Search NASA⌕ Search

SEARCH · Search NASA

Results for “bactericidal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Preliminary flight prototype potable water bactericide system

The development, design, and testing of a preliminary flight prototype potable water bactericide system are described. The system is an assembly of upgraded canisters composed of: (1) A biological filter; (2) an activated charcoal and ion exchange resin canister; (3) a silver chloride canister, (4) a deionizer, (5) a silver bromide canister with a partial bypass, and (6) mock-up instrumentation and circuitry. The system exhibited bactericidal activity against 10 to the 9th power Pseudomonas aeruginosa and/or Type IIIa, and reduced Bacillus subtilis by up to 5 orders of magnitude in 24 hours at ambient temperatures with a 1 ppm silver ion dose. Four efficacy tests were performed with a AgBr canister dosing anticipated fuel cell water. Tests show that a 0.05 ppm silver ion dose was bactericidal against 3 plus or minus 1 x 10 to the 9th power (5 plus or minus 1 x 10,000/ml Pseudomonas aeruginosa and/or Type IIIa in 15 minutes or less.

Jasionowski, W. J.↗

Silver ion bactericide system

Description of a preliminary flight prototype system which uses silver ions as the bactericide to preserve sterility of the water used for human consumption and hygiene in the Space Shuttle Orbiter. The performance of silver halide columns for passively dosing fuel cell water with silver ions is evaluated. Tests under simulated Orbiter mission conditions show that silver ion doses of 0.05 ppm are bactericidal for Pseudomonas aeruginosa and Type IIIa, the two bacteria found in Apollo potable water systems. The design of the Advance Prototype Silver Ion Water Bactericide System now under development is discussed.

Jasionowski, W. J.↗

Potable water bactericide agent development

The results are summarized of the work performed for the development and evaluation of a bactericide agent/system concept capable of being used in the space shuttle potable water system. The concept selected for evaluation doses fuel cell water with silver ions before the water is stored and used, by passing this water through columns packed with silver chloride and silver bromide particles, respectively. Four simulated space shuttle potable water system tests, each of seven days duration, were performed to demonstrate that this concept is capable of delivering sterile water even though 3 + or - 1 x 10 to the 9th power Type IIIa or Pseudomonas aeruginosa bacteria, two types which have been found in the Apollo potable water system, are purposely injected into the system each day. This result, coupled with the fact that silver ions do not have to be periodically added to the stored water, indicates that this concept is superior to the chlorine and iodine techniques used on Apollo.

Hurley, T. L.↗

Residual water bactericide monitor development program

A silver-ion bactericidal monitor is considered for the Space Shuttle Potable Water System. Potentiometric measurement using an ion-selective electrode is concluded to be the most feasible of available techniques. Four commercially available electrodes and a specially designed, solid-state, silver-sulfide electrode were evaluated for their response characteristics and suitability for space use. The configuration of the solid-state electrode with its Nernstian response of 10 to 10,000 ppb silver shows promise for use in space. A pressurized double-junction reference electrode with a quartz-fiber junction and a replaceable bellows electrolyte reservoir was designed verification-tested, and paired with a solid-state silver-sulfide electrode in a test fixture.

Source record↗

Advance prototype silver ion water bactericide system

An advance prototype unit was designed and fabricated to treat anticipated fuel cell water. The unit is a single canister that contains a membrane-type prefilter and a silver bromide contacting bed. A seven day baseline simulated mission test was performed; the performance was satisfactory and the effluent water was within all specifications for potability. After random vibrations another seven day simulated mission test was performed, and results indicate that simulated launch vibrations have no effects on the design and performance of the advanced prototype. Bench tests and accelerated breadboard tests were conducted to define the characteristics of an upgraded model of the advance prototype unit which would have 30 days of operating capability. A preliminary design of a silver ion generator for the shuttle orbiter was also prepared.

Jasionowski, W. J.↗

Development of an automated potable water bactericide monitoring unit

A monitor unit has been developed that permits the direct determination of the level of elemental iodine, used for microbiological control, in a spacecraft potable water supply system. Salient features of unit include low weight, volume and maintenance requirements, complete automatic operation, no inflight calibration, no expendables (except electrical current) and high accuracy and precision. This unit is capable of providing a signal to a controller that, in turn, automatically adjusts the addition rate of iodine to the potable water system so that a predetermined level of iodine can be maintained. In addition, the monitor provides a reading whereby the crewman can verify that the proper amount of iodine (within a range) is present in the water. A development history of the monitor is presented along with its design and theory of operation. Also presented are the results generated through testing of the unit in a simulated Shuttle potable water system.

Walsh, J. M.↗

Bactericidal effect of hydrogen peroxide on spacecraft isolates

Results are presented for an experimental study designed to assess the effect of hydrogen peroxide on both sporeforming and nonsporeforming spacecraft isolates as an initial step in determining its suitability for microbiological decontamination of certain United States spacecraft. Survivor data were obtained for eight bacterial isolates (six sporeformers and two nonsporeformers) recovered before launch Mariner 9 and exposed to concentrations of 3, 10, and 15% hydrogen peroxide. The effects of various concentrations of hydrogen peroxide on the spores are presented in tabular form, along with the percentage of survival of nonsporeformers exposed to hydrogen peroxide. No viable vegetative cells were recovered after a 10-min exposure time to any of the three concentration of hydrogen peroxide.

Wardle, M. D.↗

Fungi and Bacteria

Spacecraft equipment is usually protected from fungi and bacteria by incorporating a fungicide-bactericide in the material, by a fungicide-bactericide spray, or by reducing the relative humidity to a degree where growth will not take place. A unique method to protect delicate, expensive bearings in equipment was to maintain a pressure (with dry air or nitrogen) slightly above the outside atmosphere (few millibars) within the working parts of the equipment, thus preventing fungi from entering equipment.

Glenn E Daniels↗

The potable water system in Skylab

Description of the medical requirements, development, system operation, and in-flight performance of the Skylab potable water system. Emphasized is the description of the unique features involving new space-flight concepts, procedures, and design incorporated in Skylab. The water supplied to the three Skylab missions was preloaded in stainless-steel tanks. These tanks were fitted with positive expulsion stainless-steel bellows. In-flight iodination of the water, for bacterial control, was accomplished as required. An in-flight bactericide monitor was used periodically to determine the level of bactericide in the water. Prior to the delivery of the water to the crewmen for consumption, the water was passed through a cation exchange resin for metallic ion removal and then heated for food reconstitution or chilled for drinking.

R. L. Sauer↗

Spacecraft sterilization.

Spacecraft sterilization is a vital factor in projects for the successful biological exploration of other planets. The microorganisms of major concern are the fungi and bacteria. Sterilization procedures are oriented toward the destruction of bacterial spores. Gaseous sterilants are examined, giving attention to formaldehyde, beta-propiolactone, ethylene oxide, and the chemistry of the bactericidal action of sterilants. Radiation has been seriously considered as another method for spacecraft sterilization. Dry heat sterilization is discussed together with the effects of ethylene oxide decontamination and dry heat sterilization on materials.

Kalfayan, S. H.↗

Polyelectrolytes with high charge density

Polymers can be used as flocculants to clarify residential and industrial water supplies and as bactericidal and fungicidal agents. They can be used in preparation of electroconductive photocopy papers, to improve living cell adhesion to glass or plastic, and as anticancer agents.

Rembaum, A.↗

Development of an improved membrane for a vapor diffusion water recovery process

Recovery of potable water from urine on manned space missions of extended duration was the objective of work aimed at the improvement of membrane performance for the vapor diffusion process (VDR). Kynar, Teflon, PVC, and polysulfone candidate membranes were evaluated from chemical, thermal, mechanical, and fabricating standpoints to determine their suitability for operation in the VDR pervaporation module. Pervaporation rates and other performance characteristics were determined in a breadboard pervaporator test rig. Kynar and Teflon membranes were demonstrated to be chemically stable at pervaporation temperatures in urine pretreated with chromic acid bactericide. The separation of the pervaporator and condenser modules, the use of a recirculating sweep gas to conduct pervaporate to the condenser, and the selection of a hollow fiber membrane configuration for pervaporator module design is recommended as a result of the investigation.

Rich, T. R.↗

Techniques of biological contamination avoidance by atmospheric probes

The likelihood of biologically contaminating a planet by an atmospheric probe has a low probability of occurring if the probe is kept biologically clean during terrestrial operations and if the structure remains in tact until the planets life zone is completely penetrated. High standards of cleanliness, monitoring and estimating for remedial actions must be maintained in a probe program. It is not a foregone conclusion, however, that heat sterilization needs to be employed. The use of several techniques having a good potential for lower probe costs are available and appear adequate to render a probe sterile within acceptable bounds. The techniques considered to be satisfactory for minimizing microbial load include: (1) combined heat (at 95-105 C) and gamma radiation; (2) short term heating at 105 + or - 5 C to inactivate all vegetative microbes; (3) irradiation routinely by ultraviolet light; (4) wiping by a bactericidal agent with or without a penetrant; and (5) cleanliness alone.

Defrees, R. E.↗

Water system microbial check valve development

A residual iodine microbial check valve (RIMCV) assembly was developed and tested. The assembly is designed to be used in the space shuttle potable water system. The RIMCV is based on an anion exchange resin that is supersaturated with an iodine solution. This system causes a residual to be present in the effluent water which provides continuing bactericidal action. A flight prototype design was finalized and five units were manufactured and delivered.

Colombo, G. V.↗