Search NASA⌕ Search

SEARCH · Search NASA

Results for “atomic and molecular spectra”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Explicit Hilbert-space representations of atomic and molecular photoabsorption spectra - Computational studies of Stieltjes-Tchebycheff functions

Computational methods are reported for construction of discrete and continuum Schroedinger states in atoms and molecules employing explicit Hilbert space procedures familiar from bound state studies. As theoretical development, the Schroedinger problem of interest is described, the Cauchy-Lanczos bases and orthonormal polynomials used in constructing L-squared Stieltjes-Tchebycheff (ST) approximations to the discrete and continuum states are defined, and certain properties of these functions are indicated. Advantages and limitations of the ST approach to spectral studies relative to more conventional calculations are discussed, and aspects of the approach in single-channel approximations to larger molecules are described. Procedures are indicated for construction of photoejection anisotropies and for performing coupled-channel calculations employing the ST formalism. Finally, explicit descriptive intercomparisons are made of the nature and diagnostic value of ST functions with more conventional scattering functions.

Hermann, M. R.↗

Scalar and vector collisional interference in the vibration-rotation absorption spectra of H2 and HD

The only atomic or molecular spectra known to exhibit 'collisional interference' effects are those of H2 and its isotopes. Attention is presently given to the sharp absorption spectra of HD, which demonstrate collisional interference effects is a fashion that while surprising has been experimentally verified and theoretically characterized in detail. Collisional interference can dramatically alter the line shapes usually encountered in dipole absorption spectra, while nevertheless remaining narrow.

Herman, R. M.↗

Ground-based observations of comets, the Jupiter plasma Torus, and Io

Aspects of cometary and magnetospheric physics were investigated by means of ground-based astronomical spectroscopy. High-throughput, dual-etalon Fabry-Perot spectrometers were used to obtain very high resolution spectra of atomic, molecular, and ionic emission lines from the diffuse gases and plasmas associated with comets and the Jupiter plasma torus. The Fabry-Perot spectrometers were also used with a charge coupled device (CCD) camera to obtain images of these extended emission sources in individual spectral lines at high spectral resolution. A new program using the McMath solar-stellar spectrograph to observe emission lines from Io was recently initiated. The McMath spectrograph has a high resolution mode which allows the detection of narrow, relatively faint emission lines superimposed on Io's reflected solar spectrum.

Scherb, Frank↗

Laser Optogalvanic Spectroscopy pf Neon and Argon in a Discharge Plasma and its Significance for Microgravity Combustion

A detailed study of combustion mechanisms in flames, employing laser-based diagnostics, has provided good knowledge and understanding of the physical phenomena, and led to better characterization of the dynamical and chemical combustion processes, both under low-gravity (in space) and normal gravity (in ground based facilities, e.g. drop towers). Laser induced fluorescence (LIF), laser-induced incandescence (LII) and LIF thermometry have been widely used to perform nonintrusive measurements and to better understand combustion phenomena. Laser optogalvanic (LOG) spectroscopy has well-established applications in ion mobility measurements, atomic and molecular spectroscopy, ionization rates, recombination rates, velocity measurements and as a combustion probe for trace element detection. Absorption spectra of atomic and molecular species in flames can be obtained via LOG spectroscopy by measuring the voltage and current changes induced by laser irradiation. There are different kinds of processes that contribute to a discharge current, namely: (1) electron impact ionization, (2) collisions among the excited atoms of the discharge species and (3) Penning ionization. In general, at higher discharge currents, the mechanism of electron impact ionization dominates over Penning ionization, whereby the latter is hardly noticeable. In a plasma, whenever the wavelength of a laser coincides with the absorption of an atomic or molecular species, the rate of ionization of the species momentarily increases or decreases due to laser-assisted acceleration of collisional ionization. Such a rate of change in the ionization is monitored as a variation in the transient current by inserting a high voltage electrode into the plasma. Optogalvanic spectroscopy in discharges has been useful for characterizing laser line-widths and for providing convenient calibration lines for tunable dye lasers in the ultraviolet, visible and infrared wavelength regions. Different kinds of quantitative information, such as the electron collisional ionization rate, can be extracted from the complex processes occurring within the discharge. In the optogalvanic effect (OGE), there is no problem of overlap from background emissions, and hence even weak signals can be detected with a high signal-to-noise ratio, which makes the optogalvanic effect sensitive enough to resolve vibrational changes in molecular bonds and differences in energy levels brought about by different electron spins. For calibration purposes, neon and argon gaseous discharges have been employed most extensively, because these gases are commonly used as buffer gases within hollow-cathode lamps and provide an acceptable density of calibration lines. In the present work, our main aim has been to understand the dominant physical processes responsible for the production of the OGE signal, based on the extensive time resolved optogalvanic waveforms recorded, and also to extract quantitative information on the rates of excited state collisional processes.

Misra, Prabhakar↗

Spectra from nuclear-excited plasmas

The paper discusses the spectra taken from He-3(n,p)H-3 nuclear-induced plasmas under high thermal neutron flux, lasing conditions. Also, initial spectra are presented for U-235F6 generated plasmas. From an evaluation of these spectra, important atomic and molecular processes that occur in the plasma can be inferred. The spectra presented are the first to be generated by He-3 and U-235F6 nuclear reactions under high neutron flux, lasing conditions. The U-235(n,ff)FF reaction, which liberates 165 MeV of fission-fragment kinetic energy, creates plasmas that are of great interest, since at sufficiently high densities of U-235F6 the gas becomes self-critical; thus, there is no need for an external driving reactor (source of neutrons). The spectra from mixtures of He-3 and Ar, Xe, Kr, Ne, Cl2, F2 and N2 indicate little difference between high-pressure nuclear-induced plasmas and high-pressure electrically pulsed afterglow plasmas for noble-gas systems

De Young, R. J.↗

Atomic and molecular data for space astronomy - Needs, analysis, and availability; 21st IAU General Assembly, Buenos Aires, Argentina, July 23-Aug. 1, 1991, Selected Papers

The present volume on atomic and molecular spectroscopic data for space astrophysics discusses scientific problems and laboratory data needs associated with the Hubble Space Telescope, atomic data needed for far ultraviolet astronomy with HUT and FUSE and for analysis of EUV and X-ray spectra, and data for observations of interstellar medium with the Hubble Space Telescope. Attention is also given to atomic and molecular data for analysis of IR spectra from ISO and SIRTF, atomic data from the opacity project, sources of atomic spectroscopic data for astrophysics, and summary of current molecular data bases.

Smith, Peter L.↗

Laboratory Spectroscopy of Large Carbon Molecules and Ions in Support of Space Missions

One of the major objectives of Laboratory Astrophysics is the optimization of data return from space missions by measuring spectra of atomic and molecular species in laboratory environments that mimic interstellar conditions (WhitePaper (2002, 2006)). Among interstellar species, PAHs are an important and ubiquitous component of carbon-bearing materials that represents a particularly difficult challenge for gas-phase laboratory studies. We present the absorption spectra of jet-cooled neutral and ionized PAHs and discuss the implications for astrophysics. The harsh physical conditions of the interstellar medium have been simulated in the laboratory. We are now, for the first time, in the position to directly compare laboratory spectra of PAHs and carbon nanoparticles with astronomical observations. This new phase offers tremendous opportunities for the data analysis of current and upcoming space missions geared toward the detection of large aromatic systems (HST/COS, FUSE, JWST, Spitzer).

Salana, Farid↗

Hydrogen emission from Jupiter: Hydrogen emission from sunlit atmosphere of Saturn

Successful IUE observations of the equatorial sunlit atmosphere of Jupiter and Saturn have been obtained. Spectra containing atomic and molecular hydrogen and solar reflection continuum emissions have been analyzed, with the purpose of determining the long term temporal behavior of the electroglow process. Quantitative estimates have been established for the first time using a model analysis of the short wavelength region of the spectrum. Both systems show varying degrees of long term variability in hydrogen emission rate, but the time scale is too short to determine whether there is a dependence on solar cycle activity. As part of the emission modeling program, a preliminary point source spreading function for the IUE SWP instrument has been established, suggesting a wavelength dependence in spectral line width different from previous analyses. Further IUE observations are planned for both Jupiter and Saturn.

Shemansky, D. E.↗

Excitation of atomic nitrogen by electron impact

Absolute cross sections were measured for the excitation of the N I(1134, 1164, 1168, 1200, 1243, and 1743 A) multiplets by electron impact on atomic nitrogen. The presence of vibrationally excited molecular nitrogen in the discharged gas was confirmed, and its effect on the measurements is discussed. The ratio of the oscillator strengths of the 1200 and 1134 A resonance transitions is presented, as well as the branching ratio for the N I(1311/1164 A) multiplets. Striking differences in the distribution of intensity between the spectra of atomic nitrogen and molecular nitrogen excited by energetic electrons suggest an optical method for measuring the density of atomic nitrogen in the upper atmosphere.

Stone, E. J.↗

The Mariner Jupiter/Saturn ultraviolet experiment

Atmospheric properties of Saturn's rings as measured by an ultraviolet spectrometer onboard the Mariner Jupiter/Saturn probe are studied. Measurements were made of planetary atmospheric radiation, resonance scattered by atomic or molecular constituents, solar spectra, and the absorption characteristics of the atmosphere. Measurements were made in the 400 to 1600 A region.

Broadfoot, A. L.↗

Detection of nitric oxide pollution

Studies of absorption spectra enhancement of certain atomic and molecular species inserter in dye-laser cavities have indicated that nitric oxide can be determined at low concentrations. Absorption coefficient of small amounts of nitric oxide in intra-laser-cavity absorption cell containing helium is enhanced by more than two orders of magnitude.

Chackerian, C., Jr.↗

Planetary and satellite x ray spectroscopy: A new window on solid-body composition by remote sensing

The rings and most of the satellites of the outer planets orbit within the radiation belts of their parent bodies. This is an environment with intense fluxes of energetic electrons. As a result, these objects are strong emitters of X-rays. The characteristic X-ray lines from these bodies depend on atomic composition, but they are not sensitive to how the material is arranged in compounds or mixtures. X-ray fluorescence spectral analysis has demonstrated its unique value in the laboratory as a qualitative and quantitative analysis tool. This technique has yet to be fully exploited in a planetary instrument for remote sensing. The characteristic X-ray emissions provide atomic relative abundances. These results are complementary to the molecular composition information obtained from IR, visible, and UV emission spectra. The atomic relative abundances are crucial to understanding the formation and evolution of these bodies. They are also crucial to the proper interpretation of the molecular composition results from the other sensors. The intensities of the characteristic X-ray emissions are sufficiently strong to be measured with an instrument of modest size. Recent developments in X-ray detector technologies and electronic miniaturization have made possible space-flight X-ray imaging and nonimaging spectrometers of high sensitivity and excellent energy resolution that are rugged enough to survive long-duration space missions. Depending on the application, such instruments are capable of resolving elemental abundances of elements from carbon through iron. At the same time, by measuring the bremsstrahlung intensity and energy spectrum, the characteristics of the source electron flux can be determined. We will discuss these concepts, including estimated source strengths, and will describe a small instrument capable of providing this unique channel of information for future planetary missions. We propose to build this instrument using innovative electronics packaging methods to minimize size and weight.

Chenette, D. L.↗

Vibrational and rotational analysis of the emission spectra of the arc jet flow

Applying atomic and molecular physics to the analysis of the radiation emitted from the arc jet flow provides a means for determining the species and excitation temperature of the constituents of the flow. A rotational and vibrational analysis of the spectra obtained from the radiation emitted in the shock layer and in the free stream of the jet flow was performed, specifically, in the shock layer bands of the First Negative Group of ionized molecular nitrogen and in the free stream of the gamma-system of nitric oxide.

Blount, Charles E.↗

Spectroscopic data for an astronomy database

Very few of the atomic and molecular data used in analyses of astronomical spectra are currently available in World Wide Web (WWW) databases that are searchable with hypertext browsers. We have begun to rectify this situation by making extensive atomic data files available with simple search procedures. We have also established links to other on-line atomic and molecular databases. All can be accessed from our database homepage with URL: http:// cfa-www.harvard.edu/ amp/ data/ amdata.html.

Parkinson, W. H.↗

Research on Spectroscopy, Opacity, and Atmospheres

To make my calculations more readily accessible I have set up a web site cfaku5.harvard.edu that can also be accessed by FTP. it has 5 9GB disks that hold all of my atomic and diatomic molecular data, my tables of distribution function opacities, my grids of model atmospheres, colors, fluxes, etc, my program that are ready for distribution, most of my recent papers. Atlases and computed spectra will be added as they are completed. New atomic and molecular calculations will be added as they are completed. I got my atomic programs that had been running on a Cray at the San Diego Supercomputer Center to run on my Vaxes and Alpha. I started with Ni and Co because there were new laboratory analyses that included isotopic and hyperfine splitting. Those calculations are described in the appended abstract for the 6th Atomic Spectroscopy and oscillator Strengths meeting in Victoria last summer. A surprising finding is that quadrupole transitions have been grossly in error because mixing with higher levels has not been included. I now have enough memory in my Alpha to treat 3000 x 3000 matrices. I now include all levels up through n=9 for Fe I and 11, the spectra for which the most information is available. I am finishing those calculations right now. After Fe I and Fe 11, all other spectra are "easy", and I will be in mass production. ATL;LS12, my opacity sampling program for computing models with arbitrary abundances, has been put on the web server. I wrote a new distribution function opacity program for workstations that replaces the one I used on the Cray at the San Diego Supercomputer Center. Each set of abundances would take 100 Cray hours costing $100,000. 1 ran 25 cases. Each of my opacity CDs contains three abundances. I have a new program -iinning on the Alpha that takes about a week. I am going to have to get a faster processor or I will have to dedicate a whole workstation just to opacities.

Kurucz, Robert L.↗