Search NASA⌕ Search

SEARCH · Search NASA

Results for “atomic fountain”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Atomic fountain of laser-cooled Yb atoms for precision measurements

We demonstrate launching of laser-cooled Yb atoms in a cold atomic fountain. Atoms in a collimated thermal beam are first cooled and captured in a magneto-optical trap (MOT) operating on the strongly allowed {sup 1}S{sub 0}{yields}{sup 1}P{sub 1} transition at 399 nm (blue line). They are then transferred to a MOT on the weakly allowed {sup 1}S{sub 0}{yields}{sup 3}P{sub 1} transition at 556 nm (green line). Cold atoms from the green MOT are launched against gravity at a velocity of around 2.5 m/s using a pair of green beams. We trap more than 10{sup 7} atoms in the blue MOT and transfer up to 70% into the green MOT. The temperature for the odd isotope {sup 171}Yb is {approx}1 mK in the blue MOT, and reduces by a factor of 40 in the green MOT.

74 ATOMIC AND MOLECULAR PHYSICS↗

Robust Optimized Pulse Schemes for Atomic Fountain Interferometry

The robustness of an atomic fountain interferometer with respect to variations in the initial velocity of the atoms and deviations from the optimal pulse amplitude is examined. We numerically simulate the dynamics of an interferometer in momentum space with a maximum separation of and map out the expected signal contrast depending on the variance of the initial velocity distribution and the value of the laser field amplitude. We show that an excitation scheme based on rapid adiabatic passage significantly enhances the expected signal contrast, compared to the commonly used scheme consisting of a series of and pulses. We demonstrate further substantial increase of the robustness by using optimal control theory to identify splitting and swapping pulses that perform well on an ensemble average of pulse amplitudes and velocities. Our results demonstrate the ability of optimal control to significantly enhance future implementations of atomic fountain interferometry.

74 ATOMIC AND MOLECULAR PHYSICS↗

Flattening Earth acceleration in atomic fountains

A method to compensate for Earth's gravity tide over an extended axial region is reported. Flattening acceleration is important in experiments where the coupling of the dynamics of free-falling probes to the gravity gradient generates stochastic noise on the measurement. Optimized cylindrically symmetric mass distributions lower Earth's tidal effect over 10 cm by a factor 10{sup 3}. A multimass compensation system with comparable performance is devised for tall atom interferometers. Reducing the gravity gradient is essential in terrestrial experiments based on atom fountain configurations being developed to precisely test general relativity or the neutrality of matter.

74 ATOMIC AND MOLECULAR PHYSICS↗

Proposal of a truncated atomic beam fountain for reduction of collisional frequency shift

We propose an atomic fountain clock with a truncated cold atomic beam to achieve both a low collisional frequency shift and high frequency stability. In this clock, the launching velocity of a cold atomic beam can be swept to reduce the atomic density in the interrogation region for the Ramsey resonance and to increase the atomic density in the detection region. Before the top of the beam arrives at the interrogation region, the cold atomic beam is truncated by turning off the cooling laser beams to remove the unnecessary light shift. The atomic density in the interrogation region is theoretically evaluated to be 0.04 times that in an ordinary atomic fountain with optical molasses for the same number of detected atoms. The frequency stability limit due to quantum projection noise is calculated to reach 6.4x10{sup -14} in 1 s from the number of detected atoms while the fractional collisional shift is estimated to be {approx}{sup -}2x10{sup -16}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Feasibility Study of a Passive, Standoff Detector of High Density Masses with a Gravity Gradiometer Based on Atom Interferometry

For the emergency response (ER) and treaty verification communities, methods to determine and/or verify the masses present in containers are highly desirable. Additionally, the ability to perform these measurements passively and rapidly is also important in the ER community. The ability to quantify relevant masses and aspects of their spatial distribution is essential for setting lower bounds in relevant ER calculations and for monitoring treaty compliance. The purpose of this feasibility study was to demonstrate a completely passive, rapid method to determine the mass of high-density material present in a closed box, without the need to move, radiograph, or otherwise manipulate the box. Our method applies an existing, DARPA-AOSense, Inc. developed gravity gradiometer based on atomic fountain interferometer technology originally invented by Steven Chu and his team at Stanford, to perform differential gravity measurements, taken from positions around the container with the heavy mass sources inside. In this feasibility study, done with the AOSense gradiometer, we (equivalently) carried out the measurements by moving the mass source, in the required arrangements and orientations, parallel to the atomic fountain axis. We also built and applied computational models of the atomic fountain responses to our high-density mass sources and the background container to enable the blind determination of the overall masses and configurations of material present in the container in our experiments.

42 ENGINEERING↗

Atomic Interferometry with Detuned Counter-Propagating Electromagnetic Pulses

Atomic fountain interferometry uses atoms cooled with optical molasses to 1 μK, which are then launched in a fountain mode. The interferometer relies on the nonlinear Raman interaction of counter-propagating visible light pulses. We present models of these key transitions through a series of Hamiltonians. Our models, which have been verified against special cases with known solutions, allow us to incorporate the effects of non-ideal pulse shapes and realistic laser frequency or wavevector jitter.

42 ENGINEERING↗

Laser cooling of antihydrogen atoms

The photon—the quantum excitation of the electromagnetic field—is massless but carries momentum. A photon can therefore exert a force on an object upon collision 1 . Slowing the translational motion of atoms and ions by application of such a force 2,3 , known as laser cooling, was first demonstrated 40 years ago 4,5 . It revolutionized atomic physics over the following decades 6–8 , and it is now a workhorse in many fields, including studies on quantum degenerate gases, quantum information, atomic clocks and tests of fundamental physics. However, this technique has not yet been applied to antimatter. Here we demonstrate laser cooling of antihydrogen 9 , the antimatter atom consisting of an antiproton and a positron. By exciting the 1S–2P transition in antihydrogen with pulsed, narrow-linewidth, Lyman-α laser radiation 10,11 , we Doppler-cool a sample of magnetically trapped antihydrogen. Although we apply laser cooling in only one dimension, the trap couples the longitudinal and transverse motions of the anti-atoms, leading to cooling in all three dimensions. We observe a reduction in the median transverse energy by more than an order of magnitude—with a substantial fraction of the anti-atoms attaining submicroelectronvolt transverse kinetic energies. We also report the observation of the laser-driven 1S–2S transition in samples of laser-cooled antihydrogen atoms. The observed spectral line is approximately four times narrower than that obtained without laser cooling. The demonstration of laser cooling and its immediate application has far-reaching implications for antimatter studies. A more localized, denser and colder sample of antihydrogen will drastically improve spectroscopic 11–13 and gravitational 14 studies of antihydrogen in ongoing experiments. Furthermore, the demonstrated ability to manipulate the motion of antimatter atoms by laser light will potentially provide ground-breaking opportunities for future experiments, such as anti-atomic fountains, anti-atom interferometry and the creation of antimatter molecules.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atom Interferometry with up to 24-Photon-Momentum-Transfer Beam Splitters

We present up to 24-photon Bragg diffraction as a beam splitter in light-pulse atom interferometers to achieve the largest splitting in momentum space so far. Relative to the 2-photon processes used in the most sensitive present interferometers, these large momentum transfer beam splitters increase the phase shift 12-fold for Mach-Zehnder (MZ) and 144-fold for Ramsey-Borde (RB) geometries. We achieve a high visibility of the interference fringes (up to 52% for MZ or 36% for RB) and long pulse separation times that are possible only in atomic fountain setups. As the atom's internal state is not changed, important systematic effects can cancel.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Combined quantum-state preparation and laser cooling of a continuous beam of cold atoms

We use two-laser optical pumping on a continuous atomic fountain in order to prepare cold cesium atoms in the same quantum ground state. A first laser excites the F=4 ground state to pump the atoms toward F=3 while a second {pi}-polarized laser excites the F=3{yields}F{sup '}=3 transition of the D{sub 2} line to produce Zeeman pumping toward m=0. To avoid trap states, we implement the first laser in a two-dimensional optical lattice geometry, thereby creating polarization gradients. This configuration has the advantage of simultaneously producing Sisyphus cooling when the optical lattice laser is tuned between the F=4{yields}F{sup '}=4 and F=4{yields}F{sup '}=5 transitions of the D{sub 2} line, which is important to remove the heat produced by optical pumping. Detuning the frequency of the second {pi}-polarized laser reveals the action of a mechanism improving both laser cooling and state-preparation efficiency. A physical interpretation of this mechanism is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Free Space Ramsey Spectroscopy in Rubidium with Noise below the Quantum Projection Limit

In this work, we demonstrate the utility of optical cavity generated spin-squeezed states in free space atomic fountain clocks in ensembles of 390 000 87 Rb atoms. Fluorescence imaging, correlated to an initial quantum nondemolition measurement, is used for population spectroscopy after the atoms are released from a confining lattice. For a free fall time of 4 milliseconds, we resolve a single-shot phase sensitivity of 814(61) microradians, which is 5.8(0.6) decibels (dB) below the quantum projection limit. We observe that this squeezing is preserved as the cloud expands to a roughly 200 μ m radius and falls roughly 300 μm in free space. Ramsey spectroscopy with 240 000 atoms at a 3.6 ms Ramsey time results in a single-shot fractional frequency stability of 8.4(0.2) × 10 –12 , 3.8(0.2) dB below the quantum projection limit. The sensitivity and stability are limited by the technical noise in the fluorescence detection protocol and the microwave system, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measuring magnetic field vector by stimulated Raman transitions

We present a method for measuring the magnetic field vector in an atomic fountain by probing the line strength of stimulated Raman transitions. The relative line strength for a Λ-type level system with an existing magnetic field is theoretically analyzed. The magnetic field vector measured by our proposed method is consistent well with that by the traditional bias magnetic field method with an axial resolution of 6.1 mrad and a radial resolution of 0.16 rad. Dependences of the Raman transitions on laser polarization schemes are also analyzed. Our method offers the potential advantages for magnetic field measurement without requiring additional bias fields, beyond the limitation of magnetic field intensity, and extending the spatial measurement range. The proposed method can be widely used for measuring magnetic field vector in other precision measurement fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Femtosecond optical-to-microwave frequency divider with a relative instability of 10{sup −14}−10{sup −16}(τ=1−100 s)

We have developed a low-noise optical-to-microwave frequency divider based on a femtosecond erbium fibre laser. The source of an optical signal was a He−Ne/CH{sub 4} frequency standard. Comparison of two frequency dividers showed that the relative instability of output microwave signals, introduced by the dividers, is 10{sup −14}−10{sup −16} for the averaging time τ=1−100 s. The instability obtained corresponds to the requirements imposed on interrogative oscillators for time and frequency standards based on Cs or Rb atomic fountains. (letters)

42 ENGINEERING↗

Absolute Frequency Measurement of the {sup 40}Ca{sup +} 4s {sup 2}S{sub 1/2}-3d {sup 2}D{sub 5/2} Clock Transition

We report on the first absolute transition frequency measurement at the 10{sup -15} level with a single, laser-cooled {sup 40}Ca{sup +} ion in a linear Paul trap. For this measurement, a frequency comb is referenced to the transportable Cs atomic fountain clock of LNE-SYRTE and is used to measure the {sup 40}Ca{sup +} 4s {sup 2}S{sub 1/2}-3d {sup 2}D{sub 5/2} electric-quadrupole transition frequency. After the correction of systematic shifts, the clock transition frequency {nu}{sub Ca{sup +}}=411 042 129 776 393.2(1.0) Hz is obtained, which corresponds to a fractional uncertainty within a factor of 3 of the Cs standard. In addition, we determine the Landeg factor of the 3d{sup 2}D{sub 5/2} level to be g{sub 5/2}=1.200 334 0(3)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simultaneous differential measurement of a magnetic-field gradient by atom interferometry using double fountains

Precisely measuring the magnetic-field gradient within a vacuum chamber is important for many precision experiments and can be realized by atom interferometry using magnetically sensitive sublevels at different times to make a differential measurement, which had been demonstrated in our previous work. In this paper, we demonstrate a differential method to measure the magnetic-field gradient by means of two simultaneously operated atom interferometers using double atomic fountains. By virtue of this simultaneous differential measurement to reject common-mode noise, the resolution can be improved by one order of magnitude for about a 1000-s integration time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Creation of the first Russian time and frequency standard on a fountain of ultracold rubidium atoms

Technical specific features of the first Russian rubidium frequency standard of a fountain type are described, which are distinct from those of abroad analogues. Test results of separate systems and the metrological characteristics of the standard are presented. The achievable output frequency instability is 4 × 10{sup −16} per measurement interval of 24 hours and 1 × 10{sup −16} per 16 days. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Technique of pulsed optical pumping and pulsed excitation of microwave resonances using the Ramsey scheme in a {sup 87}Rb cell with a buffer gas

A laboratory prototype of a compact quantum frequency standard based on a rubidium vapour cell with pulsed laser pumping is developed. With significantly smaller overall dimensions (a volume of ∼10 L and a mass of ∼10 kg), the frequency standard is expected to have the short-term instability comparable with that of the commercial passive hydrogen masers and even the laboratory fountain-type atomic clocks based on cold atoms. The advantages of the technique of pulsed optical pumping and pulsed excitation of microwave resonances over the traditional techniques of double radio-optical resonance detection are substantiated. The results of the experimental study of pulsed optical pumping of a rubidium cell with a mixture of buffer Ar – Ne gases implemented at the VNIIFTRI are presented, the Ramsey resonances are obtained, and the process of optimising the contrast of the central resonance peak is described. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The application of Raman laser in gravity measurement and metrology

Atom Interferometry is proved to be a potential method for measuring the acceleration of atoms due to Gravity, we are now building a feasible system of cold atom gravimeter, it is based on the atom interferometry technology by coherently manipulating the cold atoms in a fountain (with a height of 1m) with specific Raman lasers, the cold atom wave packet is splitted, combined, and then re-splitted in the process. Then the atomic wave packet will acquire different phase because of the different evolution path. The precise acceleration can be deduced through the precision measurement of atomic interference fringes phase, and this will be a high precision standard of acceleration. At present, the preparation of Raman laser and the precise control of the laser Frequency have been finished, and they have been proved to meet the requirements of the experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗