Search NASA⌕ Search

SEARCH · Search NASA

Results for “balance training”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Balancing Training Techniques for Flight Controller Certification

Training of ground control teams has been a difficult task in space operations. There are several intangible skills that must be learned to become the steely eyed men and women of mission control who respond to spacecraft failures that can lead to loss of vehicle or crew if handled improperly. And as difficult as training is, it can also be costly. Every day, month or year an operator is in training, is a day that not only they are being trained without direct benefit to the organization, but potentially an instructor or mentor is also being paid for hours spent assisting them. Therefore, optimization of the training flow is highly desired. Recently the Expedition Division (DI) at Johnson Space Flight Center has recreated their training flows for the purpose of both moving to an operator/specialist/instructor hierarchy and to address past inefficiencies in the training flow. This paper will discuss the types of training DI is utilizing in their new flows, and the balance that has been struck between the ideal learning environments and realistic constraints. Specifically, the past training flow for the ISS Attitude Determination and Control Officer will be presented, including drawbacks that were encountered. Then the new training flow will be discussed and how a new approach utilizes more training methods and teaching techniques. We will look at how DI has integrated classes, workshops, checkouts, module reviews, scenarios, OJT, paper sims, Mini Sims, and finally Integrated Sims to balance the cost and timing of training a new flight controller.

Gosling, Christina↗

Estimation of Optimum Stimulus Amplitude for Balance Training using Electrical Stimulation of the Vestibular System

Sensorimotor changes such as posture and gait instabilities can affect the functional performance of astronauts after gravitational transitions. Sensorimotor Adaptability (SA) training can help alleviate decrements on exposure to novel sensorimotor environments based on the concept of 'learning to learn' by exposure to varying sensory challenges during posture and locomotion tasks (Bloomberg 2015). Supra-threshold Stochastic Vestibular Stimulation (SVS) can be used to provide one of many challenges by disrupting vestibular inputs. In this scenario, the central nervous system can be trained to utilize veridical information from other sensory inputs, such as vision and somatosensory inputs, for posture and locomotion control. The minimum amplitude of SVS to simulate the effect of deterioration in vestibular inputs for preflight training or for evaluating vestibular contribution in functional tests in general, however, has not yet been identified. Few studies (MacDougall 2006; Dilda 2014) have used arbitrary but fixed maximum current amplitudes from 3 to 5 mA in the medio-lateral (ML) direction to disrupt balance function in healthy adults. Giving this high level of current amplitude to all the individuals has a risk of invoking side effects such as nausea and discomfort. The goal of this study was to determine the minimum SVS level that yields an equivalently degraded balance performance. Thirteen subjects stood on a compliant foam surface with their eyes closed and were instructed to maintain a stable upright stance. Measures of stability of the head, trunk, and whole body were quantified in the ML direction. Duration of time they could stand on the foam surface was also measured. The minimum SVS dosage was defined to be that level which significantly degraded balance performance such that any further increase in stimulation level did not lead to further balance degradation. The minimum SVS level was determined by performing linear fits on the performance variable at different stimulation levels. Results from the balance task suggest that there are inter-individual differences and the minimum SVS amplitude was found to be in the range of 1 mA to 2.5 mA across subjects. SVS resulted in an average decrement of balance task performance in the range of 62%-73% across different measured variables at the minimum SVS amplitude in comparison to the control trial (no stimulus). Training using supra-threshold SVS stimulation is one of the sensory challenges used for preflight SA training designed to improve adaptability to novel gravitational environments. Inter-individual differences in response to SVS can help customize the SA training paradigms using minimal dosage required. Another application of using SVS is to simulate acute deterioration of vestibular sensory inputs in the evaluation of tests for assessing vestibular function.

Goel, R.↗

Development of an Integrated Countermeasure Device for Long Duration Space Flight and Exploration Missions

Musculoskeletal, cardiovascular, and sensorimotor deconditioning have been observed consistently in astronauts and cosmonauts following long-duration spaceflight. Studies in bed rest, a spaceflight analog, have shown that high intensity resistive or aerobic exercise attenuates or prevents musculoskeletal and cardiovascular deconditioning, respectively, but complete protection has not been achieved during spaceflight. Exercise countermeasure hardware used during earlier International Space Station (ISS) missions included a cycle ergometer, a treadmill, and the interim resistive exercise device (iRED). Effectiveness of the countermeasures may have been diminished by limited loading characteristics of the iRED as well as speed restrictions and subject harness discomfort during treadmill exercise. The Advanced Resistive Exercise Device (ARED) and the second generation treadmill were designed to address many of the limitations of their predecessors, and anecdotal reports from ISS crews suggest that their conditioning is better preserved since the new hardware was delivered in 2009. However, several countermeasure devices to protect different physiologic systems will not be practical during exploration missions when the available volume and mass will be severely restricted. The combined countermeasure device (CCD) integrates a suite of hardware into one device intended to prevent spaceflight-induced musculoskeletal, cardiovascular, and sensorimotor deconditioning. The CCD includes pneumatic loading devices with attached cables for resistive exercise, a cycle for aerobic exercise, and a 6 degree of freedom motion platform for balance training. In a proof of concept test, ambulatory untrained subjects increased muscle strength (58%) as well as aerobic capacity (26%) after 12-weeks of exercise training with the CCD (without balance training), improvements comparable to those observed with traditional exercise training. These preliminary results suggest that this CCD can concurrently improve musculoskeletal and cardiovascular conditioning in ambulatory subjects, but further work is required to validate its use as countermeasure to spaceflight-induced deconditioning.

Lee, S. M. C.↗

Treadmill Exercise with Increased Body Loading Enhances Post Flight Functional Performance

The goals of the Functional Task Test (FTT) study were to determine the effects of space flight on functional tests that are representative of high priority exploration mission tasks and to identify the key underlying physiological factors that contribute to decrements in performance. Ultimately this information will be used to assess performance risks and inform the design of countermeasures for exploration class missions. We have previously shown that for Shuttle, ISS and bed rest subjects functional tasks requiring a greater demand for dynamic control of postural equilibrium (i.e. fall recovery, seat egress/obstacle avoidance during walking, object translation, jump down) showed the greatest decrement in performance. Functional tests with reduced requirements for postural stability (i.e. hatch opening, ladder climb, manual manipulation of objects and tool use) showed little reduction in performance. These changes in functional performance were paralleled by similar decrements in sensorimotor tests designed to specifically assess postural equilibrium and dynamic gait control. The bed rest analog allows us to investigate the impact of axial body unloading in isolation on both functional tasks and on the underlying physiological factors that lead to decrements in performance and then compare them with the results obtained in our space flight study. These results indicate that body support unloading experienced during space flight plays a central role in postflight alteration of functional task performance. Given the importance of body-support loading we set out to determine if there is a relationship between the load experienced during inflight treadmill exercise (produced by a harness and bungee system) and postflight functional performance. ISS crewmembers (n=13) were tested using the FTT protocol before and after 6 months in space. Crewmembers were tested three times before flight, and on 1, 6, and 30 days after landing. To determine how differences in body-support loading experienced during inflight treadmill exercise impacts postflight functional performance, the loading history for each subject during inflight treadmill (T2) exercise was correlated with postflight measures of performance. Crewmembers who walked on the treadmill with higher pull-down loads had less decrement in postflight postural stability and dynamic locomotor control than those subjects who exercised with lighter loads. These data point to the importance of providing significant body loading during inflight treadmill exercise. This and the addition of specific balance training may further mitigate decrements in critical mission tasks that require dynamic postural stability and mobility. Inflight treadmill exercise provides a multi-disciplinary platform to provide sensorimotor, aerobic and bone mechanical stimuli benefits. Forward work will focus on the development of an inflight training system that will integrate aerobic, resistive and balance training modalities into a single interdisciplinary countermeasure system for exploration class missions.

Bloomberg, J. J.↗

Balance Devices Train Golfers for a Consistent Swing

As part of the effort to understand the effects of spaceflight on astronauts, NASA funded research that resulted in a commercial product to treat balance disorders. West Palm Beach, Florida-based Sports Therapy Inc. worked with the inventor to modify the technology, creating the Dynamic Balance System (DBS) for sports applications. DBS is now used by Professional Golfers' Association-owned facilities and golf academies to help players achieve an effective, balanced swing.

Source record↗

Inflight Treadmill Exercise Can Serve as Multi-Disciplinary Countermeasure System

The goals of the Functional Task Test (FTT) study were to determine the effects of space flight on functional tests that are representative of high priority exploration mission tasks and to identify the key underlying physiological factors that contribute to decrements in performance. Ultimately this information will be used to assess performance risks and inform the design of countermeasures for exploration class missions. We have previously shown that for Shuttle, ISS and bed rest subjects, functional tasks requiring a greater demand for dynamic control of postural equilibrium (i.e. fall recovery, seat egress/obstacle avoidance during walking, object translation, jump down) showed the greatest decrement in performance. Functional tests with reduced requirements for postural stability (i.e. hatch opening, ladder climb, manual manipulation of objects and tool use) showed little reduction in performance. These changes in functional performance were paralleled by similar decrements in sensorimotor tests designed to specifically assess postural equilibrium and dynamic gait control. The bed rest analog allows us to investigate the impact of axial body unloading in isolation on both functional tasks and on the underlying physiological factors that lead to decrements in performance and then compare them with the results obtained in our space flight study. These results indicate that body support unloading experienced during space flight plays a central role in postflight alteration of functional task performance. These data also support the concept that space flight may cause central adaptation of converging body-load somatosensory and vestibular input during gravitational transitions [1]. Therefore, we conclude that providing significant body-support loading during inflight treadmill along with balance training is necessary to mitigate decrements in critical mission tasks that require dynamic postural stability and mobility. Data obtained from space flight and bed rest support the notion that in-flight treadmill exercise, in addition to providing aerobic exercise and mechanical stimuli to the bone, also has a number of sensorimotor benefits by providing: 1) A balance challenge during locomotion requiring segmental coordination in response to a downward force. 2) Body-support loading during performance of a full-body active motor task. 3) Oscillatory stimulation of the otoliths and synchronized periodic foot impacts that facilitate the coordination of gait motions and tune the full-body gaze control system. 4) Appropriate sensory input (foot tactile input, muscle and tendon stretch input) to spinal locomotor central pattern generators required for the control of locomotion. Forward work will focus on a follow-up bed rest study that incorporates aerobic and resistance exercise with a treadmill balance and gait training system that can serve as an integrated interdisciplinary countermeasure system for future exploration class missions.

Bloomberg, J. J.↗

Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs

Crewmembers returning from long-duration space flight face significant challenges due to the microgravity-induced inappropriate adaptations in balance/ sensorimotor function. The Neuroscience Laboratory at JSC is developing a method based on stochastic resonance to enhance the brain s ability to detect signals from the balance organs of the inner ear and use them for rapid improvement in balance skill, especially when combined with balance training exercises. This method involves a stimulus delivery system that is wearable/portable providing imperceptible electrical stimulation to the balance organs of the human body. Stochastic resonance (SR) is a phenomenon whereby the response of a nonlinear system to a weak periodic input signal is optimized by the presence of a particular non-zero level of noise. This phenomenon of SR is based on the concept of maximizing the flow of information through a system by a non-zero level of noise. Application of imperceptible SR noise coupled with sensory input in humans has been shown to improve motor, cardiovascular, visual, hearing, and balance functions. SR increases contrast sensitivity and luminance detection; lowers the absolute threshold for tone detection in normal hearing individuals; improves homeostatic function in the human blood pressure regulatory system; improves noise-enhanced muscle spindle function; and improves detection of weak tactile stimuli using mechanical or electrical stimulation. SR noise has been shown to improve postural control when applied as mechanical noise to the soles of the feet, or when applied as electrical noise at the knee and to the back muscles.

Bloomberg, Jacob↗

Improving Early Adaptation Following Long Duration Spaceflight by Enhancing Vestibular Information

Crewmember adapted to the microgravity state may need to egress the vehicle within a few minutes for safety and operational reasons after g-transitions. The transition from one sensorimotor state to another consists of two main mechanisms: strategic and plastic-adaptive and have been demonstrated in astronauts returning after long duration space flight. Strategic modifications represent "early adaptation" -immediate and transitory changes in control that are employed to deal with short-term changes in the environment. If these modifications are prolonged then plastic-adaptive changes are evoked that modify central nervous system function, automating new behavioral responses. More importantly, this longer term adaptive recovery mechanism was significantly associated with their strategic ability to recover on the first day after return to Earth G. We are developing a method based on stochastic resonance (SR) to enhance information transfer by improving the brain's ability to detect vestibular signals especially when combined with balance training exercises for rapid improvement in functional skill, for standing and mobility. The countermeasure to improve post-flight balance and locomotor disturbances is a stimulus delivery system that is wearable/portable providing low imperceptible levels of white noise based binaural bipolar electrical stimulation of the vestibular system (stochastic vestibular stimulation, SVS). The techniques for improving signal detection using SVS may thus provide additional information to improve such strategic abilities and thus help in significantly reducing the number of days required to recover functional performance to preflight levels after long duration space flight. We have conducted a series of studies to document the efficacy of SVS stimulation on balance/locomotion tasks on unstable surfaces and motion tracking tasks during intra-vestibular system conflicts. In an initial study, we showed that SVS improved overall balance performance while standing on an unstable surface indicating that SVS may be sufficient to provide a comprehensive countermeasure approach for improving postural stability. In a second study, we showed that SVS improved locomotor performance on a treadmill mounted on an oscillating platform indicating that SVS may also be used to maximize locomotor performance during walking in unstable environments. In a third study, SVS was evaluated during an otolith-canal conflict scenario in a variable radius centrifuge at low frequency of oscillation (0.1 Hz) on both eye movements and perceptual responses (using a joystick) to track imposed oscillations. The variable radius centrifuge provides a selective tilting sensation that is detectable only by the otolith organs providing conflicting information from the canal organs of the vestibular system (intra-vestibular conflict). Results show that SVS significantly reduced the timing difference between both the eye movement responses as well as the perceptual tracking responses with respect to the imposed tilt sensations. These results indicate that SVS can improve performance in sensory conflict scenarios like that experienced during space flight. Such a SR countermeasure will act synergistically along with the pre-and in-flight adaptability training protocols providing an integrated, multi-disciplinary countermeasure capable of fulfilling multiple requirements making it a comprehensive and cost effective countermeasure approach to enhance sensorimotor capabilities following long-duration space flight.

Mulavara, Ajitkumar↗

Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs

Crewmembers returning from long-duration space flight face significant challenges due to the microgravity-induced inappropriate adaptations in balance/sensorimotor function. The Neuroscience Laboratory at JSC is developing a method based on stochastic resonance to enhance the brain's ability to detect signals from the balance organs of the inner ear and use them for rapid improvement in balance skill, especially when combined with balance training exercises. This method involves a stimulus delivery system that is wearable/portable and provides imperceptible electrical stimulation to the balance organs of the human body. Stochastic resonance (SR) is a phenomenon whereby the response of a nonlinear system to a weak periodic input signal is optimized by the presence of a particular non-zero level of noise. This phenomenon of SR is based on the concept of maximizing the flow of information through a system by a non-zero level of noise. Application of imperceptible SR noise coupled with sensory input in humans has been shown to improve motor, cardiovascular, visual, hearing, and balance functions. SR increases contrast sensitivity and luminance detection; lowers the absolute threshold for tone detection in normal hearing individuals; improves homeostatic function in the human blood pressure regulatory system; improves noise-enhanced muscle spindle function; and improves detection of weak tactile stimuli using mechanical or electrical stimulation. SR noise has been shown to improve postural control when applied as mechanical noise to the soles of the feet, or when applied as electrical noise at the knee and to the back muscles. SR using imperceptible stochastic electrical stimulation of the vestibular system (stochastic vestibular stimulation, SVS) applied to normal subjects has shown to improve the degree of association between the weak input periodic signals introduced via venous blood pressure receptors and the heart-rate responses. Also, application of SVS over 24 hours improves the long-term heart-rate dynamics and motor responsiveness as indicated by daytime trunk activity measurements in patients with multi-system atrophy, Parkinson s disease, or both, including patients who were unresponsive to standard therapy for Parkinson s disease. Recent studies conducted at the NASA JSC Neurosciences Laboratories showed that imperceptible SVS, when applied to normal young healthy subjects, leads to significantly improved balance performance during postural disturbances on unstable compliant surfaces. These studies have shown the benefit of SR noise characteristic optimization with imperceptible SVS in the frequency range of 0-30 Hz, and amplitudes of stimulation have ranged from 100 to 400 microamperes.

Bloomberg, Jacob↗

Improving Sensorimotor Adaptation Following Long Duration Space Flight by Enhancing Vestibular Information Transfer

Crewmember adapted to the microgravity state may need to egress the vehicle within a few minutes for safety and operational reasons after gravitational transitions. The transition from one sensorimotor state to another consists of two main mechanisms: strategic and plastic-adaptive and have been demonstrated in astronauts returning after long duration space flight. Strategic modifications represent "early adaptation" - immediate and transitory changes in control that are employed to deal with short-term changes in the environment. If these modifications are prolonged then plastic-adaptive changes are evoked that modify central nervous system function, automating new behavioral responses. More importantly, this longer term adaptive recovery mechanism was significantly associated with their strategic ability to recover on the first day after return to Earth G. We are developing a method based on stochastic resonance to enhance information transfer by improving the brain's ability to detect vestibular signals (Vestibular Stochastic Resonance, VSR) especially when combined with balance training exercises such as sensorimotor adaptability (SA) training for rapid improvement in functional skill, for standing and mobility. This countermeasure to improve detection of vestibular signals is a stimulus delivery system that is wearable/portable providing low imperceptible levels of white noise based binaural bipolar electrical stimulation of the vestibular system (stochastic vestibular stimulation). To determine efficacy of vestibular stimulation on physiological and perceptual responses during otolith-canal conflicts and dynamic perturbations we have conducted a series of studies: We have shown that imperceptible binaural bipolar electrical stimulation of the vestibular system across the mastoids enhances balance performance in the mediolateral (ML) plane while standing on an unstable surface. We have followed up on the previous study showing VSR stimulation improved balance performance in both ML and anteroposterior planes while stimulating in the ML axis only. We have shown the efficacy of VSR stimulations on enhancing physiological and perceptual responses of whole-body orientation during low frequency perturbations (0.1 Hz) on the ocular motor system using a variable radius centrifuge on both physiological (using eye movements) and perceptual responses (using a joystick) to track imposed oscillations. The variable radius centrifuge provides a selective tilting sensation that is detectable only by the otolith organs providing conflicting information from the canal organs of the vestibular system (intra-vestibular conflict). These results indicate that VSR can improve performance in sensory conflict scenarios like that experienced during space flight. We have showed the efficacy of VSR stimulation to improve balance and locomotor control on subjects exposed to continuous, sinusoidal lateral motion of the support surface while walking on a treadmill while viewing perceptually matched linear optic flow. We have shown the safety of short term continuous use of up to 4 hours of VSR stimulation and its efficacy in improving balance and locomotor function in Parkinson's Disease patients. This technique for improving vestibular signal detection may thus provide additional information to improve strategic abilities. We hypothesize that VSR stimulation will act synergistically with SA training to improve adaptability by increased utilization of vestibular information and therefore serve to optimize and personalize the SA countermeasure prescription. This forms the basis of its usefulness both as a training modality and further help in significantly reducing the number of days required to recover functional performance to preflight levels after long duration space flight.

Mulavara, A. P.↗

Development of an Integrated Countermeasure Device for Use in Long-Duration Space Flight

Prolonged weightlessness is associated with declines in musculoskeletal, cardiovascular, and sensorimotor health. Consequently, in-flight countermeasures are required to preserve astronaut health. We developed and tested a novel exercise countermeasure device (CCD) for use in spaceflight with the aim of preserving musculoskeletal and cardiovascular health along with an incorporated balance-training component. Additionally, the CCD features a compact footprint, and a low power requirement. Methods: After design and development of the CCD, we carried out a training study to test its ability to improve cardiovascular and muscular fitness in healthy volunteers. Fourteen male and female subjects (41.4+/-9.0 years, 69.5+/-15.4Kg) completed 12 weeks (3 sessions per week) of concurrent strength and endurance training on the CCD. Subjects were tested at baseline and after 12 weeks for 1-repetition max leg press strength (1RM), peak oxygen consumption (VO2peak), and isokinetic joint torque (ISO) at the hip, knee, and ankle. Additionally, we evaluated subjects after 6 weeks of training for changes in VO2peak and 1RM. Results: VO2peak and 1RM improved after 6-weeks, with additional improvements after 12 weeks (1.95+/-0.5, 2.28+/-0.5, 2.47+/-0.6 LY/min and 131.2+/-63.9,182.8+/-75.0, 207.0+/-75.0 Kg) for baseline, 6 weeks, and 12 weeks respectively. ISO for hip adduction, adduction, and ankle plantar flexion improved after 12 weeks of training (70.3+/-39.5, 76.8+/-39.2 and 55.7+/-21.7 N-m vs. 86.1+/-37.3, 85.1+/-34.3 and 62.1+/-26.4 N-m respectively). No changes were observed for ISO during hip flexion, knee extension, or knee flexion. Conclusions: The CCD is effective at improving cardiovascular fitness and isotonic leg strength in healthy adults. Further, the improvement in hip adductor and abductor torque provides support that the CCD may provide additional protection for the preservation of bone health at the hip.

Streeper, Tim↗

An Integrated Musculoskeletal Countermeasure Battery for Long-Duration Lunar Missions

During extended periods of skeletal unloading, losses in strength and density of the proximal femur will occur. In long-duration spaceflight, resistive exercise is used to replace the normal loads exerted on the spine and hip. At the present time, there is no conclusive evidence that hip bone loss has been prevented in this scenario. Our group has recently developed and clinically evaluated a multifunctional exercise system, the Combined Countermeasure Device (CCD). The CCD comprises a low-footprint Stuart Platform for lower-body resistance exercise and balance training, and a cardiovascular exercise bicycle. A consideration for resistance exercise was targeting of the hip abductor and adductor muscles, which attach directly at the hip and which should subject it to the largest loads. In our training study, we found that CCD exercise increased hip adductor and abductor strength, and modeling results suggest that this exercise exerts forces on the hip of approx. 4-6 body weights at 1g, compared to forces of approx.2.5 body weight y squatting exercise. In our current study, we hypothesize that abductor and adductor exercise will increase the density and strength of the proximal femur.

Lang, T. F.↗

Neuro-Vestibular Examination During and Following Spaceflight (Vestibular Health)

BACKGROUND Adaptation to microgravity during spaceflight causes neurological disturbances that are either directly or indirectly mediated by the vestibular system. These disturbances could include space motion sickness, spatial disorientation, and cognitive impairment, as well as changes in head-eye coordination, vestibulo-ocular reflexes, and control of posture and locomotion. Otolith-mediated reflex gains appear to adapt rapidly during spaceflight and after landing. However, animal studies have shown that structural modifications of the vestibular sensory apparatus develop during long-duration spaceflight. To date, no studies have characterized the severity of vestibular syndromes experienced by astronauts as a function of the duration of spaceflight or whether the effects are caused by changes at the peripheral end organs, midbrain, cerebellum, or vestibular cortex. OBJECTIVES We will investigate temporal vestibular changes in crewmembers of short, 6-month, and one-year missions to identify trends in adaptation of vestibular health and performance in orbit and after landing. We will also determine whether the vestibular organs and/or the central vestibular system undergo structural changes during long-duration exposure to microgravity, which could cause vestibular disorders when transitioning to a different gravitational environment. METHODS Recordings of eye, head, and body movements, as well as subjective reports of perception of motion, will be used to determine the presence of abnormal eye movements, dysmetria, motion sickness symptoms, and illusions of motion during head or body movements. This includes characterization of temporal trends in central compensation for vestibular (otolith) asymmetry. Pre-flight data will be collected 90 days before the flight. In-flight tests will be performed early in the mission and once every one or two months thereafter. Post-flight examinations will be performed on the following days after return (R) from the mission: R+0, R+4, R+9, and R+30. Ground-based control tests will be performed on healthy volunteers in the laboratory to estimate mean normative responses. CONTROL RESULTS Thirty-two healthy (non-astronaut) control subjects performed the same ground test procedures as planned for crewmembers. In addition to establishing a normative database, these data were used to calculate vestibular asymmetries from perceptual reports during unilateral centrifugation, oculomotor responses during visual-alignment tasks, vestibulo-ocular reflex gain during head-impulse tests, and body rotation during stepping tests. A significant correlation was observed between asymmetries of subjective visual vertical and verbal report during unilateral centrifugation. Another significant correlation was observed between the asymmetries of ocular alignment, vestibulo-ocular reflex gain, and body rotation. These findings in a healthy cohort may help us better understand changes in vestibular asymmetries in crewmembers during and following spaceflight. RELEVANCE If the observed symptoms in crewmembers are more deleterious after the year-long missions than those documented after 6-month missions, then relevant countermeasures will be required to maintain the health and operational performance of astronauts during longer missions. Depending on the etiology of the vestibular syndrome revealed by these tests, countermeasures will be proposed based on vestibular rehabilitation therapies currently used in patients with vestibular disorders, such as habituation, gaze stabilization, and/or balance training exercises. ACKNOWLEDGEMENT This work is supported by the NASA’s Human Research Program Human Health Countermeasures Element.

T R Macaulay↗

Neuro-Vestibular Examination During and Following Spaceflight (Vestibular Health)

BACKGROUND Adaptation to microgravity during spaceflight causes neurological disturbances that are either directly or indirectly mediated by the vestibular system. These disturbances can include space motion sickness, spatial disorientation, and cognitive impairment, as well as changes in head-eye coordination, vestibulo-ocular reflexes, and control of posture and locomotion. Otolith-mediated reflex gains appear to adapt rapidly during spaceflight and after landing. However, animal studies have shown that structural modifications of the vestibular sensory apparatus develop during long-duration spaceflight. To date, no studies have characterized the severity of vestibular syndromes experienced by astronauts as a function of the duration of spaceflight or whether the effects are caused by changes at the peripheral end organs, midbrain, cerebellum, or vestibular cortex. OBJECTIVES We will investigate temporal vestibular changes in crewmembers of short, 6-month, and one-year missions to identify trends in adaptation of vestibular health and performance in orbit and after landing. We will also determine whether the vestibular organs and/or the central vestibular system undergo structural changes during long-duration exposure to microgravity, which could cause vestibular disorders when transitioning to a different gravitational environment. METHODS Recordings of eye, head, and body movements, as well as subjective reports of perception of motion, will be used to determine the presence of abnormal eye movements, dysmetria, motion sickness symptoms, and illusions of motion during head or body movements. This includes characterization of temporal trends in central compensation for vestibular (otolith) asymmetry. Pre-flight data will be collected 90 days before launch. In-flight examinations will be performed early in the mission (Flight Days 1 and 30) and once every two or three months thereafter. Post-flight examinations will be performed on the following days after return (R) from the mission: R+0, R+4, R+9, and R+30. Ground-based control tests have been performed on healthy volunteers in the laboratory to estimate mean normative responses. RESULTS Data collection for this study is ongoing. Data processing techniques are being refined. Our eye tracking method for measuring three-dimensional eye movement takes advantage of modern computer vision software (OpenCV) and advances in the field of iris recognition to improve measurement of ocular-counterolling. RELEVANCE If the observed symptoms in crewmembers are more deleterious after the year-long missions than those documented after 6-month missions, then relevant countermeasures will be required to maintain the health and operational performance of astronauts during longer missions. Depending on the etiology of the vestibular syndrome revealed by these tests, countermeasures will be proposed based on vestibular rehabilitation therapies currently used in patients with vestibular disorders, such as habituation, gaze stabilization, and/or balance training exercises.

T R Macaulay↗

Neuro-Vestibular Examination During and Following Spaceflight (Vestibular Health)

BACKGROUND Adaptation to microgravity during spaceflight causes neurological disturbances that are either directly or indirectly mediated by the vestibular system. These disturbances can include space motion sickness, spatial disorientation, and cognitive impairment, as well as changes in head-eye coordination, vestibulo-ocular reflexes, and control of posture and locomotion. Otolith-mediated reflex gains appear to adapt rapidly during spaceflight and after landing. However, animal studies have shown that structural modifications of the vestibular sensory apparatus develop during long-duration spaceflight. To date, no studies have characterized the severity of vestibular syndromes experienced by astronauts as a function of the duration of spaceflight or whether the effects are caused by changes at the peripheral end organs, midbrain, cerebellum, or vestibular cortex. OBJECTIVES We are investigating temporal vestibular changes in crewmembers of short, 6-month, and one-year missions to identify trends in adaptation of vestibular health and performance in orbit and after landing. We are also differentiating between peripheral and central vestibular forms of vertigo and oculomotor disorders. METHODS Recordings of eye, head, and body movements, as well as subjective reports of perception of motion, are being used to determine the presence of abnormal eye movements, dysmetria, motion sickness symptoms, and illusions of motion during head or body movements. This includes characterization of temporal trends in central compensation for vestibular (otolith) asymmetry. In-flight examinations are being performed early in the mission (Flight Days 1 and 30) and once every 2-3 months thereafter. Postflight examinations are performed after return (R) from the mission on R+0, R+4, R+9, and R+30. The inflight and postflight motion sickness questionnaires are customized to support data sharing across related studies. Ground-based control testing has been performed on healthy volunteers(18 females, 14 males;38.6 ± 9.2 years) in the laboratory to estimate mean normative responses, and on patients with bilateral vestibulopathy (BVP) (17 females, 13 males; 60.6 ± 13.0 years) at the University of Caen. RESULTS As of September 2024, two crewmembers have completed all preflight, inflight, and postflight testing. Additional crewmembers are currently enrolled and data collection is currently ongoing. For ground testing, BVP patients performed similarly to previous postflight astronauts on R+0 in various walking performance tasks. Three additional body movement perception tasks have been tested. For the Triangle Completion Task, BVP patients had a larger mean angle of deviation and longer mean distance than healthy controls. For the Self-Rotation Task and Distance Perception Task, BVP patients had larger errors than healthy controls. These data suggest that vestibular deficiencies impact all aspects of body movement perception tested; whereas previous studies suggest that vestibular deficiencies are only associated with directional errors, not with overall trajectories/path lengths. These data will be compared to those of crewmembers during early postflight readaptation. RELEVANCE If the observed symptoms in crewmembers are more deleterious after the year-long missions than those documented after 6-month missions, then relevant countermeasures will be required to maintain the health and operational performance of astronauts during longer missions. Depending on the etiology of the vestibular syndrome revealed by these tests, countermeasures will be proposed based on vestibular rehabilitation therapies currently used in patients with vestibular disorders, such as habituation, gaze stabilization, and/or balance training exercises. ACKNOWLEDGEMENT This work is supported by NASA’s Human Research Program Human Health Countermeasures Element.

T R Macaulay↗

Spinoff 2015

Topics covered include: 3D Endoscope to Boost Safety, Cut Cost of Surgery; Audio App Brings a Better Night's Sleep Liquid Cooling Technology Increases Exercise Efficiency; Algae-Derived Dietary Ingredients Nourish Animals; Space Grant Research Launches Rehabilitation Chair; Vision Trainer Teaches Focusing Techniques at Home; Aircraft Geared Architecture Reduces Fuel Cost and Noise; Ubiquitous Supercritical Wing Design Cuts Billions in Fuel Costs; Flight Controller Software Protects Lightweight Flexible Aircraft; Cabin Pressure Monitors Notify Pilots to Save Lives; Ionospheric Mapping Software Ensures Accuracy of Pilots' GPS; Water Mapping Technology Rebuilds Lives in Arid Regions; Shock Absorbers Save Structures and Lives during Earthquakes; Software Facilitates Sharing of Water Quality Data Worldwide; Underwater Adhesives Retrofit Pipelines with Advanced Sensors; Laser Imaging Video Camera Sees through Fire, Fog, Smoke; 3D Lasers Increase Efficiency, Safety of Moving Machines; Air Revitalization System Enables Excursions to the Stratosphere; Magnetic Fluids Deliver Better Speaker Sound Quality; Bioreactor Yields Extracts for Skin Cream; Private Astronaut Training Prepares Commercial Crews of Tomorrow; Activity Monitors Help Users Get Optimum Sun Exposure; LEDs Illuminate Bulbs for Better Sleep, Wake Cycles; Charged Particles Kill Pathogens and Round Up Dust; Balance Devices Train Golfers for a Consistent Swing; Landsat Imagery Enables Global Studies of Surface Trends; Ruggedized Spectrometers Are Built for Tough Jobs; Gas Conversion Systems Reclaim Fuel for Industry; Remote Sensing Technologies Mitigate Drought; Satellite Data Inform Forecasts of Crop Growth; Probes Measure Gases for Environmental Research; Cloud Computing Technologies Facilitate Earth Research; Software Cuts Homebuilding Costs, Increases Energy Efficiency; Portable Planetariums Teach Science; Schedule Analysis Software Saves Time for Project Planners; Sound Modeling Simplifies Vehicle Noise Management; Custom 3D Printers Revolutionize Space Supply Chain; Improved Calibration Shows Images' True Colors; Micromachined Parts Advance Medicine, Astrophysics, and More; Metalworking Techniques Unlock a Unique Alloy; Low-Cost Sensors Deliver Nanometer-Accurate Measurements; Electrical Monitoring Devices Save on Time and Cost; Dry Lubricant Smooths the Way for Space Travel, Industry; and Compact Vapor Chamber Cools Critical Components.

Source record↗

Effects of training on muscle O2 transport at VO2max

To quantify the relative contributions of convective and peripheral diffusive components of O2 transport to the increase in leg O2 uptake (VO2leg) at maximum O2 uptake (VO2max) after 9 wk of endurance training, 12 sedentary subjects (age 21.8 +/- 3.4 yr, VO2max 36.9 +/- 5.9 ml.min-1.kg-1) were studied. VO2max, leg blood flow (Qleg), and arterial and femoral venous PO2, and thus VO2leg, were measured while the subjects breathed room air, 15% O2, and 12% O2. The sequence of the three inspirates was balanced. After training, VO2max and VO2leg increased at each inspired O2 concentration [FIO2; mean over the 3 FIO2 values 25.2 +/- 17.8 and 36.5 +/- 33% (SD), respectively]. Before training, VO2leg and mean capillary PO2 were linearly related through the origin during hypoxia but not during room air breathing, suggesting that, at 21% O2, VO2max was not limited by O2 supply. After training, VO2leg and mean capillary PO2 at each FIO2 fell along a straight line with zero intercept, just as in athletes (Roca et al. J. Appl. Physiol. 67: 291-299, 1989). Calculated muscle O2 diffusing capacity (DO2) rose 34% while Qleg increased 19%. The relatively greater rise in DO2 increased the DO2/Qleg, which led to 9.9% greater O2 extraction. By numerical analysis, the increase in Qleg alone (constant DO2) would have raised VO2leg by 35 ml/min (mean), but that of DO2 (constant Qleg) would have increased VO2leg by 85 ml/min, more than twice as much. The sum of these individual effects (120 ml/min) was less (P = 0.013) than the observed rise of 164 ml/min (mean). This synergism (explained by the increase in DO2/Qleg) seems to be an important contribution to increases in VO2max with training.

NASA Discipline Musculoskeletal↗