Search NASA⌕ Search

SEARCH · Search NASA

Results for “axion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The pathfinder X-Ray axion telescope for the International Axion Observatory (IAXO) and axion searches at the CERN Axion Solar Telescope (CAST)

The axion, a hypothetical pseudo-scalar particle proposed by Peccei and Quinn to resolve the strong CP problem in quantum chromodynamics, remains one of the most compelling dark matter candidates. Axions and Axion-Like Particles (ALPs) are characterized by a broad and largely unconstrained parameter space in mass and coupling strength, motivating extensive experimental searches. The International Axion Observatory (IAXO) is a next-generation axion helioscope designed to achieve over an order of magnitude improvement in sensitivity to the axion-photon coupling constant gaγ relative to previous experiments such as the CERN Axion Solar Telescope (CAST). IAXO will employ large-scale superconducting magnets, precision x-ray optics, and ultra-low-background detectors to search for solar axions produced primarily via the Primakoff effect. This work presents the design and performance of the IAXO pathfinder x-ray optic, a technological demonstrator that validated the optical concepts for IAXO through axion searches at CAST. Comprehensive ray-tracing simulations and experimental measurements were conducted to assess the optic's effective area, detection efficiency, and background suppression capabilities. Deployed at CAST in conjunction with Micromegas and GridPix detectors, the Pathfinder demonstrated record-setting sensitivity to both gaγ and the axion-electron coupling gae, establishing the most stringent laboratory constraints on solar axions to date. These results confirm the viability of the IAXO optical design and detector concept, providing a critical technological benchmark that informs the ongoing development of the BabyIAXO and full-scale IAXO telescopes.

47 OTHER INSTRUMENTATION↗

Axion dark matter experiment: Run 1B analysis details

Searching for axion dark matter, the ADMX Collaboration acquired data from January to October 2018, over the mass range 2.81–3.31 μeV, corresponding to the frequency range 680–790 MHz. Using an axion haloscope consisting of a microwave cavity in a strong magnetic field, the ADMX experiment excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions at 90% confidence level and 100% dark matter density over this entire frequency range, except for a few gaps due to mode crossings. This paper explains the full ADMX analysis for run 1B, motivating analysis choices informed by details specific to this run.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Axion Dark Matter Experiment: Detailed design and operations

Axion dark matter experiment ultra-low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the 2.66–3.1 μeV mass range with Dine–Fischler–Srednicki–Zhitnisky sensitivity. Therefore, it is the most sensitive axion search experiment to date in this mass range. Here, we discuss the technological advances made in the last several years to achieve this sensitivity, which includes the implementation of components, such as the state-of-the-art quantum-noise-limited amplifiers and a dilution refrigerator. Furthermore, we demonstrate the use of a frequency tunable microstrip superconducting quantum interference device amplifier in run 1A, and a Josephson parametric amplifier in run 1B, along with novel analysis tools that characterize the system noise temperature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Axions and SN 1987A: Axion trapping

If an axion of mass between about 10(exp -3) eV and 1 eV exists, axion emission would have significantly affected the cooling of the nascent neutron star associated with SN 1987A. For an axion of mass less than about 10(exp -2) eV, axions produced deep inside the neutron star simply stream out; in a previous paper this case has been addressed. Remarkably, for an axion of mass greater than about 10(exp -2) eV axions would, like neutrinos, have a mean-free path that is smaller than the size of a neutron star, and thus would become 'trapped' and radiated from an axion sphere. In this paper the trapping regime is treated by using numerical models of the initial cooling of a hot neutron star that incorporate a leakage approximation scheme for axion-energy transport. The axion opacity is computed due to inverse nucleon-nucleon, axion bremsstrahlung, and numerical models are used to calculate the integrated axion luminosity, the temperature of the axion sphere, and the effect of axion emission on the neutrino bursts detected by the Kamiokande 2 (K2) and Irvine-Michigan-Brookhaven (IMB) water-Cherenkov detectors. The larger the axion mass, the stronger the trapping and the smaller the axion luminosity. The earlier estimate is confirmed and refined of the axion mass above which trapping is so strong that axion emission does not significantly affect the neutrino burst. Based upon the neutrino-burst duration--the most sensitive barometer of axion cooling--it is concluded that for an axion mass of greater than about 0.3 eV, axion emission would not have had a significant effect on the neutrino bursts detected by K2 and IMB. The present work, together with the previous work, strongly suggests that an axion with mass in the interval 10(exp -3) eV to 0.3 eV is excluded by SN 1987A.

Burrows, Adam↗

Axions and SN 1987A: Axion trapping

If an axion of mass between about 10(exp -3) and 10 eV exists, axion emission would have significantly affected the cooling of the nascent neutron star associated with SN 1987A. For an axion of mass greater than about 10(exp -2) eV axions would, like neutrinos, have a mean-free path that is smaller than the size of a neutron star, and thus would become trapped and radiated from an axion sphere. The trapping regime is treated by using numerical models of the initial cooling of a hot neutron star that incorporate a diffusion approximation for axion-energy transport. The axion opacity due to inverse nucleon-nucleon, axion bremsstrahlung is computed; and then the numerical models are used to calculate the integrated axion luminosity, the temperature of the axion sphere, and the effect of axion emission on the neutrino bursts detected by the Kamiokande II (KII) and Irvine-Michigan-Brookhaven (IMB) water-Cherenkov detectors. The larger the axion mass, the stronger the trapping and the smaller the axion luminosity. The estimate of the axion mass is confirmed above which trapping is so strong that axion emission does not significantly affect the neutrino burst. Based upon the neutrino-burst duration - the most sensitive barometer of axion cooling - it is concluded that for an axion mass greater than about 3 eV axion emission would not have had a significant effect on the neutrino bursts detected by KII and IMB. It is strongly suggested that an axion with mass in the interval 10(exp -3) to 3 eV is excluded by the observation of neutrinos from SN 1987A.

Burrows, Adam↗

Dark matter axion search using a Josephson Traveling wave parametric amplifier

Here, we describe the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in an axion dark matter search. The operation of the JTWPA for a period of about two weeks achieved sensitivity to axion-like particle dark matter with axion–photon couplings above 10 -13 Ge V -1 over a narrow range of axion masses centered around 19.84 µeV by tuning the resonant frequency of the cavity over the frequency range of 4796.7–4799.5 MHz. The JTWPA was operated in the insert of the axion dark matter experiment as part of an independent receiver chain that was attached to a 0.56-l cavity. The ability of the JTWPA to deliver high gain over a wide (3 GHz) bandwidth has engendered interest from those aiming to perform broadband axion searches, a longstanding goal in this field.

47 OTHER INSTRUMENTATION↗

Search for solar axions produced through the axion-electron coupling gae using a new GridPix detector at CAST

We present a search for solar axions produced through the axion-electron coupling (g ae ) using data from a novel 7-GridPix detector installed at the CERN Axion Solar Telescope (CAST). The detector, featuring ultra-thin silicon nitride windows and multiple veto systems, collected approximately 160 hours of solar tracking data between 2017–2018. Using machine learning techniques and the veto systems, we achieved a background rate of 1.06 × 10 −5 keV −1 cm −2 s −1 at a signal efficiency of about 80% in the 0.2 to 8 keV range. Analysis of the data yielded no significant excess above background, allowing us to set a new upper limit on the product of the axion-electron and axion-photon couplings of g ae · g aγ < 7.35 × 10 −23 GeV −1 at 95% confidence level for axion masses below 10 meV. This result improves upon the previous best helioscope limit and demonstrates the potential of GridPix technology for rare event searches. Additionally, we derived a limit on the axion-photon coupling of g aγ < 9.0 × 10 −11 GeV −1 at 95% CL, which, while not surpassing CAST’s best limit, provides complementary constraints on axion models.

Beyond Standard Model↗

Inching toward the QCD axions with axion magnetic resonance in helioscopes

Utilizing a helical magnet profile to enhance axion-photon conversion showed great promise in laboratory searches for high axion masses. We extend the mechanism, known as the axion-magnetic resonance (AMR), from laser experiments to axion helioscopes and demonstrate its potential in covering QCD axion parameter space. Specifically, we apply AMR to the CAST experiment legacy, make projections for the upcoming IAXO experiment, and assess its implications for both axion-like particles and QCD axions. We observe considerable improvement in the experiment’s sensitivity reach in all cases.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Probing the Cosmic Axion Background via Axion-Photon Conversion in Filaments

The cosmic axion background (CaB) is a hypothetical population of relativistic axions produced in the early universe. If the CaB is produced from dark matter decays, the axions in this population can convert to photons in the magnetic fields of cosmological filaments, resulting in an isotropic gamma ray background flux. We present new indirect detection constraints on the axion mass and axion-photon coupling, for GeV-TeV dark matter with a decay lifetime below $10^{30}$ sec, by comparing this flux against experimental data. We exclude significant parameter space for axion masses below $10^{-5}$~eV for a broad range of dark matter masses and lifetimes, assuming conservative filament magnetic field strengths ($\sim 1$ nG). For large filament fields ($\sim 100$ nG), our strategy also constrains a portion of the QCD-axion parameter space for TeV-scale dark matter masses.

Rocha, Duncan [Chicago U., EFI; Chicago U., KICP]↗

Axion magnetic resonance: A novel enhancement in axion-photon conversion

We identify a new resonance, axion magnetic resonance, that can greatly enhance the conversion rate between axions and photons. A series of axion search experiments rely on converting them into photons inside a constant magnetic field background. A common bottleneck of such experiments is the conversion amplitude being suppressed by the axion mass when m a ≳ 10 − 4 eV . We point out that a spatial or temporal variation in the magnetic field can cancel the difference between the photon dispersion relation and that of the axion, hence greatly enhancing the conversion probability. We demonstrate that the enhancement can be achieved by both a helical magnetic field profile and a harmonic oscillation of the magnitude. Our approach can extend the projected ALPS II reach in the axion-photon coupling ( g a γ ) by two orders of magnitude at m a = 10 − 3 eV with moderate assumptions (see .) Published by the American Physical Society 2024

79 ASTRONOMY AND ASTROPHYSICS↗

CP-violating axion interactions II: axions as dark matter

Axions provide a solution to the strong CP problem and are excellent dark matter candidates. The presence of additional sources of CP violation, for example to account for the matter/antimatter asymmetry of the universe, can lead to CP-violating interactions between axions and Standard Model fields. In case axions form a coherent dark matter background, this leads to time-oscillating fundamental constants such as the fine-structure constant and particle masses. In this work we compare the sensitivity of various searches for CP-odd axion interactions. These include fifth-force experiments, searches for time-oscillating constants induced by axion dark matter, and direct limits from electric dipole moment experiments. We show that searches for oscillating constants can outperform fifth-force experiments in the regime of small axion masses, but, in general, do not reach the sensitivity of electric dipole moment experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Probing the axion–nucleon coupling with the next generation of axion helioscopes

Abstract A finite axion–nucleon coupling, nearly unavoidable for QCD axions, leads to the production of axions via the thermal excitation and subsequent de-excitation of $$^{57}$$ 57 Fe isotopes in the sun. We revise the solar bound on this flux adopting the up to date emission rate, and investigate the sensitivity of the proposed International Axion Observatory IAXO and its intermediate stage BabyIAXO to detect these axions. We compare different realistic experimental options and discuss the model dependence of the signal. Already BabyIAXO has sensitivity far beyond previous solar axion searches via the nucleon coupling and IAXO can improve on this by more than an order of magnitude.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Broadband Solenoidal Haloscope for Terahertz Axion Detection

We introduce the Broadband Reflector Experiment for Axion Detection (BREAD) conceptual design and science program. This haloscope plans to search for bosonic dark matter across the [ 10 - 3 , 1 ] eV ([0.24, 240] THz) mass range. BREAD proposes a cylindrical metal barrel to convert dark matter into photons, which a novel parabolic reflector design focuses onto a photosensor. This unique geometry enables enclosure in standard cryostats and high-field solenoids, overcoming limitations of current dish antennas. A pilot 0.7 m 2 barrel experiment planned at Fermilab is projected to surpass existing dark photon coupling constraints by over a decade with one-day runtime. Axion sensitivity requires < 10 - 20 W / Hz sensor noise equivalent power with a 10 T solenoid and 10 m 2 barrel. We project BREAD sensitivity for various sensor technologies and discuss future prospects.

Liu, Jesse↗

Design of axion and axion dark matter searches based on ultra high Q SRF cavities

The Superconducting Quantum Materials and Systems center is developing searches for dark photons, axions and ALPs with the goal of improving upon the current state-of-the-art sensitivity. These efforts leverage on Fermi National Accelerator expertise on ultra-high quality factor superconducting radio frequency cavities combined with the center research on quantum technology. Here we focus on multiple axion searches that utilize ~1E10 quality factor superconducting radio frequency cavities and their resonant modes to enhance the production and/or detection of axions in the cavity volume. In addition, we present preliminary results of single-mode and multi-mode nonlinearity measurements that were carried out as part of an experimental feasibility study to gain insight on the behavior of the ultra-high quality factor resonators and the experimental RF system in the regime relevant for axion searches.

43 PARTICLE ACCELERATORS↗