Identifying environmentally induced calibration changes in cryogenic RF axion detector systems using deep neural networks

The axion is a compelling hypothetical particle that could account for the dark matter in our universe while simultaneously solving the strong CP problem in quantum chromodynamics. The most sensitive axion detection technique demonstrated so far makes use of a high Q cavity immersed in a strong magnetic field, where axions are converted to microwave photons. This is called an axion haloscope and has primarily targeted the 1–10 GHz range. As searches scan up in axion mass, toward the parameter space favored by theoretical predictions, individual cavity sizes decrease in order to achieve higher frequencies. This shrinking cavity volume translates directly to a loss in signal-to-noise, motivating the plan to replace individual cavity detectors with arrays of cavities. When the transition from one to (N) multiple cavities occurs, haloscope searches are anticipated to become much more complicated to operate, requiring N times as many measurements but also the new requirement that N detectors operate in unison, which can be achieved by locking them to a common frequency. To offset this anticipated increase in detector complexity, we aim to develop new tools for diagnosing experiments using neural networks. Current experiments monitor scattering parameters of their receiver for periodically measuring cavity quality factor and coupling. However, off-resonant data remain relatively useless. In this paper, we ask if it is possible that off-resonant information contained in vector network analyzer scans could be used to diagnose equipment failures/anomalies and measure physical conditions (e.g., temperatures and ambient magnetic field). We demonstrate a proof-of-concept that AI techniques can help manage the complexity of an axion haloscope search for operators.

Engel, Andrew W. [Pacific Northwest National Labor↗

Bragg-Primakoff axion photoconversion in crystal detectors

Abstract Axions and axion-like pseudoscalar particles with dimension-5 couplings to photons exhibit coherent Primakoff scattering with ordered crystals at keV energy scales, making for a natural detection technique in searches for solar axions. We find that there are large suppressive corrections, potentially greater than a factor of$$ \mathcal{O} $$ O (10 3 ), to the coherent enhancement when taking into account absorption of the final state photon. This effect has already been accounted for in light-shining-through-wall experiments through the language of Darwin classical diffraction, but is missing from the literature in the context of solar axion searches that use a matrix element approach. We extend the treatment of the event rate with a heuristic description of absorption effects to bridge the gap between these two languages. Furthermore, we explore the Borrmann effect of anomalous absorption in lifting some of the event rate suppression by increasing the coherence length of the conversion. We study this phenomenon in Ge, NaI, and CsI crystal experiments and its impact on the projected sensitivities of SuperCDMS, LEGEND, and SABRE to the solar axion parameter space. Lastly, we comment on the reach of multi-tonne scale crystal detectors and strategies to maximize the discovery potential of experimental efforts in this vein.

Physics↗

Periodic signatures for the detection of cosmic axions

In a Sikivie-type cosmic-axion detector, both the width and position of the microwave signal due to axion-photon conversion depend upon the motions of the earth. Due to the orbital and rotational motions of the earth they will be modulated with periods of 1 sidereal day and 1 sidereal year, with amplitudes of about 0.1 percent and 5 percent respectively. Because of the intrinsically-high energy resolution of Sikivie-type detectors such periodic variations should be detectable. Such modulations would not only aid in confirming the detection of cosmic axions, but, if found, would also provide important information about the distribution of axions in the halo.

Turner, Michael S.↗

A Large Bore Conduction Cooled Superconducting Magnet for the Princeton Axion Search

Princeton University (PU) is designing and building a new experiment, called the Princeton Axion Search (PXS), that aims to discover (or exclude) Quantum Chromodynamics (QCD) axions in the 0.8–2 μeV mass range that are the cosmological dark matter. Core elements of the experiment are new, and in particular new to the search for axion dark matter. An essential component of the experiment is a 5 T superconducting magnet with a total bore volume of ~500 L. The Princeton Plasma Physics Laboratory (PPPL), a Department of Energy (DOE) Laboratory managed by Princeton University, has the unique expertise and experimental facilities to design and construct such a solenoid magnet assembled with the cavity resonator for PXS. To support this, PPPL utilizes legacy ITER-Nb3Sn conductors, along with its experimental facilities and expertises to design, build and test low-cost conduction-cooled superconducting solenoid magnets to be integrated into the axion detector. This paper discusses the various coil design and integration challenges in the large bore conduction cooled magnet in support of PXS. In conclusion, the proposed instrumental methods will help optimize the path to future and more ambitious axion searches at lower masses.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Axions beyond Gen 2

The QCD (Quantum ChromoDynamics) axion emerged as one of the best-motivated dark matter candidates. In 2018, the Axion Dark Matter eXperiment (ADMX), one of the U.S. Department of Energy’s “Gen 2” flagship dark-matter projects, demonstrated first sensitivity to the highly plausible “DFSZ” dark matter axion couplings over a small frequency range. We anticipate this development marks the first step in constructing yet more powerful experiments that can explore large swaths of the axion parameter space at high sensitivity and result in a discovery. But, realizing this requires advances in both our understanding of the theory and experiment design. Between 25 January and 27 January 2021, the “Axions Beyond Gen 2 Workshop” was held, where selected members of the community discussed our broad understanding of the QCD axion and charted a course for future experiments having sensitivity and mass reach well beyond the current “Gen 2” experiments. These proceedings are summaries of the topics presented and discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for solar axions produced through the axion-electron coupling gae using a new GridPix detector at CAST

We present a search for solar axions produced through the axion-electron coupling (g ae ) using data from a novel 7-GridPix detector installed at the CERN Axion Solar Telescope (CAST). The detector, featuring ultra-thin silicon nitride windows and multiple veto systems, collected approximately 160 hours of solar tracking data between 2017–2018. Using machine learning techniques and the veto systems, we achieved a background rate of 1.06 × 10 −5 keV −1 cm −2 s −1 at a signal efficiency of about 80% in the 0.2 to 8 keV range. Analysis of the data yielded no significant excess above background, allowing us to set a new upper limit on the product of the axion-electron and axion-photon couplings of g ae · g aγ < 7.35 × 10 −23 GeV −1 at 95% confidence level for axion masses below 10 meV. This result improves upon the previous best helioscope limit and demonstrates the potential of GridPix technology for rare event searches. Additionally, we derived a limit on the axion-photon coupling of g aγ < 9.0 × 10 −11 GeV −1 at 95% CL, which, while not surpassing CAST’s best limit, provides complementary constraints on axion models.

Beyond Standard Model↗

The design, implementation, and performance of the LZ calibration systems

LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low energy nuclear recoils. Surrounding the TPC, two veto detectors immersed in an ultra-pure water tank enable reducing background events to enhance the discovery potential. Intricate calibration systems are purposely designed to precisely understand the responses of these three detector volumes to various types of particle interactions and to demonstrate LZ's ability to discriminate between signals and backgrounds. In this paper, we present a comprehensive discussion of the key features, requirements, and performance of the LZ calibration systems, which play a crucial role in enabling LZ's WIMP-search and its broad science program. The thorough description of these calibration systems, with an emphasis on their novel aspects, is valuable for future calibration efforts in direct dark matter and other rare-event search experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration plan for the SBC 10-kg liquid argon detector with 100 eV target threshold

The Scintillating Bubble Chamber (SBC) Collaboration is designing a new generation of low background, noble liquid bubble chamber experiments with sub-keV nuclear recoil threshold. These experiments combine the electronic recoil blindness of a bubble chamber with the energy resolution of noble liquid scintillation, and maintain electron recoil discrimination at higher degrees of superheat (lower nuclear recoil thresholds) than Freon-based bubble chambers. A 10-kg liquid argon bubble chamber has the potential to set world leading limits on the dark matter nucleon cross-section for 𝒪(GeV/c 2 ) masses, and to perform a high statistics coherent elastic neutrino nuclear scattering measurement with reactor neutrinos. This work presents a detailed calibration plan to measure the detector response of these experiments, combining photoneutron scattering with two new techniques to induce sub-keV nuclear recoils: nuclear Thomson scattering and thermal neutron capture.

Dark Matter detectors (WIMPs, axions, etc.)↗

Searching for axion dark matter with array-scalable single magnon detectors

We introduce an array-scalable, magnon-based detector to search for the spin-dependent interactions of electron-coupled axion dark matter with mass in the 1−100 μ⁢eV range. These axions can excite single magnons in magnetic targets, such as yttrium iron garnet (YIG) spheres, which are subsequently sensed by the detector. In our concept, this sensing is implemented by coupling the magnons in the YIG spheres to magnetic-field-resilient single-electron charge-qubits, whose state is then interrogated with a quantum nondemolition measurement. Using standard superconducting fabrication techniques, it is possible to integrate many YIG sphere-qubit sensors, forming a large detector array. We outline the detector design and operation for our concept, and determine its sensitivity to axion dark matter. We find that using available technology can already exceed the sensitivity of previous ferromagnetic haloscopes, and further improvements in performance would search for electron-coupled axion dark matter in unexplored parameter space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Daily modulations and broadband strategy in axion searches: An application with the CAST-CAPP detector

It has been previously advocated that the presence of the daily and annual modulations of the axion flux on the Earth’s surface may dramatically change the strategy of the axion searches. The arguments were based on the so-called Axion Quark Nugget (AQN) dark matter model which was originally put forward to explain the similarity of the dark and visible cosmological matter densities Ω dark ∼ Ω visible . In this framework, the population of galactic axions with mass 10 − 6 eV ≲ m a ≲ 10 − 3 eV and velocity ⟨ v a ⟩ ∼ 10 − 3 c will be accompanied by axions with typical velocities ⟨ v a ⟩ ∼ 0.6 c emitted by AQNs. Furthermore, in this framework, it has also been argued that the AQN-induced axion daily modulation (in contrast with the conventional weakly interactive massive particle paradigm) could be as large as (10–20)%, representing the main motivation for the present investigation. We argue that the daily modulations along with the broadband detection strategy can be very useful tools for the discovery of such relativistic axions. The data from the CAST-CAPP detector have been used following such arguments. Unfortunately, due to the dependence of the amplifier chain on temperature-dependent gain drifts and other factors, we could not conclusively show the presence or absence of a dark sector-originated daily modulation. However, this proof of principle analysis procedure can serve as a reference for future studies. Published by the American Physical Society 2025

Caspers, F.↗

Highly excited electron cyclotron for QCD axion and dark-photon detection

We propose using highly excited cyclotron states of a trapped electron to detect meV axion and dark-photon dark matter, marking a significant improvement over our previous proposal and demonstration [One-electron quantum cyclotron as a milli-ev dark-photon detector, .]. When the axion mass matches the cyclotron frequency ω c , the cyclotron state is resonantly excited, with a transition probability proportional to its initial quantum number, n c . The sensitivity is enhanced by taking n c ∼ 10 6 ( 0.1 meV ω c ) 2 . By optimizing key experimental parameters, we minimize the required averaging time for cyclotron detection to t ave ∼ 10 − 6 s, permitting detection of such a highly excited state before its decay. An open–end-cap trap design enables the external photon signal to be directed into the trap, rendering our background-free detector compatible with large focusing cavities, such as the BREAD proposal, while capitalizing on their strong magnetic fields. Furthermore, the axion conversion rate can be coherently enhanced by incorporating layers of dielectrics with alternating refractive indices within the cavity. Collectively, these optimizations enable us to probe the QCD axion parameter space from 0.1 to 2.3 meV (25–560 GHz), covering a substantial portion of the predicted postinflationary QCD axion mass range. This sensitivity corresponds to probing the kinetic mixing parameter of the dark photon down to ε ≈ 2 × 10 − 16 . Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Flow and thermal modelling of the argon volume in the DarkSide-20k TPC

The DarkSide-20k dark matter experiment, currently under construction at LNGS, features a dual-phase time projection chamber (TPC) with a ∼ 50 t argon target from an underground well. At this scale, it is crucial to optimise the argon flow pattern for efficient target purification and for fast distribution of internal gaseous calibration sources with lifetimes of the order of hours. To this end, we have performed computational fluid dynamics simulations and heat transfer calculations. The residence time distribution shows that the detector is well-mixed on time-scales of the turnover time (∼ 40 d). Notably, simulations show that despite a two-order-of-magnitude difference between the turnover time and the half-life of 83m Kr of 1.83 h, source atoms have the highest probability to reach the centre of the TPC 13 min after their injection, allowing for a homogeneous distribution before undergoing radioactive decay. We further analyse the thermal aspects of dual-phase operation and define the requirements for the formation of a stable gas pocket on top of the liquid. We find a best-estimate value for the heat transfer rate at the liquid-gas interface of 62 W with an upper limit of 144 W and a minimum gas pocket inlet temperature of 89 K to avoid condensation on the acrylic anode. This study also informs the placement of liquid inlets and outlets in the TPC. The presented techniques are widely applicable to other large-scale, noble-liquid detectors.

47 OTHER INSTRUMENTATION↗

Technical design report for the CODEX- β demonstrator

The CODEX-β apparatus is a demonstrator for the proposed future CODEX-b experiment, a long-lived-particle detector foreseen for operation at IP8 during HL-LHC data-taking. The demonstrator project, intended to collect data in 2025, is described, with a particular focus on the design, construction, and installation of the new apparatus.

Dark Matter detectors (WIMPs, axions, etc.)↗

High-Frequency Gravitational Wave Search with ABRACADABRA-10 cm

ABRACADABRA-10 cm has had great success as a pathfinder lumped-element axion dark matter experiment, setting limits on axion dark matter at the GUT scale. Now, using the interaction of gravitational waves with electrodynamics and a change in readout strategy, we use the ABRA-10 cm detector for the first search for high-frequency gravitational waves using a modified axion detector. Potential sources at these high frequencies (10 kHz to 5 MHz) include merging primordial black hole binaries or superradiance, among other beyond the standard model phenomena. This paper presents the design, results, and challenges from the ABRA-10 cm high-frequency gravitational wave search, showing it is possible to simultaneously look for axions and high-frequency gravitational waves with both searches matching theoretical expectations for sensitivity. Additionally, we conducted the first time series transient search with data from an axion experiment, achieving sensitivity to $10^{-4}$ in strain. Scaled directly to the next generation axion experiment, DMRadio-GUT, this sensitivity would imply a reach to 0.01 $M_{\odot}$ primordial black hole mergers at distances around 3 pc, with prospects to go significantly further with modifications to the readout.

Pappas, Kaliroë M.W. [MIT, LNS] (ORCID:00000003425↗

Search for axion-like particles through nuclear Primakoff production using the GlueX detector

We report on the results of the first search for the production of axion-like particles (ALPs) via Primakoff production on nuclear targets, γA → aA, in the “SRC-CT” experiment using the GlueX detector at Jefferson Lab. This search uses an integrated luminosity of 100 pb -1 nucleon on a 12 C target with a real photon beam of energies 6 < E γ < 10.8 GeV, and explores the mass region of 200 < m a < 450 MeV via the decay a → γγ. This mass range is between the π 0 and η meson masses, which enables the use of the measured η meson production rate to obtain absolute bounds on the ALP production with reduced sensitivity to experimental luminosity and detection efficiency. We find no evidence for an ALP, consistent with previous searches in the quoted mass range, and present limits on the effective photon coupling scale of $\mathscr{O}$(1 TeV -1 ). We further find that the ALP production limit we obtain is hindered by the peaking structure of the non-target-related dominant background the in GlueX spectrometer, which we treat by using data on 4 He to estimate and subtract it. We comment on how this search can be improved in a future higher-statistics dedicated measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rydberg-atom-based single-photon detection for haloscope axion searches

We propose a Rydberg-atom-based single-photon detector for signal readout in dark matter haloscope experiments between 40 μ eV and 200 μ eV (10 GHz and 50 GHz). At these frequencies, standard haloscope readout using linear amplifiers is limited by quantum measurement noise, which can be avoided by using a single-photon detector. Our single-photon detection scheme can offer scan rate enhancements up to a factor of 10 4 over traditional linear amplifier readout, and is compatible with many different haloscope cavities. We identify multiple haloscope designs that could use our Rydberg-atom-based single-photon detector to search for QCD axions with masses above 40 μ eV (10 GHz), currently a minimally explored parameter space. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absorption of Axion Dark Matter in a Magnetized Medium

Detection of axion dark matter heavier than an meV is hindered by its small wavelength, which limits the useful volume of traditional experiments. This problem can be avoided by directly detecting in-medium excitations, whose ∼ meV – eV energies are decoupled from the detector size. We show that for any target inside a magnetic field, the absorption rate of electromagnetically coupled axions into in-medium excitations is determined by the dielectric function. As a result, the plethora of candidate targets previously identified for sub-GeV dark matter searches can be repurposed as broadband axion detectors. We find that a kg yr exposure with noise levels comparable to recent measurements is sufficient to probe parameter space currently unexplored by laboratory tests. Noise reduction by only a few orders of magnitude can enable sensitivity to the QCD axion in the ∼ 10 meV – 10 eV mass range. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantum-Enhanced Sensing of Axion Dark Matter with a Transmon-Based Single Microwave Photon Counter

We report an axion dark matter search with a haloscope equipped with a microwave photon counter. The haloscope is a tunable high quality factor three-dimensional microwave cavity placed in a magnetic field. The photon counter, operated cyclically, maps an incoming microwave photon onto the state of a superconducting transmon qubit. The measurement protocol continuously monitors the power emitted by the haloscope cavity as well as the dark count background and enables tuning of the cavity frequency to probe different axion masses. With this apparatus, we enhance by a factor of 20 the search speed that can be reached with quantum-limited linear amplifiers and set a new standard for probing the existence of axions with resonant detectors above 5 GHz. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗