Search NASASearch

SEARCH · Search NASA

Results for “backup generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

V2XConnect: Harmonizing the Landscape of Bidirectional Charging Codes, Standards, and Communication Protocols

The utility grid is constantly evolving with new generation sources and diverse loads from backup generators, backup batteries, rooftop photovoltaics (PV), and flexible charging loads. Each of these technologies presents consumers with an opportunity to work with their local utility to promote grid stability, reliability, and affordability. Through a wide range of programs, utilities are incentivizing the use of these resources to benefit the grid. However, especially for devices with inverters that supply power back to the grid, it is important that these assets comply with local grid codes to ensure human safety, power quality, and grid reliability. One of the most promising of these new technologies is the bidirectional electric vehicle (EV) coupled with bidirectional electric vehicle supply equipment (EVSE). This report introduces the technologies that enable bidirectional charging and how these systems operate. It then outlines the necessary interconnection codes and industry standards that govern the operations of grid-tied inverters, including those in bidirectional charging. A key challenge is then outlined from the complex landscape of communication protocols and proprietary systems designed to coordinate these grid assets. Finally, a single gateway solution is proposed to harmonize communications between all assets across an entire site for a cohesive response to grid codes and utility programs that is flexible enough to support a range of market options.

33 ADVANCED PROPULSION SYSTEMS

District-Scale Analysis of Electricity Load and Strategies to Improve Energy Reliability Using Prototype District Models

Projected increases in electricity demand in the U.S. highlight the urgent need for effective load management to ensure grid reliability. As the building sector accounts for approximately 75% of electricity usage, enhancing energy efficiency and flexibility in this sector is crucial. Adopting district-level approaches offers significant advantages over traditional individual building analyses by enabling shared infrastructure and economies of scale. To navigate the data and computational challenges associated with modeling energy at the district level, prototype district models have been proposed as holistic, system-level solutions that capture complex interactions within typical configurations. This study presents these models as a reference tool for analyzing district-scale energy systems across various climate zones in the U.S. Developed with input from stakeholders, these models integrate varied building characteristics, inter-building connections, and energy system interactions. A case study utilizing the Urban Edge prototype district model, implemented on the URBANopt™ platform, evaluates multiple demand scenarios and the impact of distributed energy resources such as fuel-fired backup generators, photovoltaic systems, and batteries. Findings suggest that while new electric systems can significantly reduce annual energy use, they may also elevate peak electricity loads, with a notable 43% increase in heating-dominant climate zone 5B. The optimal backup power solutions vary based on location, influenced by factors such as utility rates and incentives. For example, PV and batteries perform well in high-cost regions like New York City, while diesel backup generators are more suitable for backup needs in climate zone 3A, such as Atlanta. Thus, this research highlights the importance of prototype district models for future district-scale energy planning.

24 POWER TRANSMISSION AND DISTRIBUTION

SCRES Energy Quest Workshop (Technical Report)

Energy Quest: Sitka’s Path to 2050 is a game based public engagement tool developed as part of the Sitka Community Renewable Energy Strategy and the U.S. Department of Energy’s Energy Transitions Initiative Partnership Project Cohort 3. Designed for Sitka’s isolated island microgrid, which is powered primarily by hydropower and depends on imported diesel for backup, the game translated complex long term energy planning questions into an interactive format. In facilitated workshops, residents built energy roadmaps to 2050, explored tradeoffs, and expressed priorities around four themes: affordability, reliability, self sufficiency, and innovation. Across sessions, participants showed strong support for increasing local self sufficiency and resilience, even when this required balancing near term affordability with long term investments. They emphasized reducing dependence on imported diesel, making better use of existing hydropower, and considering new renewable generation such as solar, wind, and additional hydropower. Survey and game responses also highlighted interest in using surplus hydropower to support new industries, expanding electrification of heating and transportation, and exploring emerging technologies and green fuels. The report organizes these findings into four scenario themes to guide Sitka’s 2050 energy planning. Affordability focuses on managing rate impacts, efficiency, and conservation. Reliability addresses diversified generation, backup power, and energy security. Self sufficiency emphasizes distributed generation and reduced reliance on imported fuels. Innovation explores new technologies, marine based energy solutions, and low carbon fuels. By grounding future planning in these community derived themes, Energy Quest shows how a game based approach can make technical energy planning more accessible and inclusive for remote communities. For questions about the game board and piece production email Dr. Sarah Troise (sarah.troise@pnnl.gov)

29 ENERGY PLANNING, POLICY, AND ECONOMY

Project Planning for Community Resilience: Aquinnah and Chilmark, Massachusetts

This report presents the findings of an energy system planning study for the towns of Aquinnah and Chilmark, MA, on the island of Martha’s Vineyard, conducted under the U.S. Department of Energy ETIPP program. The study used the DER-CAM model to optimize the deployment of PV and battery microgrids to enhance energy resilience against power outages, particularly winter storms. Key findings show that PV is highly cost-effective and delivers net annual savings. However, due to limited rooftop space and low winter solar output, PV and battery storage alone cannot support the full critical load during outages. Solutions incorporating conventional backup generators were found to be more economically viable for achieving 100% critical load support.

29 ENERGY PLANNING, POLICY, AND ECONOMY

Hybrid Powered Command Trailers Cost-Benefit Analysis Tool: User Guide and Examples

U.S. Forest Service (USFS) wildfire base camps use portable power for electrical needs, including yurts and trailers from which logistics staff work during the incident. These yurts and trailers are conventionally powered by portable diesel generators. Hybrid portable power systems consisting of a combination of solar photovoltaics (PV), battery energy storage systems (BESS), and/or backup diesel generators have been used in recent years and were piloted by the National Technology and Development Program (NTDP) on incidents in fall 2024 as part of NTDP's Portable Power Project. As part of that project, this work included the development of two Excel-based tools and two reports explaining the tools. The first tool, the Incident Energy Systems Model, is an Excel-based tool that models the power output of hybrid portable power systems powering yurts and/or trailers at fire camps over a typical day. The associated report (published separately) outlines a user guide for the model and walks through two scenarios. The two scenarios are 1) trailers powered by rooftop solar PV, batteries, and a back-up diesel generator, and 2) trailers powered by ground mount solar PV, batteries, and a back-up diesel generator. The second tool is a high-level cost-benefit analysis of the same two types of portable power systems, and is location independent.

14 SOLAR ENERGY

Incident Energy Systems Model: User Guide and Examples

U.S. Forest Service (USFS) wildfire base camps use portable power for electrical needs, including yurts and trailers from which logistics staff work during the incident. These yurts and trailers are conventionally powered by portable diesel generators. Hybrid portable power systems consisting of a combination of solar photovoltaics (PV), battery energy storage systems (BESS), and/or backup diesel generators have been used in recent years and were piloted by the National Technology and Development Program (NTDP) on incidents in fall 2024 as part of NTDP's Portable Power Project. As part of that project, this work included the development of two Excel-based tools and two reports explaining the tools. The first tool, the Incident Energy Systems Model, is an Excel-based tool that models the power output of hybrid portable power systems powering yurts and/or trailers at fire camps over a typical day.

14 SOLAR ENERGY

Modeling Framework for Data Center

This chapter highlights the critical need for advanced modeling of data centers due to their rapidly increasing energy consumption and impact on grid reliability. Driven by the demand for AI applications, data centers are projected to consume a significant portion of US energy by 2028, putting stress on an already challenged power grid. The chapter emphasizes the importance of "fast" time-scale models to understand the dynamic interactions between data centers and the grid, especially given the rapid power fluctuations of AI workloads. It outlines a modeling framework that includes both offline and real-time EMT domain simulations, detailing the necessary representations for various components like utility interfaces, transformers, IT loads, UPS, cooling loads, Battery Energy Storage Systems (BESS), generators, protection systems, and higher-level control systems. While standard simulation tools like PSCAD offer basic models, custom development is often required to accurately capture the unique and fast-changing behaviors of modern data centers. The chapter also discusses key metrics and test cases for validating these models, focusing on transient load responses, protection relay coordination, and demand flexibility. Finally, it addresses the challenges of modeling large-scale data centers, such as computational complexity and the trade-off between model fidelity and practicality, suggesting hybrid modeling approaches as a solution. The overarching goal is to create a robust framework that helps assess data center impacts on grid stability, identify vulnerabilities, and inform the development of standards for reliable integration of these large loads into the bulk power system.

25 ENERGY STORAGE

Techno-economic implications and cost of forecasting errors in solar PV power production using optimized deep learning models

Accurate solar Photovoltaic (PV) power forecasting is important for enhancing both the performance and economic feasibility of PV systems. This study evaluates several deep learning models, including Dense Neural Networks (DNN), Long Short-Term Memory (LSTM), Convolutional Neural Networks (CNN), and a hybrid LSTMCNN model, for predicting PV power production one day in advance. Prior to optimization, the models exhibited relatively high errors, with the best model (DNN) achieving a Root Mean Square Error (RMSE) of 31.13 kW and a coefficient of determination (R 2 ) of 62.15 %. After employing Bayesian optimization, the LSTM-CNN model demonstrated the best performance, with the RMSE reduced to 9.79 kW and R 2 improved to 97.62 %, showcasing significant enhancement in predictive accuracy. Here, the economic evaluation considered three cases: rewards for underestimation (0.08 USD/kWh), no rewards, and penalties for both over-and underestimation (120 % of the utility tariff). In the rewards scenario, the LSTM-CNN model reduced the Levelized Cost of Electricity (LCOE) by 4 %, while in the penalty scenario, a backup diesel generator would have increased the LCOE by 49 %. Additionally, the LSTM-CNN model minimized financial losses, achieving the lowest penalties and maximizing net cash flow compared to other models, demonstrating its overall technical and economic superiority.

Deep learning

Resilience Strategies to Ensure Water Supply Continuity During Extended Grid Outages

The towns of Edgartown, Oak Bluffs and Tisbury, on the island of Martha’s Vineyard, MA, are concerned about the effect of prolonged grid outages on continuity of their water supply. Water pumping stations operated by the water utilities that currently serve each of the towns currently have backup power generation that can support water delivery for up to one week during peak water demand periods. Sandia advised on options to extend water supply to two weeks.

Mammoli, Andrea Alberto [Sandia National Laborator

Wind power systems for individual applications

A small windpower system is described which is suitable for electrifying a house. The self-contained unit consists of a two kilowatt wind driven generator, a set of 19 storage batteries, a small dc to ac inverter, and a gasoline generator for use as an emergency backup system in case of prolonged calm periods. Cost effectiveness of the electricity generated by this windmill system comes out to about 15 cents per kilowatt hour - assuming a 10 year life for the batteries and a 20 year life for the other components. Some other small windpower systems are also described, and it is shown that a windpowered generator in the 15- to 25-kilowatt output range coupled to a direct heated water storage system is able to heat a typical New England home.

Clews, H. M.

The power reliability event simulator tool (PRESTO): A novel approach to distribution system reliability analysis and applications

The growing interest in onsite solar photovoltaic and energy storage systems is partially motivated by customer concerns regarding grid reliability. However, accurately assessing the effectiveness of PVESS in mitigating these interruptions requires a comprehensive understanding of location-specific outage patterns and the ability to simulate realistic scenarios. To address the gap, we introduce the Power Reliability Event Simulation TOol (PRESTO), the first publicly available tool that simulates location-specific power interruptions at the county level. PRESTO allows for a more realistic assessment of system reliability by considering the unpredictability and location-specific patterns of power interruptions. We applied PRESTO in a case study of a single-family home across three U.S. counties, examining the performance of a solar photovoltaic system with 10kWh of battery storage during short-duration power interruptions. Our findings show that this system reliably met 93% of energy demand for essential non-heating and cooling loads, fully serving these loads in 84% of events, despite the constraints of daily time-of-use bill management which limits the battery's state-of-charge reserve. However, when heating and cooling loads were included, system performance decreased significantly, with only 70% of demand met and full service in 43% of events. These results highlight the challenges of using solar photovoltaic and energy storage systems for short-duration outages, emphasizing the need to consider factors like battery size and grid charging strategies to improve reliability. Our study demonstrates the practical applications of PRESTO, providing valuable insights into potential mitigation strategies including grid charging and optimizing battery size.

14 SOLAR ENERGY

Assessment of Energy Technology Options for the Island of Molokai, Hawaii: Analysis of Floating Solar, Pumped Storage Hydropower, and Backup Energy Systems

This report documents analysis done by researchers at the National Laboratory of the Rockies and Pacific Northwest National Laboratory to evaluate the potential for and explore project concepts of electricity generation and storage additions on the island of Molokai, Hawaii, as identified in the Community Energy Resilience Action Plan (CERAP) by the Molokai Clean Energy Hui (MCEH), Sustainable Molokai, and the Hawaii Natural Energy Institute (HNEI). These electricity generation and storage additions include distributed photovoltaics (PV), battery energy storage, and generators for critical facilities on the island that can provide backup energy to the facilities during grid disruptions and outages, a floating PV (FPV) system on Kualapuu Reservoir, and pumped storage hydropower (PSH) systems scaled to act as a significant or primary source of energy storage on the Molokai grid.

13 HYDRO ENERGY

Assessment of Energy Technology Options for the Island of Molokai, Hawaii: Analysis of Floating Solar, Pumped Storage Hydropower, and Backup Energy Systems [Slides]

This presentation summarizes analysis done by researchers at the National Laboratory of the Rockies and Pacific Northwest National Laboratory to evaluate the potential for and explore project concepts of electricity generation and storage additions on the island of Molokai, Hawaii, as identified in the Community Energy Resilience Action Plan (CERAP) by the Molokai Clean Energy Hui (MCEH), Sustainable Molokai, and the Hawaii Natural Energy Institute (HNEI). These electricity generation and storage additions include distributed photovoltaics (PV), battery energy storage, and generators for critical facilities on the island that can provide backup energy to the facilities during grid disruptions and outages, a floating PV (FPV) system on Kualapuu Reservoir, and pumped storage hydropower (PSH) systems scaled to act as a significant or primary source of energy storage on the Molokai grid. This presentation accompanies the full technical report published under the same title.

14 SOLAR ENERGY

Voltage Service Limits Smart Contract Using Distributed Ledger Technology for Electrical Utility Grid with Customer-Owned Generator

Modern electrical grids face growing stability risks from customer-owned generators, especially at points of common couplings (PCCs). Disruptive behavior from power-electronic sources can cause protective relays to isolate problematic generators, making measurement integrity critical. This article presents a distributed ledger technology (DLT) approach that uses smart contracts to evaluate PCC voltage measurements and trigger backup breaker operations. The approach is framed as a verifiable, multi-organization attestation and audit layer, not as a real-time control security mechanism. In the proposed architecture, voltage measurements from a hardware protective relay are anchored on a DLT through the Cyber Grid Guard (CGG) system for attestation by both the grid utility and customer-owned generator. A Voltage Service Limits (VSLs) smart contract evaluates the on-chain measurements against allowable phase-voltage limits derived from the ANSI C84.1 standard. The framework is validated in a hardware-relay-in-the-loop test bed under sustained-undervoltage, sustained-overvoltage, and transient line-to-line fault scenarios. The results show that the VSL smart contract can process these measurements and issue backup breaker actions consistent with the defined service-limit criteria, demonstrating the DLT potential as a verifiable audit layer at the PCC that complements primary protection.

cyber security

Radiation protection and instrumentation

Radiation was found not to be an operational problem during the Apollo program. Doses received by the crewmen of Apollo missions 7 through 17 were small because no major solar-particle events occurred during those missions. One small event was detected by a radiation sensor outside the Apollo 12 spacecraft, but no increase in radiation dose to the crewmen inside the spacecraft was detected. Radiation protection for the Apollo program was focused on both the peculiarities of the natural space radiation environment and the increased prevalence of manmade radiation sources on the ground and onboard the spacecraft. Radiation-exposure risks to crewmen were assessed and balanced against mission gain to determine mission constraints. Operational radiation evaluation required specially designed radiation detection systems onboard the spacecraft in addition to the use of satellite data, solar observatory support, and other liaison. Control and management of radioactive sources and radiation-generating equipment was important in minimizing radiation exposure of ground-support personnel, researchers, and the Apollo flight and backup crewmen.

J. Vernon Bailey

Digital Grid Twin–Direct Communication Scheme Test Bed for Assessing Relay-to-Relay Radio Antenna and Optical Fiber Performance and Misoperations

This study introduces a novel “Digital Grid Twin–Direct Communication Scheme” test bed. This advanced platform evaluates point-to-point communication between transmitter and receiver relays with optical fiber and radio omnidirectional antenna systems, implemented at the Advanced Protection lab in the Grid Research Innovation and Development Center at Oak Ridge National Laboratory. The increased diversity of energy sources has led to more protective relay misoperations. In North America, microgrid protection schemes now use point-to-point communication along distribution lines between relays to implement advanced logic in nonradial grids that include both high- and low-inertia generators. This trend challenges utilities to minimize misoperations while ensuring rapid fault clearance and accurate selectivity coordination between primary and backup relays. This study assesses relay-to-relay communication schemes by introducing an advanced testing platform based on a digital grid twin protection test bed using a synchronized time source system. The platform evaluates the communication system using radio antennas or optical fiber links by integrating protective relays that operate breakers within the digital twin and record relay events and communication signals. In the experiments, transmitter and receiver relays were configured with inverse time overcurrent and breaker trip detection logic to assess the total time of the communication protection schemes based on the sum of the relay protection element operating time, radio latency, propagation delay, baud rate delay, and relay processing time. These delays were derived from recorded relay events and communication signals from the interface of a real-time simulator set as a digital grid twin. The test bed successfully simulated various electrical faults along a distribution line while ensuring effective and reliable point-to-point communication between transmitter and receiver relays. The radio antenna communication system exhibited latency because of the radio. This latency depends on the baud rate setting and type of radio application; in general, the higher the baud rate, the lower the radio latency. The measured radio latency (for Mirrored Bits with an encryption card at 9,600 bps) was about 9–10 ms. Additionally, calculated propagation delay per mile for radio antennas and optical fiber was 5.36 µs/mi and 8.04 µs/mi, respectively. Optical fiber communication did not demonstrate radio latency. Instead, the protection element operating time depends mainly on the protection logic function set in the relay, and the relay processing time depends on the processing rate of the relay in samples per power system cycle.

24 POWER TRANSMISSION AND DISTRIBUTION

Terrestrial laser scanning data (Levels 0 and 1) for Pasoh, Malaysia, Sep 2024

This data package contains data from terrestrial laser scanning (TLS) at the Pasoh Forest Reserve, Malaysia. The Pasoh Forest Reserve is a facility of the Forest Research Institute Malaysia, and contains evergreen lowland dipterocarp forest. The Next-Generation Ecosystem Experiments Tropics (NGEE-Tropics) study areas at Pasoh were established to study how different species respond to climatic variation and soil water availability. Two study areas were chosen representing different topography and species. The TLS data archived here were collected to provide detailed, three-dimensional information about forest structure. Specifically, data were collected to allow tree-level characterization of woody structure and leaf area for 12 focal trees with FloraPulse and sap flux sensors, facilitating estimation of woody biomass and leaf area to allow upscaling of water content and transpiration data to the tree-level. Scan positions were not selected to provide consistent data for non-focal trees with the study areas. This data package contains the following data: - High-level files document further details of the campaign and data package: 1_CampaignSummary.csv provides details about the campaign and study site, 2_ScanAreasDetail.csv provides details about each separate scan area (groups of scans post-processed into a single point cloud), 3_TerrestrialLidarSensor.csv provides further technical details about the Riegl VZ-400i TLS sensor, TLS_CSV_dd.csv is a CSV Data Dictionary providing information about the fields in CSV files following the ESS-DIVE CSV File Formatting Guidelines Reporting Format, TLS_flmd.csv is a File Level Metadata file providing information about each file in the data package following the ESS-DIVE File Level Metadata Reporting Format, and README.txt is a text file describing the overall project and file structure. - Level 0 data are the raw data (.PROJ folders) as recorded by the Riegl VZ-400i TLS instrument before scan co-registration and post-processing with the Riegl's proprietary RiSCAN PRO software, which requires a license. - Level 1 data contain post-processed, co-registered data from each scan area. The "PointClouds" folder for each scan area contains a .las file with 1 cm resolution point cloud data exported from RiSCAN PRO. These are the main files likely to be of interest to most users and can be further processed with any software capable of manipulating .las files (e.g. Python, R CloudCompare). The "Project Information" folder contains log files from post-processing in RiSCAN PRO that may be of interest to users who want to see detailed records of post-processing, including all PDF reports generated by RiSCAN PRO. The "ScanPositions" folder contains information about the final position of all TLS scans, after post-processing, in multiple formats. The file ScanPositions_*.csv provides final geo-referenced scan positions, and the file SOP_backup_*.csv can be used in RiSCAN PRO to restore the co-registered scan positions if users wish to re-process raw data (Level 0 .PROJ folders) with RiSCAN PRO software (e.g., subsample to a different resolution, exclude a certain scan position, or apply different filters on reflectance or deviation values) without redoing time-consuming co-registration steps.

54 ENVIRONMENTAL SCIENCES