Search NASA⌕ Search

SEARCH · Search NASA

Results for “auxiliary power units”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Optimal management of electric hotel loads in mild hybrid heavy duty truck

Here, the problem of engine idling for heavy-duty trucks has been under study for decades with Auxiliary Power Units (APUs) and Truck Stop Electrification (TSE) as the most compelling solutions. With the electrification of trucks approaching feasibility in terms of cost-effective technology, hybridization offers another “degree of freedom” to tackle the problem. Here, this work aims at exploiting a battery pack of a 48 V mild-hybrid heavy-duty truck to store sufficient onboard energy for powering the auxiliary loads during the hoteling. This problem is not trivial, as the battery packs typically cannot recover the entire energy required through regeneration alone; hence an optimal energy management strategy needs to be employed to charge the battery through the engine during drive operation. This strategy optimizes powertrain performances among the four modes: (i) Engine of Coasting (EOC), (ii) Regeneration by braking, (iii) Regeneration by engine, and (iv) engine idling. This paper presents the development of a Dynamic Programming (DP) framework that employs a multi-objective cost function to minimize the fuel consumption and maximize the regeneration using the above-mentioned four modes. A typical heavy-duty truck drive cycle is used to represent the drive phase, with mandatory hoteling stops as per regulations. A comprehensive powertrain model is developed using validated components’ model. The DP employs two state variables: battery State-of-Charge (SOC) and engine mode, and three control inputs: (i) the engine ON–OFF state, (ii) clutch engagement state, and (iii) power request at the Electric Machine (EM) for calculating optimal SOC trajectory. The framework also tackles rapid engine ON–OFF scenarios to avoid the challenges associated with DP and the compromises in fuel cost with those approaches. Finally, the effectiveness of the proposed framework is tested for potential fuel savings on two different battery packs by performing the full cycle simulations. The results show 6.47% of fuel consumption reduction as compared to traditional APU-based heavy-duty truck.

33 ADVANCED PROPULSION SYSTEMS↗

Machine learning-guided design of direct methanol fuel cells with a platinum group metal-free cathode

Direct methanol fuel cells (DMFCs) offer a promising solution for clean electricity generation, particularly in small electronics and remote auxiliary power units. However, optimizing their efficiency and performance is challenging due to the complex interactions between various factors. Here, we present a novel approach that integrates experiments with machine learning to model and predict the performance of these fuel cells using atomically dispersed platinum group metal (PGM)-free catalysts at the cathode. Further, our machine learning models, trained on diverse input parameters, allow for the comprehensive optimization of DMFC performance prior to fabrication and testing. Through extensive experimental validation, we demonstrate that this data-driven approach accurately predicts key performance metrics, such as maximum power output and polarization curves. By combining our models with interpretable game-theory methods, we provide deep insights into the factors governing fuel cell performance, ultimately paving the way for the design of scalable and efficient DMFC technologies.

25 ENERGY STORAGE↗

Metal-Supported Ceria Electrolyte-based SOFC Stack for Scalable, Low-Cost, High-Efficiency and Robust Stationary Power Systems (Final Report)

This is the end of project report for the DOE Project DE-FE-0027844 “Metal-Supported Ceria Electrolyte-based SOFC Stack for Scalable, Low-Cost, High-Efficiency and Robust Stationary Power Systems”. The objectives of the project were to develop several technologies required for the mass adoption of Solid Oxide Fuel Cell systems for medium to large power generation applications. The key achievements of this project were: 1) Development of fuel cells with complete internal fuel reforming capability. 2) Fuel cell power scale up with production of cells with larger active areas. 3) Assembly of an integrated 5 kW modular stack platform capable of installation into medium to large power systems. 4) Demonstration of a 10 kW Fuel Cell Power System utilizing the integrated 5 kW modular stack platform. 5) Cost modelling to show system cost of $1,500/kW are achievable at production volumes. 6) Development of cathode air poison getters for reduced degradation and extended fuel cell life. 7) Assessment of fuel poison on anode degradation, particularly poisons frequently produced from the process of gasification of coal. The Cummins led Voice of Customer (VOC) work identified several significant markets for natural gas powered fuel cell systems, where the end customer is interested in reducing energy consumption and emissions, or increasing reliability of electrical supply. Data centers and truck Auxiliary Power Units (APU) were highlighted as 2 key future markets for fuel cell systems.

30 DIRECT ENERGY CONVERSION↗

High Performance Metal-Supported SOFC System for Range Extension of Commercial Aviation

The DOE ARPA-E REEACH program [1] has enabled this Phase 1 study that conceptualizes a commercial 154 passenger electric aircraft using renewable aviation fuel for range extension while meeting similar mission performance levels as current commercial aircraft. Commercial aviation accounts for about 2.5% of global CO2 emissions, and close to 5% of overall anthropogenic climate change due to the added accounting of contrail’s effects [2]. The sector has adopted a goal of carbon neutrality by 2050 [3]. 110 nations, and recently the new US administration, have embarked on work to address this important challenge. The US DOE has released a roadmap to enable the further development of sustainable aviation fuel (SAF) in the hopes that it could meet all of aviation’s fuel needs by 2050 [4]. However, SAF fuel price and sufficient future feedstock availability remains a concern [5]. Considering the first commercial biofuel flight demonstration 14 years ago [6] and that SAF still only comprises less than 0.1% of jet fuel use, the question arises as how it can ramp up to 100% use in the next 27 years. One option that has the potential to substantially reduce the need for SAF is to implement light-weight Solid Oxide Fuel Cells (SOFCs) that can efficiently utilize SAF or other sulfur-free hydrocarbon fuels. As opposed to lower temperature PEM (Proton Exchange Membrane) fuel cells that can use high-purity hydrogen, SOFC’s fuels are very flexible, ranging from low cost liquefied natural gas (LNG), renewable liquefied natural gas (RLNG), to SAF, to generate clean electrical power for use in aviation propulsion and auxiliary power units [7] [8]. Research progress is needed to enable SOFCs to achieve 3.0 kW/kg power density, making them viable for aviation [9]. The DOE’s Advanced Research Projects Agency – Energy (ARPA-E) has therefore initiated an aviation SOFC R&D program that is anticipated to dramatically reduce aircraft fuel use though the implementation of “Range Extenders for Electric Aviation with low Carbon and High efficiency” (REEACH) [1] for medium range commercial aircraft. This report summarizes the progress during phase 1 of the REEACH program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Fidelity Heavy-Duty Vehicle Modeling Using Sparse Telematics Data

Heavy-duty commercial vehicles consume a significant amount of energy due to their large size and mass, directly leading to vehicle operators prioritizing energy efficiency to reduce operational costs and comply with environmental regulations. One tool that can be used for the evaluation of energy efficiency in heavy-duty vehicles is the evaluation of energy efficiency using vehicle modeling and simulation. Simulation provides a path for energy efficiency improvement by allowing rapid experimentation of different vehicle characteristics on fuel consumption without the need for costly physical prototyping. The research presented in this paper focuses on using real-world, sparsely sampled telematics data from a large fleet of heavy-duty vehicles to create high-fidelity models for simulation. Samples in the telematics dataset are collected sporadically, resulting in sparse data with an infrequent and irregular sampling rate. Captured in the dataset was geospatial information, time series measurements, and vehicle-specific metadata from a subset of 96 vehicles from varied geographic regions across North America. A series of custom algorithms was developed to process vehicle data and derive both vehicle model input parameters and representative drive cycles. Derived models provide a basis on which to simulate real-world vehicles and iterate on vehicle aerodynamics, auxiliary power loads, transmission shift schedules, and other parameters to achieve reduced fuel consumption and increase energy efficiency. Notably, these models were developed without the use of expensive field data collection, using only data collected through fleet telematics. Processed representative drive cycles are used to validate the fuel economy of derived models. The models developed through this research allow for more representative vehicle simulations with increased flexibility regarding vehicle-to-vehicle variations.

ADVANCED PROPULSION SYSTEMS↗

Improving operational flexibility of integrated energy system with uncertain renewable generations considering thermal inertia of buildings

Insufficient flexibility in system operation caused by traditional "heat-set" operating modes of combined heat and power (CHP) units in winter heating periods is a key issue that limits renewable energy consumption. In order to reduce the curtailment of renewable energy resources through improving the operational flexibility, a novel optimal scheduling model based on chance-constrained programming (CCP), aiming at minimizing the lowest generation cost, is proposed for a small-scale integrated energy system (IES) with CHP units, thermal power units, renewable generations and representative auxiliary equipments. In this model, due to the uncertainties of renewable generations including wind turbines and photovoltaic units, the probabilistic spinning reserves are supplied in the form of chance-constrained; from the perspective of user experience, a heating load model is built with consideration of heat comfort and inertia in buildings. To solve the model, a solution approach based on sequence operation theory (SOT) is developed, where the original CCP-based scheduling model is tackled into a solvable mixed-integer linear programming (MILP) formulation by converting a chance constraint into its deterministic equivalence class, and thereby is solved via the CPLEX solver. We report the simulation results on the modified IEEE 30-bus system demonstrate that the presented method manages to improve operational flexibility of the IES with uncertain renewable generations by comprehensively leveraging thermal inertia of buildings and different kinds of auxiliary equipments, which provides a fundamental way for promoting renewable energy consumption.

30 DIRECT ENERGY CONVERSION↗

Non-catalytic pyrolysis of associated gas to zero CO 2 hydrogen and high value carbon black

The overall objective of this work is to perform a pre-Front End Engineering Design (pre-FEED) study of the conversion of associated gas produced at an active oil pad of a Bakken oil field producer, to high value carbon black and hydrogen using the Microwave Plasma Pyrolysis of Associated Gas (MPP-AG) process developed by H Quest Vanguard, Inc (HQV). The University of North Dakota’s Center for Process Engineering Research (CPER) collaborated with HQV to complete a design and techno-economic analysis for the MPP-AG deployed at an active Bakken well site flaring an average of 54,000 standard cubic feet per day of AG. The proposed design consists of: • A Microwave Pyrolysis Unit (MPU) which consists of H Quest’s proprietary MPP technology • A patent-pending Gas Conditioning Unit (GCU) designed by the University of North Dakota to condition intermittent and variable flow gas prior to pyrolysis. • An auxiliary unit running on the associated gas to power the GCU and MPU in an “island mode” configuration.

03 NATURAL GAS↗

Time-dependent scenario modeling for the ST-E1 fusion power plant

ST-E1 is a low aspect ratio fusion power plant being designed by Tokamak Energy targeting 1.5 GW of fusion power. Characterization of the ST-E1 flat-top scenario is described elsewhere McNamara et al (2026 Nucl. Fusion 66 086008); here we focus on addressing the question of how to ramp-up the ST-E1 plasma from an initial state following breakdown and flux-surface formation to the target flat-top state. Being low-aspect ratio, the available solenoid flux of ST-E1 is limited. Therefore, particular consideration is placed on developing ramp-up scenarios that predominantly use inductive flux provided by external vertical field coils. Through time-dependent modeling with METIS, we show that this is possible when the ramp-up is performed at relatively high plasma density: although auxiliary current drive efficiency is reduced, this is significantly outweighed by (1) higher electron-ion collisional equilibration, (2) higher fusion power once ions become sufficiently hot, (3) higher poloidal beta for increased vertical-field flux, and (4) potentially favorable exhaust compatibilities. Ultimately, we show the target ST-E1 flat-top performance can be reached after a ramp-up period lasting 150 s using less than 40 Vs of solenoid flux (with vertical field providing ∼ 90 Vs of flux). The sensitivity to model assumptions are presented, with the general observation that deleterious effects can be mitigated through minor alterations of the auxiliary power temporal waveform and/or total auxiliary power level. The impact of a solenoid and the auxiliary power mix (electron cyclotron heating only versus electron and ion cyclotron heating) on the ST-E1 ramp-up success are also discussed in appendices. On this latter topic, we show that the effect of direct-ion heating during ramp-up is obscured by the uncertainty in the pedestal dynamics, identifying a clear line of future work required to make a definite decision on the ST-E1 auxiliary power mix.

current ramp-up↗

Experiences with Mobile Units for Liquid RAW Management in Slovak and Czech Nuclear Power Plants - 20089

In Nuclear Power Plants VVER 440, Russian type of reactor there was designed auxiliary building where according to basic design all operational liquid radioactive waste (RAW) should be stored in large capacity tanks during the whole operational period. That's why there are in the auxiliary building several types of large storage tanks with different internal volume from 110 m{sup 3}, 460 m{sup 3} to 550 m{sup 3}. Storage tanks are usually situated in rooms with limited access and minimal handling space. Operational waste was here transported by the system of pipes from the reactor building. There is possibility to handle with the waste and set the pipeline in to the chosen storage tanks. Nobody takes care about the quality of waste in the storage tanks and waste waits for the period of decommissioning when it should be treated. The storage capacity was designed for the whole lifetime of nuclear power plant. Currently the life time of Nuclear Power Plant's (NPP) is extended and there is necessity to retrieve and treat the RAW in advance. Another reason why the stakeholder, who operates the NPPs, decides to treat the operational RAW during the operational period of NPP, is that there are still new requirements from safety point of view which need to have free available space for example because of potential accident. So treating the operational RAW during the life time of NPP is present issue. Because in basic design nobody cares how the RAW will be retrieved and treated in the future, there is usually no technology for that in existing NPP. Some of the NPPs build an additional building with suitable technologies for treatment or hire the company which offer mobile technology for retrieving the waste from the storage tanks. Wood Nuclear Slovakia PLC provides all activities within liquid RAW management projects by its own staff including management, design, construction and deployment of equipment, engineering support, as well as all RAW retrieval and solidification activities. We offer RAW management as a service without any significant changes in existing NPP's buildings and technology. It is always a technical challenge to conduct successful retrieval, pumping and treatment of RAW. The complex RAW retrieval system can be designed as tailored solution for any RAW storage according to known boundary conditions and specific needs. These systems are based on years of experience with RAW manipulation, processing and treatment and the whole RAW management knowledge by Wood Nuclear Slovakia LTD. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Minimizing Auxiliary Heat Use for Cold Climate Operation of Air-Source Heat Pumps

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climate conditions. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in northwest United States and one in Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five-seconds, to calculate heat pump's capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides valuable insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving the overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Minimizing Auxiliary Heat Use for Cold Climate Operation of Air Source Heat Pumps: Preprint

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climates. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in the northwest United States and one in a Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five seconds, to calculate the heat pump’s capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computational Algorithms for Unit Commitment with AC Power Flows (Final Report)

Security-constrained unit commitment (SCUC) is a key component in power system operations. When AC power flow constraints are considered in the SCUC model (AC-SCUC), the problem becomes extremely difficult due to its discrete and non-convex nature, as described in “Grid Optimization Competition Challenge 3 Problem Formulation (GOCC)”. There are four main challenges: (i) Discrete decisions regarding unit online/offline status and start-up/shut-down procedures for every single unit. The number of discrete decision variables increases considerably when a system integrates multiple generators; (ii) Configuration-based combined-cycle formulations, and multi-commodity models that include ramping products, spin/non-spin products, and regulation up/down products. The combined-cycle units introduce additional discrete decision variables and auxiliary service products further complicate the model by connecting multi-commodity products’ continuous and discrete variables; (iii) SCUC models with AC power flow constraints are far more complex due to massive bilinear terms in the large-scale nonlinear power balance equations. The nonlinear power balance equations are further complicated by the discrete step control variables of shunts; (iv) N − 1 contingency analysis. The size of the model increases linearly with the number of contingencies considered, greatly increasing the size of the optimization model. Accordingly, there is an emergent need to develop a robust algorithm capable of deriving a high-quality solution in a short time and passing through contingency tests simultaneously. In this project, we explore innovative techniques to address this challenging problem by integrating advanced polyhedral theory, approximation methods, relaxation strategies, decomposition techniques, and parallel computing. Each technique approaches the problem from a different perspective, leveraging its specific strengths to tackle distinct challenges. Each individual method has demonstrated its effectiveness in the PI’s previous research. Their integration is expected to significantly reduce the computational time required to solve the proposed complex problem. Successful completion of this project has the potential to transform the industry by enhancing optimization solvers capable of handling large-scale day-ahead energy market clearing models within strict time constraints, while incorporating AC power flow constraints. This advancement will lead to reduced overall generation costs and, consequently, increased social welfare.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Requirements for Integration of Nuclear Reactors with Iron and Steel Plants

This report identifies energy needs of heavy energy users within the domestic iron and steel industry and suggests solutions for integrating nuclear energy. The iron and steel industry, composed of several types of plants which perform different processes with varied energy demands and vectors, is a heavy consumer of electric power and fossil fuels including coke and natural gas. Almost all major process temperatures exceed the temperatures of direct heat available from advanced reactors, and so electricity and hydrogen were considered instead. Reference units were adopted and estimated energy demands computed for the blast furnace (BF), direct reduced iron (DRI) unit, electric arc furnace (EAF), and reheat furnaces. By utilizing production capacity data from industry reports, the ranges of power demands were estimated, including for hydrogen production by high temperature steam electrolysis (HTSE). For the EAF and DRI unit, more detailed integration studies with thermodynamic modeling were also conducted and determined a possible solution with a specific reactor design and number of modules. Furthermore, because many unit processes are co-located, entire plants were considered by adding the energy demands of the unit processes to form four hypothetical reference plants. The range of power needs for the reference plants is compatible with multi-unit banks of microreactors at the low end, and would create a need for multiple larger-capacity SMRs at the high end (1 GWe plus 0.14 GWt). Although the overall power need at the high end is well-matched with one present-day large reactor offering (1.1 GWe), redundancy considerations may require a minimum of two reactors, potentially eliminating the single large reactor from consideration. Auxiliary or house loads would increase the reference plant estimates. Finally, the report provides total estimated energy needs under integration of all U.S. units of each process (BF, DRI, EAF, and reheat furnaces), representing a national potential for nuclear energy in the industry. U.S. iron and steel plants may be candidates for integration with nuclear reactors via electricity and hydrogen, and many sites have energy requirements that correspond well to the capacities of several advanced nuclear power designs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

System Study: Auxiliary Feedwater 1998-2024

This report presents an unreliability evaluation of the auxiliary feedwater (AFW) system at 62 U.S. commercial operating nuclear reactors. New Standardized Plant Analysis Risk (SPAR) models with the most recent SPAR parameter update results were used in this report. Demand, run hour, and failure data from calendar years 1998 to 2024 for selected components were obtained from the Institute of Nuclear Power Operations Industry Reporting and Information System. The unreliability results are trended for the most recent 10 year period and yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the industry-wide estimates of AFW system start-only unreliability, but a statistically significant decreasing trend was identified in the industry-wide estimates of AFW system 24-hour mission unreliability.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of Carbon Molecular Sieves Hollow Fiber Membranes based on Polybenzimidazole Doped with Polyprotic Acids with Superior H 2 /CO 2 Separation Properties (Final Report)

The goal of this project was to develop a highly efficient membrane-based process to capture CO 2 from coal-derived syngas with 95% CO 2 purity, achieving the cost of electricity (COE) 30% below the baseline capture approaches (i.e., Selexol process) when coupled with the advancement in other areas of the power generation facility. Our core approach is based on high-permeance hollow fiber membranes (HFMs) with superior H 2 /CO 2 separation properties at the syngas process conditions, which can then be further utilized to design membrane reactors for process intensification of H 2 production and purification and CO 2 capture. Three organizations with complementary skills collaborated to achieve the goal, including the University at Buffalo (UB), Los Alamos National Laboratory (LANL), and Trimeric Corporation (Trimeric). We formulated logical steps to bring the membrane technology from Technology Readiness Level (TRL) 3 (Experimental proof of concept) to TRL 4 (Laboratory scale validation in relevant environment). During the budget period (BP) 1, we screened various polymeric materials and identified polybenzimidazole doped with inorganic polyprotic acids as the desirable platform. The acid doping increases the H 2 /CO 2 selectivity, and the sequential carbonization increases H 2 permeability while retaining the high selectivity. By manipulating the acid type and doping level and the carbonization temperature, we demonstrated advanced carbon molecular sieving (CMS) materials with H 2 permeability of above 200 Barrer (1 Barrer = 10 -10 cm 3 (STP) cm cm -2 s -2 cmHg -1 ) and H 2 /CO 2 selectivity of above 40 at 200-300°C with simulated syngas containing CO and water vapor. For example, the PBI-(H 3 PO 4 ) 0.11 carbonized at 700 °C exhibits H 2 permeability of 200 Barrer and H 2 /CO 2 selectivity of 60 at 200 °C, and H 2 permeability of 240 Barrer and H 2 /CO 2 selectivity of 54 at 225 °C, which meets the targeted properties and surpasses Robeson’s upper bound. During the BP2, we focused on the conversion of the advanced CMS materials to stable HFMs. Membranes with H 2 permeance of 1,090 GPU (1 GPU = 10 -6 cm 3 (STP) cm -2 s -2 cmHg -1 ) and H 2 /CO 2 selectivity of 57 at 300 °C were successfully fabricated. The effects of temperature, gas compositions, pressure, and time on the separation properties were systematically investigated. Pencil modules were continuously evaluated for 219 h (dry pure gas) and 669 h (dry simulated syngas) and showed initial decline in permeance and increased H 2 /CO 2 selectivity over time, ultimately achieving a steady state stable value, indicating that the ageing phenomena in the nanoporous structures of the membranes during the test. Membrane reactors were fabricated based on the CMS membranes and evaluated for water-gas shift (WGS) reaction. The use of membranes slightly improves the conversion of the CO. However, parametric tests of the membrane reactors at various temperatures and flow rates need to be conducted, as well as the membranes with improved separation performance. We performed a sensitivity analysis on the impact of H 2 /CO 2 selectivity on the COE based on a hybrid process of a membrane unit and cryogenic unit developed by Membrane Technology and Research, Inc. (MTR). Three H 2 /CO 2 selectivity (40, 60, and 15) cases were developed and compared with the baseline capture process (Case B5B) provided by the DOE report. Increasing the membrane H 2 /CO 2 selectivity reduces COE, but the rate of the decrease of COE also diminishes. The COE values for H 2 /CO 2 selectivities of 40 and 60 were nearly the same. As the H 2 /CO 2 selectivity increases, the inert recycling decreases, leading to smaller equipment, less auxiliary power requirements, and less heating, cooling, and refrigeration duty. The refrigeration system used to liquefy the CO 2 is the most expensive piece of equipment and consumes the most electricity within the CO 2 capture process. Increasing the CO 2 concentration in the recycle stream would improve the economics of the process by reducing the refrigeration duty requirement of the unit and also allow for higher liquefaction temperatures. The high H 2 -selective membrane developed by our team may be applicable in other separation processes where lower pressure H 2 retains value. Typically, hydrogen retains its pressure when it is separated from syngas components. Residual components may be used as low-quality fuel and then vented to the atmosphere. Applications might include control of H 2 /CO ratios or mitigation of the water gas shift reaction by CO 2 recycling to the feed of a gasifier or steam methane reformer. To summarize, we have developed industrial HFMs with the best H 2 /CO 2 separation performance reported in the literature. The membranes demonstrate stability with simulated syngas and show great potential for membrane reactors for WGS reactions, lowering the cost of blue H 2 production.

20 FOSSIL-FUELED POWER PLANTS↗

Hydrogen Contamination Detector: Protecting the future of zero-emission fuel cell energy [Brief]

Los Alamos National Laboratory developed an electrochemical detector to protect zero-emission hydrogen fuel cells from contaminated fuels. Fuel cells power environmentally clean vehicles, fork lifts, drones, and provide auxiliary power. High-purity hydrogen is essential to avoid poisoning fuel cells. Current analysis methods are costly and cannot detect impurities in realtime. The Hydrogen Contamination Detector measures the two highest impact Department of Energy-identified impurities with a simple, low-cost unit that provides 24/7, point-of-service analysis. Los Alamos partnered with H2Frontiers to conduct field trials at hydrogen refueling stations and with Skyre LLC for commercialization through a DOE Technology Commercialization Fund project.

08 HYDROGEN↗

High-Performance Semiempirical Excited-State Molecular Dynamics Powered by Graphics Processing Units

Here, this Letter introduces excited-state molecular dynamics in PYSEQM, a GPU-accelerated semiempirical quantum chemistry engine implemented in PyTorch. The new module enables Born–Oppenheimer molecular dynamics (BOMD) using configuration-interaction singles and random phase approximation for excited states, allowing long trajectories and large statistical ensembles to be simulated efficiently on a single GPU. We also implement an extended Lagrangian excited-state BOMD (XL-ESMD) scheme that propagates auxiliary electronic variables, enabling relaxed ground and excited-state convergence thresholds without compromising energy conservation. The excited-state BOMD implementation scales smoothly from small chromophores to a nearly 900-atom dendrimer (taking 6.5 s per MD step). PYSEQM also supports batched execution, allowing many geometries or trajectories to be evaluated in a single GPU launch, substantially increasing throughput and making ensemble-based protocols routine. As a demonstration, we compute absorption, emission, and infrared spectra from trajectories propagated on the ground and first excited states. The XL-ESMD scheme yields identical spectra at significantly lower computational cost, establishing the role of extended Lagrangian based dynamics for efficient excited-state BOMD simulations. Beyond raw performance, PYSEQM’s PyTorch foundation provides automatic differentiation for forces, efficient GPU batching, and seamless interfacing with machine learning models. These capabilities position PYSEQM as a practical platform for machine learning-augmented excited-state dynamics and lay the foundation for future data-driven nonadiabatic excited-state dynamics modeling of ultrafast spectroscopic probes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessing Geospatial and Seasonal Influences on Energy and Cost-Efficiency of Drayage Trucks

The electrification of heavy-duty vehicles is a critical pathway toward improved energy efficiency in the freight sector. The current battery electric truck technology poses several challenges to commercial vehicle operations, such as limited driving range, sensitivity to climate conditions, and long recharging times. Estimating the energy consumption of heavy-duty electric trucks is crucial to assessing the feasibility of fleet electrification and its impact on the electric grid. This article focuses on developing a model-based simulation approach to predict and analyze the energy consumption of electric trucks by considering the impact of weather and geographical conditions on vehicle road load and auxiliary components power consumption, as well as the impact these factors have on driving range. Specifically, drayage trucks employed in logistics around maritime ports are used as a case study, with consideration of seasonal climate variations and geographical characteristics at different locations. The article includes results for three major container ports within the United States, providing region-specific insights into the energy requirements and driving range of the electric drayage trucks in these regions, which will inform decision-makers in integrating electric trucks into the existing drayage operations and plan investments for electric grid development.

Sujan, Vivek [ORNL] (ORCID:0000000269882342)↗