXRF analysis to astromaterials curation and re-search. Instrumentation and Methodology: The X-ray fluorescence and computed tomography lab (X-FaCT) lab at JSC is now equipped with a Bruker M4 Tornado Plus µXRF (Fig. 1). This system is an energy-dispersive x-ray spectrometer equipped with two 60 mm2 silicon drift detectors (SDD) that are able to be used simulta-neously for output count rates ~500,000 cps. New light element windows allow detecting and analyzing the entire elemental range from carbon to americium. Two x-ray tubes (micro-focus Rh with polycapillary lenses and W with collimators of 0.5, 1.0, 2.0, and 4.5 mm) with max excitation parameters of 50 kV, 30 W and 50 kV, 40 W, respectively, allow for more flexibility of the analysis of high energy lines. The motorized X-Y-Z stage has a mapping range of 190 x 160 mm and can support samples up to 7 kg (~15.5 lbs) and a height of 120 mm [4]. Analytical modes include elemental analysis (down to ~20 µm spot size) via point, line, or area of bulk materials (rock surfaces, thin sections, thick sections, etc.) as well as coating analysis (determination of thickness and composition) of samples. This system has a variable vacuum chamber (1 mbar to 1 atm) that is also equipped with a He-purge system which accommodates vacuum sensitive samples while still allowing detection of light elements at atmospheric pressure. Utility and Applicability of µXRF in Astro-materials research and exploration science (ARES): Elemental analysis using µXRF is commonly em-ployed for both terrestrial and planetary geological science disciplines [5]. It is especially useful for analy-sis of astromaterials given the limited sample prepara-tion required, which is not feasible for certain materi-als. Here we show select applications of µXRF anal-yses of astromaterials that can, have, and will be done at JSC’s X-FaCT lab. Point analysis: In-situ spot analyses (~20 µm spot size) on a cut slab of Martian meteorite NWA 10922 allowed for the discovery, qualitative elemental analy-sis and determination of different feldspar minerals [6]. These point analyses served as an effective prelim-inary step for subsequent quantitative analyses. Ana-lytical standards can be employed for more accurate quantification of µXRF spot analyses. Area analysis: This analytical mode measures all detectable elements (from C to Am) at each pixel (>5 µm pixel size) in a user-defined area. The results are shown as elemental maps which can be extracted as 16-bit TIFF’s for further data processing. In Fig. 2. we show elemental distribution maps of the high-Ti basalt 73001,531 that have been processed using ImageJ software. From these maps you can accurately and quickly (this map took ~50 mins.) identify mineral components, such as pyroxene, plagioclase, oxides, and phosphates, compositional zoning, and mineral textures. Detection of high-Z phases: µXRF techniques are es-pecially effective at analyzing trace minerals with high-atomic-number (high-Z) elements because the high-energy characteristic X-rays used (relative to SEM EDS) allow for mapping of K lines in elements up to La (typically SEM maps use L X-ray lines for elements >Zn, and these can often have interferences). Thus, µXRF is especially suited for identifying minerals like zircon, baddeleyite, REE-rich phosphates, Fe-rich met-als, oxides, sulfides, and phosphides [4]. In Fig. 3 we show elemental distribution maps for 73001,530 where we are able to correlate the original video image with, Zr, Si, Y and Hf elemental maps together identi-fying the location of a zircon. In this location you would expect lower Si compared to surrounding mate-rial, as well as higher Zr, Y, and Hf content compared to surrounding material, all of which is confirmed by our XRF ele-mental distribution maps (Figure 2.) Conclusions: The new M4 Tornado Plus µXRF within the Astromaterials Acquisition and Curation office at NASA JSC allows for rapid and non-destructive elemental analysis of astromaterials with limited or no sample preparation. µXRF analyses pro-vide crucial compositional knowledge for the prelimi-nary examination and curation of astromaterials. This instrument enhances the advanced curation capabili-ties in the X-FaCT laboratory at JSC by allowing pro-ductive, cohesive, and non-destructive multi-modal x-ray analyses on astromaterial samples, which is neces-sary for the comprehensive curation and study of our current and future astromaterial collections. Addition-ally, µXRF can provide complimentary information to researchers for studies on astromaterials. References: [1] Allen, C. et al., (2011). Chemie De Erde Geochemistry, 71, 1-20. [2] McCubbin, F. M. et al., (2016) 47th LPSC, abstract #2668 [3] Zeigler, R. A. et al., (2017) 48th LPSC, abstract #2772 [4] Bruker User Manual [5] Young et al., (2016) Appl. Geochemistry, 72, 77-87 [6] Mor-ris, R. V. et al., (2023) 54th LPSC.

E W O'Neal↗

A METHOD TO REDUCE BIOBURDEN IN ASTROMATERIALS CURATION FACILITIES WITHOUT INTRODUCING UNWANTED CONTAMINATION

Introduction: NASA curates its Astromaterials collections in cleanrooms that are carefully monitored for particulate, inorganic and trace metal contamination. Current sample collections are not particularly susceptible to organic contamination or biological alteration. However, new collections like those from the OSIRIS-REx and Hayabusa2 missions will have organic contamination requirements and are susceptible to biodegradation. It will be necessary sterilize or at least disinfect curation labs, as well as tools and equipment in a manner that does not introduce additional contamination and does not affect the samples 1. Current curation cleaning procedures utilize isopropyl alcohol which offers some bioburden reduction, but is not effective against spore-forming bacteria or fungal spores 2. We present a modified disinfection method that uses ultrapure hydrogen peroxide to reduce bioburden inside curation labs and glove boxes without introducing contamination or damaging curation equipment. We tested this method in the meteorite processing lab as well as on a glovebox being cleaned for use in processing ANGSA (Apollo Next Generation Sample Analysis) samples and present the results of those tests. We discuss the limitations of this method and describe potential situations in which it will not be applicable. The CDC guidelines for disinfection andsterilization in healthcare facilities discusses over 15different methods for reducing bioburden in hospitalsettings 3. The most common method, steamsterilization, is well suited to sterilizing curationprocessing tools but cannot easily be used to sterilizecleanroom surfaces or large equipment likegloveboxes. Chemical sterilization with bleach(NaOCl) is also a common strategy in healthcare andpharmaceutical settings that presents materialcompatibility issues as well as serious inorganiccontamination concerns for curation facilities.Introducing a new source of Na and Cl into curationlabs is not acceptable. Other chemical methods likeethylene oxide, formaldehyde, iodophors andquaternary ammonium compounds could introduceorganic and inorganic contamination. We chose tofocus on hydrogen peroxide because it is generallycompatible with commonly used curation materialslike stainless steel, aluminum and Teflon and becauseit decomposes to oxygen and water. The CDCguidelines for hydrogen peroxide specify using a 7.5wt% solution at 25 ̊C with a contact time of 30 minutesfor high level disinfection and 6 hours for sterilization.High level disinfection is defined as a technique thatwill kill all microorganisms except large numbers ofbacterial spores 3. Methods: We prepared a solution of 7.5 wt%hydrogen peroxide from a stock solution of ultrapure30 wt% peroxide (JT Baker) and curation gradeultrapure water. This ultrapure water is already used incuration cleaning procedures and thus is not consideredand additional source of contamination. We conducteda materials compatibility test by exposing unanodizedand anodized 6061 T6 Al alloy to the peroxide solutionfor up to six hours and periodically inspecting thesurfaces for visible defects. We used this peroxide todisinfect the floor of the meteorite processing lab andthe interior of a curation glovebox by exposing thesesurfaces to the peroxide solution for 30 min. Thesurfaces were swabbed with a dry macrofoam swabbefore (Puritan Brand 2518051PFRNDFD) and afterperoxide treatment to collect microbes present on thesurfaces. Microbes were extracted by sonication fromthe swab into 15 ml of PBS (phosphate buffered saline)and inoculated onto the following media: TSA (trypticsoy agar) BA (blood agar), R2A (Reasoners 2 agar),Potato Dextrose Agar, Saboraud Dextrose Agar andSaboraud Dextrose Agar with 0.1 mg/ mlchloramphenicol. Four TSA plates and two BA plateswere inoculated with 0.1 ml of PBS each andincubated at 35 and 37 for 48 hours. Two R2A°C°Cplates (0.1 ml of PBS each) were incubated at 25 .°CThe remaining plates were inoculated with 0.2ml ofPBS and incubated at 30 ̊C for seven days. Afterincubation bacterial and fungal isolates were countedand transferred to new plates for identification usingthe VITEK24 automated system or by sequencing aportion of the barcode gene (16S rRNA for bacteria,small subunit gene for fungi) on an ABI 3500 Sangersequencer. Negative controls consisted of swabs thatwere opened in the sampling environment andanalyzed alongside the experimental samples.Results: A 6 hour exposure to hydrogen peroxideresulted in visible pitting on un-anodized 6061 Al, butnot on anodized surfaces. No visible pitting occurredafter a 30 minute exposure. Therefore, we decided tolimit our experimental tests to 30 min. exposures. 17bacterial CFU (colony forming units) representing 4distinct organisms were isolated from the meteorite processing lab floor prior to hydrogen peroxidetreatment. We were unable culture any organisms afterperoxide treatment. In the glovebox we were able toculture three bacterial CFU representing three distinctspecies, including a spore forming bacterium prior todisinfection with peroxide. After the peroxidetreatment we were unable to culture any organisms.Routine monitoring of the meteorite processing lab andthe glovebox did not indicate any increase in unwantedinorganic contamination after these peroxidetreatments. Discussion: A 30 minute treatment with 7.5 wt%peroxide appears to be an effective method forreducing bioburden on typical cleanroom surfaces. Themethod does not introduce unwanted organic orinorganic contamination and is compatible withcommonly used curation materials like stainless steel,Teflon and anodized aluminum alloys. Special careshould be taken with un-anodized aluminum.Prolonged exposure to hydrogen peroxide can causepitting on this material. We recommend using thismethod to disinfect curation labs and equipment whenbiological alteration is a concern. This method iseffective at room temperature and cannot be used todisinfect labs and equipment where the ambienttemperature is < 0 ̊C. Astromaterials samples shouldbe removed from the area where disinfection is tooccur. Hydrogen peroxide is a powerful oxidizingagent and will react with any organic carbon present inthe sample. References: [1.] Mccubbin, F. M. et al.Sp. Sci Rev(2019) doi:10.1007/s11214-019-0615-9. [2.] Mogul, R.et al.Astrobiology 18, ast.2017.1814 (2018). [3.]Rutala, W. A. & Weber, D. J. Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008. [4.] Pincus, D. H. in Encyclopedia of Rapid Microbiological Methods (2005).

A. B. Regberg↗

Improving the Discoverability and Availability of Sample Data and Imagery in NASA's Astromaterials Curation Digital Repository Using a New Common Architecture for Sample Databases

The Astromaterials Acquisition and Curation Office at NASA's Johnson Space Center (JSC) is the designated facility for curating all of NASA's extraterrestrial samples. The suite of collections includes the lunar samples from the Apollo missions, cosmic dust particles falling into the Earth's atmosphere, meteorites collected in Antarctica, comet and interstellar dust particles from the Stardust mission, asteroid particles from the Japanese Hayabusa mission, and solar wind atoms collected during the Genesis mission. To support planetary science research on these samples, NASA's Astromaterials Curation Office hosts the Astromaterials Curation Digital Repository, which provides descriptions of the missions and collections, and critical information about each individual sample. Our office is implementing several informatics initiatives with the goal of better serving the planetary research community. One of these initiatives aims to increase the availability and discoverability of sample data and images through the use of a newly designed common architecture for Astromaterials Curation databases.

Todd, N. S.↗

Astromaterials Curation Online Resources for Principal Investigators

The Astromaterials Acquisition and Curation office at NASA Johnson Space Center curates all of NASA's extraterrestrial samples, the most extensive set of astromaterials samples available to the research community worldwide. The office allocates ~1500 individual samples to researchers and students each year and has served the planetary research community for 45+ years. The Astromaterials Curation office provides access to its sample data repository and digital resources to support the research needs of sample investigators and to aid in the selection and request of samples for scientific study. These resources can be found on the Astromaterials Acquisition and Curation website at https://curator.jsc.nasa.gov. To better serve our users, we have engaged in several activities to enhance the data available for astromaterials samples, to improve the accessibility and performance of the website, and to address user feedback. We havealso put plans in place for continuing improvements to our existing data products.

Todd, Nancy S.↗

Advances in Astromaterials Curation: Supporting Future Sample Return Missions

NASA's Astromaterials, curated at the Johnson Space Center in Houston, are the most extensive, best-documented, and leastcontaminated extraterrestrial samples that are provided to the worldwide research community. These samples include lunar samples from the Apollo missions, meteorites collected over nearly 40 years of expeditions to Antarctica (providing samples of dozens of asteroid bodies, the Moon, and Mars), Genesis solar wind samples, cosmic dust collected by NASA's high altitude airplanes, Comet Wild 2 and interstellar dust samples from the Stardust mission, and asteroid samples from JAXA's Hayabusa mission. A full account of NASA's curation efforts for these collections is provided by Allen, et al [1]. On average, we annually allocate about 1500 individual samples from NASA's astromaterials collections to hundreds of researchers from around the world, including graduate students and post-doctoral scientists; our allocation rate has roughly doubled over the past 10 years. The curation protocols developed for the lunar samples returned from the Apollo missions remain relevant and are adapted to new and future missions. Several lessons from the Apollo missions, including the need for early involvement of curation scientists in mission planning [1], have been applied to all subsequent sample return campaigns. From the 2013 National Academy of Sciences report [2]: "Curation is the critical interface between sample return missions and laboratory research. Proper curation has maintained the scientific integrity and utility of the Apollo, Antarctic meteorite, and cosmic dust collections for decades. Each of these collections continues to yield important new science. In the past decade, new state-of-the-art curatorial facilities for the Genesis and Stardust missions were key to the scientific breakthroughs provided by these missions." The results speak for themselves: research on NASA's astromaterials result in hundreds of papers annually, yield fundamental discoveries about the evolution of the solar system (e.g. [3] and references contained therein), and serve the global scientific community as ground truth for current and planned missions such as NASA's Dawn mission to Vesta and Ceres, and the future OSIRIS REx mission to asteroid Bennu [1,3]

Evans, C. A.↗

Microbial Monitoring of Astromaterials Curation Labs Reveals Inter-Lab Diversity

The Astromaterials Curation Division at NASA’s Johnson Space Center houses seven sample collections stored in separate clean rooms to avoid cross-contamination. Prior to receiving new sample collections from carbon rich asteroids, we instituted a monitoring program to characterize the microbial ecology of these labs and to understand how organisms could interact with and potentially contaminate current and future collections. Methods: Beginning in Oct. 2017 we sampled the Meteorite (ISO 7 equivalent) and Pristine Lunar (ISO 5 equivalent) labs on a monthly basis. Surface samples were collected using dry swabs. Air samples were collected using an impactor style air sampler. Cultivable organisms were identified and characterized. Aliquots of each sample were also preserved for DNA sequencing. For each sampling event recovery rate was calculated as the percentage of samples showing microbial growth1. Fungal colonies were selected for amino acid extraction and analysis via Ultra- Performance Liquid Chromatography with Fluorescence Detection and Mass Spectrometry.

Regberg, A. B.↗

Biogeochemistry, Planetary Protection, and Astromaterials Curation: A Story of Environmental Microbiology at NASA

The astromaterials curation office at the NASA Johnson Space Center is responsible for curating and allocating all of the extraterrestrial samples collected by NASA. This includes lunar samples, meteorites, cometary material, asteroid samples and individual atoms of the solar wind. Some of these collections are susceptible to biological alteration by terrestrial microbes. I will describe the microbial monitoring of the clean rooms used to store these samples and the ecology we find therein. This research is helping NASA design better cleanrooms for even more sensitive samples like those currently being collected on Mars. I will also discuss our group’s research on improved identification methods, biological alteration of meteorites, and efforts to sample microbes on the outside of the International Space Station.

Aaron B. Regberg↗

Investigating Astromaterials Curation Applications for Dexterous Robotic Arms

The Astromaterials Acquisition and Curation office at NASA Johnson Space Center is currently investigating tools and methods that will enable the curation of future astromaterials collections. Size and temperature constraints for astromaterials to be collected by current and future proposed missions will require the development of new robotic sample and tool handling capabilities. NASA Curation has investigated the application of robot arms in the past, and robotic 3-axis micromanipulators are currently in use for small particle curation in the Stardust and Cosmic Dust laboratories. While 3-axis micromanipulators have been extremely successful for activities involving the transfer of isolated particles in the 5-20 micron range (e.g. from microscope slide to epoxy bullet tip, beryllium SEM disk), their limited ranges of motion and lack of yaw, pitch, and roll degrees of freedom restrict their utility in other applications. For instance, curators removing particles from cosmic dust collectors by hand often employ scooping and rotating motions to successfully free trapped particles from the silicone oil coatings. Similar scooping and rotating motions are also employed when isolating a specific particle of interest from an aliquot of crushed meteorite. While cosmic dust curators have been remarkably successful with these kinds of particle manipulations using handheld tools, operator fatigue limits the number of particles that can be removed during a given extraction session. The challenges for curation of small particles will be exacerbated by mission requirements that samples be processed in N2 sample cabinets (i.e. gloveboxes). We have been investigating the use of compact robot arms to facilitate sample handling within gloveboxes. Six-axis robot arms potentially have applications beyond small particle manipulation. For instance, future sample return missions may involve biologically sensitive astromaterials that can be easily compromised by physical interaction with a curator; other potential future returned samples may require cryogenic curation. Robot arms may be combined with high resolution cameras within a sample cabinet and controlled remotely by curator. Sophisticated robot arm and hand combination systems can be programmed to mimic the movements of a curator wearing a data glove; successful implementation of such a system may ultimately allow a curator to virtually operate in a nitrogen, cryogenic, or biologically sensitive environment with dexterity comparable to that of a curator physically handling samples in a glove box.

Snead, C. J.↗

Astromaterial Curation and Research at NASA

Astromaterial sample return missions from other planetary bodies (e.g., the Moon, asteroids, the Sun) and astromaterial sample collection missions here on Earth (e.g., Antarctic Meteorites, Cosmic Dust) have been a vital part of NASA’s science vision since nearly its inception. Beginning with the Apollo missions to the Moon and extending to the recent successful sample collection by the OSIRIS-REx asteroid sample return mission, these astromaterials collections have been an invaluable resource to scientists and educators around the world. Sample studies continue to provide fundamental insight into how our solar system and its constituent bodies formed and evolved over the past 4.5 billion years. As evidence of their broad impact, there are over 19,141 samples on loan to 433 Principal Investigators in 24 countries [1]. As we plan for exploration missions through 2050, sample return missions will continue to play a vital role in NASA’s science vision. Returned samples truly are the gift that keeps on giving. Having the samples accessible on Earth allows new generations of scientists and new generations of instrumentation to pursue ever evolving scientific questions. For example, the Apollo samples were collected ~50 years ago, yet our views of how the Earth-Moon system formed, the role of volatiles in the early inner solar system, and even the positions of the gas giants in the outer solar system have changed dramatically as a result of Apollo sample analyses conducted very recently. Vital to the long-term viability of any sample return mission is the careful curation of the samples. Curatorial efforts need to begin early in the project lifecycle, not with the return of the samples, but at mission conception. The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center is responsible for curating all of NASA’s current and future extraterrestrial samples. Looking at possible sample return missions over the next 35+ years [2], many samples would require curation efforts a step beyond current capabilities, e.g., cold or cryogenic curation, organically and biologically clean curation, curation of gases and ices, and curation of samples with extreme pressure, temperature, or redox requirements. During the lecture, we discuss the current curatorial efforts in JSC curation, as well as discoveries from the astromaterial research. [1] Zeigler, R. A. et al. (2017) Planetary Science Vision 2050 Workshop. [2] McCubbin F. M. et al. (2017) Planetary Science Vision 2050 Workshop.

astromaterial↗

Insights From Routine Microbiological Monitoring of Air in Astromaterials Curation Cleanrooms

NASA maintains nine separate cleanrooms at the Johnson Space Center to curate and preserve astromaterials samples. Routine microbial monitoring of the surfaces in these cleanrooms began in 20181. Until recently, materials compatibility requirements prevented monitoring airborne biological particles in all but one of these cleanrooms. New astromaterials collections from carbon rich asteroids are more susceptible to biological degradation than previous collections. Therefore, it is important to monitor the bioburden in the air and on surfaces in these labs. Establishing a comprehensive microbial monitoring program will help inform the monitoring and curation plans for Mars sample return which will include samples that are extremely biologically sensitive. In April of 2022 we began routinely collecting air samples in seven of the nine curation cleanrooms (Meteorite ISO 7 equivalent, Lunar ISO 6 equivalent, Stardust, Hayabusa2, OSIRIS-REx ISO 5 equivalent, and Genesis ISO 4 equivalent) using a sampling device that collects airborne biological particles on an electret filter instead conventional sampler that collect cells in a liquid media or onto organic rich Petri dishes. Electret is a generic term for electrostatically charged media. The charge on these materials increases particle trapping when compared to non-charged filters of similar thickness. N95 respirators also use electret filters. This dry sample collection method allows us to meet materials requirements for all the curation labs and reduces the risk of inadvertently introducing contamination as part of our monitoring effort. This method also allows us to preserve a portion of each sample for DNA extraction and next generation sequencing. DNA sequencing helps us to characterize the portion of the cleanroom microbiome that we cannot culture. We will present the results of our first 8 months of monitoring, compare these results to particle counts in the labs and to measurements made directly onto Petri dishes when possible. We will also make recommendations for modifications to the sampling method to improve sampling efficiency and preserve diversity.

A. B. Regberg↗

Reducing Organic Contamination in NASA JSC Astromaterial Curation Facility

Future robotic and human spaceflight missions to the Moon, Mars, asteroids and comets will require handling and storing astromaterial samples with minimal inorganic and organic contamination to preserve the scientific integrity of each sample. Much was learned from the rigorous attempts to minimize and monitor organic contamination during Apollo, but it was not adequate for current analytical requirements; thus [1]. OSIRIS-REx, Hayabusa-2, and future Mars sample return will require better protocols for reducing organic contamination. Future isolation con-tainment systems for astromaterials, possibly nitrogen enriched gloveboxes, must be able to reduce organic and inorganic cross-contamination. In 2012, a baseline study established the current state of organic cleanliness in gloveboxes used by NASA JSC astromaterials curation labs that could be used as a benchmark for future mission designs [2, 3]. After standard ultra-pure water (UPW) cleaning, the majority of organic contaminates found were hydrocarbons, plasticizers, silicones, and solvents. Hydro-carbons loads (> C7) ranged from 1.9 to 11.8 ng/cm2 for TD-GC-MS wafer exposure analyses and 5.0 to 19.5 ng/L for TD-GC-MS adsorbent tube exposure. Plasticizers included < 0.6 ng/cm2 of DBP, DEP, TXIB, and DIBP. Silicones included < 0.5 ng/cm2 of cyclo(Me2SiO)x (x = 6, 8, 9, 10) and siloxane. Solvents included < 1.0 ng/cm2 of 2-cyclohexen-1-one, 3,5,5-trimethyl- (Isopho-rone), N-formylpiperidine, and 2-(2-butoxyethoxy) ethanol. In addition, DBF, rubber/polymer additive was found at < 0.2 ng/cm2 and caprolactam, nylon-6 at < 0.6 ng/cm2. Reducing Organics: The Apollo program was the last sam-ple return mission to place high-level organic requirements and biological containment protocols on a curation facility. The high vacuum complex F-201 glovebox in the Lunar Receiving Labora-tory used ethyl alcohol (190 proof), 3:1 benzene/methanol (nano grade solution), and heat sterilization at 130degC for 48 hours to reduce organic contamination. In addition, both heat sterilization and peracetic acid sterilization were used in the atmospheric de-contamination (R) cabinets. Later, Lunar curation gloveboxes were degreased with a pressurized Freon 113 wash. Today, UPW has replaced Freon as the standard cleaning procedure, but does not have the degreasing solvency power of Freon. Future Cleaning Studies: Cleaning experiments are cur-rently being orchestrated to study how to degrease and reduce organics in a JSC curation glovebox lower than the established baseline. Several new chemicals in the industry have replaced traditional degreasing solvents such as Freon and others that are now federally restricted. However, these new suites of chemicals remain untested for lowering organics in curation gloveboxes. 3M's HFE-7100DL and DuPont's Vertrel XF are currently being tested as a replacement for Freon 113 as a degreaser at JSC cura-tion facilities. In addition, the use of UPW as a final rinse is be-ing tested, which presumably can maintain a lower total organic carbon load than the filtered purity of chemical solutions. References: [1] Allton J.H. et al. (2012) LPS XLIII, 2439; [2] Calaway M.

Calaway, M. J.↗

Organic Contamination Baseline Study on NASA JSC Astromaterial Curation Gloveboxes

Future planned sample return missions to carbon-rich asteroids and Mars in the next two decades will require strict handling and curation protocols as well as new procedures for reducing organic contamination. After the Apollo program, astromaterial collections have mainly been concerned with inorganic contamination [1-4]. However, future isolation containment systems for astromaterials, possibly nitrogen enriched gloveboxes, must be able to reduce organic and inorganic cross-contamination. In 2012, a baseline study was orchestrated to establish the current state of organic cleanliness in gloveboxes used by NASA JSC astromaterials curation labs that could be used as a benchmark for future mission designs.

Calaway, Michael J.↗

Meca500 Robotic Arm Developments Towards Astromaterials Curation Applications

As a part of the ongoing efforts to develop new curation tools and techniques for astromaterials within the Astromaterials Acquisition and Curation office at NASA’s Johnson Space Center, we are developing a variety of manually and electrically controlled micromanipulation systems. Most current techniques require manual manipulation, and in some cases the manipulation task is being done entirely freehand. The motorized systems avail-able are restricted to three degrees of freedom and use proprietary control systems. For example, the MicroSupport AxisPro manipulation system currently used in microscale particle experiments is limited in its range of motion, as it can only move the manipulators in a three axis Cartesian range over a predetermined area above microscope slides. While having an efficient user interface, the control system is proprietary and prevents custom development and optimization to extend the viable applications of the system. In order to address some of these limitations, we have been testing robotic designs with multiple degrees of freedom and of a variety of designs. We are currently investigating the Meca500 robotic arm by Mecademic as a potential manipulation system to overcome some of these obstacles.

Cowden, T. R.↗

Ultra Pure Water Cleaning Baseline Study on NASA JSC Astromaterial Curation Gloveboxes

Future sample return missions will require strict protocols and procedures for reducing inorganic and organic contamination in isolation containment systems. In 2012, a baseline study was orchestrated to establish the current state of organic cleanliness in gloveboxes used by NASA JSC astromaterials curation labs [1, 2]. As part of this in-depth organic study, the current curatorial technical support procedure (TSP) 23 was used for cleaning the gloveboxes with ultra pure water (UPW) [3-5]. Particle counts and identification were obtained that could be used as a benchmark for future mission designs that require glovebox decontamination. The UPW baseline study demonstrates that TSP 23 works well for gloveboxes that have been thoroughly degreased. However, TSP 23 could be augmented to provide even better glovebox decontamination. JSC 03243 could be used as a starting point for further investigating optimal cleaning techniques and procedures. DuPont Vertrel XF or other chemical substitutes to replace Freon- 113, mechanical scrubbing, and newer technology could be used to enhance glovebox cleanliness in addition to high purity UPW final rinsing. Future sample return missions will significantly benefit from further cleaning studies to reduce inorganic and organic contamination.

Calaway, Michael J.↗

Technical Tension Between Achieving Particulate and Molecular Organic Environmental Cleanliness: Data from Astromaterial Curation Laboratories

NASA Johnson Space Center operates clean curation facilities for Apollo lunar, Antarctic meteorite, stratospheric cosmic dust, Stardust comet and Genesis solar wind samples. Each of these collections is curated separately due unique requirements. The purpose of this abstract is to highlight the technical tensions between providing particulate cleanliness and molecular cleanliness, illustrated using data from curation laboratories. Strict control of three components are required for curating samples cleanly: a clean environment; clean containers and tools that touch samples; and use of non-shedding materials of cleanable chemistry and smooth surface finish. This abstract focuses on environmental cleanliness and the technical tension between achieving particulate and molecular cleanliness. An environment in which a sample is manipulated or stored can be a room, an enclosed glovebox (or robotic isolation chamber) or an individual sample container.

Allton, J. H.↗

Organic Contamination Baseline Study: In NASA JSC Astromaterials Curation Laboratories. Summary Report

In preparation for OSIRIS-REx and other future sample return missions concerned with analyzing organics, we conducted an Organic Contamination Baseline Study for JSC Curation Labsoratories in FY12. For FY12 testing, organic baseline study focused only on molecular organic contamination in JSC curation gloveboxes: presumably future collections (i.e. Lunar, Mars, asteroid missions) would use isolation containment systems over only cleanrooms for primary sample storage. This decision was made due to limit historical data on curation gloveboxes, limited IR&D funds and Genesis routinely monitors organics in their ISO class 4 cleanrooms.

Calaway, Michael J.↗