At least 19 records

Design and modeling of indirectly driven magnetized implosions on the NIF

The use of magnetic fields to improve the performance of hohlraum-driven implosions on the National Ignition Facility (NIF) is discussed. The focus is on magnetically insulated inertial confinement fusion, where the primary field effect is to reduce electron-thermal and alpha-particle loss from the compressed hotspot (magnetic pressure is of secondary importance). We summarize the requirements to achieve this state. The design of recent NIF magnetized hohlraum experiments is presented. These are close to earlier shots in the three-shock, high-adiabat (BigFoot) campaign, subject to the constraints that magnetized NIF targets must be fielded at room-temperature, and use ≲1 MJ of laser energy to avoid the risk of optics damage from stimulated Brillouin scattering. We present results from the original magnetized hohlraum platform, as well as a later variant that gives a higher hotspot temperature. In both platforms, imposed fields (at the capsule center) of up to 28 T increase the fusion yield and hotspot temperature. Integrated radiation-magneto-hydrodynamic modeling with the Lasnex code of these shots is shown, where laser power multipliers and a saturation clamp on cross-beam energy transfer are developed to match the time of peak capsule emission and the P2 Legendre moment of the hotspot x-ray image. The resulting fusion yield and ion temperature agree decently with the measured relative effects of the field, although the absolute simulated yields are higher than the data by 2.0−2.7×. The tuned parameters and yield discrepancy are comparable for experiments with and without an imposed field, indicating the model adequately captures the field effects. Self-generated and imposed fields are added sequentially to simulations of one BigFoot NIF shot to understand how they alter target dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Guideline for Characterizing and Evaluating a Candidate Project Site for Solar Thermal Applications

This document presents a structured procedure for characterizing and evaluating candidate project sites for concentrating solar power (CSP) and solar heat for industrial processes (SHIP) applications. The objective is to provide project developers, researchers, and other stakeholders with a consistent, technology-agnostic framework for early-stage site assessment, enabling informed decision-making prior to significant investment in project development. Site selection is a critical factor in project success or failure for both CSP and SHIP projects. Key factors such as solar resource availability, land characteristics, environmental and regulatory constraints, infrastructure availability, and community context are determined by the choice of project site and can materially impact project performance, cost, schedule, and overall viability. This procedure is designed to systematically evaluate these factors, identify potential fatal flaws, and prioritize the most favorable candidate sites for further development. The process begins with rapid screening-level evaluation, using publicly available data to assess solar resource, land availability and suitability, zoning and land-use compatibility, and exclusion zones such as protected lands or sensitive habitats. Sites that meet the minimum screening criteria advance to a more detailed characterization. Subsequent sections of this report provide guidance for a next-level assessment of the most important technical and environmental parameters, including: 1) Solar resource quality, variability, and uncertainty using multiyear datasets and, where appropriate, on-site measurement campaigns; 2) Meteorological conditions such as wind, temperature, extreme weather events, and soiling impacts; 3) Land characteristics including slope, shading, and geotechnical conditions; and 4) Environmental and regulatory considerations, including permitting processes, endangered species, cultural resources, and visual impacts. The procedure also addresses infrastructure and integration considerations, including: 1) Grid interconnection requirements for CSP power generation projects; 2) Electrical and operational integration for SHIP facilities; 3) Water availability, quality, and permitting constraints, which are particularly critical for CSP in arid regions; and 4) Site access, construction logistics, and availability of workforce and supporting services. Recognizing the importance of social and economic context, the procedure includes evaluation of community engagement factors, such as stakeholder sentiment, proximity to sensitive visual receptors, workforce development opportunities, and local economic incentives. The outputs of these assessments are synthesized in a cost and risk evaluation, translating site characteristics into expected impacts on capital cost, operating cost, schedule, and technical risk. This is complemented by screening-level performance modeling, including 8760 simulations and long-term projections, to quantify expected energy or thermal output, assess variability thereof, and support comparison between candidate sites. Finally, the procedure provides high-level guidance on a structured go/no-go decision framework, categorizing sites based on identified risks and constraints, and outlining a clear path forward to feasibility studies and front-end engineering design for viable projects. By standardizing the site characterization process across both CSP and SHIP applications, this guideline aims to: 1) Improve consistency and transparency in early-stage project evaluation; 2) Reduce development risk and avoid investment in nonviable project sites; 3) Support collaboration between developers, researchers, and public agencies; and 4) Accelerate successful deployment of concentrating solar technologies for both power generation and industrial process heat.

14 SOLAR ENERGY↗

Marine Toxicity, Biodegradability, and Rolling-Sliding Tribological Performance of Ionic Liquid-Enhanced Environmentally-Acceptable Lubricants for Tidal Turbomachinery

Environmentally acceptable lubricants (EALs) are increasingly being recognized in many fields including waterpower, hydraulics, water transport, agricultural machinery, offshore wind turbines, etc. Specifically, high-performance EALs are demanded for tidal turbomachinery to ensure high efficiency and reliability and avoid the significant risk of direct contamination of the marine ecosystem upon leaks. Here we report a new development of ionic liquid (IL)-enhanced EALs for tidal energy. One short-chain phosphonium phosphate and one short-chain ammonium phosphate ILs were used as the candidate additives and the IL-containing EALs demonstrated significantly improved lubricating performance, much lower toxicity, and increased biodegradability compared with commercial baselines. Specifically, in a rolling-sliding test simulating the operation of a model tidal turbine gearbox bearing, an EAL containing the ILs at a 0.5 wt % concentration demonstrated 40% lower friction, 45% less wear loss, substantially reduced rolling contact fatigue-induced surface damage, and one order of magnitude lower vibration noise compared with a commercial gear oil. In an EPA standard toxicity test, 90 and 70% survival of marine biota was observed when exposed to an EAL containing 5 wt % of the short-chain phosphonium phosphate and ammonium phosphate ILs, respectively, while the selected commercial gear oil and bioderived additive killed all marine biota. In a standard biodegradability test, 2 wt % addition of the phosphonium phosphate IL not only retained the EAL’s ready biodegradability but further boosted the oil decomposition from a range of 60–80% to a higher level of 80–95%. Conversely, adding the commercial bioderived additive downgraded the EAL from readily to inherently biodegradable. Furthermore, this work offers scientific insights for development of ILs as potential EAL additives for marine energy and broader applications.

additives↗

A Review of Online Monitoring within Used Nuclear Fuel Recycling Processes

The processing of used nuclear fuels and related materials is often complex and variable. The ability to quickly optimize conditions to the material being processed can aid in increasing efficiency and safety, but requires very quick determination of the conditions present in the feedstock, the process, and the product. Furthermore, accurate quantification of materials such as enriched uranium and plutonium aids in maintaining material accountancy and avoiding nuclear proliferation risks. Traditional analytical methods require process samples to be collected and analyzed in a laboratory, which often takes days to weeks. Online monitoring is suitable for collecting this information nearly instantaneously, enabling much faster optimization of the process or detection of material diversion. Online monitoring is also beneficial as it is typically based on robust and nondestructive analytical methods, so no material is removed as samples. This review examines online monitoring relevant to used nuclear fuel processing for the determination of both chemical and physical parameters. The chemical parameters include quantities such as concentration, isotopic composition, and speciation. These values are often well suited to spectroscopic or spectrometric measurements as they are fast, nondestructive, and easily implemented in an online manner. Physical quantities are often more varied and include temperature, pressure, tank fill levels, and others. Due to the specificity of these quantities, specialized instrumentation is often used. However, this instrumentation is often amendable to online monitoring.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Molten Salt Loop Operational Experience and Test Campaigns in FY24

The Facility to Alleviate Salt Technology Risks (FASTR) at the US Department of Energy (DOE) Oak Ridge National Laboratory (ORNL) was developed to demonstrate technology for high-temperature chloride salt systems (Figure 1). FASTR is primarily constructed using alloy C-276 and is designed to operate at temperatures of up to 725°C. The facility is loaded with 250 kg of NaCl-KCl-MgCl 2 salt. This salt provides a relevant test environment for de-risking technology while avoiding the costs and hazards associated with beryllium-based or uranium-bearing salts. The facility’s major components include a centrifugal pump for salt circulation, an air-based heat exchanger to reject heat, a suite of instrumentation, and trace heating to prevent salt freezing. The salt was purified in 2020 and 2022, and the pumped loop first operated in December 2022. FASTR is a unique US capability for high-temperature molten halide salt testing. FASTR’s scale, co located purification system, and relatively large power (465 kW) differentiates it from other testing systems. Furthermore, access to the DOE-supported facility and efficient communication of results— which are generally disseminated publicly—distinguish FASTR as being broadly significant throughout the molten salt reactor community. FASTR is similar to ORNL’s Liquid Salt Test Loop (LSTL), although FASTR contains chloride-based salt instead of the fluoride-based salt (LiF-NaF-KF) found in LSTL. Furthermore, FASTR is approximately 2× larger than LSTL in terms of pipe size and length, power, salt volume, flow rate, and number of thermocouples. The LSTL first operated in 2016. At the end of FY23, there was a suspected gas leak in the LSTL that halted operation. At the start of FY24, a leak in the LSTL pump’s tank gas space was confirmed. Because the gas-space leak prevented operation of LSTL, FY24 efforts were focused on operation of FASTR. This report summarizes the progress made during FY24 in support of the DOE Office of Nuclear Energy (DOE-NE) work package, AT-24OR070202 Salt Loop and Capability for Testing Sensors and Off Gas Components.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dynamic Heat Flow and Current Distribution Analysis in the Bottom Anode of an Electric Arc Furnace Using Fiber-Optic Sensors

A reliable method for monitoring bottom anode wear during DC Electric Arc Furnace (DC-EAF) operation is of critical importance for safe and efficient steel production. Underestimation of bottom wear poses a serious safety risk that must be avoided, while overestimation of bottom wear also poses challenges, as premature anode replacement is expensive and affects EAF productivity. Previously, we demonstrated that fiber-optic sensors can be successfully deployed to create a spatially distributed temperature map to monitor the health of the anode. The present work explores the heat flow and current density distribution in bottom anode pins to predict bottom wear, steel penetration events, and monitor refractory erosion. Small dynamic variations in pin temperature induced by joule heating during arcing also provide a means to observe local current flows in each pin. When mapped, these measurements provide a real-time view of the non-uniform and dynamic current flow in the bottom anode during EAF operation that can affect bottom wear.

Bottom Anode↗

Implementation and Operation of Power Flow Control Solutions for Transmission Systems

Power-flow controls (PFCs) technologies provide a suite of alternatives to more-efficiently direct the flow of power on the grid, improving flexibility and enabling the grid to be more responsive and resilient. PFCs can be used in many cases to mitigate overloads and consequently defer the installation of grid-expansion projects. They can also be suitable options in situations where new transmission lines cannot be built because of environmental constraints, land use, or other types of restrictions. Other uses include mitigation of loop or unintended flows, forcing of contractual or scheduled flows, reduction of congestion, and mitigation solutions during large maintenance or construction projects. While many studies have demonstrated the potential economic benefits of PFC for different types of applications, the implementation implications of using multiple PFCs for system operation and reliability have not been analyzed in detail. The lack of information and practical experience on these aspects hinders adoption of this technology. One use case would be that multiple PFCs are required to coordinate congestion management. In such cases, multiple PFCs are deployed in a meshed power system to control power flows across a wide area. The challenges are associated with PFC interaction—namely, the self and mutual power-flow sensitivity of each PFC, which must be accounted for in the calculation of the respective operating setpoints. This report analyzes implementation and operation that must be considered in evaluating transmission solutions using PFCs. The report first analyzes attributes with which PFC-based solutions should comply, based on the objective and characteristics of each particular use case. It then describes different approaches for coordinated control of multiple PFC devices for different applications, including options to avoid adverse interactions and reduce risks due to inappropriate coordination. Control and operation are illustrated through case studies performed on both generic and actual power system models. This report provides insights for transmission planners and operation engineers about the implementation of PFC-based transmission solutions; consequently, it will help them make informed decisions about the adoption of the technology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber100 Compass: Quantification of Cybersecurity Risks for Systems Transitioning to High Levels of Renewables (Final Report)

The shift to high levels of renewable deployment will entail a significant re-engineering of the grid. As investors, utilities, customers, and others prepare for clean energy transitions, there is need to understand how restructuring the grid to accommodate renewables will change the attack surface of the grid and accompanying cyber risk. However, today the cyber-physical risks associated with electric grids incorporating high levels of renewable deployment remain largely unknown. The Cyber100 Compass proof-of-concept application attempts to quantify future cyber-physical security risks by combining risk data gathered from subject matter experts (SMEs) with input from system planners about conditions they expect to be true about their electric systems in the future. Users provide data about their organization’s tolerance for risk; the value they place on avoiding the consequences of different cyber events; and conditions that they expect to be true on their systems at some point in the future. The SMEs provide baseline probabilities for different cyber events; the probability that an event will be low-, moderate-, or high-impact; and the amount by which user-identified conditions on their systems will change the likelihood of the cyber events. The application takes both the user and SME input and performs a series of Monte Carlo simulations to arrive at a quantification of risk.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nutrient Replenishment by Turbulent Mixing in Suspended Macroalgal Farms

Abstract This study uses large eddy simulations to investigate nutrient transport and uptake in suspended macroalgal farms. Various farm configurations and oceanic forcing conditions are examined, with the farm base located near the nutricline depth. We introduce the Damkohler number Da to quantify the balance between nutrient consumption by macroalgae uptake and supply by farm‐enhanced nutrient transport. Most cases exhibit low Da , indicating that farm‐generated turbulence drives sufficient upward nutrient fluxes, supporting macroalgae growth. High Da and starvation may occur in fully grown farm blocks, a configuration that generates the weakest turbulence, particularly when combined with densely planted macroalgae or weak flow conditions. Flow stagnation within the farm due to macroalgae drag may constrain the uptake efficiency and further increase the starvation risk. Mitigation strategies involve timely harvesting, avoiding dense macroalgae canopies, and selecting farm locations with robust ocean currents and waves. This study provides insights for sustainable macroalgal farm planning.

Geology↗

Real-time avoidance of the L-mode and H-mode density limit via machine-learned stability metrics

Reliable operation of burning plasma tokamaks will require robust control strategies to avoid macroscopic instability limits such as the L-mode and H-mode density limits (LDL, HDL). In this work, we explore closed-loop avoidance of these phenomena at DIII-D using machine-learned risk metrics. Feedback control is implemented via the ‘DL Supervisor’ scheme, which regulates the chosen risk metric by reducing the density target or increasing NBI heating in real-time. Using the LDL 25 risk metric, the LDL is reproducibly suppressed. We also introduce an HDL risk metric in this study, HDL 25 , which reduces the False Positive Rate by 2x compared to the Greenwald fraction. Applying this scaling to a plasma current ramp-down, we successfully avoid an HDL-driven H/L back-transition. These experiments constitute the first demonstration of real-time DL avoidance using machine-learned risk metrics. These instability metrics outline a path to safer high-density operation, more reliable ramp-down scenarios, and improved off-normal control for next-step devices such as ITER and SPARC.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analyzing Residential Charging Demand for Light-Duty Electric Vehicles in Colorado

The past decade has witnessed a remarkable surge in adoption of electric vehicles (EVs). The momentum is expected to continue with strong support from governments and industry. Rapid EV adoption will add significant electricity demand, making it critical to plan for and manage EV charging to avoid causing additional stress and non-negligible risks to the already-aging power grid. To help power grid operators understand the impacts of residential EV charging and identify risk factors, this study presents a data-driven charging demand analysis for light-duty vehicles. This study considers two real-world grid service regions in Colorado and merges multiple data sources and state-of-the-art tools that characterize EV adoption projections, vehicle travel patterns, seasonal variations, residential charging accessibility, ambient temperature impact, EV charging behaviors, grid utility customers, vehicle registration, and household-level EV charging demand distribution. We characterize potential residential charging demand in 2030 for two regions within the state of Colorado: Boulder and Aurora regions. We project that EVs will be 26% of the light-duty vehicle population in Boulder and 16% in Aurora areas. Charging demand is characterized for ten power grid feeders (five for each study region). Across the ten feeders, peak total EV charging powers during wintertime range from less than 1 MW to more than 4 MW.

ADVANCED PROPULSION SYSTEMS↗

Impact of representative ground motion level on seismic PSA with the boundary between overestimation and underestimation

One commonly used approach in seismic probabilistic safety assessment (PSA) is the discrete method. This method follows the standard PSA framework and can be applied to various models, such as multi-unit models, while reducing computational costs using standard software. However, due to the inability to subdivide intervals infinitely, the discrete method approximates with a finite number of subintervals. In practice, different numbers of subintervals are applied, and the representative ground motion level is selected based on expert judgment. When employing a smaller number of subintervals, it is important to take caution to prevent underestimation. This study analyzes the impact of the representative ground motion level on seismic risk. It confirms that underestimation can occur with a small number of subintervals depending on the representative ground motion level. This study also proposes a method for determining the boundary of underestimation and overestimation. The method is demonstrated through examples, providing a mathematical foundation for selecting appropriate representative ground motion levels. By avoiding underestimation, this research helps prevent the oversight of significant risk contributors and enhances the understanding of seismic risk.

99 - GENERAL AND MISCELLANEOUS↗

Quantifying Distribution System Resilience From Utility Data: Large Event Risk and Benefits of Investments

We focus on blackouts in electric distribution systems that have a large cost to customers. To quantify resilience to these events, we show how to calculate risk metrics from the historical outage data routinely collected by utilities' outage management systems. Risk is defined using a customer cost exceedance curve. The exceedance curve has a heavy tail that implies large fluctuations in large blackout costs, and this makes estimating the mean large cost in the usual way impractical. To avoid this problem, we use new resilience metrics describing the large event risk; these metrics are the probability of a large cost event, the annual log cost resilience index, and the average of the logarithm of the cost of large-cost events or the slope magnitude of the tail on a log–log exceedance curve. Resilience can be improved by planned investments to upgrade system components or speed up restoration. The benefits that these investments would have had if they had been made in the past can be quantified by “rerunning history” with the effects of the investment included, and then recalculating the large event risk to find the improvement in resilience. An example using utility data shows a 2% reduction in the probability of a large cost event due to 10% wind hardening and 6%–7% reduction due to 10% faster restoration in two different areas of a distribution utility. This new data-driven approach to quantify resilience and resilience investments is realistic and much easier to apply than complicated approaches based on modeling all the phases of resilience. Moreover, an appeal to improvements to past lived experience may well be persuasive to customers and regulators in making the case for resilience investments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cost-Benefit Analysis of Electricity Resilience Projects: State of the Art and Gap Analysis

Utilities and regulators must weigh the benefits of electricity resilience projects against their costs, which would be passed on to customers. Cost-benefit analysis (CBA) is an appropriate method for assessing this tradeoff. Here, in this paper we review the literature on CBA of electricity resilience projects and analyze gaps in the available methods and tools. The costs of resilience projects are typically straightforward to estimate but their benefits — particularly the avoided costs of power interruptions — are complex to quantify and monetize. A common perception among practitioners is that current CBA tools are not sufficiently mature to be adopted into real-world practice. We propose an electricity resilience CBA framework consisting of several elements: risks, physical impacts, power interruptions, economic impacts, and resilience projects. While methods for some elements are well-developed, there is a need for novel approaches to value avoided power interruptions, integrate multiple risks and benefit streams, and incorporate uncertainty.

Cost-benefit analysis↗

First-of-a-Kind Risk-Informed Digital Twin for Operational Decision Making

A digital twin (DT) is a digital model or a collection of models of a physical entity. DTs in the nuclear arena can be used from plant design through decommissioning. Decisions are typically a priori or made offline. Risk-informed decision making is identifying what can go wrong, its frequency, and the consequences of its failure. Ideally risk-informed decision making reflects the current state of the plant and provides a decision in real time. Traditionally, probabilistic risk assessments (PRAs) evaluate the failures of safety systems, the risk of core damage, and the offsite dose as the consequence. However, this DT evaluates the decisions on the control side rather than the protection side. It uses the same risk methods to probabilistically inform the decision-making process but in a different way. Rather than evaluating the risk of core damage, this DT evaluates the likelihood of avoiding a trip set point while maintaining plant safety. Performance-based assessments are identified via its probabilistic evaluation of operational alternatives based on system status. Because the purpose of the control system is to maintain system variables within prescribed operating ranges, upsets or challenges that can exceed a trip set point resulting in a plant transient and a challenge to plant mitigating systems based on actual plant conditions, are evaluated to safely maintain the plant within the operating ranges. The probabilistic portion of the model is autonomously and automatically adjusted, and the metric of interest (i.e. likelihood of avoiding a trip set point) is recalculated. The digital representation of the physical system (i.e. the DT) performs a deterministic performance–based assessment of the probabilistically identified alternatives identified to validate the probabilistic assessment. A decision-making algorithm selects the appropriate option based on the probabilistic and deterministic assessments and transmits a control signal to a component(s) to initiate a corrective action or informs an operator of its decision.

digital twin↗

Initial design concepts for solid boron injection in ITER

As part of ITER’s consideration to change its first wall material from beryllium to tungsten, the ITER Organization has proposed studying the feasibility of real-time solid boron injection (SBI) into the plasma to coat the walls and divertor to supplement glow discharge boronization (GDB). Boron deposits getter oxygen and reduce sputtering of tungsten from plasma facing components (PFCs). Particularly in areas with significant plasma wall interactions, boron coatings are expected to be short-lived under high performance plasma conditions. The proposed SBI system aims to maintain boron layers in these areas to avoid excessive radiation from tungsten in the plasma as a risk mitigation to ensure ITER will be able to reach and sustain Q = 10 conditions. The system will be used sparingly, as redeposition of boron can lead to significant tritium retention, which must be minimized in ITER to comply with nuclear safety concerns. SBI is proposed to limit and precisely control the amount of boron injected in real-time during plasma operation. Here, some of the design requirements and initial concepts for an SBI system in ITER are presented based on previous results carried out with SBI systems on a number of tokamaks and stellarators around the world. Previous results using SBI systems installed by PPPL have injected boron particles from 5 µm–2 mm diameter at calibrated rates of 2–200 mg/s in real-time during plasma operation on AUG, DIII-D, EAST, KSTAR, LHD, TFTR, WEST, and W7-X, leading to improved wall conditions with reduced plasma impurity concentrations and radiated power and improved plasma performance. The boron is ionized in the plasma edge and then deposited on plasma-wetted surfaces. On AUG, EAST and WEST reduced tungsten sputtering sources were observed following several discharges with SBI. Extrapolation of these SBI results are presented to estimate the amount of boron needed for wall conditioning in ITER. Real-time SBI control requirements and plasma operation scenarios for ITER are also described.

36 MATERIALS SCIENCE↗

A review of United States energy-only generator interconnection service policy and considerations for reform

Grid interconnection has emerged as a significant obstacle to the development of new electricity resources. There is growing interest in energy-only interconnection, which is an interconnection service option meant to allow the interconnection of new generators without ensuring their energy deliverability during all hours through the transmission system to customers. This approach potentially avoids upfront congestion-related transmission upgrades but could increase curtailment risk. Interest in energy-only interconnection is shaped by incomplete understanding of how interconnection policy functions in different jurisdictions, a knowledge gap that makes it difficult to determine how energy-only interconnection might be better used or re-designed. In this paper, we provide a regulatory review of energy-only interconnection in U.S. interconnection policy and practice, identifying jurisdictions in which rules are close to -or farther from-the theoretical concept of energy-only interconnection service. We find substantial jurisdictional differences in how energy-only interconnection is implemented, driven by differences in resource adequacy frameworks, real-time transmission operations, and state-level procurement practices. U.S. regulators have preferred local jurisdictional flexibility over federal prescription of interconnection study methods and procedures, which also contributes to differences among regions. Such findings raise fundamental questions about whether competition policies in electricity markets should extend beyond spot energy markets and into more prescriptive guidelines around interconnection rules and market entry. This paper sheds light on tensions that energy-only interconnection raises in allowing generators to access the transmission system on an as available basis and discusses how controlling thresholds for congestion-related network upgrades may be a barrier to electricity market entry.

Gorman, Will↗

Evaluating offshore legacy wells for geologic carbon storage: A case study from the Galveston and Brazos areas in the Gulf of Mexico

In this article, federal offshore waters in the Gulf of Mexico are of interest for large-scale geologic carbon storage (GCS). However, more than 80,000 offshore oil and gas wells exist in the region, which could impact the integrity of sealing intervals. In this study, we propose a screening methodology for ranking offshore legacy wells based on the challenge they may present to GCS. The methodology relies on the review of well regulatory records to 1) identify leakage pathways and assess the potential hazards that wells pose to planned GCS operations, 2) evaluate well features that impact the accessibility of wells to determine the feasibility of potential corrective actions, and 3) rank wells based on the overall challenge they may pose for GCS. We demonstrate our framework by evaluating the construction and abandonment of 156 wells across eight areas of interest (AOIs) in shallow federal waters along the Texas Gulf Coast. The majority (99.3 %) of wells considered were constructed and plugged in a manner that did not isolate prospective GCS targets in the Upper and Lower Miocene formations and may potentially require a challenging or uncertain corrective action prior to GCS. Dataset trends suggest that the observed well construction and plugging designs may be common in shallow offshore federal waters along the Texas Gulf Coast. Consequently, operators pursuing offshore GCS projects in the region may consider selecting areas that avoid challenging wells or performing robust evaluations of legacy well leakage risks to plan corrective action prior to CO 2 injection.